Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector control systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Micro-optics technology and sensor systems applications

The current generation of electro-optical sensors utilizing refractive and reflective optical elements require sophisticated, complex, and expensive designs. Advanced-technology-based electro-optical sensors of minimum size and weight require miniaturization of optical, electrical, and mechanical devices with an increasing trend toward integration of various components. Micro-optics technology has the potential in a number of areas to simplify optical design with improved performance. This includes internally cooled apertures, hybrid optical design, microlenses, dispersive multicolor microlenses, active dither, electronically controlled optical beam steer, and microscopic integration of micro-optics, detectors, and signal processing layers. This paper describes our approach to the development of micro-optics technology with our main emphasis for sensors applications.

Gal, George↗

Using Quasiparticle Poisoning To Detect Photons

According to a proposal, a phenomenon associated with excitation of quasiparticles in certain superconducting quantum devices would be exploited as a means of detecting photons with exquisite sensitivity. The phenomenon could also be exploited to perform medium-resolution spectroscopy. The proposal was inspired by the observation that Coulomb blockade devices upon which some quantum logic gates are based are extremely sensitive to quasiparticles excited above the superconducting gaps in their leads. The presence of quasiparticles in the leads can be easily detected via the charge states. If quasiparticles could be generated in the leads by absorption of photons, then the devices could be used as very sensitive detectors of electromagnetic radiation over the spectral range from x-rays to submillimeter waves. The devices in question are single-Cooper-pair boxes (SCBs), which are mesoscopic superconducting devices developed for quantum computing. An SCB consists of a small superconducting island connected to a reservoir via a small tunnel junction and connected to a voltage source through a gate capacitor. An SCB is an artificial two-level quantum system, the Hamiltonian of which can be controlled by the gate voltage. One measures the expected value of the charge of the eigenvectors of this quantum system by use of a radio-frequency single-electron transistor. A plot of this expected value of charge as a function of gate voltage resembles a staircase that, in the ideal case, consists of steps of height 2 e (where e is the charge of one electron). Experiments have shown that depending on the parameters of the device, quasiparticles in the form of "broken" Cooper pairs present in the reservoir can tunnel to the island, giving rise to steps of 1 e. This effect is sometimes called "poisoning." Simulations have shown that an extremely small average number of quasiparticles can generate a 1-e periodic signal. In a device according to the proposal, this poisoning would be turned to advantage. Depending on the wavelength, an antenna or other component would be used to couple radiation into the reservoir, wherein the absorption of photons would break Cooper pairs, thereby creating quasiparticles that, in turn, would tunnel to the island, creating a 1-e signal. On the basis of conservative estimates of device parameters derived from experimental data and computational simulations that fit the data, it has been estimated that the noise equivalent power of a device according to the proposal could be as low as 6 10(exp -22) W/Hz(exp 1/2). It has also been estimated that the spectroscopic resolution (photon energy divided by increment of photon energy) of such a device in visible light would exceed 100.

Echternach, Pierre↗

Spatial-frequency response of the Limb Infrared Monitor of the Stratosphere /LIMS/ radiometer

The Limb Infrared Monitor of the Stratosphere (LIMS), an experiment on the Nimbus-7 satellite, is designed to scan the earth's limb vertically and measure spectral emission profiles of trace atmospheric gases believed to be important in processes controlling the stratospheric ozone distribution. Experiment objectives are reviewed and several analyses and measurements are described which were performed to determine the adequacy of the system for satisfying these objectives. Adequate spatial-frequency response for all the spectral channels is required to provide, through inversion of the measured limb-radiance profiles, important information about the temperature, structure, and composition of the atmosphere. From the LIMS design-model data, the MTF was calculated for the optical system, the detector field mask, the electronics, and the overall system, for each channel. The signal output performance of the instrument was predicted from the system MTF data model input radiance data for each channel. MTF measurements made on the flight sensor confirmed the analytical results. The predictions indicate that the instrument can satisfy the basic measurement objectives of the experiment.

Wilson, R. G.↗

Results From Cs Activated GaN Photocathode Development for MCP Detector Systems at GSFC

We describe the development of high quantum efficiency W photocathodes for use in large area two dimensional microchannel plate based detector arrays to enable new W space astronomy missions. Future W missions will require improvements in detector sensitivity, which has the most leverage for cost-effective improvements in overall telescope/instrument sensitivity. We use new materials such as p-doped GaN, AIGaN, ZnMgO, Sic and diamond. We have currently obtained QE values > 40 % at 185 nm with Cesiated GaN, and hope to demonstrate higher values in the future. By using controlled internal fields and nano-structuring of the surfaces, we plan to provide field emission assistance for photoelectrons while maintaining their energy distinction from dark noise electrons. We will transfer these methods from GaN to ZnMgO, a new family of wide band-gap materials more compatible with microchannel plates. We also are exploring technical parameters such as doping profiles, internal and external field strengths, angle of incidence, field emission assistance, surface preparation, etc.

Norton, Tim↗

Thermal Assessment of Swift BAT Instrument Thermal Control System in Flight

THE BAT is the primary instrument on the Swift spacecraft. The Swift mission is part of the National Aeronautics and Space Administration (NASA) Medium-Size Explorer (MIDEX) Program, and is managed by Goddard Space Flight Center (GSFC). It is designed to detect gamma ray burst over a broad region of the sky in a low Earth orbit of 600-km altitude and quickly align the telescopes on the spacecraft to the gamma ray source. It was successfully launched into orbit on November 20, 2004. The Swift mission is a first of its kind of multi-wavelength transient observatory for gamma ray burst astronomy. Its mission life is 2 years. The inclination is 22 deg maximum. The spacecraft bus voltage to the instruments is in the 24 V to 35 V range. The instruments will be turned off when the voltage is below 27 V. The BAT is mounted to the optical bench through five titanium flexures. The BAT has been developed at GSFC. Its telescope assembly consists of 256 Detector Modules (DMs) in the Detector Array. There are 16 Detector Array Blocks. Each Block holds 16 DMs, 3 Block Voltage Regulator (BVR) units and 3 Block Command & Data Handling (BCDH) units. The power dissipation of each Block has been measured to be 13 W. Therefore the total power dissipation of the 16 Blocks is 208 W. The DAP is 1.3 m (4.3 ft) x 1 m (3.3 ft), accommodates all the 16 Blocks. It also provides the mounting surface and the positional stability for the Blocks. The DMs are located at the top (+X side) of the DAP and is enclosed by graded-Z shields on the sides and a coded mask at the top. The BVRs and BCDHs are located at the bottom (-X side) of the DAP. Eight Blocks are located at the front (-Z side or radiator side) of the DAP, and eight are located at the rear (+Z side) of the DAP. The DMs and top of DAP are insulated with a 7-layer multi-layer insulation (MLI). There is a 5.08 cm (2 in) x 5.08 cm (2 in) MLI cutout over each Block heater controller so that heat radiates from the heater controller to the mask. The exterior of the mask, graded-Z shields and bottom of DAP is insulated with a 15-layer MLI.

Choi, Michael K.↗

Epithermal Neutron Resonance Analysis Using a Compact D-T Generator

Nuclear material identification and isotopic composition analysis are important capabilities for safeguards and the verification of nuclear arms control and nonproliferation treaties. Epithermal neutron resonance imaging has been proposed for spent fuel assay measurements, and the development of a mobile neutron imaging system could provide such a tool for on-site applications. This technique is highly sensitive to isotopes of interest for safeguards applications (e.g. 235,238 U, 238,239,240 Pu) and yields unique transmission spectra for a target containing actinides and some mid- and high-Z elements. Paired with a position-sensitive neutron detector, such a system could provide spatial information of the target isotopic composition. Recent progress in the development of high intensity neutron sources could make mobile epithermal neutron imaging designs increasingly feasible to serve as a tool for nuclear inspectors. In this work, Monte Carlo (MC) simulations were performed to further optimize a previous design for an epithermal neutron resonance-based analysis apparatus using a D-T portable neutron generator. Additionally, experimental work is being performed to test the feasibility of this method. The MC simulations of moderation time distributions for different moderator compositions and thicknesses were measured to provide a multi-group correction for neutron time-of-flight energy reconstruction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA Tech Briefs, August 2008

Customizable Digital Receivers for Radar Two-Camera Acquisition and Tracking of a Flying Target Visual Data Analysis for Satellites A Data Type for Efficient Representation of Other Data Types Hand-Held Ultrasonic Instrument for Reading Matrix Symbols Broadband Microstrip-to-Coplanar Strip Double-Y Balun A Topographical Lidar System for Terrain-Relative Navigation Programmable Low-Voltage Circuit Breaker and Tester Electronic Switch Arrays for Managing Microbattery Arrays Topics covered include: Lower-Dark-Current, Higher-Blue-Response CMOS Imagers; Fabricating Large-Area Sheets of Single-Layer Graphene by CVD; Support for Diagnosis of Custom Computer Hardware; Providing Goal-Based Autonomy for Commanding a Spacecraft; Dynamic Method for Identifying Collected Sample Mass; Optimal Planning and Problem-Solving; Attitude-Control Algorithm for Minimizing Maneuver Execution Errors; Grants Document-Generation System; Heat-Storage Modules Containing LiNO3 3H2O and Graphite Foam; Precipitation-Strengthened, High-Temperature, High-Force Shape Memory Alloys; Improved Relief Valve Would Be Less Susceptible to Failure; Safety Modification of Cam-and-Groove Hose Coupling; Using Composite Materials in a Cryogenic Pump; Using Electronic Noses to Detect Tumors During Neurosurgery; Producing Newborn Synchronous Mammalian Cells; Smaller, Lower-Power Fast-Neutron Scintillation Detectors; Rotationally Vibrating Electric-Field Mill; Estimating Hardness from the USDC Tool-Bit Temperature Rise; Particle-Charge Spectrometer; Automated Production of Movies on a Cluster of Computers; FIDO-Class Development Rover; and Tone-Based Command of Deep Space Probes Using Ground Antennas.

Source record↗

Absolute calibration of a hydrogen discharge lamp in the vacuum ultraviolet

A low-pressure hydrogen discharge lamp was calibrated for radiant intensity in the vacuum ultraviolet spectral region on an absolute basis and was employed as a laboratory standard source in spectrograph calibrations. This calibration was accomplished through the use of a standard photodiode detector obtained from the National Bureau of Standards together with onsite measurements of spectral properties of optical components used. The stability of the light source for use in the calibration of vacuum ultraviolet spectrographs and optical systems was investigated and found to be amenable to laboratory applications. The lamp was studied for a range of operating parameters; the results indicate that with appropriate peripheral instrumentation, the light source can be used as a secondary laboratory standard source when operated under preset controlled conditions. Absolute intensity measurements were recorded for the wavelengths 127.7, 158.0, 177.5, and 195.0 nm for a time period of over 1 month, and the measurements were found to be repeatable to within 11 percent.

Nealy, J. E.↗

Portable Fourier Transform Spectroscopy for Analysis of Surface Contamination and Quality Control

Progress has been made into adapting and enhancing a commercially available infrared spectrometer for the development of a handheld device for in-field measurements of the chemical composition of various samples of materials. The intent is to duplicate the functionality of a benchtop Fourier transform infrared spectrometer (FTIR) within the compactness of a handheld instrument with significantly improved spectral responsivity. Existing commercial technology, like the deuterated L-alanine triglycine sulfide detectors (DLATGS), is capable of sensitive in-field chemical analysis. This proposed approach compares several subsystem elements of the FTIR inside of the commercial, non-benchtop system to the commercial benchtop systems. These subsystem elements are the detector, the preamplifier and associated electronics of the detector, the interferometer, associated readout parameters, and cooling. This effort will examine these different detector subsystem elements to look for limitations in each. These limitations will be explored collaboratively with the commercial provider, and will be prioritized to meet the deliverable objectives. The tool design will be that of a handheld gun containing the IR filament source and associated optics. It will operate in a point-and-shoot manner, pointing the source and optics at the sample under test and capturing the reflected response of the material in the same handheld gun. Data will be captured via the gun and ported to a laptop.

Pugel, Diane↗

SuperHERO (Super - High Energy Replicated Optics) Balloon Mission Concept

The SuperHERO hard-x-ray telescope is a proposed high-angular resolution successor to Marshall Space Flight Center’s (MSFC) successful High Energy Replicated Optic (HERO) and the HERO to Explore the Sun (HEROES) balloon missions. By utilizing recent advancements in MSFC’s replicated full shell, NiCo x-ray optic technology, SuperHERO will achieve its technical goal of demonstrating better than 10 arcseconds (arcsecs) angular resolution in half-power diameter (HPD) on a balloon platform. This represents a 6-fold improvement to the current state-of-the-art resolution for hard-x-ray, astrophysical telescopes and will allow for the observation of the high-energy-universe in unprecedented spatial detail. The SuperHERO balloon observatory will consist of seven coaligned, identical telescopes with a total focal length of 12-meters. Each telescope will pair a Mirror Module Assembly (MMA) comprised of NiCo shell optics matched to a CdTe Double-sided Strip Detector (CdTe-DSD) plane provided by iMAGINE-X Inc. and Kavli Institute for the Physics and Mathematics of the Universe (Kavli-IPMU). Iridium coating applied directly to each shell will boost reflectivity into the hard-x-ray regime. Employing additional high-heritage technology, SuperHERO will have an open-truss carbon-composite gondola similarly used on the XL-Calibur balloon mission and will use the Wallops Arc-Second Pointer (WASP) system for attitude control

NickThomas↗

A SiPM-based optical readout system for the EIC dual-radiator RICH

Silicon photomultipliers (SiPM) are candidates selected as the potential photodetector technology for the dual-radiator Ring-Imaging Cherenkov (dRICH) detector at the future Electron-Ion Collider (EIC). SiPM are cheap devices, highly efficient and insensitive to the high magnetic field at the expected location of the sensors in the experiment. Here, on the other hand, SiPM are not radiation tolerant. Despite the integrated radiation level is expected to be moderate it should be tested whether single photon-counting capabilities and the increase in dark count rate can be kept under control to maintain the optimal dRICH detector performance across the years. The current status of the research for the EIC dRICH application and the first results on studies performed on a sample of commercial and prototype SiPM sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SEXTANT X-Ray Pulsar Navigation Demonstration: Flight System and Test Results

The Station Explorer for X-ray Timing and Navigation Technology (SEXTANT) is a technology demonstration enhancement to the Neutron-star Interior Composition Explorer (NICER) mission. NICER is a NASA Explorer Mission of Opportunity that will be hosted on the International Space Station (ISS). SEXTANT will, for the first time, demonstrate real-time, on-board X-ray Pulsar Navigation (XNAV), a significant milestone in the quest to establish a GPS-like navigation capability available throughout our Solar System and beyond. This paper gives an overview of the SEXTANT system architecture and describes progress prior to environmental testing of the NICER flight instrument. It provides descriptions and development status of the SEXTANT flight software and ground system, as well as detailed description and results from the flight software functional and performance testing within the highfidelity Goddard Space Flight Center (GSFC) X-ray Navigation Laboratory Testbed (GXLT) software and hardware simulation environment. Hardware-in-the-loop simulation results are presented, using the engineering model of the NICER timing electronics and the GXLT pulsar simulator-the GXLT precisely controls NASA GSFC's unique Modulated X-ray Source to produce X-rays that make the NICER detector electronics appear as if they were aboard the ISS viewing a sequence of millisecond pulsars.

SEXTANT↗

Preliminary design of a helium cryogenic system for SAND detector at LBNF-DUNE near site

The Long-Baseline Neutrino Facility (LBNF) is providing a helium cryogenic system to support the superconducting solenoid magnet of the System for on-Axis Neutrino Detection (SAND) for the Deep Underground Neutrino Experiment (DUNE) Near Site at Fermilab in Batavia, IL. The design started in 2020 and construction is set to begin in the mid 2020‘s.The helium cryogenic system primarily consists of a helium refrigerator system, distribution valve boxes, vacuum-jacketed helium and nitrogen transfer lines, warm gaseous helium transfer system, instruments and control system, and gaseous helium storage tanks. It is designed to provide supercritical helium at around 3 bara and 5 K with expansion from 3 to 1.2 bara in the SAND cryostat and 70K forced cold gas helium to cool the thermal shields of the SAND cryostat. The SAND superconductive magnet is indirectly cooled through a liquid helium thermosiphon cycle. A pair of 3 kA leads is cooled by the gas helium vaporized from the liquid helium reservoir in the cryostat turret. The helium system will share the liquid nitrogen tank and liquid nitrogen phase separator with the Near Site Liquid Argon system. The helium recycle compressor system, GHe tanks and LN2 tank will be located on the Surface. The cryogenic facilities including refrigerator cold box, valve boxes and LN2 phase separator will be located on the shaft cryo-mezzanine in the underground cavern. The shaft connecting surface and cavern is more than 60 meter deep. The helium vacuum-jacketed transfer line between the cold box and the SAND magnet is more than 50 meter long. This paper presents the preliminary design of the helium cryogenic system including the design scheme, process flow diagram, heat load estimates, layout plan and so on.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-change Reconfigurable Optical WavEfront Synthesis System (PROWESS)

We report the design, fabrication, and testing of electrically tunable metasurface k-space filters based on the low-loss, high-contrast phase-change material GSST and a transparent Si electrode heating architecture. A 10x10 array of PCM elements integrated with Si heaters was fabricated via foundry processes, and used to actively control the crystallinity of a metasurface consisting of GSST nano antennae. By selectively varying the structural state of individual PCM elements, specific k-vectors of transmitted light can effectively be filtered out, resulting in improved imaging quality by reducing the scattered light that reaches a detector. Optimized doping profiles in the Si heaters allow for uniform, low power, reliable and repeatable switching of the GSST state. Compared to other k-space filters, this new architecture is completely transparent to the wavelength of interest and can be actively reconfigured in real time with high performance, low power consumption and a small footprint. The 10x10 array device is a proof-of-concept demonstration that can enable high-resolution arbitrary wavefront synthesis and correction in the future, with key applications in optical communications, beam steering, remote sensing, and adaptive optics.

phase change material↗

An adiabatic demagnetization refrigerator for SIRTF

An adiabatic demagnetization refrigerator (ADR) has been proposed to cool bolometric infrared detectors on the multiband imaging photometer of the Space Infrared Telescope Facility (SIRTF). One such refrigerator has been built which uses a ferric ammonium alum salt pill suspended by nylon threads in a 3-T solenoid. The resonant modes of this suspension are above 100 Hz. The heat leak to the salt pill is less than 0.5 microW. The system has a hold time at 0.1K of more than 12 h. The cold stage temperature is regulated with a feedback loop that controls the magnetic field. A second, similar refrigerator is being built at a SIRTF prototype to fly on a ballon-borne telescope. It will use a ferromagnetic shield. The possibility of using a high-Tc solenoid-actuated heat switch is also discussed.

Timbie, P. T.↗

SPARCLE: Validation of Observing System Simulations (SPace Readiness Coherent Lidar Experiment)

NASA recently approved a mission to fly a Doppler Wind Lidar (DWL) on a U.S. Space Shuttle. SPARCLE, managed by Marshall Space Flight Center in Huntsville, AL, is targeted for launch in March 2001. This mission is viewed as a necessary demonstration of a solid state (2 micron) lidar using coherent detection before committing resources to a 3-5 year research or operational mission. While, to many, this shuttle mission is seen as the first step in a series leading to a fully operational wind observing system, to others, it is a chance to validate predictions of performance based upon theoretical models, analyses of airborne and ground-based data, and sophisticated observing system simulation experiments. This paper will be presented in two parts: first a brief overview of the SPARCLE mission and second, a summary of current performance predictions and key contributions from ground- based and airborne DWL research. The SPARCLE instrument is a 100 mJ, 6 Hz, diode-pumped 2-micron laser with a .25 m telescope using heterodyne mixing in a fiber and an InGaAs detector. A 25 cm silicon wedge scanner will be used in step-stare modes with dwells ranging from 60 seconds to .5 seconds. Pointing knowledge is achieved with a dedicated GPS/INS mounted close to the lidar. NASA's Hitchhiker program is providing the instrument enclosures (2 cans) and mission logistics support. An on-board data system is sized to record 150 Gbytes of raw signal from a two 400 MHZ A/D converters. On-board signal processing will be used to control the frequency of the Local Oscillator. SPARCLE is predicted to have a single shot backscatter sensitivity near 1x10(exp -6) m-1 sr-1, To achieve higher sensitivity, shot accumulation will be employed. Ground-based, 2 micron DWLs have been used to assess the benefits of shot accumulation (approximately SQRT for SNR). Airborne programs like MACAWS have provided good datasets for evaluating various sampling strategies and signal processing algorithms. Using these real data to calibrate our simulation models, we can describe when and how well SPARCLE is expected to preform. Outputs from these performance models will be presented.

Emmitt, G. D.↗

Alignment-Insensitive Lower-Cost Telescope Architecture

This architecture features an active wavefront sensing and control scheme along with methods for measuring the relative positions of the primary to aft optics, such as the secondary mirror, and should enable larger and cheaper telescope architectures needed for future applications. A wavefront source/sensor is placed at the center of curvature of the primary mirror. The system provides continuous light onto a primary mirror that is retro-reflected onto itself. This allows the wavefront controller to constantly update the positions of the primary mirror segments (or deformable mirror actuators). Another function of this innovation involves using a concave mirror on the back of the secondary mirror (or other aft optic) that has the same center-of-curvature location (in defocus) as the primary mirror. The two return beams can be aligned next to each other on a detector, or radially on top of each other. This provides a means with which to measure the relative position of the primary to the secondary (or other aft optics), thus allowing for the removal of misalignment of the center-of-curvature source/sensor (meaning it doesn't need precision placement) and also provides a means with which to monitor the relative alignment over time. This innovation does not require extremely good thermal stability on the primary mirror and can thus be used in any thermal environment and with cheaper materials. In addition to this, the architecture lets one phase (or align) the primary mirror independent of whether a star or scene is in the field. The segmented, spherical primary allows for cost-effective three-meter class (e.g. Midex and Discovery) missions as well as enabling 30-meter telescope solutions that can be manufactured in a reasonable amount of time. The continuous wavefront sensing and control architecture enables missions for low-Earth-orbit.

Feinberg, Lee↗

NASA Tech Briefs, February 2007

Topics covered include: Calibration Test Set for a Phase-Comparison Digital Tracker; Wireless Acoustic Measurement System; Spiral Orbit Tribometer; Arrays of Miniature Microphones for Aeroacoustic Testing; Predicting Rocket or Jet Noise in Real Time; Computational Workbench for Multibody Dynamics; High-Power, High-Efficiency Ka-Band Space Traveling-Wave Tube; Gratings and Random Reflectors for Near-Infrared PIN Diodes; Optically Transparent Split-Ring Antennas for 1 to 10 GHz; Ice-Penetrating Robot for Scientific Exploration; Power-Amplifier Module for 145 to 165 GHz; Aerial Videography From Locally Launched Rockets; SiC Multi-Chip Power Modules as Power-System Building Blocks; Automated Design of Restraint Layer of an Inflatable Vessel; TMS for Instantiating a Knowledge Base With Incomplete Data; Simulating Flights of Future Launch Vehicles and Spacecraft; Control Code for Bearingless Switched- Reluctance Motor; Machine Aided Indexing and the NASA Thesaurus; Arbitrating Control of Control and Display Units; Web-Based Software for Managing Research; Driver Code for Adaptive Optics; Ceramic Paste for Patching High-Temperature Insulation; Fabrication of Polyimide-Matrix/Carbon and Boron-Fiber Tape; Protective Skins for Aerogel Monoliths; Code Assesses Risks Posed by Meteoroids and Orbital Debris; Asymmetric Bulkheads for Cylindrical Pressure Vessels; Self-Regulating Water-Separator System for Fuel Cells; Self-Advancing Step-Tap Drills; Array of Bolometers for Submillimeter- Wavelength Operation; Delta-Doped CCDs as Detector Arrays in Mass Spectrometers; Arrays of Bundles of Carbon Nanotubes as Field Emitters; Staggering Inflation To Stabilize Attitude of a Solar Sail; and Bare Conductive Tether for Decelerating a Spacecraft.

Source record↗