Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Urban working groups in the IAEA’s model testing programmes: overview from the MODARIA I and MODARIA II programmes

The IAEA’s model testing programmes have included a series of Working Groups concerned with modelling radioactive contamination in urban environments. These have included the Urban Working Group of Validation of Environmental Model Predictions (1988–1994), the Urban Remediation Working Group of Environmental Modelling for Radiation Safety (EMRAS) (2003–2007), the Urban Areas Working Group of EMRAS II (2009–2011), the Urban Environments Working Group of (Modelling and Data for Radiological Impact Assessments) MODARIA I (2013–2015), and most recently, the Urban Exposures Working Group of MODARIA II (2016–2019). The overarching objective of these Working Groups has been to test and improve the capabilities of computer models used to assess radioactive contamination in urban environments, including dispersion and deposition processes, short-term and long-term redistribution of contaminants following deposition events, and the effectiveness of various countermeasures and other protective actions, including remedial actions, in reducing contamination levels, human exposures, and doses to humans. This paper describes the exercises conducted during the MODARIA I and MODARIA II programmes. These exercises have included short-range and mid-range atmospheric dispersion exercises based on data from field tests or tracer studies, hypothetical urban dispersion exercises, and an exercise based on data collected after the Fukushima Daiichi accident. We report improvement of model capabilities will lead to improvements in assessing various contamination scenarios (real or hypothetical), and in turn, to improved decision-making and communication with the public following a nuclear or radiological emergency.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of Borate and Organics on U(VI) Solubility in WIPP Brine

The solubility of uranium (VI) in Waste Isolation Pilot Plant (WIPP)-relevant brine was determined to support ongoing WIPP recertification activities. This research was performed by the Los Alamos National Laboratory Carlsbad Operations (LANL-CO) Actinide Chemistry and Repository Science Program (ACRSP). The WIPP Actinide Source Term Program (ASTP) did not develop a model for the solubility of actinides in the VI oxidation state. The solubility of UO 2 2+ , in the absence of WIPP specific data, is presently set to be equal to a conservatively high 1 mM within the WIPP Performance Assessment (PA) for all expected WIPP conditions (SOTERM, 2019) as selected at the recommendation of the Environment Protection Agency (EPA) (EPA, 2005). According to the current WIPP chemistry model assumptions and conditions, the expected pC H+ is about 9.5 and controlled by MgO buffering CO 3 2- . The goal of this study is to perform screening experiments that account for the contributions of organics and borate on uranium solubility. In this report, the solubility of U(VI) was determined at pC H+ 9 WIPP brine in the absence or presence of borate and organics at under-saturation approach. Experiments were equilibrated for about 135 days. Organic compounds present in WIPP waste can form strong complexes with actinides and can affect the oxidation states of actinides. The organic compounds addressed in WIPP performance assessment include EDTA (Ethylenediaminetetraacetic Acid), oxalate, citrate, and acetate (SOTERM, 2019). These data quantify the effects of WIPP-relevant concentrations of borate and organics effects on the solubility of U(VI) to challenge the predictions of the WIPP actinide model and inform decisions and recommendations made in the upcoming recertification of the WIPP (CRA-2024). The experiments performed were done according to the U.S. Department of Energy (DOE) approved Test Plan entitled “Experimental Strategy to Challenge Actinide Solubility Predictions” and designated LCO-ACP-26. All data reported were obtained under the LANL-CO Quality Assurance Program, which is compliant with the DOE Carlsbad Field Office, Quality Assurance Program Document (CBFO/QAPD) (QAPD, 2017).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Summertime methane and carbon dioxide emission rates and associated variables from a national‐scale survey of 146 reservoirs in the United States

Reservoirs are globally important sources of greenhouse gases, but the magnitude of their emissions is highly uncertain. Here, we present data for 146 reservoirs from two surveys of reservoir methane and carbon dioxide emissions, one at the regional scale in the midwestern United States and one at the national scale in the United States, plus data from two hand‐picked sites in Washington and Puerto Rico. At all reservoirs, ebullitive and diffusive emissions and basic physicochemistry were measured at 15–55 locations during one 22 to 64‐h period during the summers of 2016–2023, with four reservoirs revisited a second time. Contemporaneous water chemistry measurements were made at one or two locations in each reservoir. The dataset consists of two geospatial files and seven CSV files containing greenhouse gas emissions, water chemistry, morphology, and other relevant data. To date, these data comprise the largest multi‐reservoir emissions dataset assembled using consistent measurement methods.

Beaulieu, Jake J. [US Environmental Protection Age↗

Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group

Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro- and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. In this work, to respond to these needs, we developed G4-Med, a benchmarking and regression testing system of Geant4 for medical physics. G4-Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4-Med are executed on the CERN computing infrastructure via the use of the geant-val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. This paper describes the tests included in G4-Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data.

60 APPLIED LIFE SCIENCES↗

Capture and Decomposition of the Nerve Agent Simulant, DMCP, Using the Zeolitic Imidazolate Framework (ZIF-8)

Understanding mechanisms of decontamination of chemical warfare agents (CWA) is an area of intense research aimed at developing new filtration materials to protect soldiers and civilians in case of state-sponsored or terrorist attack. In this study, we employed complementary structural, chemical, and dynamic probes and in situ data collection, to elucidate the complex chemistry, capture, and decomposition of the CWA simulant, dimethyl chlorophosphonate (DMCP). Our work reveals key details of the reactive adsorption of DMCP and demonstrates the versatility of zeolitic imidazolate framework (ZIF-8) as a plausible material for CWA capture and decomposition. Here, the in situ synchrotron-based powder X-ray diffraction (PXRD) and pair distribution function (PDF) studies, combined with Fourier transform infrared (FT-IR) spectroscopy, X-ray photoelectron spectroscopy (XPS), zinc K-edge X-ray absorption near edge structure (XANES), and Raman spectroscopies, showed that the unique structure, chemical state, and topology of ZIF-8 enable accessibility, adsorption, and hydrolysis of DMCP into the pores and revealed the importance of linker chemistry and Zn 2+ sites for nerve agent decomposition. DMCP decontamination and decomposition product(s) formation were observed by thermogravimetric analysis, FT-IR spectroscopy, and phosphorus (P) K-edge XANES studies. Differential PDF analysis indicated that the average structure of ZIF-8 (at the 30 Å scale) remains unchanged after DMCP dosing and provided information on the dynamics of interactions of DMCP with the ZIF-8 framework. Using in situ PXRD and diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), we showed that nearly 90% regeneration of the ZIF-8 structure and complete liberation of DMCP and decomposition products occur upon heating.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Four-decade follow-up of a plutonium-contaminated puncture wound treated with Ca-DTPA

Contaminated wounds are a common route of internal deposition of radionuclides for nuclear and radiation workers. They may result in significant doses to radiosensitive organs and tissues in an exposed individual's body. The United States Transuranium and Uranium Registries' whole-body donor (Case 0303) accidentally punctured his finger on equipment contaminated with plutonium nitrate. The wound was surgically excised and medically treated with intravenous injections of Ca-DTPA. A total of 16 g Ca-DTPA was administered in 18 treatments during the 2 months following the accident. Ninety-three urine samples were collected and analysed over 14 years following the accident. An estimated 239 Pu activity of 73.7 Bq was excreted during Ca-DTPA treatment. Post-mortem radiochemical analysis of autopsy tissues indicated that 40 years post-accident 21.6 ± 0.2 Bq of 239 Pu was retained in the skeleton, 12.2 ± 0.3 Bq in the liver, and 3.7 ± 0.1 Bq in other soft tissues; 1.35 ± 0.02 Bq of 239 Pu was measured in tissue samples from the wound site. To estimate the plutonium intake, late urine measurements, which were unaffected by chelation, and post-mortem radiochemical analysis results were evaluated using the IMBA Professional Plus software. The application of the National Council on Radiation Protection and Measurements wound model with an assumption of intake material as a predominantly strongly retained soluble plutonium compound with a small insoluble fraction adequately described the data (p = 0.46). The effective intake was estimated to be 50.2 Bq of plutonium nitrate and 1.5 Bq of the fragment. Here, the prompt medical intervention with contaminated tissue excision and subsequent Ca-DTPA decorporation therapy reduced 239 Pu activity available for uptake and long-term retention in this individual's systemic organs by a factor of 38.

239Pu↗

OASIS: Offsetting Active Reconstruction Attacks in Federated Learning

Federated Learning (FL) has garnered significant attention for its potential to protect user privacy while enhancing model training efficiency. For that reason, FL has found its use in various domains, from health care to industrial engineering, especially where data cannot be easily exchanged due to sensitive information or privacy laws. However, recent research has demonstrated that FL protocols can be easily compromised by active reconstruction attacks executed by dishonest servers. These attacks involve the malicious modification of global model parameters, allowing the server to obtain a verbatim copy of users' private data by inverting their gradient updates. Tackling this class of attack remains a crucial challenge due to the strong threat model. In this paper, we propose a defense mechanism, namely OASIS, based on image augmentation that effectively counteracts active reconstruction attacks while preserving model performance. We first uncover the core principle of gradient inversion that enables these attacks and theoretically identify the main conditions by which the defense can be robust regardless of the attack strategies. We then construct our defense with image augmentation showing that it can undermine the attack principle. Comprehensive evaluations demonstrate the efficacy of the defense mechanism highlighting its feasibility as a solution.

deep neural networks↗

SAS4A/SASSYS-1 Validation with the EBR-II Tests SHRT-17 and SHRT-45R

The EBR-II sodium-cooled fast reactor supported a wide range of fast reactor research activities. The final fifteen years of operations at EBR-II were used for experiments and tests to demonstrate the importance of passive safety in liquid metal reactors and the capability of such systems to provide strong passive responses during off-normal conditions. The Shutdown Heat Removal Test program at EBR-II provided test data supporting the validation of computer codes for design, licensing, and operation of LMRs, among other objectives. The program included nearly sixty tests, most of which were protected and unprotected loss of flow and loss of heat sink tests run at various initial powers and flow rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Financial Exposure After a Sealed-Source Release: Insurance Limits, Federal Cost Pathways, and Implications for Gamma Irradiator Substitution

This report assesses whether private insurance and existing federal authorities would likely provide meaningful financial protection to private operators of self-shielded gamma irradiators after a major sealed-source release. It does not answer this question quantitatively because publicly observable data on premiums, limits, uptake, and claims outcomes for this risk class appear sparse. Instead, it uses a qualitative structural analysis based on prior literature, review of relevant federal authorities, limited observable insurance-market evidence, expert outreach, and historical analogs. The analysis finds that available public and private mechanisms do not combine into a clear, dependable, or readily verifiable compensation structure for ordinary private sealed-source operators. Institutions therefore should not assume that either insurance or government response will make them financially whole after a severe incident. Source reduction and replacement remain more dependable than post-event financial mechanisms for reducing institutional exposure and broader radiological risk.

99 GENERAL AND MISCELLANEOUS↗

Masked fault detection for reliable low voltage cache operation

Systems, apparatuses, and methods for implementing masked fault detection for reliable low voltage cache operation are disclosed. A processor includes a cache that can operate at a relatively low voltage level to conserve power. However, at low voltage levels, the cache is more likely to suffer from bit errors. To mitigate the bit errors occurring in cache lines at low voltage levels, the cache employs a strategy to uncover masked faults during runtime accesses to data by actual software applications. For example, on the first read of a given cache line, the data of the given cache line is inverted and written back to the same data array entry. Also, the error correction bits are regenerated for the inverted data. On a second read of the given cache line, if the fault population of the given cache line changes, then the given cache line's error protection level is updated.

Ganapathy, Shrikanth↗

High-fidelity model-driven deception platform for cyber-physical systems

Methods are described for protecting a cyber-physical system against a potential attacker of the system. The methods include a method of generating a plurality of examples for a training data set and training a system model using the training data set to generate a decoy configured to generate a synthetic output that mimics historical outputs generated by the system for a given historical system context. Also described is a method including receiving a system context of a cyber-physical system; receiving an inquiry into the system by a potential attacker; applying a system model to the system context and the inquiry; obtaining from the system model a synthetic output that mimics how a component of the system would respond to the inquiry given the system context; and providing the synthetic output to the potential attacker.

Edgar, Thomas W.↗

AI-based Detection and Defense Against Cyberattacks in Distributed Energy Resources

This study will provide comprehensive artificial intelligence (AI)-based solution tools for network security, malware prevention, and sensor data anomaly detection for distributed energy resource (DER) research, development, and demonstration. DER technologies are energy systems (e.g., solar panels, wind turbines, and energy storage systems) that are often connected to the internet and thus vulnerable to cyberattacks. Cybersecurity should be of primary concern for DERs, which is why we propose an integrated multi-layer cyber-defense system for DERs. This system encompasses risk assessments, network security, malware prevention, and detection of anomalies in the sensor data. Implementation of a comprehensive risk assessment with an overview of the model architecture should be the primary step, and should include the potential impact of experiencing, at a given time, one or more cyberattacks on the system. The second step is to ensure that the network security includes firewalls, intrusion detection, and malware prevention. The third step is to provide solution tools that enable sensor data anomaly detection for DERs. By incorporating these considerations into DER research, development, and demonstration, organizations can help ensure the safety and security of their systems and protect against potential cyberattacks.

20 FOSSIL-FUELED POWER PLANTS↗

Developing a Prototype Methodology to Rank CO2-EOR Wells and Assess Their Reuse Potential for Geologic Carbon Storage

This paper presents a prototype methodology to assess the possible transition of Class II carbon dioxide-enhanced oil recovery (CO2-EOR) wells to Class VI wells. The focus is on wellbore construction materials—casing, cement, tubing, and the packer—and includes comprehensive workflows to evaluate these materials, with primary emphasis on compliance with Environmental Protection Agency (EPA) Class VI well construction and conversion guidelines. These workflows systematically assess material properties and performance criteria to ensure regulatory compliance and optimize long-term wellbore integrity and functionality. Utilizing Python scripts and JavaScript Object Notation (JSON) representations, the study automates checks on digitized Texas Railroad Commission (TRRC) data to rank wells based on workflow criteria. By emphasizing critical factors such as casing integrity, cementing techniques, tubing compatibility, and packer selection, the methodology helps well owners and operators prioritize wells for potential reuse as CO2 injection wells. Given limitations in digitized data, manual user verification is required in some sections. Future improvements include integrating non-digitized data through web scraping and machine learning techniques. This research serves as a practical guide for stakeholders, supporting environmental compliance and sustainable well operations.

geologic carbon sequestration↗

Preconceptual Design of Irradiated Fuel Salt Management System

The National Reactor Innovation Center was established by the U.S. Department of Energy to accelerate the demonstration and deployment of advanced nuclear reactors. To meet this mission, the National Reactor Innovation Center has developed the Laboratory for Operations and Testing in the U.S. (LOTUS) to support the first fast-spectrum molten salt reactor demonstration. The goal of this research is to understand the system requirements that may be applied to a molten salt reactor experiment in the LOTUS test bed and to perform systems analyses and preconceptual development of a storage container for the management of the irradiated molten salt fuel. This study proposes a set of irradiated fuel salt management processes for the molten salt reactor, from defueling to storage or disposal. For that, the historic Molten Salt Reactor Experiment (MSRE) at Oak Ridge National Laboratory has served as a crucial source of data for a mock application. This paper proposes a potential geometry for storing irradiated fuel salt based on MSRE data and the Monte Carlo N-Particle radiation transport code. The geometry was analyzed for criticality safety under abnormal situations, such as water ingress and interaction between containers. Based on the determined configuration of the storage system, the decay heat produced from the irradiated fuel salts was calculated to provide a reasonable time scale of the dormancy period. Using the same geometry assumed above, the neutron and gamma dose rates from the irradiated fuel salt at the end of the dormancy period were estimated, which will be useful for understanding the handling and radiation protection requirements for handling the irradiated fuel salt. Lastly, a reactor in the LOTUS test bed could use chloride-based fuel as opposed to the fluoride-based fuel used in MSRE. Thus, a literature study provided data to understand the similarities and differences between the characteristics of fluoride- and chloride-based salts in terms of salt chemistry, material characteristics, postirradiation behavior, neutronics, thermal hydraulics, and heat removal. This study, together with the proposed irradiated fuel salt management processes, preliminary criticality calculations, decay heat, and dose rate estimates, provides a strong basis for future investigation into the management of irradiated fuel salts generated during molten salt reactor technology demonstrations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Contributions of anoxic microsites to soil carbon protection across soil textures

Anoxic microsites, zones of oxygen depletion in otherwise oxic soils, may slow soil C turnover. However, the abundance of anoxic microsites and their contribution to soil C protection is yet undefined. In this study, we determine the contribution of anoxic microsites to soil C protection in soils of three distinct textures (clay loam, loam, sandy loam) across a range of soil moistures. We examined the influence of soil oxygen supply by increasing oxygen content in the incubation atmosphere (oxygen enrichment) and through disaggregation. We attributed increases in CO 2 efflux to the aeration of anoxic microsites. The contribution of anoxic microsites to soil C protection increased with decreasing clay content. Clay loam CO 2 efflux was relatively unaffected by aeration. Moderately moist, loam soils had CO 2 effluxes that did not increase with oxygen enrichment but increased by 375% upon disaggregation. Sandy loam soil CO 2 efflux increased by 50–75% with oxygen enrichment and 250% with disaggregation. Geochemical and microbial data reveal that anoxic microsite abundance also increased with decreasing clay content. The proportion of acid extractable Fe present as Fe(II) increased with decreasing clay content, and methanogens were more abundant in loam and sandy loam soils. Our results suggest that oxygen demand, rather than supply, can regulate anoxic microsite formation and that anoxic protection of soil C can be diminished through physical disruption of soil structure. Our findings further illustrate that anoxic microsites should be included in conceptual models of soil C protection to avoid soil C loss and improve predictions of soil C response to disturbance.

58 GEOSCIENCES↗

Machine Learning Based Resilience Testing of an Address Randomization Cyber Defense

Moving target defenses (MTDs) are widely used as an active defense strategy for thwarting cyberattacks on cyber-physical systems by increasing diversity of software and network paths. Recently, machine Learning (ML) and deep Learning (DL) models have been demonstrated to defeat some of the cyber defenses by learning attack detection patterns and defense strategies. It raises concerns about the susceptibility of MTD to ML and DL methods. Here, in this article, we analyze the effectiveness of ML and DL models when it comes to deciphering MTD methods and ultimately evade MTD-based protections in real-time systems. Specifically, we consider a MTD algorithm that periodically randomizes address assignments within the MIL-STD-1553 protocol—a military standard serial data bus. Two ML and DL-based tasks are performed on MIL-STD-1553 protocol to measure the effectiveness of the learning models in deciphering the MTD algorithm: 1) determining whether there is an address assignments change i.e., whether the given system employs a MTD protocol and if it does 2) predicting the future address assignments. The supervised learning models (random forest and k-nearest neighbors) effectively detected the address assignment changes and classified whether the given system is equipped with a specified MTD protocol. On the other hand, the unsupervised learning model (K-means) was significantly less effective. The DL model (long short-term memory) was able to predict the future addresses with varied effectiveness based on MTD algorithm's settings.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗