Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Josephson dynamics in two-dimensional ring-shaped condensates

We investigate Josephson transport in a fully closed, two-dimensional superfluid circuit formed by a ring-shaped 87 Rb Bose-Einstein condensate that contains two optical barriers acting as movable weak links. Translating these barriers at controlled speeds imposes a steady bias current, enabling direct mapping of the current-chemical-potential (𝐼−Δ⁢𝜇) characteristics. For narrow junctions (𝑤 ≈ 1µ⁢m), the circuit exhibits a pronounced dc branch that terminates at a critical current 𝐼 𝑐 = 9⁢(1) × 10 3 s −1 ; above this threshold, the system switches to an ac, resistive regime. Classical-field simulations that include the moving barriers quantitatively reproduce both the nonlinear 𝐼−Δ⁢𝜇 curve and the measured 𝐼 𝑐 , validating the underlying microscopic picture. Analysis of the ensuing phase dynamics shows that dissipation is mediated by the nucleation and traversal of vortex-antivortex pairs through the junctions, while the bulk condensate remains globally phase locked—direct evidence of the ring's topological constraint enforcing quantized circulation. These results establish a cold-atom analog of a superconducting quantum interference device in which Josephson dynamics can be resolved at the single-vortex level, providing a versatile platform for atomtronic circuit elements, nonreciprocal Josephson devices, and on-chip Sagnac interferometers for multiaxis rotation sensing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Current-Driven Magnetization Reversal in Orbital Chern Insulators

Graphene multilayers with flat moiré minibands can exhibit the quantized anomalous Hall effect due to the combined influence of spontaneous valley polarization and topologically nontrivial valley-projected bands. The sign of the Hall effect in these Chern insulators can be reversed either by applying an external magnetic field, or by driving a transport current through the system. Here we propose a current-driven mechanism whereby reversal occurs along lines in the (current I , magnetic-field B ) control parameter space with slope d I / d B = ( e / h ) M A M ( 1 – γ 2 ) / γ , where M is the magnetization, A M is the moiré unit cell area, and γ < 1 is the ratio of the chemical potential difference between valleys along a domain wall to the electrical bias e V .

2-dimensional systems↗

Triple Phase-Shift Optimization of SiC-based Dual-Active Bridge DC/AC Converter

This paper presents a loss-optimized Triple Phase-Shift (TPS) switching strategy for Dual-Active Bridge (DAB) based converters. The proposed strategy considers minimizing total converter loss with respect to minimizing device rms cur-rents, enabling Zero-Voltage Switching (ZVS) turn-on of devices and accurate control of device turn-off current. A model for switching currents is presented, followed by a loss model and optimization strategy. A 1.3kV/100kW prototype based on SiC MOSFETs was used in this work and experimental results up to 10kW show the proposed TPS strategy to be more efficient for operation.

Vetrivelan, Adithyan↗

System Modeling and Robust Stability Region Analysis for Multi-inverters Based on VSG

As the number of inverter-interfaced distributed generators (IIDGs) increases, the decrease in the inertia of the microgrid affects the stability of microgrid voltage and current. The virtual synchronous generator (VSG) control method simulates the output characteristics of the synchronous machine to improve the inertia and damping of the microgrid. However, low-frequency oscillations can occur in systems with multi-VSGs connected in parallel, primarily when operating in island mode. Therefore, this article develops the small-signal state-space model for multi-inverters based on VSG and analyses the robust stability region (RSR) of the control parameters. Firstly, an extensible small-signal state-space model is established and simplified in the dq axis, which is a necessary preprocessing for the subsequent stability analysis. Secondly, the guardian map method based on bialternate product operation is constructed, and the RSR is established through translation mapping and rotation mapping. Therefore, the solution of RSR is transformed into the problem of identifying the Hurwitz matrix. Finally, the simulations and experiments verify that the calculated region can ensure stable operation during startup and meet the requirement to suppress low-frequency oscillations. In conclusion, the method of solving RSR proposed in this paper provides a basis for selecting controller parameters in practical engineering.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DC Circuit Breakers: A Technology Development Status Survey

DC circuit breakers (DCCBs) play a significant role in obtaining the reliability and stability of DC power systems. Selective and fast isolating of faults minimizes the power supply outages to end electricity users and protects the power converters implemented in the DC system. During the last decades, DCCBs have been deeply investigated in industry and academia. There has been impressive progress in terms of efficiency, response time, power-density, lifetime, and electrical operating ratings. Introducing wide bandgap (WBG) devices further has motivated researchers to propose more efficient and novel topologies. This paper provides a point of reference and a background review for DCCBs from novel aspects, fulfilling absent parts in the literature. The elaborated subjects include current commutation circuitry, DCCBs trip-curves developments, newly added functions to DCCBs, as well as marketing analysis. The advancements of DCCBs are surveyed and development needs are recognized. This paper aims to identify the future research needs of DCCBs for emerging DC power systems.

42 ENGINEERING↗

Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines

Grid-forming wind turbines must be able to re-energize transmission branches, motor loads, unbalanced loads, and power electronics loads following a blackout. Further, they must ride through faults that can arise during restoration. To tackle these challenges, this paper sets forth a grid-forming control strategy for wind turbines using doubly-fed induction generators (DFIGs). In particular, a special set of feedforward control loops are engineered to mitigate the impacts of restoration transients as well as symmetrical and asymmetrical faults on the regulation of DFIG rotor currents and stator voltages. This paper also leverages two-axis anti-windup regulators to bound two-axis voltage and current commands within ratings. As a result, the controller performance is demonstrated via a high-fidelity simulation model of a notional wind-dominant grid.

17 WIND ENERGY↗

TRIZ-Based Design Improvement for Facilitating Transmission Control Unit Remanufacturing

Design for Remanufacturing (DfRem) centers on enhancing product design and operations to facilitate remanufacturing while increasing both economic and environmental sustainability. DfRem requires a comprehensive understanding of product characteristics, production conditions, and operational constraints. Thus, DfRem requires a systematic methodology to identify and implement alternative designs. Among many critical steps in remanufacturing, disassembly is essential because it directly supports remanufacturing by separation of product components for cleaning, inspection, and other subsequent process steps. This study proposes a TRIZ-based framework to improve product design for disassembly in support of remanufacturing. The framework is applied to a transmission control unit (TCU) case study. The current TCU design prevents remanufacturing due to the sealant-based component joinery, which complicates disassembly and risks damaging the printed circuit board (PCB). After defining technical contradictions for the TCU product design and reviewing the suggested TRIZ principles to solve the conflicts, a cantilever snap-fit design alternative is developed. The economic feasibility of the snap-fit design is assessed by comparing the current and snap-fit design costs for three life cycles. The cost analysis demonstrates that the cost of the snap-fit design remains the same as the current design. Additionally, the snap-fit design offers substantial cost savings for three life cycles compared to the current design. We demonstrate how snap-fit design supports both environmental and economic sustainability.

42 ENGINEERING↗

Programming twist angle and strain profiles in 2D materials

Moiré superlattices in twisted two-dimensional materials have generated tremendous excitement as a platform for achieving quantum properties on demand. However, the moiré pattern is highly sensitive to the interlayer atomic registry, and current assembly techniques suffer from imprecise control of the average twist angle, spatial inhomogeneity in the local twist angle, and distortions caused by random strain. We manipulated the moiré patterns in hetero- and homobilayers through in-plane bending of monolayer ribbons, using the tip of an atomic force microscope. This technique achieves continuous variation of twist angles with improved twist-angle homogeneity and reduced random strain, resulting in moiré patterns with tunable wavelength and ultralow disorder. Our results may enable detailed studies of ultralow-disorder moiré systems and the realization of precise strain-engineered devices.

Science & Technology - Other Topics↗

Single Atomic Iron Site Catalysts via Benign Aqueous Synthesis for Durability Improvement in Proton Exchange Membrane Fuel Cells

Atomically-dispersed iron-nitrogen-carbon (Fe–N–C) catalysts have arisen as promising candidates for replacing the costly precious metal catalysts in fuel cells but still face some grand challenges, such as insufficient site density and durability. Herein, we report a self-assembly method in an aqueous solution to develop an atomically-dispersed iron catalyst with high oxygen reduction reaction (ORR) activity and stability in acidic electrolytes. As determined by high-resolution transmission electron microscopy (HR-TEM), X-ray absorption spectroscopy (XAS), and high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM), this benign aqueous synthesis strategy facilitates the formation of homogeneous atomic nitrogen-coordinated iron sites embedded in a popcorn-like porous graphitic carbon matrix. These catalyst properties contribute to the improved ORR kinetic current density and mass transport. By controlling synthesis chemistry, the correlation between structure and property is systematically investigated. In this work, the iron content is the most critical material property and can regulate site density and graphitic carbon structures in the catalyst, impacting catalytic activity and stability. The enhanced performance and durability were examined in both acidic aqueous electrolytes and membrane electrode assemblies.

25 ENERGY STORAGE↗

Electrolytic Etching of Germanium Substrates with Hydrogen Peroxide

Anodic electrolytic etching of germanium has been performed in hydrogen peroxide etchants with controlled external conditions. In-situ current and ex-situ etch-depths were measured and tracked with respect to etchant composition and stir rates. Gas bubbles formed during the etching process were found to cause non-uniformity in etch-current and surface quality. The effects were minimized in specific composition spaces. Quantitative analysis revealed a linear correlation of the number of electrons transferred during germanium oxidation with the number of surface atoms removed. Experimental results of 2.77 electrons/atom deviate significantly from 4 electrons/atom previously reported for silicon. The conclusion is that etching mechanisms for germanium are sufficiently different from those for silicon which invalidates the direct transfer of processing techniques between the two materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TCF High Efficiency Anaerobic Electroporation

The Joint BioEnergy Institute (JBEI) researchers were co-inventors of the technology that will be used on this project and have developed a more current version of the chip and controller. JBEI will also assist with the design of the pathways and implementation of pathways on the chip. LanzaTech has developed novel gas fermentation technology that captures and utilizes greenhouse gases for production of fuels and chemicals. In contrast to traditional fermentation that uses sugars as substrate (and releases CO2 as a byproduct), gas fermentation utilizes C1 substrates carbon monoxide (CO) or CO2. This enables a diverse range of feedstock options including waste gases from industrial sources (e.g., steel mills and processing plants) or syngas generated from any biomass resource (e.g., agricultural waste, municipal solid waste, or organic industrial waste). Biomass is then gasified, allowing for maximum yields and complete carbon utilization including the recalcitrant lignocellulosic fraction that cannot be utilized in traditional sugar fermentation.

09 BIOMASS FUELS↗

TCF High Efficiency Anaerobic Electroporation (CRADA Final Report)

The Joint BioEnergy Institute (JBEI) researchers were co-inventors of the technology that will be used on this project and have developed a more current version of the chip and controller. JBEI will also assist with the design of the pathways and implementation of pathways on the chip. LanzaTech has developed novel gas fermentation technology that captures and utilizes greenhouse gases for production of fuels and chemicals. In contrast to traditional fermentation that uses sugars as substrate (and releases CO2 as a byproduct), gas fermentation utilizes C1 substrates carbon monoxide (CO) or CO2. This enables a diverse range of feedstock options including waste gases from industrial sources (e.g., steel mills and processing plants) or syngas generated from any biomass resource (e.g., agricultural waste, municipal solid waste, or organic industrial waste). Biomass is then gasified, allowing for maximum yields and complete carbon utilization including the recalcitrant lignocellulosic fraction that cannot be utilized in traditional sugar fermentation. To maximize the value that can be added to the array of gas resources that the LanzaTech process can use as an input, LanzaTech has pioneered genetic modification of acetogens and developed a comprehensive set of genetic tools to perform routine strain modification, including genome editing tools as CRISPR/Cas9 and libraries of validated genetic parts as promoters and terminators. Using this platform, production of over 50 new molecules have been demonstrated directly from gas. For a few selected molecules production rates and yields have been optimized and surpass production of native producers and engineered E. coli or yeast strains, but a higher throughput approach for combinatorial optimization of pathways is required to further advance synthesis of additional products in parallel.

09 BIOMASS FUELS↗

Tracking and Protecting High-Value/High-Visibility Assets

Pacific Northwest National Laboratory’s (PNNL’s) Independent Oversight (IO) office led an assessment to evaluate PNNL’s approach to tracking and protecting high-value/high-visibility assets. The approach used by the assessment team included a review of requirements (including records), staff interviews, on-site and virtual walkthroughs of lab spaces, review of data, and the development of three separate workflows to capture PNNL’s current practices in the areas of controlled substances, select toxins, and precious metals. Summary results are provided within the report, including all findings and opportunities for improvement (OFIs).

99 GENERAL AND MISCELLANEOUS↗

A Review of Offshore Methane Quantification Methodologies

Since pre-industrial times, anthropogenic methane emissions have increased and are partly responsible for a changing global climate. Natural gas and oil extraction activities are one significant source of anthropogenic methane. While methods have been developed and refined to quantify onshore methane emissions, the ability of methods to directly quantify emissions from offshore production facilities remains largely unknown. Here, we review recent studies that have directly measured emissions from offshore production facilities and critically evaluate the suitability of these measurement strategies for emission quantification in a marine environment. The average methane emissions from production platforms measured using downwind dispersion methods were 32 kg h−1 from 188 platforms; 118 kg h−1 from 104 platforms using mass balance methods; 284 kg h−1 from 151 platforms using aircraft remote sensing; and 19,088 kg h−1 from 10 platforms using satellite remote sensing. Upon review of the methods, we suggest the unusually large emissions, or zero emissions observed could be caused by the effects of a decoupling of the marine boundary layer (MBL). Decoupling can happen when the MBL becomes too deep or when there is cloud cover and results in a stratified MBL with air layers of different depths moving at different speeds. Decoupling could cause: some aircraft remote sensing observations to be biased high (lower wind speed at the height of the plume); the mass balance measurements to be biased high (narrow plume being extrapolated too far vertically) or low (transects miss the plume); and the downwind dispersion measurements much lower than the other methods or zero (plume lofting in a decoupled section of the boundary layer). To date, there has been little research on the marine boundary layer, and guidance on when decoupling happens is not currently available. We suggest an offshore controlled release program could provide a better understanding of these results by explaining how and when stratification happens in the MBL and how this affects quantification methodologies.

Riddick, Stuart N. (ORCID:0000000316841843)↗

Metallic d-wave altermagnetism in WFeB: a platform for electrically switchable perpendicular spin-splitter response

We report the synthesis and magnetic characterization of WFeB and identify it as a metallic d-wave altermagnet representative of a broader TiNiSi-type family. Neutron diffraction, Mössbauer spectroscopy, and magnetometry establish a collinear altermagnetic ordering confirmed by first-principles calculations. The electronic structure shows a nonrelativistic spin splitting of approximately 100 meV, but it also supports a strong spin-splitter transport response. This demonstrates that efficient spin-current generation can occur even with such modest band splitting. Symmetry analysis shows that selected film orientations permit deterministic switching of the Néel vector by current-induced staggered torques, enabling electrical control of a perpendicular spin-splitter response. These results establish WFeB and related TiNiSi-type antiferromagnets as a platform for electrically switchable charge-to-spin conversion driven by altermagnetic symmetry.

FOS: Physical sciences↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Runtime localized cooling of high-performance processors

A plurality of thermal electric cooler (TEC) elements are formed in a TEC grid structure. Control logic dynamically varies a supply current supplied to each TEC element (or group of TEC elements) in the TEC grid based on changes in power density respectively associated with areas cooled by each of the TEC elements or group of TEC elements.

Rao, Karthik↗