Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Decarbonizing Solvent Chemistry Through Microwave Processing [Abstract]

National Energy Technology Laboratory and Covestro LLC. will collaborate on a project titled, “Decarbonizing Solvent Chemistry Through Microwave Processing”, which was selected for funding by DOE’s Office of Energy Efficiency and Renewable Energy (EERE) Industrial Efficiency and Decarbonization Office (IEDO) FOA DE-EE0002997. The project aims to develop a microwave-based approach for low-heat aqueous-based industry-relevant reactions currently conducted using a conventional fossil-energy fueled hydrothermal reactor. The team has combined expertise in the areas of polymer production, microwave assisted reactions and scale-up, and life cycle analysis to perform the tasks proposed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Generating high-resolution total canopy SIF emission from TROPOMI data: Algorithm and application

Solar-induced chlorophyll fluorescence (SIF) is a rapidly advancing front in modeling global terrestrial gross primary production (GPP). Canopy total SIF emissions (SIF total ) are mechanistically linked to the plant photosynthesis, and can be estimated from satellite observed SIF (SIF obs ) through radiative transfer modeling. However, the current satellite SIF obs and thus SIF total are available only at coarse spatial resolutions from several kilometers to tens of kilometers, inhibiting the application at fine spatial scales. Here, in this work, we proposed an algorithm to generate both global high-resolution SIF total (HSIF total ) and high-resolution SIF obs (HSIF obs ) at 1 km from low-resolution SIF obs (LSIF obs ) from the TROPOspheric Monitoring Instrument (TROPOMI), which has a spatial resolution at nadir of 3.5 km by 5.6–7 km. Our statistical method is based on the law of energy conservation and uses satellite derived fraction of absorbed photosynthetically active radiation, fluorescence efficiency, and the escape probability of fluorescence. We evaluated the accuracy of our HSIF total using the Orbiting Carbon Observatory-2 SIF (R 2 = 0.78). We found that the spatial resolution had clear effects on the relationship between HSIF total and GPP. We also compared HSIF total to 8-day averaged tower GPP from 135 flux sites and found that they were better correlated when HSIF total was averaged over a 1-km radius around the tower than when averaged over a larger radius. Our study provided a unique high-resolution HSIF total product, which will advance the estimation of GPP by extrapolating site-level relationships to the global scale.

54 ENVIRONMENTAL SCIENCES↗

Electrification potential of U.S. industrial boilers and assessment of the GHG emissions impact

Electrification is a key strategy for decarbonizing the industrial sector. Industrial process heating, which still relies heavily on fossil fuel combustion and accounts for the majority of sector wide GHG emissions, is a particularly attractive electrification target. Electrifying industrial boilers represents a cross-cutting opportunity for GHG emissions reductions, given their widespread use in most manufacturing industries. Yet, there are gaps in the understanding of the current population of conventional industrial boilers in the United States that preclude a characterization of boiler electrification's technical potential to reduce fuel consumption and GHG emissions. In this study, we develop an up-to-date dataset of the industrial boiler population in the U.S. and quantify the county-level electricity requirements and net changes in fuel use and GHG emissions under the current electric grid and theoretical future grid scenarios. Our results show an increase of 105 MMmtCO 2 e and 73 MMmtCO 2 e in GHG emissions from boiler electrification, with and without the replacement of byproduct fuels, respectively, under the current electric grid, and a reduction of 19 MMmtCO2e and 7 MMmtCO2e in GHG emissions under a future high renewables electric grid. GHG emissions savings are currently possible only in certain regions of the U.S. unless future grids are decarbonized. We also provide discussion that could be useful for policy makers and manufacturing facilities for advancing the electrification of industrial boilers in locations and industries toward fuel savings and GHG emissions reductions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analytical model for balling defects in laser melting using rivulet theory and solidification

In laser welding and additive manufacturing communities, the balling (humping) defect is primarily attributed to the Plateau–Rayleigh fluid instability (PRI) with a few authors suggesting fluid jetting and volume conservation as alternative mechanisms. As analytical descriptions of these mechanisms are unavailable, combining them into a single formalism is unfeasible. We present a new model of PRI with higher accuracy, accounting for competition with solidification, to compare the expected behavior with known experimental trends when fluid jetting is neglected. We adapt a rivulet instability model from fluid physics to account for the stabilizing effects of the substrate, which the traditional cylindrical-jet geometry does not account for and estimate the instability growth rate. Our model yields a continuous transition from non-balling to balling hitherto lacking in current literature and predicts instability growth at higher wavelengths with strong sensitivity to the solidification front curvature. While the fluid surface is most unstable for shallow melt pools, the absolute magnitude of balling relevant to printing defects scales with melt pool depth and has a maximum for a given melt pool geometry. Synchrotron-based x-ray radiography of thin samples indicates that PRI growth rates and solidification can be comparable in magnitude and thus compete, as we find in this work. We predict that deviations between model predictions and our experimental results demonstrate the importance of fluid flows and heat transport in the balling process. Our experiments further demonstrate at least one mechanism by which the melt pool length and the balling wavelength are not equivalent, as commonly claimed.

Taylor, Z. [Stanford Univ., CA (United States); SL↗

1993 Salt Lake City Household Travel Diary Survey

The purpose of the Salt Lake City Household Travel Diary Survey was to gather detailed information about current travel habits in Utah, to serve as the basis for future travel modeling activities, and to inform regional and statewide transportation planning. The survey sampled residents from Weber, Davis, Salt Lake, and Utah counties only. Along with travel data, the survey collected demographic and socioeconomic characteristics for 3,082 households and 8,333 participants.

1Hz data↗

Energy Analysis: Ways to Save Energy and Reduce the Emissions in Wastewater Treatment Plants

The key of this study is to explore the primary energy consumers in wastewater treatment plants, which is considered as one of the major energy consumers, and introduces the best solution to save energy and reduce emissions in these facilities. This study is based on the energy assessment and analyses of eleven wastewater treatment plants. Through the investigation, it was found that plants can save up to 44,158 MWh of the energy consumption which is 47% from the total electricity consumption with a 17% reduction in the total utility bills and that about 2.5 million dollars cost savings after reviewing the currently facilitated energy system. Additionally, an average of five years' payback period resulted in most energy-saving recommendations. A vast potential of greenhouse gas emissions can be reduced with a total range reduction between 13 to 35 million kg of CO 2 based on the speed reduction percentage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Complete quasilinear model for the acceleration-driven lower hybrid drift instability and a computational assessment of its validity

A complete quasilinear model is derived for the electrostatic acceleration-driven lower hybrid drift instability in a uniform two-species low-beta plasma in which current is perpendicular to the background magnetic field. The model consists of coupled nonlinear velocity space diffusion equations for the volume-averaged ion and electron distribution functions. Each species' diffusion coefficient depends on a time-evolving spectral density of the electric-field energy per unit volume and a time-evolving dispersion relation. The dispersion relation is expressed analytically in integral form without the use of asymptotic limits and applies to arbitrary distribution functions, so long as they can be expressed as a function of one velocity coordinate, e.g., f⁡(vy) or f⁡(v⊥). The quasilinear model conserves energy and is complete in that it fully describes the evolution of the distribution functions, including resonant and nonresonant particle-wave interactions, while accounting for distribution-function-dependent mixed-complex frequencies. Further, the quasilinear diffusion model is solved numerically and self-consistently using a Crank-Nicolson temporal discretization and a second-order finite-volume velocity-space discretization. Numerical solutions are compared to nonlinear fourth-order accurate continuum kinetic Vlasov-Poisson simulations. Evolution of electric-field energy, growth rates, distribution functions, and diffusion coefficients are shown to be in agreement with Vlasov simulations. The quasilinear model is shown to predict anomalous transport terms, like resistivity and heating, to within a factor of order unity. Discrepancies between the quasilinear model and Vlasov simulations are assessed and attributed primarily to lack of damping in the quasilinear description and to the use of unperturbed-orbit susceptibilities in the linear theory dispersion relation. The results illuminate the predictive accuracy of the quasilinear model, place approximate bounds on its validity, and provide much needed vetting of quasilinear theory's ability to predict the nonlinear state of a microturbulent plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters - CRADA 625 (Abstract)

Commercial heat pump water heater (CHPWH) systems significantly decarbonize the commercial and multifamily sectors by eliminating the reliance on gas-fired water heating. CHPWH systems are also well suited to include load shift controls that enable load-up and shed commands for supporting grid reliability and time-of-use pricing structure. However, they have not had wide adoption due to factors including price, complexity, and perceived risk. Although CHPWHs have been available in the US for decades, they have not made significant market gains in part because the systems have required significant and costly engineering design expertise and proved lackluster performance. Successful widespread market adoption requires a different approach; a shift from the current custom specialized expertise project design and installation to a repeatable approach that requires little specialized knowledge or expertise and can deliver persistent performance. Using this type of holistic systems approach requires effectively integrating four CHPWH system key components: primary air-to-water heat pumps; primary thermal storage tanks, a temperature maintenance system, and a control system which has capabilities to manage the primary heat pump cycles, any back-up, supplemental, or temperature maintenance heating, alarms, and grid connectivity allowing for demand response (DR), and/or load shifting. The project team has developed and will implement a suite of tools to support faster, less expensive, and more reliable field installations of CHPWH technology and with the resulting data used to further improve the tool set. These tools include: (1) A tool for optimizing system size and costs. (2) A tool that predicts annual energy use and overall system efficiency. (3) The Advanced Water Heater Specification (AWHS 8.0) defining the components of a full CHPWH system addressing performance requirements by climate zone. (4) The Qualified Products List: (QPL) of approved products that meet the specifications requirements. (5) Training materials including online on-demand modules, instructor-led training, and virtual interactive video tours of CHPWH installations in multifamily buildings. Demonstration site identification in low-income buildings in underserved communities is currently underway. Preliminarily, the team anticipates having three demonstrations in the Pacific Northwest and three in the Northeast for a total of six sites. After the demonstration sites are finalized, and M&V instrumentation installations are complete, the team will gather performance data and confirm whether the CHPWH systems perform as predicted and use the data to improve the existing tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Federal Metering Guidance

The Federal Metering Guidance documents the metering provisions in EO 13834, Efficient Federal Operations and other metering related statutory requirements. This document provides the meter-related reporting requirements for Federal agencies, specifies a method to verify the existence of currently installed building-level meters, provides guidelines on prioritizing the implementation of advanced energy and water meters, sets the schedule for agencies to update their five-year metering plans, provides the minimum requirements that agencies must meet when updating their five-year metering plans along with recommend elements for an effective plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Levelized Cost of Charging Electric Vehicles

This data set includes the levelized cost of charging (LCOC) and lifetime fuel cost savings (LFCS) values as reported in "Levelized Cost of Charging of Electric Vehicles in the United States." Values are reported at the state and national levels for battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs). The data set also includes the four annual direct current fast charging (DCFC) station load profiles used to approximate the levelized cost of DCFC charging. Each profile provides 15-min resolved power requirements for one full year. Borlaug, B., Salisbury, S., Gerdes, M., and Muratori, M., Levelized Cost of Charging Electric Vehicles in the United States, Joule (2020), https://doi.org/10.1016/j.joule.2020.05.013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Levelized Cost of Charging Electric Vehicles

This data set includes the levelized cost of charging (LCOC) and lifetime fuel cost savings (LFCS) values as reported in "Levelized Cost of Charging of Electric Vehicles in the United States." Values are reported at the state and national levels for battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs). The data set also includes the four annual direct current fast charging (DCFC) station load profiles used to approximate the levelized cost of DCFC charging. Each profile provides 15-min resolved power requirements for one full year. Borlaug, B., Salisbury, S., Gerdes, M., and Muratori, M., Levelized Cost of Charging Electric Vehicles in the United States, Joule (2020), https://doi.org/10.1016/j.joule.2020.05.013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Thawing Permafrost on Residential Infrastructure: Results and Resources

Permafrost underlies approximately 20% of the landmass in the Northern Hemisphere. Inevitably human infrastructure has been and will be built on permafrost; however, due to climate change, the permafrost in many regions has begun to thaw. Using past reports and surveys as guidance, a survey was conducted to track the effects of permafrost thaw on housing infrastructure in the community of Point Lay, Alaska. The Cold Climate Housing Research Center, Inc. and the National Renewable Energy Lab conducted a literature review and interviews to document community issues from thawing permafrost and identify potential mitigation strategies for existing and new infrastructure. Researchers also identified strategies for individual homeowners to inspect their foundations for current issues or anticipate future ones. This poster will cover the results from the survey on the effects of permafrost thawing to Point Lay and include permafrost basics, common concerns from thawing permafrost, steps to identify permafrost sites and visible signs of permafrost degradation, and potential mitigation strategies that may be beneficial to Alaskans and increase resilience in the Arctic.

Alaska↗

Investigations of the stability of GaAs for photoelectrochemical H 2 evolution in acidic or alkaline aqueous electrolytes

The long-term stability of p-GaAs photocathodes has been investigated for the hydrogen-evolution reaction (HER) in contact with either 1.0 M H 2 SO 4 (aq) or 1.0 M KOH(aq). Stability for the HER was evaluated using p-GaAs electrodes that were either etched or coated with active HER catalysts (Pt and CoP). Changes in surface characteristics of GaAs after exposure to electrochemical conditions were monitored by X-ray photoelectron spectroscopy (XPS), and electrode dissolution processes were evaluated by inductively coupled plasma mass spectrometry (ICP-MS). Consistent with thermodynamic predictions, after operation of the HER at pH 0 or pH 14, illuminated etched p-GaAs electrodes exhibited minimal dissolution while preserving a nearly stoichiometric surface. Electrodeposition or sputtering of Pt on the p-GaAs surface promoted the formation of excess As 0 via an interfacial reaction during the HER. The resulting non-stoichiometric As 0 -rich surface of p-GaAs/Pt electrodes caused a loss in photoactivity as well as substantial cathodic dark current. In contrast, p-GaAs electrodes coated with thin-film CoP catalysts did not display an increase in surficial As 0 after operation of the HER in acidic electrolytes. Minimization of deleterious interfacial reactions is thus critical to obtain extended stability in conjunction with high performance from p-GaAs photocathodes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Organizational and psychological measures for data center energy efficiency: barriers and mitigation strategies

Abstract It was last estimated that in 2020, data centers comprised approximately 2% of total US electricity consumption, with an estimated annual growth rate of 4%. As our country increasingly relies on information technology (IT), our data centers (DCs) will need to increase their energy efficiency (EE) to stabilize their energy consumption. The task of studying EE in DCs is complicated by the interconnected nature of humans and mission-critical technical systems. Moreover, the literature tends to focus on technology solutions such as improvements to IT equipment, cooling infrastructure, and software, without addressing organizational and psychological drivers. Our research demystifies the complex interactions between humans and DCs, by asking What non-technical barriers impede EE investment decision-making and/or implementing energy management strategies? To begin to answer this question, we perform a literature review of 86 resources, ranging from peer-reviewed journal publications to handbooks. We also consider related fields such as organizational behavioral management and energy intensive buildings. We develop a public Zotero library, perform content coding, and complete a rudimentary network analysis. Our findings from the literature review suggest that (1) technological solutions are abundant in the literature but fall short of providing practical guidance on the pitfalls of implementation, (2) making energy efficiency a priority at the executive level of organizations will be largely ineffective if the IT and facilities staff are not directly incentivized to increase EE, and (3) there is minimal current understanding of how the individual psychologies of IT and facilities staff affect EE implementation in DCs. In the next phase of our research, we plan to interview data center operators/experts to ground-truth our literature findings and collaboratively design decarbonization policy solutions that target organizational structure, empower individual staff, and foster a supportive external market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot Study for Multifamily Building Ventilation and Indoor Air Quality

Weatherization Program Notice (WPN) 17-7 issued by the US Department of Energy (DOE) Weatherization Assistance Program (WAP) requires that buildings have ventilation in accordance with ASHRAE Standard 62.2-2016 (entitled Ventilation and Indoor Air Quality in Residential Buildings) in dwelling units weatherized under the program. The 2016 version of the standard expanded its scope of application to include all multifamily dwelling units. This has resulted in concerns for buildings where installing ventilation in individual units is costly or otherwise logistically difficult. Also, excessive ventilation rates could significantly increase energy costs, and may cause indoor air quality issues within the buildings. One deficiency that is noted is that the standard does not provide a credit for existing infiltration in multifamily buildings that reduces the required mechanical ventilation levels. This report details findings from a field study investigating envelope air-tightness, inter-unit connectivity, and indoor air quality in centrally ventilated high-rise multifamily buildings with central ventilation systems serving individual units in the state of New York. As allowed under WPN 17-7, the State of New York has a variance in the application of ASHRAE Standard 62.2-2016 in select types of multifamily buildings to provide time to determine how best to implement the standard. The purpose of this pilot study is to characterize the impact that weatherization and feasible ventilation improvements have on the indoor air quality of large, multifamily buildings with centrally ventilated apartments, as currently performed under WAP in the State of New York under their variance request (i.e., to implement ASHRAE Standard 62.2-2016 “to the greatest extent possible” in this type of multifamily building). A major goal is to determine if these practices improve or at least “do no harm” to the indoor air quality of the weatherized multifamily buildings and to the occupants themselves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Status Report on Thermal Delivery Modeling in HYBRID

This report details the modeling efforts consistent with the HYBRID repository of the Integrated Energy Systems (IES) program, motivated to develop information data tables characterizing the thermodynamic losses associated with transporting thermal energy over large distances. The described model establishes a methodology to currently characterize the impacts of certain parameters such as distance, piping geometry, and heat transfer fluid among others as well as sets up ability to interconnect the delivery model into Modelica IES simulations in the future. This report describes the modeling efforts completed and describes some of the future studies that will be done using results produced by the modeling efforts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bulk Spray and Individual Plume Characterization of LPG and Iso-Octane Sprays at Engine-Like Conditions

This study presents experimental and numerical examination of directly injected (DI) propane and iso-octane, surrogates for liquified petroleum gas (LPG) and gasoline, respectively, at various engine like conditions with the overall objective to establish the baseline with regards to fuel delivery required for future high efficiency DI-LPG fueled heavy-duty engines. Sprays for both iso-octane and propane were characterized and the results from the optical diagnostic techniques including high-speed Schlieren and planar Mie scattering imaging were applied to differentiate the liquid-phase regions and the bulk spray phenomenon from single plume behaviors. The experimental results, coupled with high-fidelity internal nozzle-flow simulations were then used to define best practices in CFD Lagrangian spray models. Optical imaging revealed that unlike iso-octane, propane’s spray propagation was fed by its flash boiling, spray collapse, and high degree of vaporization, resulting in a direct proportionality of propane’s penetration length to temperature. These unique features of propane and its variation from iso-octane’s spray pattern, contributed to its classification as an unconventional spray. Appropriate corrections to the injection and breakup models were developed to reproduce the under-expanded jet dynamics and to mimic the flash boiling-driven spray development observed with propane sprays. The simulation results were found to be sensitive to cone and inclusion angles of the blob injector. The current work represents a first assessment of the capability of the commonly available models for engine-spray simulations and highlights the fact that, despite the reasonable agreement obtained in the fuel vapor morphology, the representation of the liquid phase lacks accuracy and requires further model development.

02 PETROLEUM↗