Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Lattice corrections to the quark quasidistribution at one loop

Here, we calculate radiative corrections to the quark quasidistribution in lattice perturbation theory at one loop to leading orders in the lattice spacing. We also consider one-loop corrections in continuum Euclidean space. We find that the infrared behavior of the corrections in Euclidean and Minkowski space are different. Furthermore, we explore features of momentum loop integrals and demonstrate why loop corrections from the lattice perturbation theory and Euclidean continuum do not correspond with their Minkowski brethren, and comment on a recent suggestion for transcending the differences in the results. Finally, we examine the role of the lattice spacing a and of the r parameter in the Wilson action in these radiative corrections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automated correction of phase errors in the Advanced Photon Source linac.

Maintaining stable phasing in a linear accelerator is crucial for maintaining optimal performance. If phasing is incorrect, the beam will in general have an energy error and increased energy spread. While an energy error can be readily detected and corrected using position readings from beam position monitors at dispersion locations, this method is not useful for correcting energy spread in a system with many possible phase errors. While energy spread can be corrected by looking at beam size at a dispersive location, this typically involves a beam-intercepting diagnostic and is not compatible with top-up operation. Uncorrected energy spread results in poor capture efficiency in downstream accelerators, such as the Advanced Photon Source (APS) particle accumulator ring or booster synchrotron. To address this issue, APS has implemented beam-to-rf phase detectors in the linac, along with software for automatic correction of phase errors. We discuss the design, implementation, and performance of these detectors, as well as their use in feedback to automatically correct linac phase errors during top-up operation.

43 PARTICLE ACCELERATORS↗

Quasiprobabilistic Readout Correction of Midcircuit Measurements for Adaptive Feedback via Measurement Randomized Compiling

Quantum measurements are a fundamental component of quantum computing. However, on present-day quantum computers, measurements can be more error prone than quantum gates and are susceptible to nonunital errors as well as nonlocal correlations due to measurement crosstalk. While readout errors can be mitigated in postprocessing, this is inefficient in the number of qubits due to a combinatorially large number of possible states that need to be characterized. In this work, we show that measurement errors can be tailored into a simple stochastic error model using randomized compiling, enabling the efficient mitigation of readout errors via quasiprobability distributions reconstructed from the measurement of a single preparation state in an exponentially large confusion matrix. We demonstrate the scalability and power of this approach by correcting readout errors without matrix inversion on a large number of different preparation states applied to a register of eight superconducting transmon qubits. Moreover, we show that this method can be extended to midcircuit measurements used for active feedback via quasiprobabilistic error cancellation, and we demonstrate the correction of measurement errors on an ancilla qubit used to detect and actively correct bit-flip errors on an entangled memory qubit. Our approach enables the correction of readout errors on large numbers of qubits and offers a strategy for correcting readout errors in adaptive circuits in which the results of midcircuit measurements are used to perform conditional operations on nonlocal qubits in real time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A refraction correction for buried interfaces applied to in situ grazing-incidence X-ray diffraction studies on Pd electrodes

In situ characterization of electrochemical systems can provide deep insights into the structure of electrodes under applied potential. Grazing-incidence X-ray diffraction (GIXRD) is a particularly valuable tool owing to its ability to characterize the near-surface structure of electrodes through a layer of electrolyte, which is of paramount importance in surface-mediated processes such as catalysis and adsorption. Corrections for the refraction that occurs as an X-ray passes through an interface have been derived for a vacuum–material interface. In this work, a more general form of the refraction correction was developed which can be applied to buried interfaces, including liquid–solid interfaces. Furthermore, the correction is largest at incidence angles near the critical angle for the interface and decreases at angles larger and smaller than the critical angle. Effective optical constants are also introduced which can be used to calculate the critical angle for total external reflection at the interface. This correction is applied to GIXRD measurements of an aqueous electrolyte–Pd interface, demonstrating that the correction allows for the comparison of GIXRD measurements at multiple incidence angles. This work improves quantitative analysis of d-spacing values from GIXRD measurements of liquid–solid systems, facilitating the connection between electrochemical behavior and structure under in situ conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of Subhourly Clipping Loss Error Corrections

Under-performance of solar PV systems is an important issue that increases risks for stakeholders, including developers, investors and operators. Recently some attention has focused on underestimation of inverter clipping losses as a possible source of over-prediction where sub-hourly solar variability is high. Several models and data sets have been analyzed over the past few years, with the aim of quantifying, predicting, and correcting underestimated clipping loss errors for systems with high DC/AC ratio and solar variability. In this research, we apply a machine learning model developed at NREL to two physical PV systems, to correct for subhourly clipping losses. For each system, we compare overall AC power output for the model taken at 1-minute intervals to AC power output taken at 1-hour intervals with the addition of the subhourly clipping correction. Our findings consistently show that the addition of the clipping loss correction lead to a reduction in mean bias error of 0.8% and 1.2% for systems A and B, respectively, with no additional filtering applied. When examining high solar variability periods where clipping is more pronounced, system A and B experienced a 1.8% and 2.7% reduction in mean bias error, respectively, when the clipping correction was applied.

machine learning↗

Radiochromic film dosimetry with flatbed scanners: A fast and accurate method for dose calibration and uniformity correction with single film exposure

Film dosimetry is an attractive tool for dose distribution verification in intensity modulated radiotherapy (IMRT). A critical aspect of radiochromic film dosimetry is the scanner used for the readout of the film: the output needs to be calibrated in dose response and corrected for pixel value and spatial dependent nonuniformity caused by light scattering; these procedures can take a long time. A method for a fast and accurate calibration and uniformity correction for radiochromic film dosimetry is presented: a single film exposure is used to do both calibration and correction. Gafchromic EBT films were read with two flatbed charge coupled device scanners (Epson V750 and 1680Pro). The accuracy of the method is investigated with specific dose patterns and an IMRT beam. The comparisons with a two-dimensional array of ionization chambers using a 18x18 cm{sup 2} open field and an inverse pyramid dose pattern show an increment in the percentage of points which pass the gamma analysis (tolerance parameters of 3% and 3 mm), passing from 55% and 64% for the 1680Pro and V750 scanners, respectively, to 94% for both scanners for the 18x18 open field, and from 76% and 75% to 91% for the inverse pyramid pattern. Application to an IMRT beam also shows better gamma index results, passing from 88% and 86% for the two scanners, respectively, to 94% for both. The number of points and dose range considered for correction and calibration appears to be appropriate for use in IMRT verification. The method showed to be fast and to correct properly the nonuniformity and has been adopted for routine clinical IMRT dose verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Semi-empirical procedures for correcting detector size effect on clinical MV x-ray beam profiles

The measured radiation beam profiles need to be corrected for the detector size effect to derive the real profiles. This paper describes two new semi-empirical procedures to determine the real profiles of high-energy x-ray beams by removing the detector size effect from the measured profiles. Measured profiles are corrected by shifting the position of each measurement point by a specific amount determined from available theoretical and experimental knowledge in the literature. The authors developed two procedures to determine the amount of shift. In the first procedure, which employs the published analytical deconvolution procedure of other investigators, the shift is determined from the comparison of the analytical fit of the measured profile and the corresponding analytical real profile derived from the deconvolution of the fitted measured profile and the Gaussian detector response function. In the second procedure, the amount of shift at any measurement point is considered to be proportional to the value of an analytical function related to the second derivative of the real profile at that point. The constant of proportionality and a parameter in the function are obtained from the values of the shifts at the 90%, 80%, 20%, and 10% dose levels, which are experimentally known from the published results of other investigators to be approximately equal to half of the radius of the detector. These procedures were tested by correcting the profiles of 6 and 18 MV x-ray beams measured by three different ionization chambers and a stereotactic field diode detector with 2.75, 2, 1, and 0.3 mm radii of their respective active cylindrical volumes. The corrected profiles measured by different detectors are found to be in close agreement. The detector size corrected penumbra widths also agree with the expected values based on the results of an earlier investigation. Thus, the authors concluded that the proposed procedures are accurate and can be used to derive the real profiles of clinical high-energy x-ray beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of respiratory and cardiac motion correction schemes in dual gated PET/CT cardiac imaging

Purpose: Cardiac imaging suffers from both respiratory and cardiac motion. One of the proposed solutions involves double gated acquisitions. Although such an approach may lead to both respiratory and cardiac motion compensation there are issues associated with (a) the combination of data from cardiac and respiratory motion bins, and (b) poor statistical quality images as a result of using only part of the acquired data. The main objective of this work was to evaluate different schemes of combining binned data in order to identify the best strategy to reconstruct motion free cardiac images from dual gated positron emission tomography (PET) acquisitions. Methods: A digital phantom study as well as seven human studies were used in this evaluation. PET data were acquired in list mode (LM). A real-time position management system and an electrocardiogram device were used to provide the respiratory and cardiac motion triggers registered within the LM file. Acquired data were subsequently binned considering four and six cardiac gates, or the diastole only in combination with eight respiratory amplitude gates. PET images were corrected for attenuation, but no randoms nor scatter corrections were included. Reconstructed images from each of the bins considered above were subsequently used in combination with an affine or an elastic registration algorithm to derive transformation parameters allowing the combination of all acquired data in a particular position in the cardiac and respiratory cycles. Images were assessed in terms of signal-to-noise ratio (SNR), contrast, image profile, coefficient-of-variation (COV), and relative difference of the recovered activity concentration. Results: Regardless of the considered motion compensation strategy, the nonrigid motion model performed better than the affine model, leading to higher SNR and contrast combined with a lower COV. Nevertheless, when compensating for respiration only, no statistically significant differences were observed in the performance of the two motion models considered. Superior image SNR and contrast were seen using the affine respiratory motion model in combination with the diastole cardiac bin in comparison to the use of the whole cardiac cycle. In contrast, when simultaneously correcting for cardiac beating and respiration, the elastic respiratory motion model outperformed the affine model. In this context, four cardiac bins associated with eight respiratory amplitude bins seemed to be adequate. Conclusions: Considering the compensation of respiratory motion effects only, both affine and elastic based approaches led to an accurate resizing and positioning of the myocardium. The use of the diastolic phase combined with an affine model based respiratory motion correction may therefore be a simple approach leading to significant quality improvements in cardiac PET imaging. However, the best performance was obtained with the combined correction for both cardiac and respiratory movements considering all the dual-gated bins independently through the use of an elastic model based motion compensation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-QI-03: Compartment Modeling of Dynamic Brain PET - The Effect of Scatter and Random Corrections On Parameter Errors

Purpose: To investigate the effects of corrections for random and scattered coincidences on kinetic parameters in brain tumors, by using ten Monte Carlo (MC) simulated dynamic FLT-PET brain scans. Methods: The GATE MC software was used to simulate ten repetitions of a 1 hour dynamic FLT-PET scan of a voxelized head phantom. The phantom comprised six normal head tissues, plus inserted regions for blood and tumor tissue. Different time-activity-curves (TACs) for all eight tissue types were used in the simulation and were generated in Matlab using a 2-tissue model with preset parameter values (K1,k2,k3,k4,Va,Ki). The PET data was reconstructed into 28 frames by both ordered-subset expectation maximization (OSEM) and 3D filtered back-projection (3DFBP). Five image sets were reconstructed, all with normalization and different additional corrections C (A=attenuation, R=random, S=scatter): Trues (AC), trues+randoms (ARC), trues+scatters (ASC), total counts (ARSC) and total counts (AC). Corrections for randoms and scatters were based on real random and scatter sinograms that were back-projected, blurred and then forward projected and scaled to match the real counts. Weighted non-linearleast- squares fitting of TACs from the blood and tumor regions was used to obtain parameter estimates. Results: The bias was not significantly different for trues (AC), trues+randoms (ARC), trues+scatters (ASC) and total counts (ARSC) for either 3DFBP or OSEM (p<0.05). Total counts with only AC stood out however, with an up to 160% larger bias. In general, there was no difference in bias found between 3DFBP and OSEM, except in parameter Va and Ki. Conclusion: According to our results, the methodology of correcting the PET data for randoms and scatters performed well for the dynamic images where frames have much lower counts compared to static images. Generally, no bias was introduced by the corrections and their importance was emphasized since omitting them increased bias extensively.

60 APPLIED LIFE SCIENCES↗

TU-F-18C-01: Breast Tissue Decomposition Using Spectral CT After Distortion Correction

Purpose: To investigate the feasibility of accurate breast tissue compositional characterization by using spectral-distortion-corrected dual energy images from a photon-counting spectral CT. Methods: Thirty eight postmortem breasts were imaged with a Cadmium-Zinc-Telluride (CZT)-based photon-counting spectral CT system at beam energy of 100 kVp. The energy-resolved detector sorted photons into low and high energy bins with a splitting energy of 42 keV. The estimated mean glandular dose (MGD) for each breast was approximately 2.0 mGy. Dual energy technique was used to decompose breast tissue into water, lipid, and protein contents. Two image-based methods were investigated to improve the accuracy of tissue compositional characterization. The first method simply limited the recorded spectra up to 90 keV. This reduced the pulse pile-up artifacts but it has some dose penalty. The second method corrected the spectral information of all measured photons by using a spectral distortion correction technique. Breasts were then chemically decomposed into their respective water, lipid, and protein contents, which was used as the reference standard. The accuracy of the tissue compositional measurement with spectral CT was evaluated by the root-mean-square (RMS) errors in percentage composition. Results: The errors in quantitative material decomposition were significantly reduced after the appropriate image processing methods. As compared to the chemical analysis as the reference standard, the averages of the RMS errors were estimated to be 15.5%, 3.3%, and 2.8% for the raw, energy-limited, and spectral-corrected images, respectively. Conclusion: Spectral CT can be used to accurately quantify the water, lipid, and protein contents in breast tissues by implementing a spectral distortion correction algorithm. The tissue compositional information can potentially improve the sensitivity and specificity for breast cancer diagnosis.

60 APPLIED LIFE SCIENCES↗

Sci—Fri AM: Mountain — 01: Validation of a new formulism and the related correction factors on output factor determination for small photon fields

Small field dosimetry measurements including output factors are difficult due to lack of charged-particle equilibrium, occlusion of the radiation source, the finite size of detectors, and non-water equivalence of detector components. With available detectors significant variations could be measured that will lead to incorrect delivered dose to patients. IAEA/AAPM have provided a framework and formulation to correct the detector response in small photon fields. Monte Carlo derived correction factors for some commonly used small field detectors are now available, however validation has not been performed prior to this study. An Exradin A16 chamber, EDGE detector and SFD detector were used to perform the output factor measurement for a series of conical fields (5–30mm) on a Varian iX linear accelerator. Discrepancies up to 20%, 10% and 6% were observed for 5, 7.5 and 10 mm cones between the initial output factors measured by the EDGE detector and the A16 ion chamber, while the discrepancies for the conical fields larger than 10 mm were less than 4%. After the application of the correction, the output factors agree well with each other to within 1%. Caution is needed when determining the output factors for small photon fields, especially for fields 10 mm in diameter or smaller. More than one type of detector should be used, each with proper corrections applied to the measurement results. It is concluded that with the application of correction factors to appropriately chosen detectors, output can be measured accurately for small fields.

60 APPLIED LIFE SCIENCES↗

Correcting lateral response artifacts from flatbed scanners for radiochromic film dosimetry

Purpose: A known factor affecting the accuracy of radiochromic film dosimetry is the lateral response artifact (LRA) induced by nonuniform response of a flatbed scanner in the direction perpendicular to the scan direction. This work reports a practical solution to eliminate such artifacts for all forms of dose QA. Methods: EBT3 films from a single production lot (02181401) cut into rectangular 4 × 5 cm{sup 2} pieces, with the long dimension parallel to the long dimension of the original 20.3 × 25.4 cm{sup 2} sheets, were exposed at a depth of 5 cm on a Varian Trilogy at the center of a 20 × 20 cm{sup 2} open field at seven doses between 50 and 1600 cGy using 6 MV photons. These films together with an unexposed film from the same production lot were lined one next to the other on an Epson 10000XL or 11000XL scanner in portrait orientation with their long dimension parallel to the scan direction. Scanned images were then obtained with the line of films positioned at seven discrete lateral locations perpendicular to the scan direction. The process was repeated in landscape orientation and on three other Epson scanners. Data were also collected for three additional production lots of EBT3 film (11051302, 03031401, and 03171403). From measurements at the various lateral positions, the scanner response was determined as a function of the lateral position of the scanned film. For a given color channel X, the response at any lateral position L is related to the response at the center, C, of the scanner by Response(C, D, X) = A{sub L,X} + B{sub L,X}⋅Response(L, D, X), where D is dose and the coefficients A{sub L,X} and B{sub L,X} are determined from the film measurements at the center of the scanner and six other discrete lateral positions. The values at intermediate lateral positions were obtained by linear interpolation. The coefficients were determined for the red, green, and blue color channels, preserving the ability to apply triple-channel dosimetry once corrections were applied to compensate for the lateral position response artifact. To validate this method, corrections were applied to several films that were exposed to 15 × 15cm{sup 2} open fields and large IMRT and VMAT fields and scanned at the extreme edges of the scan window in addition to the central location. Calibration and response data were used to generate dose maps and perform gamma analysis using single- or triple-channel dosimetry with FilmQAPro 2014 software. Results: The authors’ study found that calibration curves at the different lateral positions could be correlated by a simple two-point rescaling using the response for unexposed film as well as the response of film exposed at high doses between 800 and 1600 cGy. The coefficients A{sub L,X} and B{sub L,X} for each color channel X were found to be independent of dose at each lateral location L. This made it possible to apply the relationship Response(C, D, X) = A{sub L,X} + B{sub L,X}⋅Response(L, D, X), to the raw film responses, permitting correction of the response values at any lateral position to an equivalent response, as if that part of the film was located at the center of the scanner. This correction method was validated for several films exposed to open as well as large IMRT and VMAT fields. Conclusions: The work reported elaborates on the process using the correction procedures to eliminate the lateral response artifact and demonstrates improvements in the accuracy of radiochromic film dosimetry for the radiation therapy quality assurance applications.

07 ISOTOPE AND RADIATION SOURCES↗

Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal imaging routines including different standard MRI sequences.

60 APPLIED LIFE SCIENCES↗

Radiative corrections: from medium to high energy experiments

Abstract Radiative corrections are crucial for modern high-precision physics experiments, and are an area of active research in the experimental and theoretical community. Here we provide an overview of the state of the field of radiative corrections with a focus on several topics: lepton–proton scattering, QED corrections in deep-inelastic scattering, and in radiative light-hadron decays. Particular emphasis is placed on the two-photon exchange, believed to be responsible for the proton form-factor discrepancy, and associated Monte-Carlo codes. We encourage the community to continue developing theoretical techniques to treat radiative corrections, and perform experimental tests of these corrections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deep Learning-based Non-Stationary Bias Correction (NSBC)

This work develops the NSBC (non-stationary bias correction) methodology to correct temperature projection bias from E3SM. The NSBC deep learning framework consists of a three-part architecture: an auto-encoder for compressing the spatial information, an LSTM for predicting annual temperature mean, and a U-Net for capturing the residual bias in temperature. The non-stationary bias correction (NSBC) framework can correct the non-stationarity of the biases of the climate models, which significantly improves the accuracy of future temperature prediction and improves the overestimation of extreme high temperatures that many existing bias correction methods suffer from. Getting started 1. Obtain the historical climate simulation and observation data. The E3SM simulation data are available through https://aims2.llnl.gov/search/cmip6/. The pseudo observations, the Geophysical Fluid Dynamics Laboratory (GFDL)-ESM4 model (Krasting et al., 2018) are available through https://aims2.llnl.gov/search/cmip6/. The spatial resolution of E3SM and pseudo observation datasets are both regridded to a common 1° resolution grid using conservative interpolation. The regridded E3SM and pseudo observation with 1° resolution can be found throught ./data/. 2. Train the Auto-encoder model. Python 0-autoencoder.py 3. Train the LSTM Python 1-LSTM.py 4. Generate the annual mean temperature based on trained LSTM Python 2-generate_annual_mean_LSTM.py 5. Train the U-Net. Python 3-unet.py 6. Evaluation and compared with the baseline Python 4_evaluation.py Is there a deadline approaching that requires the release of yo

Lucas, Donald↗

Lightweight and Statistical Techniques for Petascale Debugging: Correctness on Petascale Systems (CoPS) Preliminry Report

Petascale platforms with O(10{sup 5}) and O(10{sup 6}) processing cores are driving advancements in a wide range of scientific disciplines. These large systems create unprecedented application development challenges. Scalable correctness tools are critical to shorten the time-to-solution on these systems. Currently, many DOE application developers use primitive manual debugging based on printf or traditional debuggers such as TotalView or DDT. This paradigm breaks down beyond a few thousand cores, yet bugs often arise above that scale. Programmers must reproduce problems in smaller runs to analyze them with traditional tools, or else perform repeated runs at scale using only primitive techniques. Even when traditional tools run at scale, the approach wastes substantial effort and computation cycles. Continued scientific progress demands new paradigms for debugging large-scale applications. The Correctness on Petascale Systems (CoPS) project is developing a revolutionary debugging scheme that will reduce the debugging problem to a scale that human developers can comprehend. The scheme can provide precise diagnoses of the root causes of failure, including suggestions of the location and the type of errors down to the level of code regions or even a single execution point. Our fundamentally new strategy combines and expands three relatively new complementary debugging approaches. The Stack Trace Analysis Tool (STAT), a 2011 R&D 100 Award Winner, identifies behavior equivalence classes in MPI jobs and highlights behavior when elements of the class demonstrate divergent behavior, often the first indicator of an error. The Cooperative Bug Isolation (CBI) project has developed statistical techniques for isolating programming errors in widely deployed code that we will adapt to large-scale parallel applications. Finally, we are developing a new approach to parallelizing expensive correctness analyses, such as analysis of memory usage in the Memgrind tool. In the first two years of the project, we have successfully extended STAT to determine the relative progress of different MPI processes. We have shown that the STAT, which is now included in the debugging tools distributed by Cray with their large-scale systems, substantially reduces the scale at which traditional debugging techniques are applied. We have extended CBI to large-scale systems and developed new compiler based analyses that reduce its instrumentation overhead. Our results demonstrate that CBI can identify the source of errors in large-scale applications. Finally, we have developed MPIecho, a new technique that will reduce the time required to perform key correctness analyses, such as the detection of writes to unallocated memory. Overall, our research results are the foundations for new debugging paradigms that will improve application scientist productivity by reducing the time to determine which package or module contains the root cause of a problem that arises at all scales of our high end systems. While we have made substantial progress in the first two years of CoPS research, significant work remains. While STAT provides scalable debugging assistance for incorrect application runs, we could apply its techniques to assertions in order to observe deviations from expected behavior. Further, we must continue to refine STAT's techniques to represent behavioral equivalence classes efficiently as we expect systems with millions of threads in the next year. We are exploring new CBI techniques that can assess the likelihood that execution deviations from past behavior are the source of erroneous execution. Finally, we must develop usable correctness analyses that apply the MPIecho parallelization strategy in order to locate coding errors. We expect to make substantial progress on these directions in the next year but anticipate that significant work will remain to provide usable, scalable debugging paradigms.

97 MATHEMATICS AND COMPUTING↗

Re-visit local coupling correction in the interaction regions of RHIC

In this article we will re-visit the local coupling correction in the interaction regions (IRs) of the Relativistic Heavy Ion Collider (RHIC). We will review the measurement data of triplet quadrupole rolls, the local coupling correction strengths in the RHIC control system, and the methods for the local coupling correction with local skew quadrupole correctors. Based on the in-turnnel measurement data of triplet roll errors in 2011, we will analytically calculate and simulate IR-bump method to find out the local skew correction strengths and compare them at store and at injection with the Blue and Yellow ring lattices in the 2011 polarized proton (p-p) and Au-Au runs. The vertical dispersion from the triplet roll errors, local and global coupling correction skew quadrupoles, and the vertical dipole correctors are calculated and discussed.

43 PARTICLE ACCELERATORS↗

Re-Visit Local Coupling Correction in the Interaction Regions of RHIC

In this article we will re-visit the local coupling correction in the interaction regions (IRs) of the Relativistic Heavy Ion Collider (RHIC). We will review the measurement data of triplet quadrupole rolls, the local coupling correction strengths in the RHIC control system, and the methods for the local coupling correction with local skew quadrupole correctors. Based on the in-turnnel measurement data of triplet roll errors in 2011, we will analytically calculate and simulate IR-bump method to find out the local skew correction strengths and compare them at store and at injection with the Blue and Yellow ring lattices in the 2011 polarized proton (p-p) and Au-Au runs. The vertical dispersion from the triplet roll errors, local and global coupling correction skew quadrupoles, and the vertical dipole correctors are calculated and discussed.

43 PARTICLE ACCELERATORS↗