Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

MO-FG-CAMPUS-JeP1-05: Water Equivalent Path Length Calculations Using Scatter-Corrected Head and Neck CBCT Images to Evaluate Patients for Adaptive Proton Therapy

Purpose: To establish a method to evaluate the dosimetric impact of anatomic changes in head and neck patients during proton therapy by using scatter-corrected cone-beam CT (CBCT) images. Methods: The water equivalent path length (WEPL) was calculated to the distal edge of PTV contours by using tomographic images available for six head and neck patients received photon therapy. The proton range variation was measured by calculating the difference between the distal WEPLs calculated with the planning CT and weekly treatment CBCT images. By performing an automatic rigid registration, six degrees-of-freedom (DOF) correction was made to the CBCT images to account for the patient setup uncertainty. For accurate WEPL calculations, an existing CBCT scatter correction algorithm, whose performance was already proven for phantom images, was calibrated for head and neck patient images. Specifically, two different image similarity measures, mutual information (MI) and mean square error (MSE), were tested for the deformable image registration (DIR) in the CBCT scatter correction algorithm. Results: The impact of weight loss was reflected in the distal WEPL differences with the aid of the automatic rigid registration reducing the influence of patient setup uncertainty on the WEPL calculation results. The WEPL difference averaged over distal area was 2.9 ± 2.9 (mm) across all fractions of six patients and its maximum, mostly found at the last available fraction, was 6.2 ± 3.4 (mm). The MSE-based DIR successfully registered each treatment CBCT image to the planning CT image. On the other hand, the MI-based DIR deformed the skin voxels in the planning CT image to the immobilization mask in the treatment CBCT image, most of which was cropped out of the planning CT image. Conclusion: The dosimetric impact of anatomic changes was evaluated by calculating the distal WEPL difference with the existing scatter-correction algorithm appropriately calibrated. Jihun Kim, Yang-Kyun Park, Gregory Sharp, and Brian Winey have received grant support from the NCI Federal Share of program income earned by Massachusetts General Hospital on C06 CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

WE-AB-207A-08: BEST IN PHYSICS (IMAGING): Advanced Scatter Correction and Iterative Reconstruction for Improved Cone-Beam CT Imaging On the TrueBeam Radiotherapy Machine

Purpose: To improve CBCT image quality for image-guided radiotherapy by applying advanced reconstruction algorithms to overcome scatter, noise, and artifact limitations Methods: CBCT is used extensively for patient setup in radiotherapy. However, image quality generally falls short of diagnostic CT, limiting soft-tissue based positioning and potential applications such as adaptive radiotherapy. The conventional TrueBeam CBCT reconstructor uses a basic scatter correction and FDK reconstruction, resulting in residual scatter artifacts, suboptimal image noise characteristics, and other artifacts like cone-beam artifacts. We have developed an advanced scatter correction that uses a finite-element solver (AcurosCTS) to model the behavior of photons as they pass (and scatter) through the object. Furthermore, iterative reconstruction is applied to the scatter-corrected projections, enforcing data consistency with statistical weighting and applying an edge-preserving image regularizer to reduce image noise. The combined algorithms have been implemented on a GPU. CBCT projections from clinically operating TrueBeam systems have been used to compare image quality between the conventional and improved reconstruction methods. Planning CT images of the same patients have also been compared. Results: The advanced scatter correction removes shading and inhomogeneity artifacts, reducing the scatter artifact from 99.5 HU to 13.7 HU in a typical pelvis case. Iterative reconstruction provides further benefit by reducing image noise and eliminating streak artifacts, thereby improving soft-tissue visualization. In a clinical head and pelvis CBCT, the noise was reduced by 43% and 48%, respectively, with no change in spatial resolution (assessed visually). Additional benefits include reduction of cone-beam artifacts and reduction of metal artifacts due to intrinsic downweighting of corrupted rays. Conclusion: The combination of an advanced scatter correction with iterative reconstruction substantially improves CBCT image quality. It is anticipated that clinically acceptable reconstruction times will result from a multi-GPU implementation (the algorithms are under active development and not yet commercially available). All authors are employees of and (may) own stock of Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating and applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at positions closer to attenuating hardware structures of the RF coil. The position accuracy of the RF coil on the patient table when using the positioning frame was determined well below 1 mm for all three spatial dimensions. This ensures perfect position match between the RF coil and its three-dimensional attenuation template during the PET data reconstruction process. When applying the CT-based AC of the RF coil, the global attenuation bias was mostly compensated to ±0.5% across the entire breast imaging volume. The patient study revealed high quality MR, PET, and combined PET/MR imaging of breast cancer. Quantitative activity measurements in all 11 breast cancer lesions of the ten patients resulted in increased mean difference values of SUV{sub max} 11.8% (minimum 3.2%; maximum 23.2%) between nonAC images and images when AC of the RF breast coil was applied. This supports the quantitative results of the phantom study as well as successful attenuation correction of the RF coil. Conclusions: A 16-channel breast RF coil was designed for optimized MR imaging performance and PET transparency and was successfully integrated with its dedicated attenuation correction template into a whole-body PET/MR system. Systematic PET/MR imaging evaluation with phantoms and an initial study on patients with breast cancer provided excellent MR and PET image quality and accurate PET quantification.

60 APPLIED LIFE SCIENCES↗

Regional Multistation Discriminants: Magnitude, Distance and Amplitude Corrections and Sources of Error

Magnitude, distance and amplitude corrections (MDAC) made to observed regional amplitudes are necessary so that what remains in the corrected amplitude is mostly information about the seismic source-type. Corrected amplitudes can be used in ratios to discriminate between earthquakes and explosions. However, there remain source effects such as those due to depth, focal mechanism, local material property and apparent stress variability that cannot easily be determined and applied as amplitude corrections. We develop a mathematical model to capture such effects as random (unknown) giving an error partition of two sources: model inadequacy and station noise. This mathematical model is the basis for a general multi-station regional discriminant formulation. The standard error of the discriminant includes the variances of model inadequacy and station noise in its formulation. The developed methods are demonstrated for a suite of Nevada Test Site (NTS) events observed at regional stations. Importantly, the proposed formulation includes all corrected amplitude information through the construction of multi-station discriminants. In contrast, previous studies have only computed discriminants from single stations having both P and S amplitudes. The proposed multi-station approach has similarities to the well established mb versus Ms discriminant.

58 GEOSCIENCES↗

Achieving algorithmic resilience for temporal integration through spectral deferred corrections

Spectral deferred corrections (SDC) is an iterative approach for constructing higher-order-accurate numerical approximations of ordinary differential equations. SDC starts with an initial approximation of the solution defined at a set of Gaussian or spectral collocation nodes over a time interval and uses an iterative application of lower-order time discretizations applied to a correction equation to improve the solution at these nodes. Each deferred correction sweep increases the formal order of accuracy of the method up to the limit inherent in the accuracy defined by the collocation points. In this paper, we demonstrate that SDC is well suited to recovering from soft (transient) hardware faults in the data. A strategy where extra correction iterations are used to recover from soft errors and provide algorithmic resilience is proposed. Specifically, in this approach the iteration is continued until the residual (a measure of the error in the approximation) is small relative to the residual of the first correction iteration and changes slowly between successive iterations. Here, we demonstrate the effectiveness of this strategy for both canonical test problems and a comprehensive situation involving a mature scientific application code that solves the reacting Navier-Stokes equations for combustion research.

97 MATHEMATICS AND COMPUTING↗

Optics measurement and correction during beam acceleration in the Relativistic Heavy Ion Collider

To minimize operational complexities, setup of collisions in high energy circular colliders typically involves acceleration with near constant β-functions followed by application of strong focusing quadrupoles at the interaction points (IPs) for the final beta-squeeze. At the Relativistic Heavy Ion Collider (RHIC) beam acceleration and optics squeeze are performed simultaneously. In the past, beam optics correction at RHIC has taken place at injection and at final energy with some interpolation of corrections into the acceleration cycle. Recent measurements of the beam optics during acceleration and squeeze have evidenced significant beta-beats which if corrected could minimize undesirable emittance dilutions and maximize the spin polarization of polarized proton beams by avoidance of higher-order multipole fields sampled by particles within the bunch. In this report the methodology now operational at RHIC for beam optics corrections during acceleration with simultaneous beta-squeeze will be presented together with measurements which conclusively demonstrate the superior beam control. As a valuable by-product, the corrections have minimized the beta-beat at the profile monitors so reducing the dominant error in and providing more precise measurements of the evolution of the beam emittances during acceleration.

43 PARTICLE ACCELERATORS↗

Development and Implementation of Fault-Correction Algorithms in Fault Detection and Diagnostics Tools

A fault detection and diagnostics (FDD) tool is a type of energy management and information system that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Building operators on the leading edge of technology adoption use FDD tools to enable median whole-building portfolio savings of 8%. Although FDD tools can inform operators of operational faults, currently an action is always required to correct the faults to generate energy savings. A subset of faults, however, such as biased sensors, can be addressed automatically, eliminating the need for staff intervention. Automating this fault “correction” can significantly increase the savings generated by FDD tools and reduce the reliance on human intervention. Doing so is expected to advance the usability and technical and economic performance of FDD technologies. This paper presents the development of nine innovative fault auto-correction algorithms for Heating, Ventilation, and Air Conditioning pi(HVAC) systems. When the auto-correction routine is triggered, it overwrites control setpoints or other variables to implement the intended changes. It also discusses the implementation of the auto-correction algorithms in commercial FDD software products, the integration of these strategies with building automation systems and their preliminary testing.

field testing↗

Continental-scale Validation of MODIS-based and LEDAPS Landsat ETM+ Atmospheric Correction Methods

The potential of Landsat data processing to provide systematic continental scale products has been demonstrated by several projects including the NASA Web-enabled Landsat Data (WELD) project. The recent free availability of Landsat data increases the need for robust and efficient atmospheric correction algorithms applicable to large volume Landsat data sets. This paper compares the accuracy of two Landsat atmospheric correction methods: a MODIS-based method and the Landsat Ecosystem Disturbance Adaptive Processing System (LEDAPS) method. Both methods are based on the 6SV radiative transfer code but have different atmospheric characterization approaches. The MODIS-based method uses the MODIS Terra derived dynamic aerosol type, aerosol optical thickness, and water vapor to atmospherically correct ETM+ acquisitions in each coincident orbit. The LEDAPS method uses aerosol characterizations derived independently from each Landsat acquisition and assumes a fixed continental aerosol type and uses ancillary water vapor. Validation results are presented comparing ETM+ atmospherically corrected data generated using these two methods with AERONET corrected ETM+ data for 95 10 km×10 km 30 m subsets, a total of nearly 8 million 30 m pixels, located across the conterminous United States. The results indicate that the MODIS-based method has better accuracy than the LEDAPS method for the ETM+ red and longer wavelength bands.

Landsat↗

Statistical Downscaling and Bias Correction of Climate Model Outputs for Climate Change Impact Assessment in the U.S. Northeast

Statistical downscaling can be used to efficiently downscale a large number of General Circulation Model (GCM) outputs to a fine temporal and spatial scale. To facilitate regional impact assessments, this study statistically downscales (to 1∕8deg spatial resolution) and corrects the bias of daily maximum and minimum temperature and daily precipitation data from six GCMs and four Regional Climate Models (RCMs) for the northeast United States (US) using the Statistical Downscaling and Bias Correction (SDBC) approach. Based on these downscaled data from multiple models, five extreme indices were analyzed for the future climate to quantify future changes of climate extremes. For a subset of models and indices, results based on raw and bias corrected model outputs for the present-day climate were compared with observations, which demonstrated that bias correction is important not only for GCM outputs, but also for RCM outputs. For future climate, bias correction led to a higher level of agreements among the models in predicting the magnitude and capturing the spatial pattern of the extreme climate indices. We found that the incorporation of dynamical downscaling as an intermediate step does not lead to considerable differences in the results of statistical downscaling for the study domain.

extreme climate index↗

An Accurate Method for Correcting Spectral Convolution Errors in Intercalibration of Broadband and Hyperspectral Sensors

The intercalibration between a broadband and a hyperspectral satellite Earth observation system requires the convolution of the hyperspectral data with the spectral response functions (SRFs) of the corresponding broadband channels. There are two potential issues associated with the convolution procedure. First, the finite resolution of a hyperspectral spectrum, that is, the deviation from the highly accurate line-by-line monochromatic radiances, will contribute to convolution errors. The magnitude of the errors depends on the spectral resolution and the SRF shape of the hyperspectral instrument. This type of the convolution error has not been well recognized, and there is a lack of corresponding discussion in most published papers. Although it is small as compared with the instrument accuracy of existing hyperspectral sounders, the error is deemed to be signicant when it is compared with the stringent calibration requirement imposed by future climate missions like the Climate Absolute Radiance and Refractivity Observatory (CLARREO). Second, some broadband channels are insufficiently covered by the hyperspectral data, causing spectral gaps that lead to convolution errors. Although several methods have been developed to fill the spectral gaps and hence compensate for the second type of convolution error, the correction accuracy may still need improvement especially when a large spectral gap needs to be lled. This paper presents a methodology to accurately quantify and compensate for both types of convolution errors. This methodology utilizes the available hyperspectral information to correct the scene-dependent convolution errors due to either the limited spectral resolution or spectral gaps. We use simulations to characterize the intercalibration errors between the Moderate resolution Imaging Spectroradiometer (MODIS) and current operational infrared sounders. We demonstrate that convolution errors can be effectively removed to meet the highly accurate intersatellite calibration requirement proposed by the Climate Absolute Radiance and Refractivity Observatory. Our methodology is also validated using real satellite data for the intercalibration between Aqua MODIS and Aqua Atmospheric Infrared Sounders (AIRS). Our study demonstrates that the accurate characterization and correction for the convolution errors greatly reduces the scene-dependent and spectrally dependent errors, being critical to the consistency check between Infrared Atmospheric Sounding Interferometer (IASI) and AIRS using the double-difference method. The convolution correction also facilitates the evaluation for other intercalibration errors (e.g., the drift of MODIS SRFs). Our derived SRF shift values from MODIS-AIRS (after convolution error corrections) and from MODIS-IASI intercalibration are consistent with each other. We further extend the methodology to study the calibration of a broadband channel which is either completely or largely uncovered bya hyperspectral measurement.The large spectral gap-filling methodology is validated by demonstrating the accurate prediction of the MODIS radiance of band 29 using the Cross-track Infrared Sounder spectra, with the real IASI spectral data being used as the reference.

Correction Method↗

A Robust In-Situ Warp-Correction Algorithm For VISAR Streak Camera Data at the National Ignition Facility

The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory is a 192-beam pulsed laser system for high-energy-density physics experiments. Sophisticated diagnostics have been designed around key performance metrics to achieve ignition. The Velocity Interferometer System for Any Reflector (VISAR) is the primary diagnostic for measuring the timing of shocks induced into an ignition capsule. The VISAR system utilizes three streak cameras; these streak cameras are inherently nonlinear and require warp corrections to remove these nonlinear effects. A detailed calibration procedure has been developed with National Security Technologies (NSTec) and applied to the camera correction analysis in production. However, the camera nonlinearities drift over time, affecting the performance of this method. An in-situ fiber array is used to inject a comb of pulses to generate a calibration correction in order to meet the timing accuracy requirements of VISAR. We develop a robust algorithm for the analysis of the comb calibration images to generate the warp correction that is then applied to the data images. Our algorithm utilizes the method of thin-plate splines (TPS) to model the complex nonlinear distortions in the streak camera data. In this paper, we focus on the theory and implementation of the TPS warp-correction algorithm for the use in a production environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optics measurement and correction during acceleration with beta-squeeze in RHIC

In the past, beam optics correction at RHIC has only taken place at injection and at final energy, with interpolation of corrections partially into the acceleration cycle. Recent measurements of the beam optics during acceleration and squeeze have evidenced significant beta-beats that, if corrected, could minimize undesirable emittance dilutions and maximize the spin polarization of polarized proton beams by avoiding the high-order multipole fields sampled by particles within the bunch. We recently demonstrated successful beam optics corrections during acceleration at RHIC. We verified conclusively the superior control of the beam realized via these corrections

43 PARTICLE ACCELERATORS↗

Fast Correction of Errors in the DFT‐Calculated Energies of Gaseous Nitrogen‐Containing Species

Abstract Modeling adsorption phenomena on surfaces by DFT calculations often involves substantial errors, resulting in inaccurate predictions of catalytic activities. Such errors partly stem from the inaccurate description of the energetics of free molecules. Herein, we use a semiempirical group‐additivity method to correct the DFT‐calculated heats of formation of 106 carbon‐ and nitrogen‐containing gaseous compounds belonging to 15 different chemical families. PBE, PW91, RPBE and BEEF‐vdW initially yield mean absolute errors (MAEs) with respect to experiments in the range of 0.32–0.75 eV. After correcting the systematic errors, the overall MAEs decrease to ∼0.05 eV. Additionally, upon applying the corrections to three types of reaction enthalpies, the resulting MAEs are below 0.10 eV. These functional‐group corrections can be used in (electro)catalysis to correct the gas‐phase references necessary to evaluate equilibrium potentials and adsorption energies, predict error cancellation, and assess conflicting experimental data.

Urrego‐Ortiz, Ricardo↗

Leading order corrections to the quantum extremal surface prescription

We show that a naïve application of the quantum extremal surface (QES) prescription can lead to paradoxical results and must be corrected at leading order. The corrections arise when there is a second QES (with strictly larger generalized entropy at leading order than the minimal QES), together with a large amount of highly incompressible bulk entropy between the two surfaces. We trace the source of the corrections to a failure of the assumptions used in the replica trick derivation of the QES prescription, and show that a more careful derivation correctly computes the corrections. Using tools from one-shot quantum Shannon theory (smooth min- and max-entropies), we generalize these results to a set of refined conditions that determine whether the QES prescription holds. We find similar refinements to the conditions needed for entanglement wedge reconstruction (EWR), and show how EWR can be reinterpreted as the task of one-shot quantum state merging (using zero-bits rather than classical bits), a task gravity is able to achieve optimally efficiently.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Threshold corrections to the bottom quark mass revisited

Threshold corrections to the bottom quark mass are often estimated under the approximation that tan β enhanced contributions are the most dominant. In this work we revisit this common approximation made to the estimation of the supersymmetric thresh-old corrections to the bottom quark mass. We calculate the full one-loop supersymmetric corrections to the bottom quark mass and survey a large part of the phenomenological MSSM parameter space to study the validity of considering only the tan β enhanced corrections. Our analysis demonstrates that this approximation underestimates the size of the threshold corrections by ~12.5% for most of the considered parameter space. We discuss the consequences for fitting the bottom quark mass and for the effective couplings to Higgses. Here, we find that it is important to consider the additional contributions when fitting the bottom quark mass but the modifications to the effective Higgs couplings are typically O(few)% for the majority of the parameter space considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Next-to-next-to-leading power corrections to unpolarized Semi-Inclusive Deep Inelastic Scattering

Semi-Inclusive Deep Inelastic Scattering (SIDIS) is a key tool for exploring the three-dimensional structure of the nucleon through Transverse Momentum Dependent parton distributions and fragmentation functions. While leading-power contributions to the SIDIS cross-section are well established, next-to-leading power (NLP) corrections of order 1/Q and next-to-next-to-leading power (NNLP) corrections of order 1/Q 2 to the hadronic tensor have only recently begun to be systematically investigated. These corrections are essential for reliable phenomenology and interpretation of modern high-precision data. In recent papers by one of the authors, NNLP corrections to the Drell-Yan process were derived using the rapidity factorization formalism. In the present work, we extend this approach to SIDIS and obtain analytic expressions for the unpolarized structure functions. We derive NNLP corrections that include convolutions of unpolarized distributions, f 1 , with unpolarized fragmentation functions, D 1 , and Boer-Mulders functions, ${h}_1^{\perp }$, with Collins fragmentation functions, ${H}_1^{\perp }$. We compare our results with previous formulations, provide numerical studies, confront our predictions with HERMES and COMPASS measurements, and present predictions for future experiments at Jefferson Lab and the Electron-Ion Collider.

deep inelastic scattering↗

Non-topological logarithmic corrections in minimal gauged supergravity

We compute the logarithmic correction to the entropy of asymptotically AdS4 black holes in minimal N = 2 gauged supergravity. We show that for extremal black holes the logarithmic correction computed in the near horizon geometry agrees with the result in the full geometry up to zero mode contributions, thus clarifying where the quantum degrees of freedom lie in AdS spacetimes. In contrast to flat space, we observe that the logarithmic correction for supersymmetric black holes can be non-topological in AdS as it is controlled by additional four-derivative terms other than the Euler density. The available microscopic data and results in 11d supergravity indicate that the full logarithmic correction is topological, which suggests that the topological nature of logarithmic corrections could serve as a diagnosis of whether a low-energy gravity theory admits an ultraviolet completion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Avoiding full corrections in dynamic SPECT images impacts the performance of SPECT myocardial blood flow quantitation

Introduction: This study investigated the performance of SPECT myocardial blood flow (MBF) quantitation lacking full physical corrections (All Corr) in dynamic SPECT (DySPECT) images. Methods: Eleven healthy normal volunteers (HVT) and twenty-four patients with angiography-documented CAD were assessed. All Corr in {sup 99m}Tc-sestamibi DySPECT encompassed noise reduction (NR), resolution recovery (RR), and corrections for scatter (SC) and attenuation (AC), otherwise no correction (NC) or only partial corrections. The performance was evaluated by quality index (R{sup 2}) and blood-pool spillover index (FBV) in kinetic modeling, and by rest flow (RMBF) and stress flow (SMBF) compared with those of All Corr. Results: In HVT group, NC diminished 2-fold flow uniformity with the most degraded quality (15%-18% reduced R{sup 2}) and elevated spillover effect (45%-50% increased FBV). Consistently higher RMBF and SMBF were discovered in both groups (HVT 1.54/2.31 higher; CAD 1.60/1.72; all P < .0001). Bland-Altman analysis revealed positive flow bias (HVT 0.9-2.6 mL/min/g; CAD 0.7-1.3) with wide ranges of 95% CI of agreement (HVT NC −1.9-7.1; NR −0.4-4.4; NR + SC −1.1-4.3; NR + SC + RR −0.7-2.5) (CAD NC −1.2-3.8; NR −1.0-2.8; NR + SC −1.0-2.5; NR + SC + RR −1.1-2.6). Conclusions: Uncorrected physical interference in DySPECT images can extensively impact the performance of MBF quantitation. Full physical corrections should be considered to warrant this tool for clinical utilization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗