Guideline for Performing Systematic Approach to Evaluate and Qualify Legacy Documents that Support Advanced Reactor Technology Activity

The establishment of a systematic process for the evaluation of historic technology information for use in advanced reactor licensing is described. Efforts are underway to recover and preserve Experimental Breeder Reactor II and Fast Flux Test Facility historical data. These efforts have generally emphasized preserving information from data-acquisition systems and hard-copy reports and entering it into modern electronic formats suitable for data retrieval and examination. The guidance contained in this document has been developed to facilitate consistent and systematic evaluation processes relating to quality attributes of historic technical information (with focus on sodium-cooled fast reactor (SFR) technology) that will be used to eventually support licensing of advanced reactor designs. The historical information may include, but is not limited to, design documents for SFRs, research-and-development (R&D) data and associated documents, test plans and associated protocols, operations and test data, international research data, technical reports, and information associated with past U.S. Nuclear Regulatory Commission (NRC) reviews of SFR designs. The evaluation process is prescribed in terms of SFR technology, but the process can be used to evaluate historical information for any type of advanced reactor technology. An appendix provides a discussion of typical issues that should be considered when evaluating and qualifying historical information for advanced reactor technology fuel and source terms, based on current light water reactor (LWR) requirements and recent experience gained from Next Generation Nuclear Plant (NGNP).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Initial operation of a solar heating and cooling system in a full-scale solar building test facility

The Solar Building Test Facility (SBTF) located at Hampton, Virginia became operational in early summer of 1976. This facility is a joint effort by NASA-Lewis and NASA-Langley to advance the technology for heating and cooling of office buildings with solar energy. Its purposes are to (1) test system components which include high-performing collectors, (2) test performance of complete solar heating and cooling system, (3) investigate component interactions and (4) investigate durability, maintenance and reliability of components. The SBTF consists of a 50,000 square foot office building modified to accept solar heated water for operation of an absorption air conditioner and for the baseboard heating system. A 12,666 square foot solar collector field with a 30,000 gallon storage tank provides the solar heated water. A description of the system and the collectors selected is given here, along with the objectives, test approach, expected system performance and some preliminary results.

Knoll, R. H.↗

Injection locking of a high power ultraviolet laser diode for laser cooling of ytterbium atoms

We developed a high-power laser system at a wavelength of 399 nm for laser cooling of ytterbium atoms with ultraviolet laser diodes. The system is composed of an external cavity laser diode providing frequency stabilized output at a power of 40 mW and another laser diode for amplifying the laser power up to 220 mW by injection locking. The systematic method for optimization of our injection locking can also be applied to high power light sources at any other wavelengths. Our system does not depend on complex nonlinear frequency-doubling and can be made compact, which will be useful for providing light sources for laser cooling experiments including transportable optical lattice clocks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LLE Review 119 (April-June 2009)

This issue has the following articles: (1) Shock-Ignition Experiments on OMEGA at NIF-Relevant Intensities; (2) Laser-Driven Magnetic-Flux Compression in High-Energy-Density Plasmas; (3) Lorentz Mapping of Magnetic Fields in Hot, Dense Plasmas; (4) Characterization and Optimization of Yb-Doped Photonic-Crystal Fiber Rod Amplifiers Using Spatially Resolved Spectral Interferometry; (5) Optical Differentiation and Multimillijoule {approx}150-ps Pulse Generation in a Regenerative Amplifier with a Temperature-Tuned Intracavity Volume Bragg Grating; (6) Slow Crack Growth During Radiatiave Cooling of LHG8 and BK7 Plates; and (7) Finite Element Simulation of Metal-Semiconductor-Metal Photoconductor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combined Heat and Power Technology Fact Sheet Series: Thermal Energy Storage

This fact sheet provides an overview of thermal energy storage (TES) technologies, which heat or cool a storage medium and, when needed, deliver the stored thermal energy to meet heating or cooling needs. TES systems are used in commercial buildings, industrial processes, and district energy installations to deliver stored thermal energy during peak demand periods, thereby reducing peak energy use. TES systems are often integrated with electric or absorption chillers to reduce peak electricity costs and, in the case of new construction, to reduce capital costs by optimizing chiller size. TES technologies can support sites that have either renewable or fossil power generation, including combined heat and power (CHP) installations. With CHP, TES can help optimize equipment size by reducing the required peak CHP thermal capacity and increasing annual CHP usage. TES can also provide turbine inlet cooling for gas turbines used in CHP applications, which increases power production in hot ambient conditions.

Combined Heat and Power, CHP, Thermal Energy, Tech↗

Periodic thermomagnetic structures in solar plasma

Stationary solutions in the form of small-scale periodic cells in a plane perpendicular to the magnetic field are obtained in the framework of two-fluid magnetohydrodynamics. The solutions are established as a result of the development of thermal instability and represent a superposition of standing temperature waves. In solving the problem, an expression is used for a generalized heat source (including heating and radiative cooling) that forms a temperature transition region between the chromosphere and corona.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of the 1S–2P Lyman-α transition in antihydrogen

In 1906, Theodore Lyman discovered his eponymous series of transitions in the extreme-ultraviolet region of the atomic hydrogen spectrum1,2. The patterns in the hydrogen spectrum helped to establish the emerging theory of quantum mechanics, which we now know governs the world at the atomic scale. Since then, studies involving the Lyman-α line—the 1S–2P transition at a wavelength of 121.6 nanometres—have played an important part in physics and astronomy, as one of the most fundamental atomic transitions in the Universe. For example, this transition has long been used by astronomers studying the intergalactic medium and testing cosmological models via the so-called ‘Lyman-α forest’3 of absorption lines at different redshifts. Here we report the observation of the Lyman-α transition in the antihydrogen atom, the antimatter counterpart of hydrogen. Using narrow-line-width, nanosecond-pulsed laser radiation, the 1S–2P transition was excited in magnetically trapped antihydrogen. The transition frequency at a field of 1.033 tesla was determined to be 2,466,051.7 ± 0.12 gigahertz (1σ uncertainty) and agrees with the prediction for hydrogen to a precision of 5 × 10-8. Comparisons of the properties of antihydrogen with those of its well-studied matter equivalent allow precision tests of fundamental symmetries between matter and antimatter. Alongside the ground-state hyperfine4,5 and 1S–2S transitions6,7 recently observed in antihydrogen, the Lyman-α transition will permit laser cooling of antihydrogen8,9, thus providing a cold and dense sample of anti-atoms for precision spectroscopy and gravity measurements10. In addition to the observation of this fundamental transition, this work represents both a decisive technological step towards laser cooling of antihydrogen, and the extension of antimatter spectroscopy to quantum states possessing orbital angular momentum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced Airfoil Cooling Schemes to Increase Efficiency in Gas Turbines for Combined Heat and Power Applications

This report describes a three-year interdisciplinary effort funded by the U.S. Department of Energy’s (DOE) Energy Efficiency and Renewable Energy/Advanced Manufacturing Office (EERE/AMO) to promote market penetration of combined heat and power (CHP) technologies. Prior studies have shown the technical potential for CHP in the United States is much larger than the current deployment of CHP systems. A large portion of the technical potential CHP market aligns with small (<20 MWe) gas turbines. CHP systems are an attractive alternative to reduce greenhouse gas (GHG) emissions. For example, CHP systems can reduce GHG emissions by 30–40% relative to a conventional boiler and power configuration. These GHG emission reductions are “avoided emissions” which means no CO 2 separation or sequestration is required. This report describes an effort to use additive manufacturing (AM) technologies and advanced airfoil cooling designs to increase the turbine inlet temperature by 100 °C for small gas turbines typically used in CHP systems. At the beginning of this effort, baseline performance data for small gas turbines was not available, and the potential benefits of cooling system improvements were not quantified in the available literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control

District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. By exploiting the available thermal energy storage capacity, the MPC controller is capable of shifting up to 14% of the electricity consumption of the ETS from on-peak to off-peak hours. Therefore, the advanced control implemented in 5GDHC networks promotes coupling between the thermal and the electric sector, producing flexibility on the electric grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fabrication of liquid-rocket thrust chambers by electroforming

Electroforming has proven to be an excellent fabrication method for building liquid rocket regeneratively cooled thrust chambers. NASA sponsored technology programs have investigated both common and advanced methods. Using common procedures, several cooled spool pieces and thrust chambers have been made and successfully tested. The designs were made possible through the versatility of the electroforming procedure, which is not limited to simple geometric shapes. An advanced method of electroforming was used to produce a wire-wrapped, composite, pressure-loaded electroformed structure, which greatly increased the strength of the structure while still retaining the advantages of electroforming.

Duscha, R. A.↗

Development of a Data Platform for High-Temperature Gas-cooled Reactor (HTGR) Nuclear Energy University Program (NEUP) Thermal-Fluid Experiments

Since the U.S. Department of Energy (DOE)’s Office of Nuclear Energy (NE) initiated the Nuclear Energy University Program (NEUP) in 2009, a total of 30 NEUP projects focused on High-Temperature Gas-cooled Reactor (HTGR) thermal-fluid experiments were funded up to fiscal year (FY) 2021. This represents a total DOE investment of approximately $23M over the 12-year period, covering thermal fluid phenomena important to both pebble bed and prismatic HTGR designs. The NEUP projects have produced a large amount of high-quality experimental and computational data that were published in final project reports, journal articles, dissertations, and conference proceedings, but in most cases the actual data sets and supporting information such as facility and instrumentation descriptions were not publicly disseminated to the HTGR community. To the authors’ best knowledge, a data platform that organizes and summarizes these NEUP-funded projects for HTGR research does not currently exist. To improve access to this HTGR validation data and optimize the return on the significant investment made by DOE, the Advanced Reactor Technologies (ART) Gas-Cooled Reactor (GCR) program started a survey of completed and ongoing HTGR NEUP projects with the aim of developing a public-access data platform that can be used to retrieve computational fluid dynamics (CFD) and system code validation data and guide future NEUP investments. This paper summarizes the status of the current ART-GCR database, provides an overview of the NEUP-funded HTGR-related research projects from FY2009 to FY2021 and identify validation knowledge gaps still existing in HTGR thermal-fluid research.

42 ENGINEERING↗

Fighting Fire with Fire: Superlattice Cooling of Silicon Hotspots to Reduce Global Cooling Requirements

The running costs of data centers are dominated by the need to dissipate heat generated by thousands of server machines. Higher temperatures are undesirable as they lead to premature silicon wear-out; in fact, mean time to failure has been shown to decrease exponentially with temperature (Black's law). Although other server components also generate heat, microprocessors still dominate in most server configurations and are also the most vulnerable to wearout as the feature sizes shrink. Even as processor complexity and technology scaling have increased the average energy density inside a processor to maximally tolerable levels, modern microprocessors make extensive use of hardware structures such as the load-store queue and other CAM-based units, and the peak temperatures on chip can be much worse than even the average temperature of the chip. In recent studies, it has been shown that hot-spots inside a processor can generate {approx} 800W/cm{sup 2} heat flux whereas the average heat flux is only 10-50W/cm{sup 2}, and due to this disparity in heat generation, the temperature in hot spots may be up to 30 C more than average chip temperature. The key problem processor hot-spots create is that in order to prevent some critical hardware structures from wearing out faster, the air conditioners in a data center have to be provisioned for worst case requirements. Worse yet, air conditioner efficiencies decrease exponentially as the desired ambient temperature decreases relative to the air outside. As a result, the global cooling costs in data centers, which nearly equals the IT equipment power consumption, are directly correlated with the maximum hot spot temperatures of processors, and there is a distinct requirement for a cooling technique to mitigate hot-spots selectively so that the global air conditioners can operate at higher, more efficient, temperatures. We observe that localized cooling via superlattice microrefrigeration presents exactly this opportunity whereby hot-spots can be cooled selectively and allow global coolers to operate at much more efficient temperatures. Recent advances in processor cooling technologies have demonstrated that thermoelectric coolers (TEC), which use a Peltier effect to form heat pumps, can be used to reduce the temperature of hot spots. By applying a thermoelectric cooler between the heat spreader and the processor die and applying current selectively at the hot spots, heat from the hot-spots can be spread much more efficiently. The ability to implement such thermoelectric coolers on a real silicon device has been demonstrated recently, albeit for small prototype chips. The key question then, that needs to be answered before such thermoelectric coolers can be integrated in commodity server processors, is 'What is the potential for superlattice microrefrigeration to reduce global cooling costs in data centers?'. In order to answer this question, we present a comprehensive analysis of the impact of thermoelectric coolers on global cooling costs. Our thermal analysis covers all aspects of cooling a server in a data center, and integrates on-chip dynamic and leakage power sources with a detailed heat diffusion model of a processor (that models the silicon to the thermoelectric cooler to the heat spreader and the heat sink) and finally the computer room air conditioner (CRAC) efficiency, as shown in Figure 1. In Section II, we present the components of the system model.

99 GENERAL AND MISCELLANEOUS↗

Cryogenic System for the Origins Space Telescope: Cooling a Large Space Telescope to 4K with Today's Technology

The Origins Space Telescope (OST) concept is one of four NASA Science Mission Directorate, Astrophysics Division, observatory concepts being studied for launch in the mid 2030's. OST's wavelength coverage will be from the midinfrared to the sub-millimeter, 6-600 microns. To enable observations at the zodiacal background limit the telescope must be cooled to about 4 K. Combined with the telescope size (currently the primary is 9 m in diameter) this appears to be a daunting task. However, simple calculations and thermal modeling have shown the cooling power required is met with several currently developed cryocoolers. Further, the telescope thermal architecture is greatly simplified, allowing simpler models, more thermal margin, and higher confidence in the final performance values than previous cold observatories. We will describe design principles to simplify modeling and verification. We will argue that the OST architecture and design principles lower its integration and test time and reduce its ultimate cost.

telescopes↗

A continuous dry 300 mK cooler for THz sensing applications

We describe and demonstrate the automated operation of a novel cryostat design that is capable of maintaining an unloaded base temperature of less than 300 mK continuously, without the need to recycle the gases within the final cold head, as is the case for conventional single shot sorption pumped {sup 3}He cooling systems. This closed dry system uses only 5 l of {sup 3}He gas, making this an economical alternative to traditional systems where a long hold time is required. During testing, a temperature of 365 mK was maintained with a constant 20 μW load, simulating the cooling requirement of a far infrared camera.

42 ENGINEERING↗

Geothermal Academy: Focus Center for Data Collection, Analysis, and Dissemination

Geothermal Academy: A Pathway for Confirmation of Ground-Source Heat Pumps in the United States. In 2008, Oak Ridge National Laboratory issued a report on geothermal heats pumps (GHPs) focused on the market status, barriers to adoption, and actions to overcome these barriers (Hughes 2008). Of the barriers raised in this report, of the most pressing is the lack of performance and energy usage data for GHPs. Further, an associated barrier is a lack of a fair comparison of the energy usage of conventional heating and cooling systems for the same building. Because of these barriers, we are not able to say how much energy is used by well-designed GHP systems on a long-term basis, nor are we able to say how better their energy usage is compared to conventional systems. The need for a fair comparison with conventional systems is particularly relevant as modern versions of conventional air conditioners, gas furnaces, and boilers have also incorporated energy saving technologies. As a first step to address this barrier, the Geothermal Academy has developed a framework for data collection. This framework has already been applied to several geothermal installations in Colorado (Nakagawa etal. 2010). The framework classifies data into different categories based on the relevance of the dat to understanding the energy consumption of a GHP system. The categories are: direct energy consumption data, heat exchange performance data, and GHP design parameter data. The main recommendation of this project is to include a minimal data collection system on each heat pump installed in the U.S., capable of measuring the electrical energy consumed, the entering/exiting fluid temperatures, and circulation rates. This is a viable and cost effective solution which will provide performance data, as data collection systems are only a fraction of the cost of a GHP unit and modern GHP units already incorporate sensors to monitor energy usage and the entering and exiting fluid temperatures. Specifically, these sensors are used to control the GHP unit to provide the heat exchange required to provide a desired temperature within a building. Accordingly, it is straightforward for this operational data to be collected to start building a database of GHP performance such that can provide statistically relevant comparison with other heating and cooling systems. In addition to collecting the data, such a system could be easily implemented with a wireless transmitter so that data could be sent to a home PC where it could be transmitted to a central database. Display of the data on a user's PC would provide feedback on the performance of their system which could perhaps refine their use of the system to reach their personal energy goals. Although a system such as that described above has yet to be incorporated directly into commercial GHP systems, it is straightforward and inexpensive to outfit a GHP with a data acquisition system and supplemental sensors. A secondary recommendation is to consider funding a pilot effort that will collect the energy and performance time series data from a representative sample of installations. A preliminary pilot effort was undertaken by the Geothermal Academy at a middle school in Ft. Collins, Colorado, which demonstrated the feasibility and ease of such an effort. A full-scale pilot effort would be most suited to evaluate the performance of GHP installations in different climate settings, preferably focusing on residential, commercial, and public buildings. If a full-scale pilot effort were to be undertaken, it is recommended to also identify large buildings which may incorporate a back-up conventional heating and cooling system in order to provide statistically relevant comparison data to assess the improvement in GHP energy usage over other heating and cooling technologies. Such a data collection system would provide several benefits to the different sectors of society (consumers, installers, policy makers, researchers, utility companies, government regulators) which are concerned with GHP technology and implementation.

15 GEOTHERMAL ENERGY↗

Enabling Intensity and Energy Frontier Science with a Muon Accelerator Facility in the U.S.: A White Paper Submitted to the 2013 U.S. Community Summer Study of the Division of Particles and Fields of the American Physical Society

A staged approach towards muon based facilities for Intensity and Energy Frontier science, building upon existing and proposed facilities at Fermilab, is presented. At each stage, a facility exploring new physics also provides an R&D platform to validate the technology needed for subsequent stages. The envisioned program begins with nuSTORM, a sensitive sterile neutrino search which also provides precision neutrino cross-section measurements while developing the technology of using and cooling muons. A staged Neutrino Factory based upon Project X, sending beams towards the Sanford Underground Research Facility (SURF), which will house the LBNE detector, could follow for detailed exploration of neutrino properties at the Intensity Frontier, while also establishing the technology of using intense bunched muon beams. The complex could then evolve towards Muon Colliders, starting at 126 GeV with measurements of the Higgs resonance to sub-MeV precision, and continuing to multi-TeV colliders for the exploration of physics beyond the Standard Model at the Energy Frontier. An Appendix addresses specific questions raised by the Lepton Colliders subgroup of the CSS2013 Frontier Capabilities Study Group.

43 PARTICLE ACCELERATORS↗

Cold Stowage Flight Systems

The International Space Station (ISS) provides a test bed for researchers to perform science experiments in a variety of fields, including human research, life sciences, and space medicine. Many of the experiments being conducted today require science samples to be stored and transported in a temperature controlled environment. NASA provides several systems which aide researchers in preserving their science. On orbit systems provided by NASA include the Minus Eighty Laboratory freezer for ISS (MELFI), Microgravity Experiment Research Locker Incubator (MERLIN), and Glacier. These freezers use different technologies to provide rapid cooling and cold stowage at different temperature levels on board ISS. Systems available to researchers during transportation to and from ISS are MERLIN, Glacier, and Coldbag. Coldbag is a passive cold stowage system that uses phase change materials. Details of these current technologies will be provided along with operational experience gained to date. With shuttle retirement looming, NASA has protected the capability to provide a temperature controlled environment during transportation to and from the ISS with the use of Glacier and Coldbags, which are compatible with future commercial vehicles including SpaceX's Dragon Capsule, and Orbital s Cygnus vehicle. This paper will discuss the capability of the current cold stowage hardware and how it may continue to support NASA s mission on ISS and in future exploration missions.

Campana, Sharon↗

Reducing water freshwater consumption at coal-fired power plants : approaches used outside the United States.

Coal-fired power plants consume huge quantities of water, and in some water-stressed areas, power plants compete with other users for limited supplies. Extensive use of coal to generate electricity is projected to continue for many years. Faced with increasing power demands and questionable future supplies, industries and governments are seeking ways to reduce freshwater consumption at coal-fired power plants. As the United States investigates various freshwater savings approaches (e.g., the use of alternative water sources), other countries are also researching and implementing approaches to address similar - and in many cases, more challenging - water supply and demand issues. Information about these non-U.S. approaches can be used to help direct near- and mid-term water-consumption research and development (R&D) activities in the United States. This report summarizes the research, development, and deployment (RD&D) status of several approaches used for reducing freshwater consumption by coal-fired power plants in other countries, many of which could be applied, or applied more aggressively, at coal-fired power plants in the United States. Information contained in this report is derived from literature and Internet searches, in some cases supplemented by communication with the researchers, authors, or equipment providers. Because there are few technical, peer-reviewed articles on this topic, much of the information in this report comes from the trade press and other non-peer-reviewed references. Reducing freshwater consumption at coal-fired power plants can occur directly or indirectly. Direct approaches are aimed specifically at reducing water consumption, and they include dry cooling, dry bottom ash handling, low-water-consuming emissions-control technologies, water metering and monitoring, reclaiming water from in-plant operations (e.g., recovery of cooling tower water for boiler makeup water, reclaiming water from flue gas desulfurization [FGD] systems), and desalination. Some of the direct approaches, such as dry air cooling, desalination, and recovery of cooling tower water for boiler makeup water, are costly and are deployed primarily in countries with severe water shortages, such as China, Australia, and South Africa. Table 1 shows drivers and approaches for reducing freshwater consumption in several countries outside the United States. Indirect approaches reduce water consumption while meeting other objectives, such as improving plant efficiency. Plants with higher efficiencies use less energy to produce electricity, and because the greater the energy production, the greater the cooling water needs, increased efficiency will help reduce water consumption. Approaches for improving efficiency (and for indirectly reducing water consumption) include increasing the operating steam parameters (temperature and pressure); using more efficient coal-fired technologies such as cogeneration, IGCC, and direct firing of gas turbines with coal; replacing or retrofitting existing inefficient plants to make them more efficient; installing high-performance monitoring and process controls; and coal drying. The motivations for increasing power plant efficiency outside the United States (and indirectly reducing water consumption) include the following: (1) countries that agreed to reduce carbon emissions (by ratifying the Kyoto protocol) find that one of the most effective ways to do so is to improve plant efficiency; (2) countries that import fuel (e.g., Japan) need highly efficient plants to compensate for higher coal costs; (3) countries with particularly large and growing energy demands, such as China and India, need large, efficient plants; (4) countries with large supplies of low-rank coals, such as Germany, need efficient processes to use such low-energy coals. Some countries have policies that encourage or mandate reduced water consumption - either directly or indirectly. For example, the European Union encourages increased efficiency through its cogeneration directive, which requires member states to assess their national potential for cogeneration, analyze barriers to achieving the potential, and then establish support schemes to achieve the potential. China's Eleventh Five-Year Plan (2006-2010) has an energy strategy that specifies, among other things, that production should be optimized by promoting the development of large-scale, high-efficiency units, and that air-cooled technologies should be used in areas with water shortages. The United States lacks many of these drivers. There are no government requirements that mandate more efficient plants. The United States has ample supplies of relatively cheap coal, and U.S. water-short areas are not as extensive as in countries such as China, South Africa, and Australia. Often, other countries have deployed water-savings technologies to a greater degree than the United States.

01 COAL, LIGNITE, AND PEAT↗