Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Review of Tools for Modeling Core Radial Expansion in Liquid Metal-Cooled Fast Reactors

Core radial expansion in liquid-metal cooled fast reactor systems is a well-known phenomenon that produces strong reactivity feedback effects. It is crucial from a safety standpoint to design a reactor with the proper core restraint system to guide expansion of the fuel assemblies into a formation that produces negative reactivity feedback in accident conditions. However, the modeling of core radial expansion and its associated reactivity feedback is extremely challenging. Liquid metal-cooled fast reactor designers (both industry and commercial) have pointed to improved modeling of core radial expansion as a key modeling challenge for these types of reactors. The Department of Energy Nuclear Energy Advanced Modeling and Simulation (DOE-NEAMS) program has an important role to play in helping to develop a robust, predictive tool for this phenomenon. A literature review has been performed to identify current simulation capabilities applicable to the prediction of core radial expansion in liquid metal-cooled fast reactors and the resultant reactivity feedback effects. An overview as well as a detailed description of the multi-physics phenomena underlying core radial expansion is given in the first two chapters. The objective of this report is to identify existing software that has been or could be applied to the core radial expansion problem, and then to identify possible paths to develop a robust, coupled Multiphysics tool for advanced analysis, in which all three physics (radiation transport, structural mechanics, thermal fluids) are taken into account considering feedback effects from each physics to the other. Several computer codes and workflows have been developed in the United States and abroad to perform individual aspects of radial expansion calculations or to perform loosely coupled analysis. No code system currently exists which tightly and robustly couples the neutronics, thermal hydraulics, and thermal mechanical physics with enough detail to fully resolve the complex core radial expansion reactivity feedback effects. The future availability of such a code system is of vital importance to fully understanding the reactivity feedback effects that occur due to radial expansion, and consequently to optimizing the design of the core restraint system. A potential code development path forward using MOOSE-based tools is suggested in order to leverage the natural tight coupling and robustness of MOOSE-based applications. Additionally, potential gaps for modeling and common assumptions are listed which require further investigation to ensure accuracy for prediction of deformations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Thermal Reservoir Networks for Modularly Expandable Thermal Microgrids

The Department of Defense (DoD) faces the substantial challenge of cost-effectively retrofitting one to two installations per month, each comprising approximately 1,000 buildings, to improve resilience, reduce energy consumption, and enhance energy supply security. Achieving these objectives requires optimal system selection and effective risk mitigation during system integration. To address this need, we introduce Platform-Based Design (PBD), a structured, hierarchical methodology adapted from other industrial sectors to the domain of energy system retrofits. We demonstrate the effectiveness of PBD through a techno-economic feasibility study comparing geothermal-coupled thermal energy networks (TENs) with conventional energy systems for heating, cooling, and powering 17 buildings at Joint Base Andrews (JBA) in Maryland. Our analysis illustrates that the PBD approach enables rigorous, data-driven, sequential decision making, resulting in a family of Pareto-optimal systems, among which the TEN emerged as the most promising solution. The selected TEN design integrates geothermal borefields, heat recovery heat pumps, photovoltaic (PV) arrays, and battery storage. Compared to the baseline system – gas heating combined with air-source chillers – the proposed TEN reduces annual imported energy by 74% and peak electricity demand by 45%, achieves a levelized cost of energy of $\$0.210$/kWh, and substantially enhances resilience. Life-cycle costs increase by approximately 6%, and initial investment costs are about 2.5 times higher than the baseline. However, if central plant infrastructure, district loops, and utility-scale PV and battery systems are privately funded and operated, the initial investment would fall below the baseline system cost. Critical to achieving these significant performance improvements were detailed nonlinear dynamic simulations coupling geothermal heat transfer, energy system operation, and realistic feedback control logic. These simulations identified essential design modifications and control strategy refinements that substantially reduced energy use, peak demand, and compressor shortcycling, thereby improving durability and reliability—issues that would have been significantly more expensive to resolve during operation. Additionally, the verification step highlighted sensitivities to key design parameters that could reduce initial investment by approximately $\$2$ million and reduce annual life-cycle costs more than $\$300,000$. We recommend adopting the PBD methodology for future feasibility studies and TEN pilot projects to gain valuable operational experience. Furthermore, we recommend that DoD invest in transferring and scaling the PBD methodology to other installations. This entails developing standardized computational frameworks and component libraries as well as training industry in conducting PBD. Such investments would enable rapid, robust, reliable, and cost-effective retrofits, supporting DoD’s ambitious energy system modernization goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptive shape control of wavefront-preserving X-ray mirrors with active cooling and heating

This article describes the development and testing of a novel, water cooled, active optic mirror system (called “REAL: Resistive Element Adjustable Length”) that combines cooling with applied auxiliary heating, tailored to the spatial distribution of the thermal load generated by the incident beam. This technique is theoretically capable of sub-nanometer surface figure error control even at high power density. Tests conducted in an optical metrology laboratory and at synchrotron X-ray beamlines showed the ability to maintain the mirror profile to the level needed for the next generation storage rings and FEL mirrors.

42 ENGINEERING↗

WEST actively cooled load resilient ion cyclotron resonance heating system results

Three identical new WEST ion cyclotron resonance heating (ICRH) antennas have been designed, assembled then commissioned on plasma from 2013 to 2019. The WEST ICRH system is both load-resilient and compatible with long-pulse operations. The three antennas have been successfully operated together on plasma in 2019 and 2020, with up to 5.8 MW of coupled power. In this work, the load resilience capability has been demonstrated and the antenna feedback controls for phase and matching have been developed. The breakdown detection systems have been validated and successfully protected the antennas. The use of ICRH in combination with lower hybrid has triggered the first high confinement mode transitions identified on WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

5G Enabled Energy Innovation: Advanced Wireless Networks for Science (Workshop Report)

Rapidly expanding, new telecommunications infrastructure based on 5G technologies will disrupt and transform how we design, build, operate, and optimize scientific infrastructure and the experiments and services enabled by that infrastructure, from continental-scale sensor networks to centralized scientific user facilities, from intelligent Internet of Things devices to supercomputers. Concurrently, 5G will introduce, or exacerbate, challenges related to protecting infrastructure and associated scientific data as well as to fully leveraging opportunities related to expanded infrastructure scale and complexity. The U.S. Department of Energy (DOE) Office of Science operates scientific infrastructure, supporting some of the nation’s most advanced intellectual discoveries, spanning the country and including 30 world-class user facilities from supercomputers to accelerators. Along with field experiments and remote observatories, every aspect of DOE’s scientific enterprise will be affected by 5G, which amounts to a complete renovation of the underpinnings of the nation’s information infrastructure. In this report we explore the scientific opportunities and new research challenges associated with 5G, ranging from scalability to heterogeneity to cybersecurity. The rapid commercial deployment of 5G opens the opportunity to rethink and reinvent DOE’s scientific infrastructure and experimentation, from intelligent sensor networks at unprecedented scales to a digital continuum of cyberinfrastructure spanning low-power sensors, high-performance computing embedded within and at the edge of the network, and DOE’s large-scale user instrument and computing facilities. New programming paradigms, workflow and data frameworks, and AI-based system design, operation, and autonomous adaptation and optimization will be necessary in order to exploit these new opportunities. Field deployments and centralized scientific instruments can also be revolutionized, moving (without traditional performance penalties) from wired to wireless connectivity for data and control systems, improving flexibility, and opening new sensing modalities, including the use of the 5G electromagnetic spectrum itself as an environmental probe. For DOE science, in contrast to commercial 5G applications and settings, devices will be deployed in extreme environments such as cryogenically cooled instrument control systems and in remote settings with harsh conditions, requiring the design of new materials for RF communication and edge processing to operate in these regimes. Concurrently, 5G infrastructure comprises both hardware and sophisticated software systems - currently closed and proprietary. The cybersecurity challenges to 5G-empowered reinvention mirror the complexity and variety of new 5G features, from virtualization to private network slices to ubiquitous access. Research is also needed in order to accelerate the development of secure and open 5G software infrastructure, reducing reliance on hardware and software produced outside the United States and providing the transparency and rigorous evaluation and testing afforded through open software. Twelve broad research thrusts are laid out in four chapters, with a companion fifth chapter (and three additional research thrusts) underscoring the needs and opportunities for an aggressive testbed program co-designed by networking experts and scientists involved in the 15 research thrusts. The urgency of undertaking this research is fueled by a global, accelerating deployment of new telecommunications infrastructure that is designed for entertainment and commercial applications - barely scratching the surface of what 5G can do to extend U.S. leadership in scientific discovery.

42 ENGINEERING↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WEST actively cooled load resilient ion cyclotron resonance heating system results

Three identical new WEST ion cyclotron resonance heating (ICRH) antennas have been designed, assembled then commissioned on plasma from 2013 to 2019. The WEST ICRH system is both load-resilient and compatible with long-pulse operations. The three antennas have been successfully operated together on plasma in 2019 and 2020, with up to 5.8 MW of coupled power. The load resilience capability has been demonstrated and the antenna feedback controls for phase and matching have been developed. The breakdown detection systems have been validated and successfully protected the antennas. The use of ICRH in combination with lower hybrid has triggered the first high confinement mode transitions identified on WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Digital Twin Framework for Liquid-cooled Supercomputers as Demonstrated at Exascale

We present ExaDigiT, an open-source framework for developing comprehensive digital twins of liquid-cooled supercomputers. It integrates three main modules: (1) a resource allocator and power simulator, (2) a transient thermo-fluidic cooling model, and (3) an augmented reality model of the supercomputer and central energy plant. The framework enables the study of "what-if" scenarios, system optimizations, and virtual prototyping of future systems. Using Frontier as a case study, we demonstrate the framework's capabilities by replaying six months of system telemetry for systematic verification and validation. Such a comprehensive analysis of a liquid-cooled exascale supercomputer is the first of its kind. ExaDigiT elucidates complex transient cooling system dynamics, runs synthetic or real workloads, and predicts energy losses due to rectification and voltage conversion. Throughout our paper, we present lessons learned to benefit HPC practitioners developing similar digital twins. We envision the digital twin will be a key enabler for sustainable, energy-efficient supercomputing.

Brewer, Wes↗

ExaDigiT/RAPS

ExaDigiT is a framework for developing comprehensive digital twins of liquid-cooled supercomputers, which has three main modules: (1) a python-based Resource Allocator and Power Simulator (RAPS), (2) a Modelica-based Thermo-Fluidic cooling model, and (3) a C++-based augmented reality model built on Unreal Engine 5. RAPS either simulates workloads or replays historical workloads from system telemetry, and is able to predict dynamic energy consumption, as well as interact with the cooling model to predict cooling system behavior. Such a tool can be used together with reinforcement learning algorithms to provide an end-to-end optimization tool for data centers.

Brewer, Wesley [Oak Ridge National Laboratory (ORN↗

Transformational Challenge Reactor preconceptual core design studies

In the nuclear industry, a manufacturing-informed design approach has the potential to yield the most benefit from advanced manufacturing. By leveraging advanced materials, data science, and rapid testing and deployment, manufacturing-informed design can drive down costs and development times, ultimately improving future commercial viability. This approach is being demonstrated in the US Department of Energy Office of Nuclear Energy (DOE-NE) Transformational Challenge Reactor (TCR) program. Preconceptual design activities for TCR have been focused on analyzing and maturing four reactor core design concepts: two fast-spectrum and two thermal-spectrum systems. Furthermore, the designs were iteratively modified and analyzed, and subcomponents were manufactured in parallel over weeks instead of months or years. To meet key program initiatives (e.g., timeline and material use), several constraints—including fissile material availability, component availability, materials compatibility, and additive manufacturing capabilities—were factored into the design effort, yielding small cores less than one cubic meter in volume with near-term viability. Additionally, the TCR program has made significant progress on development of advanced moderator materials such as yttrium hydride, advancing the feasibility of gas-cooled thermal spectrum systems using less than 250 kg of high-assay low enriched uranium (HALEU) and occupying less than 1 m3. Each of the two resulting thermal designs uses a different fuel form: traditional UO2 ceramic fuel and tristructural isotropic (advanced TRISO) fuel particles embedded inside a SiC matrix. Core neutronics and thermal performance for these systems were assessed and summarized. Evaluation of the performance metrics for these two moderated designs has yielded the downselected TCR design: a TRISO-fueled and yttrium hydride moderated gas-cooled reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Energy characteristics of multi-chiller load distribution algorithms in a large office building

Here, this study evaluates the energy efficiency of multi-chiller systems in large office buildings, focusing on their optimization across various climate zones as defined by ASHRAE. Using EnergyPlus for simulations, the research examines five different load distribution algorithms in multi-chiller systems that range from one to ten chillers, aiming to understand their effectiveness in 15 distinct climate zones. The primary objectives of the study include identifying the energy efficiency of multi-chiller systems in each climate zone, determining the appropriate number of chillers for each zone, and evaluating the performance of the load distribution algorithms. Based on the U.S. Department of Energy’s commercial building model, the results suggest that multi-chiller systems can significantly reduce cooling energy consumption in various climates. Among the algorithms evaluated, the Sequential Uniform Part Load Ratio (SUPLR) algorithm demonstrates notable efficiency, especially in the 4A climate zone (Baltimore), where it achieves substantial energy savings. Applying the SUPLR algorithm in a multi-chiller setup with four chillers in this zone leads to an estimated 24.5 % reduction in energy usage, equivalent to 183 MW annually. The research indicates that a range of 3 to 5 chillers is typically optimal for most climate zones. In-depth analysis in the 4A climate zone highlights the importance of minimizing operation hours at low Part Load Ratios (PLR) to ensure that chillers operate at a high Coefficient of Performance (COP). This strategy underscores the potential of well-designed multi-chiller systems to reduce cooling energy demand, particularly in climates with transitional seasons. This study provides an overview of the energy-saving potential of multi-chiller systems, applicable across a variety of climatic scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Start-up and Emergency Shutdown Modeling for a Coal-fired 10MWe sCO₂ Power Plant

As part of a Phase II Front End Engineering Design (FEED) study for the DOE Fossil Fuel Large Scale Pilots program, investigations of novel start-up and emergency shutdown methods for a stoker-fed, coal-fired, 10MWe sCO₂ power plant proposal were performed. These investigations were performed using 1D transient system models of the plant created within the GT-SUITE system modeling platform. The system model components were created using vendor quotation data (heat exchangers), performance maps (turbomachines), or FMU models (fired heater). Previously, Echogen Power Systems (Echogen) has used a sCO₂ power cycle start-up method that fills the system with liquid CO₂ to facilitate easy use of an electrically-driven start pump to transition the system from initial CO₂ fill to turbo-compressor initialization. The novel start-up method presented attempts this transition with a minimal filling of the system with liquid CO₂, to reduce the total CO₂ inventory required. This method leaves the start pump vulnerable to a two phase inlet condition as system pressure is below the CO₂ saturation pressure for the condenser cooling water temperature (Tcw). System model cases at Tcw of 18°C, 26°C, and 32°C, corresponding to cold, design, and hot ambient days, were analyzed to determine if the SP inlet condition could be kept as a subcooled liquid and estimate the CO₂ inventory reduction amount./p> Stoker-fed, coal-fired heaters continue to emit heat for some time even after emergency shutdown from events such as a power failure. This heat emission would lead to a failure of the fired heater, as the metal overheats, if the CO₂ flow is shut off. The emergency shutdown method presented utilizes CO₂ vented by a controllable vent valve (CRV) to provide CO₂ cooling flow to the fired heater. To determine the effectiveness of this method at keeping the fired heater peak tubing metal temperature below the ASME material temperature limit, for pressures below 5 MPa, of 816 °C, system model cases with CRV diameters ranging from 4” to 10”, and an alternative CO₂ vent routing with CRV size of 6”, were investigated./p>

01 COAL, LIGNITE, AND PEAT↗

LCLS-II Helium Refrigeration System : A comprehensive overview of the project

SLAC National Accelerator Laboratory has upgraded to LCLS-II, featuring a 4 GeV superconducting accelerator composed of 37 cryomodules and two large helium refrigeration systems with a total cooling capacity of 8 kW at 2.0 K. The cryogenic system at SLAC is the successful outcome of a nine-year partnership between SLAC, Fermilab, and Jefferson Lab. This paper highlights the joint efforts between Jefferson Lab and SLAC in the development and implementation of the LCLS-II Cryogenic Plants. It details the project organization, schedule, budget, staffing profile and procurement strategy.

42 ENGINEERING↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

Comparison of the dielectric and magnetocaloric properties of bulk and film of GdFe 0.5 Cr 0.5 O 3

Here, we report a comparison of the magnetic, magnetocaloric, and dielectric properties of 50% iron substituted GdCrO 3 (GdFe 0.5 Cr 0.5 O 3 ) bulk pellet and 960 nm thick film of GdFe 0.5 Cr 0.5 O 3 (GFCO). The 960 nm film was synthesized on a platinized-silicon substrate by chem. soln. deposition and spin-coating methods. The X-ray diffraction scans of the bulk sample and the film as well as the morphology of the film as examined by the field-emission scanning electron microscope indicate phase-pure and polycrystalline nature of these samples. XPS was used to deermine the valence states of Gd, Fe, and Cr. The temp. dependence of the dielectric const. from 225 to 700 K shows peaks at T C = 525 K for the bulk and ≈450 K for the film due to ferroelectric to paraelectric transitions, since elec. polarization vs elec. field hysteresis loops are observed. at room temp. The dielectric studies in the bulk GFCO for T > T C indicate a relaxor-like behavior. The measurements of the magnetization (M) of the samples as a function of temp. (5-350 K) and magnetic field (H) up to 7 T (=70 kOe) depict hysteresis behavior at low temps. due to the canted antiferromagnetic order of Fe 3+ /Cr 3+ below the Néel temp. of ≈275 K. The M vs H isotherms at various temps. are used to det. and compare the magnetic entropy change (-ΔS) and relative cooling power (RCP) of the two samples, yielding (-ΔS) = 30.7 J/kg K (18.8 J/kg K) and RCP = 566.5 J/kg (375 J/kg) for the bulk (960 nm film) samples of GFCO at 7 K and 7 T, resp. The plot of RCP vs T shows that magnetic cooling for this system is most effective for T < 30 K. Comparatively smaller magnitudes of (-ΔS) and RCP for the film vis-a-vis the bulk sample of GFCO scale with its reduced magnetization. This suggests that further improvements in the quality of the films are needed to improve their magnetization and hence their magnetocaloric properties, possibly making them useful for on-chip cooling in miniaturized devices.

36 MATERIALS SCIENCE↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗