Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “consumption potential”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Energy and mobility impacts of connected autonomous vehicles with co-optimization of speed and powertrain on mixed vehicle platoons

Intersections are known to be traffic bottlenecks where a significant amount of energy consumption could be caused due to deceleration/acceleration in the presence of red signals. With an increased level of connectivity and automation of intelligent transportation systems, connected autonomous vehicles (CAVs) are expected to be able to proactively adjust their driving strategies subject to constraints imposed by the predicted future traffic. As a result, many potential benefits can be achieved, such as improved energy efficiency, enhanced traffic safety, among many others. Notably, the way CAVs are controlled affects the following legacy vehicles (LVs) due to complex traffic dynamics. Here, we are particularly interested in studying the energy and mobility impact of CAVs with an improved traffic prediction method on mixed vehicle platoons at various market penetration rates. Leveraging traffic prediction, CAVs are controlled with co-optimization of their speed and gear position. Specifically, a traffic prediction framework in a rolling horizon fashion is employed based upon a modified Payne–Whitham (PW) model capable of handling mixed traffic consisting of CAVs and LVs. The prediction error of the modified PW model is reduced by 53.62% compared to that of the standard PW model under test scenarios. According to the predicted traffic conditions, speed and gear position of CAVs are co-optimized with the primary goal of minimizing energy consumption when driving on a signalized arterial. The energy benefits achieved by CAVs and the impact of CAVs on LVs behind are studied comprehensively for mixed vehicle platoons. The lead LV follows a real-world speed profile collected on TH-55 in Minnesota. Numerical results show that energy benefits achieved by the vehicle platoon range from 2% to 16%, and a 1% to 5% reduction in travel time for LVs behind CAVs is also observed, at different penetration rates of CAVs in various traffic scenarios. Furthermore, it is observed that CAVs using the proposed eco-driving approach appear to have a positive impact on the LVs behind in terms of energy consumption, regardless of the driving styles of the LVs ahead.

33 ADVANCED PROPULSION SYSTEMS↗

Exploring Class 8 Long-Haul Truck Electrification: Key Technology Evaluation and Potential Challenges

The phenomena of global warming and climate change are encouraging more and more countries, local communities, and companies to establish carbon neutrality targets, which has very significant implications for the US trucking industry. Truck electrification helps fleets to achieve zero tailpipe emissions and macro-scale decarbonization while allowing continued business growth in response to the rapid expansion of e-commerce and shipping related to increased globalization. Here, this paper presents an analysis of Class 8 long-haul truck electrification using a commercial vehicle electrification evaluation tool and Fleet DNA drive data. The study provides new insight into the impacts of streamlined chassis, battery energy density, and superfast charging on battery capacity needs as well as implications for payload, energy consumption, and greenhouse gas emissions for electric long-haul trucks. The study also identifies a pathway for achieving optimal long-haul truck electrification. The results show that no single technology can simultaneously achieve significant improvements in all these key areas and that a cost-effective approach requires a deliberate combination of all of these technologies. Moreover, the analysis highlights the strong evolution of vehicle and battery technologies and the excellent potential for long-haul truck electrification to achieve 100% year-round service coverage with continued technology advancement.

33 ADVANCED PROPULSION SYSTEMS↗

Electric and Hydraulic Propel Torque Modulation for a Compact Track Loader With the Hybrid Hydraulic Electric Architecture (HHEA)

Abstract The Hybrid Hydraulic Electric Architecture (HHEA) has previously been proposed for off-highway vehicles to reap the efficiency and controllability benefits of electrification without needing very large electric motors. This is achieved with the use of a set of selectable common pressure rails to transmit the majority of power and small electric motors to modulate that power. Previous work has shown significant energy savings for the work circuits of a variety of machines. In this paper, the energy saving potential of HHEA for the propel circuit of a compact track loader is studied. The ports of the track hydraulic motors are selectably connected to the common pressure rails, and instead of using the electric assist motors to buck/boost pressure, as in HHEA for linear actuators, small electric assist motors are used to add/subtract torque directly. The interplay between the torque limits of the electric motors and the ability of the hydraulic motor to vary displacements is studied, along with the effect these factors have on energy saving potential. It is found that the ability to vary the displacement of the hydraulic motor allows for: more efficient electric motor operating conditions, reduced electric torque requirement, and reduced pressure rail switching events. All three of these advantages can be achieved at once using variable displacements; but trade-offs exist between these advantages (i.e. improved efficiency can be achieved at the expense of a larger electric torque requirement). Overall, the HHEA can reduce energy consumption by ∼ 36% compared to the stock machine, depending on the hydraulic motor’s ability to vary displacements, and assuming the electric motor torque is limited to 20% of that required in a direct electrification scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Consumption and Cost Reduction of Future Light-Duty Vehicles through Advanced Vehicle Technologies: A Modeling Simulation Study Through 2050

The U.S. Department of Energy’s (DOE’s) Vehicle Technologies Office (VTO) and Hydrogen and Fuel Cell Technologies Office (HFTO) aim to develop sustainable, affordable and efficient technologies for transportation of goods and people. Translating investments in advanced transportation component technologies and powertrains to estimate vehicle-level fuel savings potential is critical for understanding DOE’s impact. In this work, we simulated technologies funded by VTO and HFTO for light duty vehicles. The simulations were performed across: Multiple powertrain configurations (i.e., conventional, power-split, extended-range electric vehicle, battery electric drive, and fuel-cell vehicles), Vehicle classes (i.e., compact car, midsize car, small sport utility vehicle [SUV], midsize SUV, and pickup trucks); and Fuels (i.e., gasoline, diesel, hydrogen, and battery electricity). These various technologies are assessed for six different timeframes: laboratory years 2015, 2020, 2025, 2030, and 2045. A delay of 5 years is assumed between laboratory year and model year (year technology is introduced into production). Finally, uncertainties are included for both technology performance and cost aspects by considering two cases: Low case, aligned with DOE technology manager estimates of expected original equipment manufacturer (OEM) improvements based on regulations, business as usual; and High case, aligned with aggressive technology advancements based on R&D targets developed through support by VTO & HFTO. These scenarios are not intended as predictions of future performances. The energy and cost impact of different technologies were estimated using Autonomie (www.autonomie.net), Argonne vehicle system simulation tool. Autonomie is a state-of-the-art vehicle system simulation tool used to assess the energy consumption, performance and cost of multiple advanced vehicle technologies across classes (from light to heavy duty), powertrains (from conventional to HEVs, FCEVs, PHEVs and BEVs), components and control strategies. Autonomie is packaged with a complete set of vehicle models for a wide range of vehicle classes, powertrain configurations and component technologies, including vehicle level and component level controls. These controls were developed and calibrated using dynamometer test data. Autonomie has been used to support a wide range of studies including analyzing various component technologies, sizing powertrains components for different vehicle requirements, comparing the benefits of powertrain configurations, optimizing both heuristic and route based vehicle energy control and predicting transportation energy use when paired with a traffic modeling tool such as POLARIS. This report documents the assumptions and estimates the vehicle-level energy consumption benefits and associated technology costs for the various types of light duty vehicles. All details of vehicle assumptions and simulation results are available in the spreadsheets accompanying this report.

33 ADVANCED PROPULSION SYSTEMS↗

Upgrading Biogas through in situ Conversion of Carbon Dioxide to Biomethane in Anaerobic Digesters

Organic waste streams generated by wastewater treatment plants, agricultural operations, and food processing industries represent an important yet underutilized opportunity for renewable energy production in the United States. Through anaerobic digestion, these waste streams can produce biogas, a mixture primarily composed of methane (CH4) and carbon dioxide (CO2), that can be upgraded to pipeline-quality natural gas. However, most existing upgrading technologies remove CO2 from biogas rather than utilizing it, leaving a significant portion of the potential energy unused. This project investigates a novel biological upgrading approach that converts CO2 into additional CH4 by supplying hydrogen (H2) to specialized microorganisms capable of performing hydrogenotrophic methanation. The main challenges associated with biological biogas upgrading are related to hydrogen supply, gas-liquid mass transfer, and process stability. First, due to the high cost of hydrogen gas, it is preferable that H2 be produced on-site using renewable energy sources such as wind or solar power. Second, hydrogen has low solubility in liquids, which limits its availability to microorganisms and requires strategies to improve gas dissolution and transfer within the reactor. Third, process inhibition may occur as a result of increased pH caused by CO2 consumption or elevated H2 partial pressure, both of which can negatively affect methanogenic activity. Although research in these areas has advanced during the course of this project, these challenges have not yet been fully resolved. To date, the biological systems that have achieved the highest methane concentrations are typically ex-situ reactors, where operational conditions can be more easily controlled. For this reason, the findings of the present project remain highly relevant. The project goal was to develop an innovative system that can accomplish biogas upgrading via biological conversion of CO2 to CH4, in a novel hybrid approach that combines the advantages of both in-situ and ex-situ systems. The proposed system employs a three-phase upflow anaerobic bioreactor with H2 delivery through a gas-permeable membrane, enabling efficient hydrogen transfer and microbial conversion. Under optimized operating conditions, the system achieved 99% H2 consumption and 90% CO2 conversion. A subsequent gas cleaning stage was implemented to further improve gas quality and meet target purity standards. The upgraded gas composition reached 97.7% CH4, 2.2% CO2, and 0.97% O2, while H2S concentrations remained below detection limits. In addition, a flue gas-driven inorganic thermoelectric generator (TEG) system was designed and experimentally validated as a potential source of electricity for H2 production. The system consisted of six TEG modules connected in series and achieved an open-circuit voltage of 4.5 V and a maximum power output of 224 mW at a temperature difference of approximately 53.5 °C, demonstrating effective conversion of waste heat into electrical power under simulated flue gas conditions. Finally, a comprehensive techno-economic analysis was completed to evaluate the capital and operating costs associated with the proposed system. The results provide important insights to guide future scale-up, optimization, and potential deployment of integrated biological biogas upgrading technologies.

09 BIOMASS FUELS↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

Quantum Sensing for Energy Applications: Review and Perspective

On its revolutionary threshold, quantum sensing is creating potentially transformative opportunities to exploit intricate quantum mechanical phenomena in new ways to make ultrasensitive measurements of multiple parameters. Concurrently, growing interest in quantum sensing has created opportunities for its deployment to improve processes pertaining to energy production, distribution, and consumption. Safe and secure utilization of energy is dependent upon addressing challenges related to material stability and function, secure monitoring of infrastructure, and accuracy in detection and measurement. A summary of well-established and emerging quantum sensing materials and techniques, as well as the corresponding sensing platforms that have been developed for their deployment is provided here. Specifically, the enhancement of existing advanced sensing technologies with quantum methods and materials is focused on, enabling the realization of an unprecedented level of sensitivity, placing an emphasis on relevance to the energy industry. The review concludes with a discussion on high-value applications of quantum sensing to the energy sector, as well as remaining barriers to sensor deployment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Design and Techno-Economic Analysis of 3D-Printed, Intensified Packings for Absorbers and Strippers in Solvent-Based CO 2 Capture

A potential technology for the CO 2 absorption process is utilizing intensified structured packing with embedded cooling/heating channels for continuous heat exchange, which can overcome limitations of discrete methods, such as discrete intercooling and centralized reboilers, to aid in reducing energy consumption and decreasing costs. This work investigates the modeling of intensified packing (IP) for the stripper tower, extending on previous work for the absorber, which distributes heat internally within the column, improving the thermodynamics for the solvent regeneration process. The model includes submodels for steam turbine extraction to produce steam at various qualities as well as a surrogate model for calculating steam enthalpy. A cost model for a plant-scale absorption capture process was developed, allowing for the design of the plant to be optimized, subject to minimizing capture cost using two different power plant flue gas sources. In this optimization, the placement of IP in both towers is optimized to balance the trade-off between enhanced heat transfer and reduced mass transfer volume. For natural gas combined cycle flue gas, the standard process configuration had a minimum cost of $\$$65.40/tonne CO 2 , and considering IP, the minimum capture cost is reduced to $\$$62.73/tonne, with utilization in the stripper column, which reduces yearly costs by up to $\$$2.67 MM/yr. Cooling the absorber through IP, or intercoolers, was only found to be beneficial at higher capture rates, with IP in both towers having a cost of capture of $\$$68.08/tonne at 99.9% capture, a reduction of $\$$12.64/tonne when using only intercoolers at the same capture rate. When capturing from pulverized-coal power plants, the minimum cost of capture when using IP in both towers is $\$$44.18/tonne (at 97% capture), while the standard configuration with and without intercoolers was $\$$45.69 and $\$$47.22 per tonne, respectively. This results in a reduction in yearly costs of $\$$16.98 MM/yr from the base-case configuration. At this higher CO 2 concentration, cooling in the absorber from the IP becomes extremely beneficial, reducing energy consumption by up to 6%.

20 FOSSIL-FUELED POWER PLANTS↗

Fluidized-Bed Gasification of Coal-Biomass-Plastics for Hydrogen Production

Coal is one of the most abundant fossil energy resources in the United States and in the world. The recoverable reserves in the United States are estimated to be about 252 billion tons – more than 350 years of supply at current rates of usage. However, the share of coal in total primary energy consumption in the US has been declining over the years. The decline of coal is mainly attributed to cheap natural gas and precipitous declines in the cost of electricity production from renewable technologies such as wind and solar. Coal can potentially be used if it is coupled with carbon-neutral feedstock such as biomass-agricultural residues, forest biomass, and forest residues. Co-gasification of coal and biomass can become a negative carbon emission technology if the carbon dioxide (CO 2 ) is captured and sequestered. Although the biomass gasification process has a lot of similarities to coal gasification, the large-scale adaptation of power production sourced from biomass has not come to fruition. The main reason is that the power production from biomass is still expensive when compared with natural gas or coal power technologies. To address the feedstock cost, one approach is to use low-cost feedstocks, such as municipal solid wastes (MSW) or plastics, for gasification. Gasification involves the partial oxidation of coal and/or biomass feedstocks to produce a combustible fuel called synthesis gas (syngas) which is composed of carbon monoxide (CO), hydrogen (H 2 ), CO 2 , methane (CH 4 ), nitrogen (N 2 ), water (H 2 O), and other compounds that might be considered as contaminants. Raw syngas from gasification must go through multiple steps to produce high-purity hydrogen. The specific steps depend upon the quality (gas composition, contaminants, and their concentration) and condition (pressure and temperature) of syngas. The long-term goal of the project was to utilize coal and plastics together with biomass to produce energy and fuels using a gasification platform while reducing greenhouse gas emissions. The main objective of this research was to examine gasification performance in a laboratory-scale fluidized-bed gasifier for hydrogen production. The specific objectives of the research were to: (i) study coal-plastic-biomass mixture flowability for consistent feeding in the gasifier; (ii) understand the gasification behavior of the mixture in steam and oxygen environments; (iii) perform thermal property characterization of ash and slag from the mixture feedstock and refractory-ash interface of the mixture under gasification conditions; and (iv) develop process models to determine the technology needed for syngas cleanup and contaminants. The study found that there was no apparent segregation when biomass, coal, and waste plastics were mixed together during feeding. Although there were differences in hydrogen production when individual feedstock were fed, the hydrogen concentration remained almost constant with various blends. Therefore, blending waste plastics with biomass and coal, which are all abundant, is a better approach for energy production. Results of the techno-economic analysis suggested that integration of advanced gasification (GTI’s R-GAS™) and syngas cleanup and conditioning technologies (RTI’s WDP and AFWGS) for clean hydrogen production resulted in substantial benefits, including significant capital cost and operating cost reductions. Advanced technologies resulted in 16% reduction in the hydrogen production cost (COH) from 2.94 $\$$/kg to 2.47 $\$$/g, with further scope for optimization and cost reduction. These advanced technologies also result in lower emissions, and improved energy efficiency.

01 COAL, LIGNITE, AND PEAT↗

Quantum Sensing for Energy Applications

Quantum sensing is creating potentially transformative opportunities to exploit intricate quantum mechanical phenomena in new ways to make ultrasensitive measurements of multiple parameters. A growing interest in quantum sensing has created opportunities for its deployment to improve processes pertaining to energy production, distribution, and consumption. NETL is leveraging experimental and computational quantum tools to enhance sensitivity of hybrid quantum-classical ultrasensitive sensors for the detection of hydrocarbons and rare earth elements (REEs).

Paudel, Hari P.↗

Equipment List Comparing Balance of Plant Containing a Heat Pump against a Reference Electricity Generating Plant

Approximately two-thirds of U.S. energy consumption in the industrial and transportation sectors relies on fossil fuels. These sectors require high-quality heat, i.e., thermal energy at very high temperatures, for molecular transformation processes. The Integrated Energy Systems (IES) program aims to assess the economic potential of utilizing nuclear-grade heat from Advanced Reactors (ARs) to meet the high-quality heat demands. By having industrial processes (IPs) supplied with nuclear-generated heat, manufacturers could benefit from more stable and potentially lower energy costs, reducing reliance on volatile fossil fuel markets. The main outcome of the FY24 research was the thermodynamic assessment and gap analysis of steam generation for IP applications. The study completed in June 2024 demonstrated that the required steam temperatures could be achieved by integrating a heat pump into an AR power plant. After identifying the thermal demands of target IPs, multiple balance of plant configurations for the Xe-100 reactor by X-energy, incorporating a heat pump, were analyzed. Their technical feasibilities were assessed, including the design of suitable axial compressors for these applications. Comparative performance analysis showed that thermal efficiency alone is insufficient to evaluate system suitability. To address this, a new indicator (heat factor) was introduced in the report released in September 2024 to quantify the low-quality thermal power needed to produce one unit of high-quality heat for the IP. Results showed that integrating heat pumps into Rankine cycles enables higher steam temperatures, though at the expense of increased thermal energy input. This report builds upon and completes the foundational work previously undertaken. It focuses on the design of two Balance of Plant (BOP) configurations, both based on Rankine energy conversion cycles: “Case 1”, which involves electricity generation only, and “Case 2”, which combines electricity and high-temperature heat generation for industrial use. For each configuration, a comprehensive equipment list was developed, detailing all major components such as turbines, compressors, heat exchangers, pumps, and control systems. These lists will serve as the basis for future comparative cost analyses, with the goal of assessing the number and type of components required to integrate a heat pump into the Rankine cycle and to establish a heat transport system capable of delivering thermal energy from the nuclear plant to an industrial facility. Using the constitutive equations presented in the June 2024 milestone, the operating conditions of all BOP components for both “Case 1” and “Case 2” were evaluated. These parameters—such as temperature, pressure, mass flow rate, and steam quality—served as the basis for calculating the associated thermal and mechanical power flows. The net power required from the heat pump to raise the steam temperature to the target level was also determined. The thermodynamic performance of the configuration was then assessed using the heat factor metric. The key outcome of this analysis is a comparative table that presents the equipment that was used in the “Case 1” and “Case 2” configurations. This study offers a preliminary comparison of the two designs, providing insight into the impact of integrating a heat pump in terms of component requirements and thermal efficiency. This equipment list, together with the evaluated operating conditions, also serves as a foundation for the economic analyses scheduled for the current fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessing the physical potential capacity of direct air capture with integrated supply of low-carbon energy sources

Direct Air Capture (DAC) is a negative emission technology that can remove up to 10–20 Gt of CO 2 per year. However, to achieve this potential, DAC systems must be coupled to suitable locally available energy sources and sited near geological storage. Here this study explores the potential of low-carbon energy sources to supply power and heat to the DAC process in a dedicated, self-sufficient system tailored for each energy source. Solar, geothermal, woody biomass, wind, and nuclear energy sources are assessed for their global energy supply potential and possible land use requirements. While the options differ in area requirement and regional efficacy, we estimate that all the regionally specific technologies considered can supply energy to achieve significant removal of carbon dioxide from the atmosphere globally. The amount of energy physically available from solar, offshore wind, and woody biomass converts to a removal potential of 160–971, 45–150, and 2–5 Gt CO 2 /year, respectively. Thus, negative emission targets can be reached by utilizing a moderate fraction of the overall potential of several different low-carbon energy sources for DAC while the magnitude of the potential changes significantly according to the source of energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-term carbon emission reduction potential of building retrofits with dynamically changing electricity emission factors

Buildings account for approximately 36% of the United States' total carbon emissions and building retrofits have great potential to reduce carbon emissions. Current research adopts a constant electricity emission factor although it changes over time due to the increase of renewable energy generation. Here, to accurately predict emission reduction potential of building retrofits, this study develops a novel method by using dynamically changing electricity emission factors. Using medium office buildings as an example, we predicted emission reduction of eight building retrofit measures from 2020 to 2050 in five locations in the U.S. with distinct climates and renewable adoption rates. To evaluate emission reduction potential sensitivity to the compositions of electricity generation, five scenarios for renewable energy adoptions are investigated. The results reveal several new phenomena on emission reduction potential of building retrofits for medium offices in the U.S.: (1) it decreases from 2026 to 2050; (2) it has the same trend with coal usage; and (3) it reaches the maximum under the high renewable cost scenario. Based on the results, it is recommended that building retrofits should focus on 1) improving lighting and equipment efficiency; 2) locations with higher coal usage rate, and 3) buildings under the high renewable cost scenario. The new method can also be used for predicting emission reduction potential of the building sector in the U.S. by applying to other building types and regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Research note: LED lighting – A global enterprise

There is considerable focus on technology manufacturing locations and the value in funding innovation when upstream products are not manufactured within a domestic economy. Light-emitting diodes (LEDs) are such an upstream product. Here, we evaluate the value added along the supply chain of luminaires, a product that utilizes LEDs, using bottom-up cost modelling. Coupling the results with analysis of shipping cost and time, this analysis examines how advances in LEDs can incentivize LED luminaire adoption leading to the potential for significant domestic manufacturing effects even if the upstream products are produced in other economies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Integrated Control Method for Supplemental Minisplit Heat Pumps in Existing Homes

The FSEC Energy Research Center(FSEC) at the University of Central Florida has investigated low-cost space-conditioning upgrade solutions for existing homes since 2014. The retrofits involve installing a modest capacity, centrally located, high efficiency, ductless, minisplit heat pump (MSHP) for use in conjunction with the home’s existing central space conditioning system (CSCS). This type of retrofit targets homes with older but not obsolete CSCSs that have not reached end of life, and presents a more cost-effective option to achieve space conditioning energy savings than outright CSCS replacement. This report describes results from investigating the energy savings potential, given adherence to comfort management, if the control of the MSHP and CSCS were integrated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stable Cadmium-Free Quantum Dot Optical Down-Converters for Solid State Lighting

Quantum dots (QDs) have been used in commercial solid-state lighting (SSL) applications to improve the energy efficiency of light generation at warm color temperatures. By increasing the amount of QDs used in each product, further energy savings are possible; however, traditional QDs contain cadmium, which has regulatory limits on its concentration in consumer products. As described within this final technical report, we have established that heavy-metal free QDs made from indium phosphide (InP) exhibit highly efficient emission at the temperatures and fluxes relevant to SSL. However, the maintenance of this emission is compromised during long term operation due to QD oxidation. We have identified multiple methods to slow the oxidation rate, which has improved the operational stability of these materials more than 200 times longer than at the project start. Beyond these improvements, heavy-metal free QDs require a further hundred-fold increase in stability to enable use in mid-power SSL and a ten-fold increase in stability to enable use in diffuse SSL applications. The outcomes of this project demonstrate feasibility for the use of heavy-metal free QDs in commercial SSL applications with potential use in diffuse SSL applications in the near term (1-2 years) pending market need.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗