Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Deep Learning Model Segmentations on Computed Tomography 3D Reconstructions of Coffee Beans to Determine Void Ratio (U-Net) and Roast Level (LinkNet)

This project will evaluate the functionality of Object Research Dragonfly software’s user produced deep learning (DL) models on Computed Tomography (CT) scanned coffee beans from green (unroasted) through a dark roast. DL models will be expected to identify voids within the coffee beans, and identify the level of roast of the bean from the CT reconstruction. The scope of this project is intended to meet the Capstone Project requirements of University of California San Diego (UCSD) Structural Engineering master’s degree and offer useful insight on Dragonfly’s DL capability for LANL’s Non-Destructive Evaluation (NDE) CT team. The results of this project will be presented to the E-6 NDE group within LANL. Data acquisition was completed with a North Star Imaging (NSI) X-25 CT Cabinet.

97 MATHEMATICS AND COMPUTING↗

A Comparison of Lumpectomy Cavity Delineations Between Use of Magnetic Resonance Imaging and Computed Tomography Acquired With Patient in Prone Position for Radiation Therapy Planning of Breast Cancer

Purpose: To compare lumpectomy cavity (LC) and planning target volume (PTV) delineated with the use of magnetic resonance imaging (MRI) and computed tomography (CT) and to examine the possibility of replacing CT with MRI for radiation therapy (RT) planning for breast cancer. Methods and Materials: MRI and CT data were acquired for 15 patients with early-stage breast cancer undergoing lumpectomy during RT simulation in prone positions, the same as their RT treatment positions. The LCs were delineated manually on both CT (LC-CT) and MRI acquired with 4 sequences: T1, T2, STIR, and DCE. Various PTVs were created by expanding a 15-mm margin from the corresponding LCs and from the union of the LCs for the 4 MRI sequences (PTV-MRI). Differences were measured in terms of cavity visualization score (CVS) and dice coefficient (DC). Results: The mean CVSs for T1, T2, STIR, DCE, and CT defined LCs were 3.47, 3.47, 3.87, 3.50. and 2.60, respectively, implying that the LC is mostly visible with a STIR sequence. The mean reductions of LCs from those for CT were 22%, 43%, 36%, and 17% for T1, T2, STIR, and DCE, respectively. In 14 of 15 cases, MRI (union of T1, T2, STIR, and DCE) defined LC included extra regions that would not be visible from CT. The DCs between CT and MRI (union of T1, T2, STIR, and DCE) defined volumes were 0.65 ± 0.20 for LCs and 0.85 ± 0.06 for PTVs. There was no obvious difference between the volumes of PTV-MRI and PTV-CT, and the average PTV-STIR/PTV-CT volume ratio was 0.83 ± 0.23. Conclusions: The use of MRI improves the visibility of LC in comparison with CT. The volumes of LC and PTV generated based on a MRI sequence are substantially smaller than those based on CT, and the PTV-MRI volumes, defined by the union of T1, T2, STIR, and DCE, were comparable with those of PTV-CT for most of the cases studied.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-JeP4-06: Evaluation of Interfractional and Intrafractional Tumor Motion in Stereotactic Liver Radiotherapy, Based On Four-Dimensional Cone-Beam Computed Tomography Using Fiducial Markers

Purpose: The purpose of this study was to evaluate the interfractional and intrafractional motion of liver tumors in stereotactic body radiation therapy (SBRT), based on four-dimensional cone-beam computed tomography using fiducial markers. (4D-CBCT). Methods: Seven patients with liver tumors were treated by SBRT with abdominal compression (AC) in five fractions with image guidance based on 4D-CBCT. The 4D-CBCT studies were performed to determine the individualized internal margin for the planning simulation. The interfractional and intrafractional changes of liver tumor motion for all patients was measured, based on the planning simulation 4D-CBCT, pre-SBRT 4D-CBCT, and post-SBRT 4D-CBCT. The interfractional motion change was calculated from the difference in liver tumor amplitude on pre-SBRT 4D-CBCT relative to that of the planning simulation 4D-CBCT for each fraction. The intrafractional motion change was calculated from the difference between the liver tumor amplitudes of the pre- and post-SBRT 4D-CBCT for each fraction. Significant interfractional and intrafractional changes in liver tumor motion were defined as a change ≥3 mm. Statistical analysis was performed using the Pearson correlation. Results: The values of the mean amplitude of liver tumor, as indicated by planning simulation 4D-CBCT, were 1.6 ± 0.8 mm, 1.6 ± 0.9 mm, and 4.9 ± 2.2 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively. Pearson correlation coefficients between the liver tumor amplitudes, based on planning simulation 4D-CBCT, and pre-SBRT 4D-CBCT during fraction treatment in the LR, AP, and SI directions were 0.6, 0.7, and 0.8, respectively. Interfractional and intrafractional motion changes of ≥3 mm occurred in 23% and 3% of treatment fractions, respectively. Conclusion: The interfractional and intrafractional changes of liver tumor motion were small in most patients who received liver SBRT with AC. In addition, planning simulation 4D-CBCT was useful for representing liver tumor movement in patients undergoing SBRT. This work was supported by JSPS KAKENHI Grant Number 26861004.

60 APPLIED LIFE SCIENCES↗

Convolutional Neural Network for Segmenting Micro-X-ray Computed Tomography Images of Wood Cellular Structures

To further enhance the performance of wood products, improved tools are needed to study in situ cellular scale phenomena like mechanical deformations and moisture swelling. Micro-X-ray computed tomography (μXCT) using brilliant synchrotron light sources now has the spatial and temporal resolution for real-time visualization of phenomena in three-dimensional cellular structures. However, the tradeoff for speed includes the loss of intensity contrast between different types of materials within the imaged structure, such as cell wall and air in wood. This loss of contrast prevents traditional histogram-based segmentation methods from being used effectively. A new convolutional neural network (CNN) approach was therefore developed to segment fast μXCT images of wood into cell wall and air volumes. The fast μXCT and segmentation were demonstrated in the study of moisture swelling in loblolly pine (Pinus taeda) earlywood and latewood cellular structures conditioned at 0%, 33%, 75%, and 95% relative humidity (RH). The CNN segmentation results had a mean intersection over union (IoU) metric accuracy of 96%. Initial analysis of the swelling in the latewood revealed cell walls swelled about 25% when conditioned from 0% to 95% RH. Additionally, the widths of ray cell lumina in the transverse plane of latewood could be observed to increase at higher RH. The segmentation method presented here will facilitate future quantitative analyses in in situ μXCT studies of wood and other similar cellular materials.

Arzola-Villegas, Xavier (ORCID:0000000305369766)↗

Domain identification in impedance computed tomography by spline collocation method

A method for estimating an unknown domain in elliptic boundary value problems is considered. The problem is formulated as an inverse problem of integral equations of the second kind. A computational method is developed using a splice collocation scheme. The results can be applied to the inverse problem of impedance computed tomography (ICT) for image reconstruction.

Kojima, Fumio↗

LATTE: open-source, high-performance traveltime computation, tomography and source location in acoustic and elastic media

Traveltime-based tomography and source location are fundamental approaches for imaging subsurface structures and understanding the spatiotemporal distribution of seismicity from local to global scales. We present an open-source, high-performance framework integrating eikonal equation solvers and adjoint-state theory for traveltime computation, velocity tomography, source location and joint tomography-location in 2-D/3-D acoustic and elastic media. We introduce novel regularization schemes based on total generalized p-variation, structural similarity and multitask machine learning to enhance the fidelity and interpretability of inverted models and source locations. Key features of our implementation also include the ability to leverage both absolute-difference and double-difference traveltime misfits for high-fidelity velocity tomography and source parameter estimation; support for traveltime computation and inversion in diverse 2-D/3-D scenarios with arbitrary source and receiver distributions; and a perturbation-based optimal step-size estimation method to reduce computational costs. In addition, our implementation employs shared-memory and distributed-memory parallelization to provide an efficient solution for traveltime computation, tomography, and source location. In conclusion, we validate the efficacy and accuracy of our approach through multiple synthetic data examples.

58 GEOSCIENCES↗

X-ray computed tomography of microstructure evolution during matrix impregnation and curing in unidirectional fiber beds

Microstructural evolution during axial impregnation and subsequent curing of a preceramic polymer in unidirectional ceramic fiber beds is studied using X-ray computed tomography. The principal goal is to identify connections between void locations, void sizes, local fiber bed porosity, fiber movement, and impregnation conditions. The degree of saturation after impregnation is found to increase with instantaneous capillary number. But, because of the need to create pathways for gas escape during curing, fiber beds with high saturation after impregnation show the largest reductions in saturation during curing. Notwithstanding, saturation after curing increases with instantaneous capillary number. Voids tend to form in the largest channels between fibers, where the local fiber bed porosity is high, during both impregnation and curing. Here, void formation is typically accompanied by fiber movement that increases both the local fiber bed porosity near voids and the overall non-uniformity in the fiber bed, as measured by local porosity entropy.

(A - Material) fibers↗

Methods and compositions for protection of cells and tissues from computed tomography radiation

Described are methods for preventing or inhibiting genomic instability and in cells affected by diagnostic radiology procedures employing ionizing radiation. Embodiments include methods of preventing or inhibiting genomic instability and in cells affected by computed tomography (CT) radiation. Subjects receiving ionizing radiation may be those persons suspected of having cancer, or cancer patients having received or currently receiving cancer therapy, and or those patients having received previous ionizing radiation, including those who are approaching or have exceeded the recommended total radiation dose for a person.

59 BASIC BIOLOGICAL SCIENCES↗

Methods and compositions for protection of cells and tissues from computed tomography radiation

Described are methods for preventing or inhibiting genomic instability and in cells affected by diagnostic radiology procedures employing ionizing radiation. Embodiments include methods of preventing or inhibiting genomic instability and in cells affected by computed tomography (CT) radiation. Subjects receiving ionizing radiation may be those persons suspected of having cancer, or cancer patients having received or currently receiving cancer therapy, and or those patients having received previous ionizing radiation, including those who are approaching or have exceeded the recommended total radiation dose for a person.

Grdina, David J.↗

Analysis of Prostate Bed Motion Using Daily Cone-Beam Computed Tomography During Postprostatectomy Radiotherapy

Purpose: To report on the interfraction total positioning error of the postoperative prostate bed and to quantify its components (bony misalignment [BM]and prostate bed motion [PBM]) using daily kilovoltage cone-beam computed tomography (CBCT). The role of an adaptive radiotherapy schedule (ART) was investigated. Methods and Materials: A total of 547 daily CBCT images from 15 consecutive patients who had been treated with prostate bed radiotherapy were retrospectively analyzed. The positioning error was measured by rigid co-registration of the daily CBCT with pretreatment CT planning scan. The total positioning error was quantified by co-registration of the CBCT with the CT planning scan to match the anterior rectal wall. Automatic bony pelvis co-registration was performed to separate BM and PBM. The ART was determined by the average total positioning error from the first 5 CBCT images. Results: The systematic error for the total positioning error in the left-right, superoinferior, and anteroposterior direction was 2.69, 2.00, and 2.65 mm with a random error of 1.99, 1.49, and 2.25 mm, resulting in a planning target volume margin of 8, 6, and 8 mm, respectively. ART reduced the margin by 54%, 44%, and 40%, respectively. Systematic errors in the left-right, superoinferior, and anteroposterior direction for BM was 2.66, 1.83, and 2.60 mm and for PBM was 0.44, 0.92, and 2.50 mm with a random error of 1.88, 1.24, and 1.77 mm for BM and 0.99, 1.38, and 2.32 mm for PBM, respectively. Conclusion: Without treatment verifications, 6-8-mm planning target volume margins are required because of PBM and BM. The anteroposterior PBM was significant. An ART protocol can reduce these planning target volume margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Functional Marrow Irradiation Based on Skeletal Marrow Composition Obtained Using Dual-Energy Computed Tomography

Purpose: To develop an imaging method to characterize and map marrow composition in the entire skeletal system, and to simulate differential targeted marrow irradiation based on marrow composition. Methods and Materials: Whole-body dual energy computed tomography (DECT) images of cadavers and leukemia patients were acquired, segmented to separate bone marrow components, namely, bone, red marrow (RM), and yellow marrow (YM). DECT-derived marrow fat fraction was validated using histology of lumbar vertebrae obtained from cadavers. The fractions of RM (RMF = RM/total marrow) and YMF were calculated in each skeletal region to assess the correlation of marrow composition with sites and ages. Treatment planning was simulated to target irradiation differentially at a higher dose (18 Gy) to either RM or YM and a lower dose (12 Gy) to the rest of the skeleton. Results: A significant correlation between fat fractions obtained from DECT and cadaver histology samples was observed (r=0.861, P<.0001, Pearson). The RMF decreased in the head, neck, and chest was significantly inversely correlated with age but did not show any significant age-related changes in the abdomen and pelvis regions. Conformity of radiation to targets (RM, YM) was significantly dependent on skeletal sites. The radiation exposure was significantly reduced (P<.05, t test) to organs at risk (OARs) in RM and YM irradiation compared with standard total marrow irradiation (TMI). Conclusions: Whole-body DECT offers a new imaging technique to visualize and measure skeletal-wide marrow composition. The DECT-based treatment planning offers volumetric and site-specific precise radiation dosimetry of RM and YM, which varies with aging. Our proposed method could be used as a functional compartment of TMI for further targeted radiation to specific bone marrow environment, dose escalation, reduction of doses to OARs, or a combination of these factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Performance of Radiographic Criteria for Bone Malignancy When Applied to Computed Tomography and Magnetic Resonance Imaging

The conventional radiologic features that differentiate benign from malignant bone lesions were originally described using radiography (x-ray [XR]). When evaluating sectional imaging studies such as magnetic resonance imaging (MRI) and computed tomography (CT), one may apply these principles to identify malignant bone lesions. The aim of this study was to evaluate the performances of these radiographic features for detecting malignity when applied to CT and MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Evaluation Between Megavoltage Cone-Beam Computed Tomography and Body Mass Index for Intracranial, Thoracic, and Pelvic Localization

The aim of this study was to evaluate radiation dose for organs at risk (OAR) within the cranium, thorax, and pelvis from megavoltage cone-beam computed tomography (MV-CBCT). Using a clinical treatment planning system, CBCT doses were calculated from 60 patient datasets using 27.4 x 27.4 cm{sup 2} field size and 200{sup o} arc length. The body mass indices (BMIs) for these patients range from 17.2-48.4 kg/m{sup 2}. A total of 60 CBCT plans were created and calculated with heterogeneity corrections, with monitor units (MU) that varied from 8, 4, and 2 MU per plan. The isocenters of these plans were placed at defined anatomical structures. The maximum dose, dose to the isocenter, and mean dose to the selected critical organs were analyzed. The study found that maximum and isocenter doses were weakly associated with BMI, but linearly associated with the total MU. Average maximum/isocenter doses in the cranium were 10.0 ({+-} 0.18)/7.0 ({+-} 0.08) cGy, 5.0 ({+-} 0.09)/3.5 ({+-} 0.05) cGy, and 2.5 ({+-} .04)/1.8 ({+-} 0.05) cGy for 8, 4, and 2 MU, respectively. Similar trends but slightly larger maximum/isocenter doses were found in the thoracic and pelvic regions. For the cranial region, the average mean doses with a total of 8 MU to the eye, lens, and brain were 9.7 ({+-} 0.12) cGy, 9.1 ({+-} 0.16) cGy, and 7.2 ({+-} 0.10) cGy, respectively. For the thoracic region, the average mean doses to the lung, heart, and spinal cord were 6.6 ({+-} 0.05) cGy, 6.9 ({+-} 1.2) cGy, and 4.7 ({+-} 0.8) cGy, respectively. For the pelvic region, the average mean dose to the femoral heads was 6.4 ({+-} 1.1) cGy. The MV-CBCT doses were linearly associated with the total MU but weakly dependent on patients' BMIs. Daily MV-CBCT has a cumulative effect on the total body dose and critical organs, which should be carefully considered for clinical impacts.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry

Purpose: Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (MOSFET) solid-state dosimeters have been placed to enable organ dose measurements. Here a statistical framework is established to determine the sample size (number of scans) needed for estimating ED to a desired precision and confidence, for a particular scanner and scan protocol, subject to practical limitations. Methods: The statistical scheme involves solving equations which minimize the sample size required for estimating ED to desired precision and confidence. It is subject to a constrained variation of the estimated ED and solved using the Lagrange multiplier method. The scheme incorporates measurement variation introduced both by MOSFET calibration, and by variation in MOSFET readings between repeated CT scans. Sample size requirements are illustrated on cardiac, chest, and abdomen–pelvis CT scans performed on a 320-row scanner and chest CT performed on a 16-row scanner. Results: Sample sizes for estimating ED vary considerably between scanners and protocols. Sample size increases as the required precision or confidence is higher and also as the anticipated ED is lower. For example, for a helical chest protocol, for 95% confidence and 5% precision for the ED, 30 measurements are required on the 320-row scanner and 11 on the 16-row scanner when the anticipated ED is 4 mSv; these sample sizes are 5 and 2, respectively, when the anticipated ED is 10 mSv. Conclusions: Applying the suggested scheme, it was found that even at modest sample sizes, it is feasible to estimate ED with high precision and a high degree of confidence. As CT technology develops enabling ED to be lowered, more MOSFET measurements are needed to estimate ED with the same precision and confidence.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of On-Board kV Cone Beam Computed Tomography–Based Dose Calculation With Deformable Image Registration Using Hounsfield Unit Modifications

Purpose: The purpose of this study was to estimate the accuracy of the dose calculation of On-Board Imager (Varian, Palo Alto, CA) cone beam computed tomography (CBCT) with deformable image registration (DIR), using the multilevel-threshold (MLT) algorithm and histogram matching (HM) algorithm in pelvic radiation therapy. Methods and Materials: One pelvis phantom and 10 patients with prostate cancer treated with intensity modulated radiation therapy were studied. To minimize the effect of organ deformation and different Hounsfield unit values between planning CT (PCT) and CBCT, we modified CBCT (mCBCT) with DIR by using the MLT (mCBCT{sub MLT}) and HM (mCBCT{sub HM}) algorithms. To evaluate the accuracy of the dose calculation, we compared dose differences in dosimetric parameters (mean dose [D{sub mean}], minimum dose [D{sub min}], and maximum dose [D{sub max}]) for planning target volume, rectum, and bladder between PCT (reference) and CBCTs or mCBCTs. Furthermore, we investigated the effect of organ deformation compared with DIR and rigid registration (RR). We determined whether dose differences between PCT and mCBCTs were significantly lower than in CBCT by using Student t test. Results: For patients, the average dose differences in all dosimetric parameters of CBCT with DIR were smaller than those of CBCT with RR (eg, rectum; 0.54% for DIR vs 1.24% for RR). For the mCBCTs with DIR, the average dose differences in all dosimetric parameters were less than 1.0%. Conclusions: We evaluated the accuracy of the dose calculation in CBCT, mCBCT{sub MLT}, and mCBCT{sub HM} with DIR for 10 patients. The results showed that dose differences in D{sub mean}, D{sub min}, and D{sub max} in mCBCTs were within 1%, which were significantly better than those in CBCT, especially for the rectum (P<.05). Our results indicate that the mCBCT{sub MLT} and mCBCT{sub HM} can be useful for improving the dose calculation for adaptive radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bimodal Visualization of Industrial X-Ray and Neutron Computed Tomography Data

Advanced manufacturing creates increasingly complex objects with material compositions that are often difficult to characterize by a single modality. Our collaborating domain scientists are going beyond traditional methods by employing both X-ray and neutron computed tomography to obtain complementary representations expected to better resolve material boundaries. However, the use of two modalities creates its own challenges for visualization, requiring either complex adjustments of bimodal transfer functions or the need for multiple views. Together with experts in nondestructive evaluation, we designed a novel interactive bimodal visualization approach to create a combined view of the co-registered X-ray and neutron acquisitions of industrial objects. Using an automatic topological segmentation of the bivariate histogram of X-ray and neutron values as a starting point, the system provides a simple yet effective interface to easily create, explore, and adjust a bimodal visualization. Here, we propose a widget with simple brushing interactions that enables the user to quickly correct the segmented histogram results. Our semiautomated system enables domain experts to intuitively explore large bimodal datasets without the need for either advanced segmentation algorithms or knowledge of visualization techniques. We demonstrate our approach using synthetic examples, industrial phantom objects created to stress bimodal scanning techniques, and real-world objects, and we discuss expert feedback.

image segmentation↗

SU-F-I-03: Correction of Intra-Fractional Set-Up Errors and Target Coverage Based On Cone-Beam Computed Tomography for Cervical Cancer Patients

Purpose: The purpose of this study is to investigate the patient set-up error and interfraction target coverage in cervical cancer using image-guided adaptive radiotherapy (IGART) with cone-beam computed tomography (CBCT). Methods: Twenty cervical cancer patients undergoing intensity modulated radiotherapy (IMRT) were randomly selected. All patients were matched to the isocenter using laser with the skin markers. Three dimensional CBCT projections were acquired by the Varian Truebeam treatment system. Set-up errors were evaluated by radiation oncologists, after CBCT correction. The clinical target volume (CTV) was delineated on each CBCT, and the planning target volume (PTV) coverage of each CBCT-CTVs was analyzed. Results: A total of 152 CBCT scans were acquired from twenty cervical cancer patients, the mean set-up errors in the longitudinal, vertical, and lateral direction were 3.57, 2.74 and 2.5mm respectively, without CBCT corrections. After corrections, these were decreased to 1.83, 1.44 and 0.97mm. For the target coverage, CBCT-CTV coverage without CBCT correction was 94% (143/152), and 98% (149/152) with correction. Conclusion: Use of CBCT verfication to measure patient setup errors could be applied to improve the treatment accuracy. In addition, the set-up error corrections significantly improve the CTV coverage for cervical cancer patients.

60 APPLIED LIFE SCIENCES↗

In situ Visible Light and Thermal Imaging Data from a Laser Powder Bed Fusion Additive Manufacturing Process Co-Registered to X-ray Computed Tomography and Fatigue Data

This dataset is comprised of in situ sensing data collected during a laser-based powder bed fusion additive manufacturing process, as well as rasterized scan path information, post-build X-ray computed tomography (XCT), and fatigue test results. A total of 64 cylinders, approximately 15 mm in diameter and 102 mm tall, were printed out of stainless steel 316H on a Colibrium Additive Concept Laser M2 Series 5 machine. Parameters known to produce dense material were used to construct 56 of these cylinders, while the remaining 8 cylinders were printed with relatively high energy density parameters prone to producing keyhole pores. In addition, two spatter generation blocks were constructed upstream of the 64 cylinders such that ejecta produced during the melting of the spatter generators were stochastically seeded onto the 64 cylinders. Based on previous experiments, these spatter particles were theorized to produce stochastic lack-of-fusion pores. During the construction of the build, high-resolution images of reflected light in the visible spectrum were captured both before and after recoating for each print layer. Additionally, temporally integrated thermal imaging in the near infrared spectrum produced integrated sum and max images on a layerwise basis. The multimodal in situ data has been co-registered to the build plate coordinate system, allowing for identification of process anomalies (e.g., spatter particles) apparent in the two sensors. Following construction of the build, the cylinders were subjected to XCT to identify internal flaws, and the resulting data have also been registered to the build plate coordinate system. Finally, 60 of the 64 cylinders were machined into fatigue coupons conforming to ASTM E466 and subsequently subjected to either high- or -low-cycle fatigue testing. The results of the fatigue tests have also been included in the dataset, and the XCT data corresponded to the approximate location of the gauge sections of the machine fatigue specimen geometry.

42 ENGINEERING↗