Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compressors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Thermal Modeling of a Novel Air-Cooled Temperature Swing Adsorption Compressor (AC-TSAC)

Contaminant removal technology, such as the Carbon Dioxide Removal Assembly (CDRA) on the International Space Station (ISS), is critical to Environmental Control and Life Support Systems (ECLSS), which enable humans to live and work in outer space. The CDRA includes an adsorbent bed, which absorbs CO 2 from the cabin air and releases it to a Sabatier reactor for water production when thermally cycled. An effective system would heat and cool the adsorbent quickly and uniformly to maximize the amount of CO 2 removed from the cabin and delivered to the Sabatier reactor. Air-Cooled Temperature Swing Adsorption Compressors (AC-TSAC) are promising for use downstream of the CDRA because they are a simple alternative to more mechanically-complex compressors, which are currently in use on the ISS. The current investigation addresses the thermal modeling of potential AC-TSAC designs. An initial thermal model was created and validated by comparing the model outputs to experimental data for the heating phase. Several design trades were conducted, including bed geometry (rectangular vs. cylindrical), bed structural material (i.e., the material that makes up the walls and shelves), and configuration of heat spreading elements within the bed. Also investigated is AC-TSAC performance sensitivity to the thermal conductivity of the adsorbent material and the heat pipes as well as the input power for heating. The results from these studies will inform the design of the next generation of the AC-TSAC, and the thermal modeling results will be further validated through testing.

Hannah S. Alpert↗

Thermal Modeling of a Compressor for CO2 Removal in the International Space Station

Contaminant removal technology, such as the Carbon Dioxide Removal Assembly (CDRA) on the International Space Station (ISS), is critical to Environmental Control and Life Support Systems (ECLSS), which enable humans to live and work in outer space. The CDRA includes an adsorbent bed, which absorbs CO2 from the cabin air and releases it to a Sabatier reactor for water production when thermally cycled. An effective system would heat and cool the adsorbent quickly and uniformly to maximize the amount of CO2 removed from the cabin and delivered to the Sabatier reactor. Air-Cooled Temperature Swing Adsorption Compressors (AC-TSAC) are promising for use downstream of the CDRA because they are a simple alternative to more mechanically-complex compressors, which are currently in use on the ISS. A thermal model of the AC-TSAC was created in COMSOL and validated by comparing the model outputs to experimental data for the heating phase of the cycle. Subsequently, several design trades and performance sensitivities were conducted, including bed geometry (rectangular vs. cylindrical), bed structural material (i.e., the material that makes up the walls and shelves), thermal conductivity of the adsorbent material and bed structural materials, and the input power for heating. The results from these studies will inform the design of the next generation of the AC-TSAC, and the thermal modeling results will be further validated through testing.

Hannah Alpert↗

Thermal Modeling of a Compressor for CO2 Removal in the International Space Station

Contaminant removal technology, such as the Carbon Dioxide Removal Assembly (CDRA) on the International Space Station (ISS), is critical to Environmental Control and Life Support Systems (ECLSS), which enable humans to live and work in outer space. The CDRA includes an adsorbent bed, which absorbs CO2 from the cabin air and releases it to a Sabatier reactor for water production when thermally cycled. An effective system would heat and cool the adsorbent quickly and uniformly to maximize the amount of CO2 removed from the cabin and delivered to the Sabatier reactor. Air-Cooled Temperature Swing Adsorption Compressors (AC-TSAC) are promising for use downstream of the CDRA because they are a simple alternative to more mechanically-complex compressors, which are currently in use on the ISS. A thermal model of the AC-TSAC was created in COMSOL and validated by comparing the model outputs to experimental data for the heating phase of the cycle. Subsequently, several design trades and performance sensitivities were conducted, including bed geometry (rectangular vs. cylindrical), bed structural material (i.e., the material that makes up the walls and shelves), thermal conductivity of the adsorbent material and bed structural materials, and the input power for heating. The results from these studies will inform the design of the next generation of the AC-TSAC, and the thermal modeling results will be further validated through testing.

Hannah Alpert↗

Characterization of the Upgraded NASA GRC Single Stage Axial Compressor and Fan Facility

In order to meet the emissions and efficiency goals established by the aviation community, next generation aircraft engines will require low pressure ratio, distortion tolerant fans. Maturation of the necessary technologies will require facilities which are capable of accurately testing the fan performance. To achieve this, the Single Stage Axial Compressor and Fan facility at NASA Glenn Research Center was upgraded. Details of the goals and upgrades undertaken were documented in the 2022 Turbo Expo paper, “Upgrades to the Single Stage Axial Compressor and Fan Facility for Low Pressure Ratio Boundary Layer Ingesting Fan Research.” The performance of the upgraded facility will be documented in this paper. This paper will review the challenges associated with testing low pressure ratio and distortion tolerant fans and briefly review the upgrades undertaken and their goals. Then the performance of the facility upgrades and the extent to which they were able to achieve the stated goals will be discussed. This includes mass flow measurements, test section temperature, pressure, flow angle at two axial locations, and turbulence levels at the inlet and test section. The paper also documents the performance of distortion generating swirl vanes and total pressure screens to achieve desired distorted conditions at the Aerodynamic Interface Plane.

BLI↗

Characterization of the Upgraded NASA GRC Single Stage Axial Compressor and Fan Facility

In order to meet the emissions and efficiency goals established by the aviation community, next generation aircraft engines will require low pressure ratio, distortion tolerant fans. Maturation of the necessary technologies will require facilities capable of accurately testing the fan performance are needed. To achieve this, the Single Stage Axial Compressor and Fan facility at NASA Glenn Research Center was upgraded. Details of the goals and upgrades undertaken were documented in the 2022 Turbo Expo paper, “Upgrades to the Single Stage Axial Compressor and Fan Facility for Low Pressure Ratio Boundary Layer Ingesting Fan Research.” The performance of the upgraded facility will be documented in this paper. This paper will review the challenges associated with testing low pressure ratio and distortion tolerant fans and briefly review the upgrades undertaken and their goals. Then the performance of the facility upgrades and the extent to which they were able to achieve the stated goals. This includes mass flow measurements, test section temperature, pressure, flow angle at two axial locations, and turbulence levels at the inlet and test section. The paper also documents the performance of distortion generating swirl vanes and total pressure screens to achieve desired distorted conditions at the Aerodynamic Interface Plane.

BLI↗

Internally-cooled compressor diaphragm

An internally-cooled diaphragm for an internally-cooled compressor is provided. The internally-cooled diaphragm may include an annular body configured to cool a process fluid flowing through a fluid pathway of the internally-cooled compressor. The annular body may define a return channel of the fluid pathway, and a cooling pathway in thermal communication with the fluid pathway. The return channel may be configured to at least partially diffuse and de-swirl the process fluid flowing therethrough, and the cooling pathway may be configured to receive a coolant to absorb heat from the process fluid flowing through the return channel.

42 ENGINEERING↗

Purging natural gas compressors

When a natural gas compressor completes its compression cycle, residual pressurized natural gas remains in the cylinders, valves, and conduits of the compressor. Gas leaks into the environment increasing greenhouse gas emissions and introducing safety concerns. The systems and methods herein provide ways for substantially reducing or eliminating leakage of natural gas to the atmosphere while the system sits idle between compression cycles.

Echter, Nicholas Paul↗

Radial Compressor Design and Off-Design for Trans-critical CO2 Operating Conditions

A multi-staged intercooled centrifugal compressor design is performed for an indirect-fired sCO2 cycle and the design point data are used to generate the performance maps using a 2D mean-line analysis code. Fluid and turbomachinery similarity laws are applied to find an appropriate surrogate ideal gas fluid to be used in the design and performance map generation codes. The performance maps are then scaled back for the sCO2 fluid case using the affinity laws. The developed methodology is validated using the experimental data for a compressor operating at similar inflow conditions.

Uysal, Selcuk Can↗

NUMERICAL PREDICTIONS OF MEAN PERFORMANCE AND DYNAMIC BEHAVIOR OF A 10 MWe SCO2 COMPRESSOR WITH TEST DATA VALIDATION

High-fidelity aerodynamic analysis has been demonstrated for mean performance and unsteady dynamics in a sCO2 compressor designed by Hanwha Power Systems Americas for a 10 MWe Concentrating Solar Power plant. Simulations were performed with CRUNCH CFD® software tool that was matured to accurately model near critical real fluid effects in sCO2. Pre-test predictions for mean performance were validated with test data collected later. Performance predictions were accurate and captured sensitivity of the efficiency to inlet temperature of CO2 as well as steep drop-off at high flow rates due to condensation in the inlet throat. Detailed analysis was performed to understand the source of these performance losses at near critical conditions. Unsteady dynamic effects in the compressor at off-design conditions were also identified and quantified. In particular a system wide “condensation surge” condition was detected at high flow coefficients that results in large amplitude pulsations with accompanying mass flow fluctuations at low frequencies and has potential to cause damage in closed loop systems.

hosangadi, ashvin↗

Free piston linear motor compressor and associated systems of operation

A linear motor compressor including a compressor housing and a cylinder housing having a plurality of opposing compression chambers. A piston freely reciprocates within the cylinder housing using a linear electric motor. A piston position feedback control system provides adaptive current output as a function of position feedback and/or velocity feedback from the piston and/or the electric motor, to directly power and control the electric motor, wherein the piston reciprocates without assistance from a mechanical spring or other equivalent centering force.

Stair, Jason↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Experimental Investigation of a 16-inch Impulse-type Supersonic-compressor Rotor

Performance data and characteristics of a 16-inch impulse-type supersonic-compressor rotor are presented. The experimental portion of this investigation was conducted in Freon-12. A peak pressure ratio of 3.6 was obtained with an adiabatic efficiency of 0.80 at design conditions. Performance was continuous from impulse operation, at open throttle, to shock-in-rotor operation at the stall condition.

COMPRESSOR FLOW THEORY AND EXPERIMENT↗

Clean Energy Integration in Natural Gas Compressor Station Operations

Integrating renewable energy into oil and gas operations could reduce emissions and maximize higher-value use of produced hydrocarbons. In this study, analysts from the Joint Institute for Strategic Energy Analysis (JISEA) and the National Renewable Energy Laboratory (NREL) evaluated clean power technologies for a natural gas compressor station in Texas, using NREL’s REopt tool. Different configurations of distributed energy resources were evaluated based on the technologies available and the load they can satisfy, available land, and hypothetical carbon pricing. The analysis is part of a collaborative program with industry to understand site-specific energy consumption and prices in the oil and gas supply chain and determine under what conditions clean energy options are economically attractive. This work was sponsored by a consortium including Kinder Morgan, Interstate Natural Gas Association of America Foundation, Extraction Oil & Gas, Baker Hughes, and ConocoPhillips.

03 NATURAL GAS↗