Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “component isolation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

The density of apical cells of dark-grown protonemata of the moss Ceratodon purpureus

Determinations of plant or algal cell density (cell mass divided by volume) have rarely accounted for the extracellular matrix or shrinkage during isolation. Three techniques were used to indirectly estimate the density of intact apical cells from protonemata of the moss Ceratodon purpureus. First, the volume fraction of each cell component was determined by stereology, and published values for component density were used to extrapolate to the entire cell. Second, protonemal tips were immersed in bovine serum albumin solutions of different densities, and then the equilibrium density was corrected for the mass of the cell wall. Third, apical cell protoplasts were centrifuged in low-osmolarity gradients, and values were corrected for shrinkage during protoplast isolation. Values from centrifugation (1.004 to 1.015 g/cm3) were considerably lower than from other methods (1.046 to 1.085 g/cm3). This work appears to provide the first corrected estimates of the density of any plant cell. It also documents a method for the isolation of protoplasts specifically from apical cells of protonemal filaments.

NASA Discipline Plant Biology↗

Passive Isolators for use on the International Space Station

The value of the International Space Station (ISS) as a premier microgravity environment is currently at risk due to structure-borne vibration. The vibration sources are varied and include crew activities such as exercising or simply moving from module to module, and electro- mechanical equipment such as fans and pumps. Given such potential degradation of usable microgravity, anything that can be done to dampen vibration on-orbit will significantly benefit microgravity users. Most vibration isolation schemes, both active and passive, have proven to be expensive - both operationally and from the cost of integrating isolation systems into primary/secondary structural interfaces (e.g., the ISS module/rack interface). Recently, passively absorptive materials have been tested at the bolt interfaces between the operating equipment and support structure (secondary/tertiary structural interfaces). The results indicate that these materials may prove cost-effective in mitigating the vibrational problems of the ISS. We report herein tests of passive absorbers placed at the interface of a vibration-inducing component: the Development Distillation Assembly, a subassembly of the Urine Processing Assembly, which is a rotating centrifuge and cylinder assembly attached to a mounting plate. Passive isolators were installed between this mounting plate and its support shelf. Three materials were tested: BISCO HT-800, Sorbothane 30 and Sorbothane 50, plus a control test with a hard shim. In addition, four distinct combinations of the HT-800 and Sorbothane 50 were tested. Results show a significant (three orders of magnitude) reduction of transmitted energy, as measured in power spectral density (PSD), using the isolation materials. It is noted, however, that passive materials cannot prevent the transmission of very strong forces or absorb the total energy induced from structural resonances.

Houston, Janice↗

Recurrent isolation of hydrogen peroxide-resistant spores of Bacillus pumilus from a spacecraft assembly facility

While the microbial diversity of a spacecraft assembly facility at the Jet Propulsion Laboratory (Pasadena, CA) was being monitored, H2O2-resistant bacterial strains were repeatedly isolated from various surface locations. H2O2 is a possible sterilant for spacecraft hardware because it is a low-temperature process and compatible with various modern-day spacecraft materials, electronics, and components. Both conventional biochemical testing and molecular analyses identified these strains as Bacillus pumilus. This Bacillus species was found in both unclassified (entrance floors, anteroom, and air-lock) and classified (floors, cabinet tops, and air) locations. Both vegetative cells and spores of several B. pumilus isolates were exposed to 5% liquid H2O2 for 60 min. Spores of each strain exhibited higher resistance than their respective vegetative cells to liquid H2O2. Results indicate that the H2O2 resistance observed in both vegetative cells and spores is strain-specific, as certain B. pumilus strains were two to three times more resistant than a standard Bacillus subtilis dosimetry strain. An example of this trend was observed when the type strain of B. pumilus, ATCC 7061, proved sensitive, whereas several environmental strains exhibited varying degrees of resistance, to H2O2. Repeated isolation of H2O2-resistant strains of B. pumilus in a clean-room is a concern because their persistence might potentially compromise life-detection missions, which have very strict cleanliness and sterility requirements for spacecraft hardware.

Spacecraft↗

Panel Session 25: DOE Waste Isolation Pilot Plant (WIPP) Update 2020

This panel focused on the WIPP operational efficiencies and capital improvement progress in the year 2020. Because WIPP is a key component of the US DOE EM cleanup strategy, the progress on returning WIPP to full design capacity and throughput by 2021 is of importance. Panelists with presentations: Status of WIPP Capital Asset Projects (Stephen Smith); WIPP Update (Sean Dunagan); CBFO Update (Greg Sosson)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conductive trace interconnection tape

A conductive trace interconnect tape for use with a printed circuit board or a flexible circuit substrate comprises a top insulating layer, an electrically conductive layer, and a bottom insulating layer. The top insulating layer is formed from electrically insulating material and is configured to provide electrical isolation from electrically conductive objects that are positioned on top of the conductive trace interconnect tape. The electrically conductive layer is positioned underneath the top insulating layer. The electrically conductive layer is formed from electrically conductive material and includes electrical interconnect traces, electrical component pads, or electrically conductive planar portions. The bottom insulating layer is positioned underneath the electrically conductive layer. The bottom insulating layer is formed from electrically insulating material and is configured to provide electrical isolation from electrically conductive objects that are positioned on the printed circuit board or flexible circuit substrate.

Hatch, Stephen McGarry↗

Conductive trace interconnection tape

A conductive trace interconnect tape for use with a printed circuit board or a flexible circuit substrate comprises a top insulating layer, an electrically conductive layer, and a bottom insulating layer. The top insulating layer is formed from electrically insulating material and is configured to provide electrical isolation from electrically conductive objects that are positioned on top of the conductive trace interconnect tape. The electrically conductive layer is positioned underneath the top insulating layer. The electrically conductive layer is formed from electrically conductive material and includes electrical interconnect traces, electrical component pads, or electrically conductive planar portions. The bottom insulating layer is positioned underneath the electrically conductive layer. The bottom insulating layer is formed from electrically insulating material and is configured to provide electrical isolation from electrically conductive objects that are positioned on the printed circuit board or flexible circuit substrate.

Hatch, Stephen McGarry↗

Electrochemical Imaging of Precisely‐Defined Redox and Reactive Interfaces

Abstract Understanding the diverse electrochemical reactions occurring at electrode‐electrolyte interfaces (EEIs) is a critical challenge to developing more efficient energy conversion and storage technologies. Establishing a predictive molecular‐level understanding of solid electrolyte interphases (SEIs) is challenging due to the presence of multiple intertwined chemical and electrochemical processes occurring at battery electrodes. Similarly, chemical conversions in reactive electrochemical systems are often influenced by the heterogeneous distribution of active sites, surface defects, and catalyst particle sizes. In this mini review, we highlight an emerging field of interfacial science that isolates the impact of specific chemical species by preparing precisely‐defined EEIs and visualizing the reactivity of their individual components using single‐entity characterization techniques. We highlight the broad applicability and versatility of these methods, along with current state‐of‐the‐art instrumentation and future opportunities for these approaches to address key scientific challenges related to batteries, chemical separations, and fuel cells. We establish that controlled preparation of well‐defined electrodes combined with single entity characterization will be crucial to filling key knowledge gaps and advancing the theories used to describe and predict chemical and physical processes occurring at EEIs and accelerating new materials discovery for energy applications.

Edgecomb, Joseph↗

Electrochemical Imaging of Precisely‐Defined Redox and Reactive Interfaces

Abstract Understanding the diverse electrochemical reactions occurring at electrode‐electrolyte interfaces (EEIs) is a critical challenge to developing more efficient energy conversion and storage technologies. Establishing a predictive molecular‐level understanding of solid electrolyte interphases (SEIs) is challenging due to the presence of multiple intertwined chemical and electrochemical processes occurring at battery electrodes. Similarly, chemical conversions in reactive electrochemical systems are often influenced by the heterogeneous distribution of active sites, surface defects, and catalyst particle sizes. In this mini review, we highlight an emerging field of interfacial science that isolates the impact of specific chemical species by preparing precisely‐defined EEIs and visualizing the reactivity of their individual components using single‐entity characterization techniques. We highlight the broad applicability and versatility of these methods, along with current state‐of‐the‐art instrumentation and future opportunities for these approaches to address key scientific challenges related to batteries, chemical separations, and fuel cells. We establish that controlled preparation of well‐defined electrodes combined with single entity characterization will be crucial to filling key knowledge gaps and advancing the theories used to describe and predict chemical and physical processes occurring at EEIs and accelerating new materials discovery for energy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Miniaturized integrated spectrometer using a silicon ring-grating design

We introduce and experimentally demonstrate a miniaturized integrated spectrometer operating over a broad bandwidth in the short-wavelength infrared (SWIR) spectrum that combines an add-drop ring resonator narrow band filter with a distributed Bragg reflector (DBR) based broadband filter realized in a silicon photonic platform. The contra-directional coupling DBR filter in this design consists of a pair of waveguide sidewall gratings that act as a broadband filter (i.e., 3.9 nm). The re-directed beam is then fed into the ring resonator which functions as a narrowband filter (i.e., 0.121 nm). In this scheme the free spectral range (FSR) limitation of the ring resonator is overcome by using the DBR as a filter to isolate a single ring resonance line. The overall design of the spectrometer is further simplified by simultaneously tuning both components through the thermo-optic effect. Moreover, several ring-grating spectrometer cells with different central wavelengths can be stacked in cascade in order to cover a broader spectrum bandwidth. This can be done by centering each unit cell on a different center wavelength such that the maximum range of one-unit cell corresponds to the minimum range of the next unit cell. This configuration enables high spectral resolution over a large spectral bandwidth and high extinction ratio (ER), making it suitable for a wide variety of applications.

42 ENGINEERING↗

Space manufacturing of surface acoustic wave devices, appendix D

Space manufacturing of transducers in a vibration free environment is discussed. Fabrication of the masks, and possible manufacturing of the surface acoustic wave components aboard a space laboratory would avoid the inherent ground vibrations and the frequency limitation imposed by a seismic isolator pad. The manufacturing vibration requirements are identified. The concepts of space manufacturing are analyzed. A development program for manufacturing transducers is recommended.

Sardella, G.↗

Analysis of test data on the simplex strapdown navigation system

The results of a study of test data taken on the simplex strapdown navigation system were presented. That system consisted of the following components: strapdown platform, altimeter, digital computer, tape recorder, typewriter, and power source. The objective of these tests was to isolate error sources which may cause degradation of the system's accuracy and to recommend appropriate changes to the system test procedures or computer software. The following recommendations were made: (1) addition of a gyro compassing alignment program into the navigation program, (2) addition of line drivers at the signal processor end of the transmission line, (3) need for extensive laboratory testing to determine sensor misalignments, biases, and scale factors, (4) need to stabilize the power source to prevent transients during power transfer, (5) need to isolate and eliminate the source of the large noise inputs.

Source record↗

The large-scale ionospheric electric field - Its variation with magnetic activity and relation to terrestrial kilometric radiation

Four days of simultaneous auroral zone electric field measurements on balloons flown from six sites spanning 180 deg of magnetic longitude have been analyzed. The average electric field behavior during this magnetically quiet epoch is consistent with earlier single-point measurements, although the average auroral zone electric field was more affected by corotation effects than it was during more disturbed times. When these data, which primarily reflect the large-scale (several hundred kilometer) ionospheric electric field, are mapped to the equator, a steady dawn to dusk component is apparent only on the average, while instantaneously the field is quite variable. The ionospheric electric field during isolated substorms is shown to have differing signatures east and west of 2200 LT. A worldwide positive correlation is shown to exist between the auroral zone electric field strength and the intensity of terrestrial kilometric radiation.

Holzworth, R. H.↗

A specific radioimmunoassay for osteocalcin with advantageous species crossreactivity

The specificities of immunoassays to rat and bovine osteocalcin are examined. Extracts of noncalcified tissues and tissue fractions are unreactive to the antibody, with the exception of the kidney, in which the reactive component appears to be identical with osteocalcin by gel filtration and dose dilution analysis. The assays, developed against protein isolated from bone, are also demonstrated to be reactive to the native protein (bone in situ) and to osteocalcin in serum. The assays are sensitive to less than 50 pg osteocalcin. Intra- and interassay coefficients of variation are less than 6.8%. The bovine antibody crossreacts with human, horse, monkey, baboon, and cat osteocalcin, while the rat antibody crossreacts with dog and mouse.

Patterson-Allen, P.↗

Investigation of forest canopy temperatures recorded by the thermal infrared multispectral scanner at H. J. Andrews Experimental Forest

Thermal Infrared Multispectral Scanner (TIMS) data were collected over the H. J. Andrews Experimental Forest in Western Oregon on July 29, 1983 at approximately 1:30 p.m., Pacific Standard Time. The relation of changes in canopy temperature to green leaf biomass levels in reforested clearcuts and old-growth forest was investigated. A digital data base was generated in order to isolate that portion of the thermal emission that could be attributed to surface properties other than the vegetation biomass component. The TIMS appears to be capable of detecting subtle differences in ERT as related to canopy closure and green lead biomass, however calibration techniques are needed to correct for emissivity and atmospheric effects.

Sader, Steven A.↗

Computation of aircraft component flow fields at transonic Mach numbers using a three-dimensional Navier-Stokes algorithm

A computer analysis was developed for calculating steady (or unsteady) three-dimensional aircraft component flow fields. This algorithm, called ENS3D, can compute the flow field for the following configurations: diffuser duct/thrust nozzle, isolated wing, isolated fuselage, wing/fuselage with or without integrated inlet and exhaust, nacelle/inlet, nacelle (fuselage) afterbody/exhaust jet, complete transport engine installation, and multicomponent configurations using zonal grid generation technique. Solutions can be obtained for subsonic, transonic, or hypersonic freestream speeds. The algorithm can solve either the Euler equations for inviscid flow, the thin shear layer Navier-Stokes equations for viscous flow, or the full Navier-Stokes equations for viscous flow. The flow field solution is determined on a body-fitted computational grid. A fully-implicit alternating direction implicit method is employed for the solution of the finite difference equations. For viscous computations, either a two layer eddy-viscosity turbulence model or the k-epsilon two equation transport model can be used to achieve mathematical closure.

Shrewsbury, George D.↗

An architecture for the development of real-time fault diagnosis systems using model-based reasoning

Presented here is an architecture for implementing real-time telemetry based diagnostic systems using model-based reasoning. First, we describe Paragon, a knowledge acquisition tool for offline entry and validation of physical system models. Paragon provides domain experts with a structured editing capability to capture the physical component's structure, behavior, and causal relationships. We next describe the architecture of the run time diagnostic system. The diagnostic system, written entirely in Ada, uses the behavioral model developed offline by Paragon to simulate expected component states as reflected in the telemetry stream. The diagnostic algorithm traces causal relationships contained within the model to isolate system faults. Since the diagnostic process relies exclusively on the behavioral model and is implemented without the use of heuristic rules, it can be used to isolate unpredicted faults in a wide variety of systems. Finally, we discuss the implementation of a prototype system constructed using this technique for diagnosing faults in a science instrument. The prototype demonstrates the use of model-based reasoning to develop maintainable systems with greater diagnostic capabilities at a lower cost.

Hall, Gardiner A.↗

Long-Lived Linear-Motion Suspension For Cryogenic Instrument

Mechanism suspends optical component in cryogenic instrument in such way to allow component to translate smoothly along one axis, without vibration. Bearings located outside cooled instrument chamber for longer life. Thermal isolators separate bearings from cryogenic environment inside instrument chamber.

Packard, Douglas T.↗

Pointing Control System Design and Performance Evaluation for TPF Coronagraph

The Terrestrial Planet Finder (TPF) program aims to detect and characterize extra-solar Earth-like planets. The coronagraph telescope is one of the four mission concepts being studied. In order to reject the star flux and detect the planet flux in the visible light range, the coronagraph telescope must achieve a rejection ratio on the order of a billion to one. Dynamic jitter, introduced by environmental and on-board mechanical disturbances, degrades the optical performance, as characterized primarily by contrast ratio. The feasibility of using passive vibration isolation combined with active attitude and line-of- sight control systems to stabilize the spacecraft and the optical components to the requisite level is being studied. The telescope is also required to slew between targets. The slew mode control law must be designed to balance the need for efficient large-angle maneuvers while simultaneously avoiding the excitation of flexible modes in order to minimize settling time.

Liu, Kuo-Chia↗