Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “central receiver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

AMiBA: cluster Sunyaev-Zel'dovich effect observations with the expanded 13-element array

The Yuan-Tseh Lee Array for Microwave Background Anisotropy (AMiBA) is a co-planar interferometer array operating at a wavelength of 3 mm to measure the Sunyaev–Zel’dovich effect (SZE) of galaxy clusters at arcminute scales. The first phase of operation—with a compact 7-element array with 0.6 m antennas (AMiBA-7)—observed six clusters at angular scales from 5{sup ′} to 23{sup ′}. Here, we describe the expansion of AMiBA to a 13-element array with 1.2 m antennas (AMiBA-13), its subsequent commissioning, and cluster SZE observing program. The most noticeable changes compared to AMiBA-7 are (1) array re-configuration with baselines ranging from 1.4 m to 4.8 m, allowing us to sample structures between 2{sup ′} and 10{sup ′}, (2) 13 new lightweight carbon-fiber-reinforced plastic (CFRP) 1.2 m reflectors, and (3) additional correlators and six new receivers. Since the reflectors are co-mounted on and distributed over the entire six-meter CFRP platform, a refined hexapod pointing error model and phase error correction scheme have been developed for AMiBA-13. These effects—entirely negligible for the earlier central close-packed AMiBA-7 configuration—can lead to additional geometrical delays during observations. Our correction scheme recovers at least 80 ± 5% of the point-source fluxes. We, therefore, apply an upward correcting factor of 1.25 to our visibilities to correct for phase decoherence, and a ±5% systematic uncertainty is added in quadrature with our statistical errors. We demonstrate the absence of further systematics with a noise level consistent with zero in stacked uv-visibilities. From the AMiBA-13 SZE observing program, we present here maps of a subset of 12 clusters with signal-to-noise ratios above five. We demonstrate combining AMiBA-7 with AMiBA-13 observations on Abell 1689, by jointly fitting their data to a generalized Navarro–Frenk–White model. Our cylindrically integrated Compton-y values for five radii are consistent with results from the Berkeley-Illinois-Maryland Array, the Owens Valley Radio Observatory, the Sunyaev–Zel’dovich Array, and the Planck Observatory. We also report the first targeted SZE detection toward the optically selected cluster RCS J1447+0828, and we demonstrate the ability of AMiBA SZE data to serve as a proxy for the total cluster mass. Finally, we show that our AMiBA-SZE derived cluster masses are consistent with recent lensing mass measurements in the literature.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimation of neutral wind velocity in the ionospheric heights by HF-Doppler technique

Three net stations located about 100 kilometers apart were set up around the station of the standard frequency and time signals (JJY) in central Japan and measurements of atmospheric gravity waves in the ionospheric heights (F-region, 200 to 400 km) were made by means of the HF-Doppler technique during the period of February 1983 to December 1983. The frequencies of the signals received are 5.0, 8.0 and 10.0 MHz, but only the 8.0 MHz signals are used for the present study, because no ambiguities due to the interference among other stations such as BPM, BSF, etc. exist by the use of 8.0 MHz. Two main results concerning the horizontal phase velocity of the atmospheric gravity waves with periods of 40 to 70 min may be summarized as follows: (1) the value of the phase velocity ranges from 50 m/s to 300 m/s; (2) the direction of the gravity wave propagation shows a definite seasonal variation. The prevailing direction of the gravity waves in winter is from north to south, which is consistent with the results obtained from other investigations. On the other hand, the two directions, from northeast to southwest and from southeast to northeast, dominate in summer.

Kitamura, T.↗

Space Radiation

Astronauts receive the highest occupational radiation exposure. Effective protections are needed to ensure the safety of astronauts on long duration space missions. Increased cancer morbidity or mortality risk in astronauts may be caused by occupational radiation exposure. Acute and late radiation damage to the central nervous system (CNS) may lead to changes in motor function and behavior, or neurological disorders. Radiation exposure may result in degenerative tissue diseases (non-cancer or non-CNS) such as cardiac, circulatory, or digestive diseases, as well as cataracts. Acute radiation syndromes may occur due to occupational radiation exposure.

Wu, Honglu↗

Final Results of a Prospective Study Comparing the Local Control of Short-Course and Long-Course Radiotherapy for Metastatic Spinal Cord Compression

Purpose: Many patients with metastatic spinal cord compression (MSCC) live long enough to develop a recurrence in the irradiated spinal area. This is the first prospective study that has compared local control of different radiotherapy schedules for MSCC. Methods and Materials: A total of 265 patients treated with radiotherapy alone were included in this prospective nonrandomized study. The primary goal was to compare local control from short-course (1 x 8 Gy/5 x 4 Gy, n = 131) and long-course radiotherapy (10 x 3 Gy/15 x 2.5 Gy/20 x 2 Gy, n = 134). Secondary end points were motor function and survival. The analysis of local control (no MSCC recurrence in the irradiated spinal area) included the 224 patients with improvement or no change of motor deficits during radiotherapy. Eleven additional factors were evaluated for outcomes. Results: One-year local control was 61% after short-course and 81% after long-course radiotherapy (p = 0.005). On multivariate analysis (MVA), improved local control was associated with long-course radiotherapy (p = 0.018). Motor function improved in 37% after short-course and 39% after long-course radiotherapy (p = 0.95). Improved motor function was associated with better performance status (p = 0.015), favorable tumor type (p = 0.034), and slower development of motor deficits (p < 0.001). One-year survival rates were 23% after short-course and 30% after long-course radiotherapy (p = 0.28). On MVA, improved survival was associated with better performance status (p < 0.001), no visceral metastases (p < 0.001), involvement of only one to three vertebrae (p = 0.040), ambulatory status (p = 0.038), and bisphosphonate administration after radiotherapy (p < 0.001). Conclusions: Long-course radiotherapy was associated with better local control, similar functional outcome, and similar survival compared to short-course radiotherapy. Patients with a relatively favorable expected survival should receive long-course radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Size-dependent effects of nanoparticles on the activity of cytochrome P450 isoenzymes

Nanoparticles are known to be able to interfere with cellular metabolism and to cause cytotoxicity and moreover may interfere with specific cellular functions. Serious effects on the latter include changes in liver cell function. The cytochrome P450 system is expressed in many cells but is especially important in hepatocytes and hormone-producing cells. The interaction of polystyrene nanoparticles with the most important drug-metabolizing cytochrome P450 isoenzymes, CYP3A4, CYP2D6, CYP2C9 and CYP2A1 expressed individually in insect cells (BACULOSOMES) was studied by the cleavage of substrates coupled to a fluorescent dye. The data obtained for individual isoenzymes were compared to metabolism in microsomes isolated from normal liver and from the hepatoma cell line H4-II-E-C3. Small (20-60 nm) carboxyl polystyrene particles but not larger (200 nm) ones reached high intracellular concentrations in the vicinity of the endoplasmic reticulum. These small particles inhibited the enzymatic activity of CYP450 isoenzymes in BACULOSOMES and substrate cleavage in normal liver microsomes. They moreover increased the effect of known inhibitors of the cytochrome P450 system (cimetidine, phenobarbital and paclitaxel). Substrate cleavage by the hepatoma cell line H4-II-E-C3 in contrast was undetectable, making this cell line unsuitable for this type of study. Our results thus demonstrate that nanoparticles can inhibit the metabolism of xenobiotics by the CYP450 system in model systems in vitro. Such inhibition could also potentially occur in vivo and possibly cause adverse effects in persons receiving medication.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Verifying the Computational Integrity of Power Grid Controls with Zero-Knowledge Proof

The control of future power grids is migrating from a centralized to a distributed/decentralized scheme to enable a massive penetration of distributed energy resources with rising dependence on communication infrastructure. A common assumption made for most existing distributed/decentralized controllers is that local controllers would faithfully follow the designated controller dynamics based on the data received from communication channels. However, with increased probability of cyberattacks on Operational Technology infrastructure, such an assumption could be risky because proper execution of the controller dynamics is then built on trust in secure communication and computation. In this work, we leverage a cryptography technology known as zero-knowledge scalable transparent arguments of knowledge (zk-STARK) to verify the computational integrity of power grid control algorithms, with projected linear dynamics-based control schemes as the initial proof-of-concept test case. The method presented here converts the cybersecurity challenge of data integrity for grid control into a subset of computational integrity.

computational integrity↗

SU-E-T-162: Evaluation of Dose Calculation of RayStation Planning System in Heterogeneous Media

Purpose: To investigate the clinical reliability of heterogeneity-based dose algorithm using RayStation treatment planning system v.4.0. Methods: The collapsed cone dose calculations in RayStation (RaySearch, Sweden) were compared with the measurements (ion chamber and EBT2 film) and with an in-house Monte Carlo algorithm. A heterogeneous multi-layer phantom and CT images of 4 lung cancer patients were used here. The phantom, composed of multiple solid water slabs and Styrofoams, was irradiated with 6MV beams perpendicular to the layers. The MLC-defined field sizes were 5×5, 10×10, 15×15 and 20×20cm{sup 2}. The chamber was positioned at center of central solid water layer, and the films were placed at interfaces of solid water and Styrofoam. The RayStation dose and Monte Carlo dose were compared by performing absolute gamma analysis (3mm/3%): 1D gamma for PDD in the phantom and 3D gamma for patient volumes receiving dose above 10% of maximum dose. Results: The point dose differences between RayStation and ion chamber measurement were smaller than 1% for all of the field sizes. Between RayStation and film measurement, 5×5cm2 field had the maximum differences : <4mm for the penumbra and <0.3mm for the field width at all Styrofoam-and-solid-water interfaces. The absolute gamma analysis showed good agreement between RayStation and Monte Carlo. For PDD along beam axis in the phantom, the 1D gamma was 95.4, 98.6, 99.6 and 99.3% for field size 5×5, 10×10, 15×15 and 20×202 respectively. For dose comparison using patient CT images, 3D gamma was > 95% for all the patients. Conclusion: With respect to ion chamber/film measurement and Monte Carlo calculation, the collapsed cone algorithm in RayStation computed reasonable dose in both phantom and patient cases. Heterogeneity-based dose calculation of RayStation is clinically acceptable in heterogeneous media.

60 APPLIED LIFE SCIENCES↗

SU-F-T-501: Dosimetric Comparison of Single Arc-Per-Beam and Two Arc-Per-Beam VMAT Optimization in the Monaco Treatment Planning System

Purpose: The purpose of this study was to evaluate the dosimetric and practical effects of the Monaco treatment planning system “max arcs-per-beam” optimization parameter in pelvic radiotherapy treatments. Methods: A total of 17 previously treated patients were selected for this study with a range of pelvic disease site including prostate(9), bladder(1), uterus(3), rectum(3), and cervix(1). For each patient, two plans were generated, one using a arc-per-beam setting of ‘1’ and another with setting of ‘2’. The setting allows the optimizer to add a gantry direction change, creating multiple arc passes per beam sequence. Volumes and constraints established from the initial clinical treatments were used for planning. All constraints and dose coverage objects were kept the same between plans, and all plans were normalized to 99.7% to ensure 100% of the PTV received 95% of the prescription dose. We evaluated the PTV conformity index, homogeneity index, total monitor units, number of control points, and various dose volume histogram (DVH) points for statistical comparison (alpha=0.05). Results: We found for the 10 complex shaped target volumes (small central volumes with extending bilateral ‘arms’ to cover nodal regions) that the use of 2 arcs-per-beam achieved significantly lower average DVH values for the bladder V20 (p=0.036) and rectum V30 (p=0.001) while still meeting the high dose target constraints. DVH values for the simpler, more spherical PTVs were not found significantly different. Additionally, we found a beam delivery time reduction of approximately 25%. Conclusion: In summary, the dosimetric benefit, while moderate, was improved over a 1 arc-per-beam setting for complex PTVs, and equivalent in other cases. The overall reduced delivery time suggests that the use of multiple arcs-per-beam could lead to reduced patient on table time, increased clinical throughput, and reduced medical physics quality assurance effort.

60 APPLIED LIFE SCIENCES↗

The Amazon Dense GNSS Meteorological Network: A New Approach for Examining Water Vapor and Deep Convection Interactions in the Tropics

The Amazon Dense Global Navigational Satellite System (GNSS) Meteorological Network ((ADGMN) provides high spatiotemporal resolution, all-weather precipitable water vapor for studying the evolution of continental tropical and sea-breeze convective regimes of Amazonia. The ADGMN campaign consisted of two experiments: a 6-week campaign in and around Belem, which coincided with the Cloud Processes of the Main Precipitation Systems in Brazil: A Contribution to Cloud-Resolving Modeling and to the Global Precipitation Measurement (CHUVA) and a 1-yr campaign in and around Manaus. The Belem network was composed of 15 GNSS/meteorological stations that provided high-frequency (5 min) PWV data as well as surface meteorological variables For the 6-week duration of the Belem experiment, days were categorized as convective (22 days) or nonconvective (19 days) based solely on a minimum cloud-top temperature of 240 K or below over the central portion of the network and a report of precipitation at at least one site during the afternoon or evening. Here, the Manaus network commenced in April 2011 with 12 GNSS meteorological stations. Local circulations in Manaus driven by anthropogenic deforestation have, in particular, received attention.

58 GEOSCIENCES↗

X-wing fly-by-wire vehicle management system

A complete, computer based, vehicle management system (VMS) for X-Wing aircraft using digital fly-by-wire technology controlling many subsystems and providing functions beyond the classical aircraft flight control system. The vehicle management system receives input signals from a multiplicity of sensors and provides commands to a large number of actuators controlling many subsystems. The VMS includes--segregating flight critical and mission critical factors and providing a greater level of back-up or redundancy for the former; centralizing the computation of functions utilized by several subsystems (e.g. air data, rotor speed, etc.); integrating the control of the flight control functions, the compressor control, the rotor conversion control, vibration alleviation by higher harmonic control, engine power anticipation and self-test, all in the same flight control computer (FCC) hardware units. The VMS uses equivalent redundancy techniques to attain quadruple equivalency levels; includes alternate modes of operation and recovery means to back-up any functions which fail; and uses back-up control software for software redundancy.

Fischer, Jr., William C.↗

Stabilization of Phase of a Sinusoidal Signal Transmitted Over Optical Fiber

In the process of connecting widely distributed antennas into a coherent array, it is necessary to synchronize the timing of signals at the various locations. This can be accomplished by distributing a common reference signal from a central source, usually over optical fiber. A high-frequency (RF or microwave) tone is a good choice for the reference. One difficulty is that the effective length of the optical fiber changes with temperature and mechanical stress, leading to phase instability in the received tone. This innovation provides a new way to stabilize the phase of the received tone, in spite of variations in the electrical length of the fiber. Stabilization is accomplished by two-way transmission in which part of the received signal is returned to the transmitting end over an identical fiber. The returned signal is detected and used to close an electrical servo loop whose effect is to keep constant the phase of the tone at the receiving end.

DAddario, Larry R.↗

Characterization and Oxidation Behavior of Rayon-Derived Carbon Fibers

Rayon-derived fibers are the central constituent of reinforced carbon/ carbon (RCC) composites. Optical, scanning electron, and transmission electron microscopy were used to characterize the as-fabricated fibers and the fibers after oxidation. Oxidation rates were measured with weight loss techniques in air and oxygen. The as-received fibers are approximately 10 micron in diameter and characterized by grooves or crenulations around the edges. Below 800 C, in the reaction-controlled region, preferential attack began in the crenulations and appeared to occur down fissures in the fibers.

Jacobson, Nathan↗

Carbon Monoxide in the Cold Debris of Supernova 1987A

We report spectroscopic and imaging observations of rotational transitions of cold CO and SiO in the ejecta of SN1987A, the first such emission detected in a supernova remnant. In addition to line luminosities for the CO J = 1-0, 2-1, 6-5, and 7-6 transitions, we present upper limits for all other transitions up to J = 13-12, collectively measured from the Atacama Large Millimeter Array, the Atacama Pathfinder EXperiment, and the Herschel Spectral and Photometric Imaging REceiver. Simple models show the lines are emitted from at least 0.01 M ☉ of CO at a temperature >14 K, confined within at most 35% of a spherical volume expanding at ~2000 km s-1. Moreover, we locate the emission within 1'' of the central debris. These observations, along with a partial observation of SiO, confirm the presence of cold molecular gas within supernova remnants and provide insight into the physical conditions and chemical processes in the ejecta. Furthermore, we demonstrate the powerful new window into supernova ejecta offered by submillimeter observations.

Cold↗

Spark-ignited direct-injection engine combustion systems

A direct-injection stratified charge internal combustion engine includes a combustion cylinder to receive an air-fuel mixture, and an air intake port to inlet air into the combustion cylinder. The direct-injection engine also includes a fuel injector configured to deliver fuel within the cylinder in a spray pattern substantially aligned to a cylinder central axis to create the air-fuel mixture. A spark igniter is located within a path of the spray pattern to ignite combustion of the air-fuel mixture. The direct-injection engine further includes a movable piston defining a lower boundary of the combustion cylinder to contain the combustion of the air-fuel mixture. The piston is configured to include a bowl portion having local geometric features located on an intake port side of the combustion cylinder to redirect fluid flow towards a vortex in fluid communication with a combustion location near the cylinder central axis.

42 ENGINEERING↗

Low-Dose and Limited-Volume Radiotherapy Alone for Primary Dural Marginal Zone Lymphoma: Treatment Approach and Review of Published Data

Purpose: Primary dural lymphoma is a rare intracranial lymphoma that almost always has a marginal zone histologic type and immunophenotype and often remains localized and is thus potentially curable with radiotherapy (RT) alone. The unusual location and histologic type of primary dural marginal zone lymphoma (PDMZL) distinguish it from primary central nervous system lymphoma and poses treatment dilemmas of technique, volume, and dose that have not been well addressed. We set out to analyze our recent experience in treating PDMZL and reviewed the limited published data available. Methods and Materials: Between 2002 and 2006, we treated 5 patients with localized PDMZL. Of these 5 patients, 3 had unilateral and 2 had bilateral/multifocal involvement, and 3 underwent subtotal tumor resection and 2 biopsy only. Whole brain RT was given before involved-field RT (IFRT) in 4 patients and 1 received IFRT alone. The median whole brain RT, IFRT, and total RT dose was 20, 12, and 30 Gy, respectively. The planning computed tomography scan was always fused with the post-gadolinium magnetic resonance imaging scan to assist in the IFRT volume determination. We also analyzed the published data from 27 additional patients. Results: The median follow-up was 34 months (range, 31-52). All obtained lasting local control. One patient developed a relapse in the soft tissue of the flank and additional systemic progression but no central nervous system recurrence. At last follow-up, no significant treatment-related neurotoxicity was detected. Conclusion: The results of our study have demonstrated that a combination of whole brain RT/IFRT or even low-dose IFRT alone provides excellent durable local control of PDMZL. This approach is potentially curative, possibly without significant neurotoxicity. Additional study and longer follow-up are needed to determine the appropriate RT dose and volume parameters for this rare, debilitating, and yet potentially curable lymphoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hydrothermal Liquefaction and Upgrading of Municipal Wastewater Treatment Plant Sludge: A Preliminary Techno-Economic Analysis

A preliminary process model and techno-economic analysis (TEA) was completed for fuel produced from hydrothermal liquefaction (HTL) of sludge waste from a municipal wastewater treatment plant (WWTP) and subsequent biocrude upgrading. The model is adapted from previous work by Jones et al. (2014) for algae HTL, using experimental data generated in fiscal year 2015 (FY15) bench-scale HTL testing of sludge waste streams. Testing was performed on sludge samples received from MetroVancouver’s Annacis Island WWTP (Vancouver, B.C.) as part of a collaborative project with the Water Environment and Reuse Foundation (WERF). The full set of sludge HTL testing data from this effort will be documented in a separate report to be issued by WERF. This analysis is based on limited testing data and therefore should be considered preliminary. Future refinements are necessary to improve the robustness of the model, including a cross-check of modeled biocrude components with the experimental GCMS data and investigation of equipment costs most appropriate at the smaller scales used here. Environmental sustainability metrics analysis is also needed to understand the broader impact of this technology pathway. The base case scenario for the analysis consists of 10 HTL plants, each processing 100 dry U.S. ton/day (92.4 ton/day on a dry, ash-free basis) of sludge waste and producing 234 barrel per stream day (BPSD) biocrude, feeding into a centralized biocrude upgrading facility that produces 2,020 barrel per standard day of final fuel. This scale was chosen based upon initial wastewater treatment plant data collected by the resource assessment team from the EPA’s Clean Watersheds Needs Survey database (EPA 2015a) and a rough estimate of what the potential sludge availability might be within a 100-mile radius. In addition, we received valuable feedback from the wastewater treatment industry as part of the WERF collaboration that helped form the basis for the selected HTL and upgrading plant scales and feedstock credit (current cost of disposal). It is assumed that the sludge is currently disposed of at $16.20/wet ton ($46/dry ton at 35% solids; $50/ton dry, ash-free basis) and this is included as a feedstock credit in the operating costs. The base case assumptions result in a minimum biocrude selling price of $3.8/gge and a minimum final upgraded fuel selling price of $4.9/gge. Several areas of process improvement and refinements to the analysis have the potential to significantly improve economics relative to the base case: • Optimization of HTL sludge feed solids content • Optimization of HTL biocrude yield • Optimization of HTL reactor liquid hourly space velocity (LHSV) • Optimization of fuel yield from hydrotreating • Combined large and small HTL scales specific to regions (e.g., metropolitan and suburban plants) Combined improvements believed to be achievable in these areas can potentially reduce the minimum selling price of biocrude and final upgraded fuel by about 50%. Further improvements may be possible through recovery of higher value components from the HTL aqueous phase, as being investigated under separate PNNL projects. Upgrading the biocrude at an existing petroleum refinery could also reduce the MFSP, although this option requires further testing to ensure compatibility and mitigate risks to a refinery. And finally, recycling the HTL aqueous phase product stream back to the headworks of the WWTP (with no catalytic hydrothermal gasification treatment) can significantly reduce cost. This option is uniquely appropriate for application at a water treatment facility but also requires further investigation to determine any technical and economic challenges related to the extra chemical oxygen demand (COD) associated with the recycled water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High voltage systems (tube-type microwave)/low voltage system (solid-state microwave) power distribution

SPS satellite power distribution systems are described. The reference Satellite Power System (SPS) concept utilizes high-voltage klystrons to convert the onboard satellite power from dc to RF for transmission to the ground receiving station. The solar array generates this required high voltage and the power is delivered to the klystrons through a power distribution subsystem. An array switching of solar cell submodules is used to maintain bus voltage regulation. Individual klystron dc voltage conversion is performed by centralized converters. The on-board data processing system performs the necessary switching of submodules to maintain voltage regulation. Electrical power output from the solar panels is fed via switch gears into feeder buses and then into main distribution buses to the antenna. Power also is distributed to batteries so that critical functions can be provided through solar eclipses.

Nussberger, A. A.↗

Availability of Seasat synthetic aperture radar imagery

One of the sensors of the Seasat satellite was a synthetic aperture radar (SAR), which was operated over both oceanic and land areas. The Seasat SAR was an active imaging microwave system which transmitted and received horizontally polarized radiation at L-band frequency (1.275 GHz, 23-cm wavelength). Extensive coverage was obtained over North America, Europe, the Eastern Pacific Ocean, the Western and Northern Atlantic Ocean, and the Beaufort Sea. Surface coverage was also acquired over limited portions of Central America, the Gulf of Mexico, and the Caribbean Sea. The majority of the data has been optically processed in a so-called survey mode. Each optically processed Seasat pass has a swath width of 100 km at a scale of 1:500,000. A subset of the SAR data has been digitally processed in a so-called high-resolution mode. Digital processing has been performed upon selected scenes with dimensions of 100 x 100 km. Digitally processed imagery has a nominal ground resolution of 25 m.

Holt, B.↗