PIP-II High Beta 650 Prototype Cryomodule Assembly Experience and Related Design Optimization

After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may have arisen from the transport of the cryomodule. While measurements taken at room temperature after the conclusion of shipment indicated that there were no negative impacts on cavity alignment, beamline vacuum, or cavity frequency, testing at 2K was required to validate other aspects such as tuner operation, cavity coupling, cryogenic system integrity, and cavity performance. Results of this latest round of limited 2K testing will be presented.

Ozelis, J.↗

A dosimetric comparative study: Volumetric modulated arc therapy vs intensity-modulated radiation therapy in the treatment of nasal cavity carcinomas

The purpose of this study was to evaluate the differences between volumetric modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) in the treatment of nasal cavity carcinomas. The treatment of 10 patients, who had completed IMRT treatment for resected tumors of the nasal cavity, was replanned with the Philips Pinnacle{sup 3} Version 9 treatment-planning system. The IMRT plans used a 9-beam technique whereas the VMAT (known as SmartArc) plans used a 3-arc technique. Both types of plans were optimized using Philips Pinnacle{sup 3} Direct Machine Parameter Optimization algorithm. IMRT and VMAT plans' quality was compared by evaluating the maximum, minimum, and mean doses to the target volumes and organs at risk, monitor units (MUs), and the treatment delivery time. Our results indicate that VMAT is capable of greatly reducing treatment delivery time and MUs compared with IMRT. The reduction of treatment delivery time and MUs can decrease the effects of intrafractional uncertainties that can occur because of patient movement during treatment delivery. VMAT's plans further reduce doses to critical structures that are in close proximity to the target volume.

61 RADIATION PROTECTION AND DOSIMETRY↗

Structure-based design of prefusion-stabilized human metapneumovirus fusion proteins

The human metapneumovirus (hMPV) fusion (F) protein is essential for viral entry and is a key target of neutralizing antibodies and vaccine development. The prefusion conformation is thought to be the optimal vaccine antigen, but previously described prefusion F proteins expressed poorly and were not well stabilized. Here, we use structures of hMPV F to guide the design of 42 variants containing stabilizing substitutions. Through combinatorial addition of disulfide bonds, cavity-filling substitutions, and improved electrostatic interactions, we describe a prefusion-stabilized F protein (DS-CavEs2) that expresses at 15mg/L and has a melting temperature of 71.9°C. Crystal structures of two prefusion-stabilized hMPV F variants reveal that antigenic surfaces are largely unperturbed. Importantly, immunization of mice with DS-CavEs2 elicits significantly higher neutralizing antibody titers against hMPV A1 and B1 viruses than postfusion F. The improved properties of DS-CavEs2 will advance the development of hMPV vaccines and the isolation of therapeutic antibodies.

59 BASIC BIOLOGICAL SCIENCES↗

A 15-Mev/nucleon Iso-Cyclotron for Security and Radioisotope Production

Cargo inspection systems exploit the broad bremsstrahlung spectrum from a 6-10 MeV, low-duty cycle electron accelerator which in the presence of significant backgrounds presents challenges in image and material identification. An alternative approach is to use ions which can excite nuclear states either directly, or through generation of secondary high-energy signature gammas produced from nuclear interactions in a target. RadiaBeam is designing a compact sector isocyclotron 1.25 m in radius, with high-gradient cavities to accelerate multi-ion species up to 15-20 MeV/u with large turn-to turn, centimeter-level separation for low-loss extraction without lossy foil stripping. A strong-focusing radial field profile will be optimized in a separated-sector format for control over machine tune simultaneous with isochronous orbist requirements for high-current (~0.5 milliamp) operation. Innovation in injection will be introduced to replace the high-loss central region. Non-security applications of the cyclotron include medical isotope production, ion radiobiology, as well as material science research and ion instrumentation development.

43 PARTICLE ACCELERATORS↗

Nitric Oxide PLIF Visualization of Simulated Fuel-Air Mixing in a Dual-Mode Scramjet

Nitric oxide (NO) planar induced laser fluorescence (PLIF) measurements have been performed in a small scale scramjet combustor at the University of Virginia Aerospace Research Laboratory at nominal simulated Mach 5 flight. A mixture of NO and N2 was injected at the upstream end of the inlet isolator as a surrogate for ethylene fuel, and the mixing of this fuel simulant was studied with and without a shock train. The shock train was produced by an air throttle, which simulated the blockage effects of combustion downstream of the cavity flame holder. NO PLIF signal was imaged in a plane orthogonal to the freestream at the leading edge of the cavity. Instantaneous planar images were recorded and analyzed to identify the most uniform cases, which were achieved by varying the location of the fuel injection and shock train. This method was used to screen different possible fueling configurations to provide optimized test conditions for follow-on combustion measurements using ethylene fuel. A theoretical study of the selected NO rotational transitions was performed to obtain a LIF signal that is linear with NO mole fraction and approximately independent of pressure and temperature.

Cantu, Luca M. L.↗

Recent improvements to software used for optimization of SRF linacs

This work describes a software tool that allows one to vary parameters and understand the effects on the optimized costs of construction plus 10 year operations of an SRF linac, where operation costs includes the cost of the electrical utilities but not the labor or other costs. The program includes estimates for the associated cryogenic facility, and controls hardware. The software interface provides the ability to vary the cost of the different aspects of the machine as well as to change the cryomodule and cavity types. Additionally, this work will describe the recent improvements to the software that allow one to estimate the costs of energy-recovery based linacs and to enter arbitrary values of the low field Q0 and Q0 slope. The initial goal when developing the software was to convert a spreadsheet format to a graphical interface and to allow the ability to sweep different parameter sets. The tools also allow one to compare the cost of the different facets of the machine design and operations so as to better understand tradeoffs. An example of how it was used to independently investigate cost optimization tradeoffs for the LCLS-II linac will also be presented.

Powers, Tom J.↗

Superadiabatic scheme for optimizing the fast generation of tree-type 3D entanglement

High-dimensional entanglement has more superior security than qubit entanglement. Recently, adiabatic and fast-adiabatic schemes for generating a novel three-dimensional (3D) entanglement, tree-type 3D entanglement, were proposed. However, the previous schemes have their experimental defects, respectively. Here we give a superadiabatic scheme for optimizing the generation of tree-type 3D entanglement. Adequate numerical simulations prove that the scheme is not only fast, effective and robust, but also highly feasible in experiment. - Highlights: • The scheme for generating tree-type 3D entanglement is not only fast but also robust against the variation in the control parameters and decoherence induced by atomic spontaneous emissions and photon leakages from the cavity-fiber system. • The designed driving pulses are experimentally feasible Gaussian pulses which can reduce experimental difficulties. • The Hamiltonian used to speed up generating tree-type 3D entanglement is of the same form as the original Hamiltonian, which will greatly enhances the experimental feasibility of the scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-CD-209-02: Beam Angle Optimization Incorporating Anatomical Heterogeneities for Pencil Beam Scanning Charged-Particle Therapy

Purpose: In charged particle therapy with pencil beam scanning (PBS), localization of the dose in the Bragg peak makes dose distributions sensitive to lateral tissue heterogeneities. Sensitivity of a PBS plan to lateral tissue heterogeneity can be reduced by selecting suitable beam angles. The purpose of this study is to establish a fast and accurate method of beam angle selection for PBS. Methods: The lateral tissue heterogeneity surrounding the path of respective pencil beams at a given angle was quantified with the heterogeneity number using effective density data of patients. To shorten the computation time, one dimensional dose calculation and optimization were conducted along the central axis of pencil beams originating from the scanning magnets. Calculation was performed for all fields with possible gantry and couch angles. The angles leading the minimum mean heterogeneity number was selected as the optimal beam angle. Three head and neck (H&N) cancer patients were used to evaluate our method. Dose distributions and their robustness to range and set up errors were evaluated for all tested angles, and their relation to their heterogeneity numbers were investigated. Results: Variety of heterogeneity number was clearly shown due to air cavities and bony structures in the patients. The mean value of heterogeneity number in all possible fields varied between 1.2 and 10.6 mm. By selecting a field with a lower mean value of heterogeneity number, target dose coverage and robustness of the fields were improved. Conclusion: We developed a computational method to determine a beam angle that leads good target coverage and robustness to setup errors. The developed stand-alone computation program is simple, fast, accurate and applicable for beam angle selection in PBS therapy.

60 APPLIED LIFE SCIENCES↗

Photoelectron spectroscopy and computational investigations of the electronic structures and noncovalent interactions of cyclodextrin-closo-dodecaborate anion complexes x-CD·B12X122- (x = a, ß, y; X = H, F)

We report a joint negative ion photoelectron spectroscopy (NIPES) and computational study on the electronic structures and noncovalent interactions of a series of cyclodextrin-closo-dodecaborate dianion complexes, ?-CD·B12X122- (? = a, ß, ?; X = H, F). The measured vertical / adiabatic detachment energies (VDEs / ADEs) are 1.15/0.93, 3.55/3.20, 3.90/3.60, and 3.85/3.60 eV for B12H122- and its a-, ß-, ?-CD complexes, respectively; while the corresponding values are 1.90/1.70, 4.00/3.60, 4.33/3.95, and 4.30/3.85 eV for the X = F case. These results show that the inclusion of B12X122- into the CD cavities greatly increase the electronic stability of the dianions. The effect of electronic stabilization for ß-CD is roughly the same as for ?-CD, both being considerably stronger than that for a-CD. Density functional theory (DFT) based geometry optimization reveals that B12X122- are inserted into CDs increasingly deeper from a-CD to ?-CD. The calculated VDEs and ADEs agree with the experiments well, particularly, reproducing the electron binding energy (EBE) trends. The molecular orbital analyses indicate that the most loosely bound photodetached electrons origin from the guest B12X122- moieties. In addition to a shift of all signals to larger EBE, significant changes in the signal patterns are observed. At low EBE, this is due to the splitting of highly degenerate B12X122- orbitals, while at high EBE, photodetachment from CD oxygens contributes to the new bands. The guest B12X122- and host CD nocovalent, size-specific interaction based on the independent gradient model (IGM) and energy decomposition analysis (EDA), is dominated by electrostatic interactions. The analysis further unravels unambiguiously the existence of dihydrogen bonding and how it affects the total energy that stabilizes the host-guest complexes of CDs·B12H122- compared to the general hydrogen bonding interaction in CDs·B12F122-. This work clearly exhibits strong influences on the electronic structures of dodecaborates upon clustering with CDs, with both size (a-, ß-, ?-) and molecular (X = H or F) specificities, thus providing critical molecular-level information on the cyclodextrin-closo-dodecaborate interactions of interest to medical applications, e.g. Boron neutron capature therapy. The NIPES experiments done at PNNL were supported by the U.S. Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences and Bioscience (X.-B.W.) and was performed at the EMSL, a national scientific user facility sponsored by DOE’s Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory. H.S. and Z.S. acknowledge the funding support of National Natural Science Foundation of China (Nos.11727810, 61720106009 and 21603074), the Science and Technology Commission of Shanghai Municipality (Nos. 19JC1412200), and the Program of Introducing Talents of Discipline to Universities 111 project (B12024). Z. L. thanks the China Scholarship Council (CSC) for financial support. We acknowledge the ECNU Multifunctional Platform for Innovation (001) and HPC Research Computing Team for providing computational and storage resources. J.W. acknowledges support from the Alexander von Humboldt foundation (Feodor Lynen Fellowship and Rückkehrerstipendium), a Freigeist fellowship of the Volkswagenfoundation and Prof. Vladimir A. Azov for helpful discussions.

Li, Zhipeng↗

High brightness diode-pumped organic solid-state laser

High-power, diffraction-limited organic solid-state laser operation has been achieved in a vertical external cavity surface-emitting organic laser (VECSOL), pumped by a low-cost compact blue laser diode. The diode-pumped VECSOLs were demonstrated with various dyes in a polymer matrix, leading to laser emissions from 540 nm to 660 nm. Optimization of both the pump pulse duration and output coupling leads to a pump slope efficiency of 11% for a DCM based VECSOLs. We report output pulse energy up to 280 nJ with 100 ns long pump pulses, leading to a peak power of 3.5 W in a circularly symmetric, diffraction-limited beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chapter 2: Evaluating a Concentrating Solar Power Plantas an Extended-Duration Peaking Resource

We explore the ability of a concentrating solar power (CSP) plant with thermal energy storage (TES) to provide peaking capacity. We focus on future power systems, wherein net load patterns may be significantly different than they are today (e.g., due to higher renewable-energy penetrations). We examine 28 locations in the southwestern United States over an 18-year period. The hourly operation of the CSP plants are simulated to determine their potential to provide energy during an eight-hour peak-load window for each day up to 365 days per year. Our result shows that for the large majority of locations and years, CSP plants with certain configurations (i.e., in terms of solar field and TES sizes) can provide nearly 100% peak-load capacity. We examine also the amount of supplemental energy (e.g.,by using natural gas as a supplemental thermal-energy source) that would be required to ensure that a CSP plant could serve the eight highest-load hours of every day of the year. We find that in most cases, a CSP plant supplemented with natural gas would require less than 5% of the fuel that is used by a natural-gas fired power plant providing the same level of reliable capacity. A series of sensitivity analyses show that these results are robust to the number of peak-load hours and days that are considered and the configuration of the CSP plant.

capacity value↗

Computational Modeling of Vertical-Cavity Surface-Emitting Lasers

Vertical-Cavity Surface-Emitting Lasers (VCSELs) have become increasingly important for many applications, such as optical interconnects and optical data storages. In many applications, critical requirements are very often high beam quality and/or high output powers. To help the design and optimization of VCSELs for such applications, it is essential to have a simulation model that includes the time evolution of the transverse space dependence of the hewn. Such models allow arbitrary transverse profiles of laser intensity or carrier density to develop in time without any a priori assumption about the number and types of transverse modes. In addition, extensive research in the past has shown that many-body effects are important in influencing the optical gain and the refractive index of semiconductor quantum wells. It is thus important to include the key many-body effects in simulation models for semiconductor lasers. A computational model, called the Maxwell-Effective Bloch Equations (MEBE) was developed recently that simulates the above features and effects. This model combines the space-time resolution with microscopic many-body effects in a way that is both accurate enough and computationally manageable. This model has been used to simulate edge-emitting high power lasers recently. A new finite-difference algorithm has been developed for solving these equations and will be shown in the presentation. That algorithm will be used to calculate the detailed time evolution of the transverse mode profiles of VCSELs. The VCSELs are based on InGaAs/GaAs quantum well structures. Effects of pumping current and refractive index profiles will be investigated in detail. The simulation results will be compared with other results the use the rate-equation model.

Goorjian, Peter M.↗

Computational Nonlinear of Vertical-Cavity Surface-Emitting Lasers

Vertical-Cavity Surface-Emitting Lasers (VCSELs) have become increasingly important for many applications, such as optical interconnects and optical data storages. In many applications, critical requirements are very often high beam quality and/or high output powers. To help the design and optimization of VCSELs for such applications, it is essential to have a simulation model that includes the time evolution of the transverse space dependence of the beam. Such models allow arbitrary transverse profiles of laser intensity or carrier density to develop in time without any a priori assumption about the number and types of transverse modes. In addition, extensive research in the past has shown that many-body effects are important in influencing the optical gain and the refractive index of semiconductor quantum wells. It is thus important to include the key many-body effects in simulation models for semiconductor lasers. A computational model, called the Maxwell-Effective Bloch Equations (MEBE) was developed recently that simulates the above features and effects. This model combines the space-time resolution with microscopic many-body effects in a way that is both accurate enough and computationally manageable. This model has been used to simulate edge-emitting high power lasers recently. A new finite-difference algorithm has been developed for solving these equations and will be shown in the presentation. That algorithm will be used to calculate the detailed time evolution of the transverse mode profiles of VCSELs. The VCSELs are based on InGaAs/GaAs quantum well structures. Effects of pumping current and refractive index profiles will be investigated in detail. The simulation results will be compared with other results the use the rate-equation model.

Goorjian, Peter M.↗

A proton beam energy modulator for rapid proton therapy

We present the design for a rapid proton energy modulator with radiofrequency accelerator cavities, which can deliver the proton radiation dose to varied depth in human tissues much faster than traditional mechanical beam energy degraders. The proton energy modulator is designed as a multi-cell 1-m long accelerator working at 2.856 GHz. Each individual accelerator cavity is powered by a 400 kW compact klystron to provide an accelerating/decelerating gradient of 30 MV/m. The high gradient is enabled by the individual power coupling regime, which provides a high shunt impedance. Beam dynamics simulations were performed, showing that the energy modulator can provide ±30 MeV of beam energy change for a 150 MeV, 7 mm long (full length) proton bunch, and the total energy spread of 3 MeV is satisfactory to clinical needs. A prototype experiment of a single cell has been built and tested, and the low-power microwave measurement results agree very well with simulations. The energy modulator is optimized for the 150 MeV cyclotron proton beam, while this approach can work with different beam energies.

47 OTHER INSTRUMENTATION↗

SU-E-T-632: Preliminary Study On Treating Nose Skin Using Energy and Intensity Modulated Electron Beams with Monte Carlo Based Dose Calculations

Purpose: Uneven nose surfaces and air cavities underneath and the use of bolus present complexity and dose uncertainty when using a single electron energy beam to plan treatments of nose skin with a pencil beam-based planning system. This work demonstrates more accurate dose calculation and more optimal planning using energy and intensity modulated electron radiotherapy (MERT) delivered with a pMLC. Methods: An in-house developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reduce the scatter-caused penumbra, a short SSD (61 cm) was used. Our previous work demonstrates good agreement in percentage depth dose and off-axis dose between calculations and film measurement for various field sizes. A MERT plan was generated for treating the nose skin using a patient geometry and a dose volume histogram (DVH) was obtained. The work also shows the comparison of 2D dose distributions between a clinically used conventional single electron energy plan and the MERT plan. Results: The MERT plan resulted in improved target dose coverage as compared to the conventional plan, which demonstrated a target dose deficit at the field edge. The conventional plan showed higher dose normal tissue irradiation underneath the nose skin while the MERT plan resulted in improved conformity and thus reduces normal tissue dose. Conclusion: This preliminary work illustrates that MC-based MERT planning is a promising technique in treating nose skin, not only providing more accurate dose calculation, but also offering an improved target dose coverage and conformity. In addition, this technique may eliminate the necessity of bolus, which often produces dose delivery uncertainty due to the air gaps that may exist between the bolus and skin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acoustic design criteria in a general system for structural optimization

Passenger comfort is of great importance in most transport vehicles. For instance, in the new generation of regional turboprop aircraft, a low noise level is vital to be competitive on the market. The possibilities to predict noise levels analytically has improved rapidly in recent years. This will make it possible to take acoustic design criteria into account in early project stages. The development of the ASKA FE-system to include also acoustic analysis has been carried out at Saab Aircraft Division and the Aeronautical Research Institute of Sweden in a joint project. New finite elements have been developed to model the free fluid, porous damping materials, and the interaction between the fluid and structural degrees of freedom. The FE approach to the acoustic analysis is best suited for lower frequencies up to a few hundred Hz. For accurate analysis of interior cabin noise, large 3-D FE-models are built, but 2-D models are also considered to be useful for parametric studies and optimization. The interest is here focused on the introduction of an acoustic design criteria in the general structural optimization system OPTSYS available at the Saab Aircraft Division. The first implementation addresses a somewhat limited class of problems. The problems solved are formulated: Minimize the structural weight by modifying the dimensions of the structure while keeping the noise level in the cavity and other structural design criteria within specified limits.

Brama, Torsten↗

SU-E-J-58: Dosimetric Verification of Metal Artifact Effects: Comparison of Dose Distributions Affected by Patient Teeth and Implants

Purpose: Implant-supported dentures seem particularly appropriate for the predicament of becoming edentulous and cancer patients are no exceptions. As the number of people having dental implants increased in different ages, critical dosimetric verification of metal artifact effects are required for the more accurate head and neck radiation therapy. The purpose of this study is to verify the theoretical analysis of the metal(streak and dark) artifact, and to evaluate dosimetric effect which cause by dental implants in CT images of patients with the patient teeth and implants inserted humanoid phantom. Methods: The phantom comprises cylinder which is shaped to simulate the anatomical structures of a human head and neck. Through applying various clinical cases, made phantom which is closely allied to human. Developed phantom can verify two classes: (i)closed mouth (ii)opened mouth. RapidArc plans of 4 cases were created in the Eclipse planning system. Total dose of 2000 cGy in 10 fractions is prescribed to the whole planning target volume (PTV) using 6MV photon beams. Acuros XB (AXB) advanced dose calculation algorithm, Analytical Anisotropic Algorithm (AAA) and progressive resolution optimizer were used in dose optimization and calculation. Results: In closed and opened mouth phantom, because dark artifacts formed extensively around the metal implants, dose variation was relatively higher than that of streak artifacts. As the PTV was delineated on the dark regions or large streak artifact regions, maximum 7.8% dose error and average 3.2% difference was observed. The averaged minimum dose to the PTV predicted by AAA was about 5.6% higher and OARs doses are also 5.2% higher compared to AXB. Conclusion: The results of this study showed that AXB dose calculation involving high-density materials is more accurate than AAA calculation, and AXB was superior to AAA in dose predictions beyond dark artifact/air cavity portion when compared against the measurements.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP2-02: First Experiences and Perspectives in Using Direct Multicriteria Optimization (MCO) On Volumetric-Modulated Arc Therapy (VMAT) for Head and Neck Cancer

Purpose: To report the first experiences and perspectives in using direct multicriteria optimization (MCO) on volumetric-modulated arc therapy (VMAT) for head and neck (H&N) cancer. Methods: Ten prior patients with tumors in representative H&N regions were selected to evaluate direct MCO-VMAT in RayStation v5.0 beta. The patients were previously treated by intensity-modulated radiation therapy (IMRT) with MCO on an Elekta linear accelerator with Agility multileaf collimator. To avoid radiating eyes and shoulders, MCO-VMAT required one to three partial-arc groups, with each group consisting of single or dual arcs. All MCO-VMAT plans were approved by a radiation oncologist. The MCO-VMAT and MCO-IMRT plans were compared using V{sub 100}, D{sub 5}, homogeneity index (HI) and conformity index (CI) for planning target volume (PTV), D{sub mean} and D{sub 50} for six parallel organs and D{sub max} for five serial organs. Patient-specific quality assurance (QA) was performed using ArcCHECK for MCO-VMAT and Matrixx for MCO-IMRT with results analyzed using gamma criteria of 3%/3mm. Results: MCO-VMAT provided better V{sub 100} (+0.8%) lower D{sub 5}(− 0.3 Gy), lower HI (−0.27) and comparable CI (+0.05). MCO-VMAT decreased D{sub mean} and D{sub 50} for multiple parallel organs in seven of the ten patients. On average the reduction ranged from 2.1 (larynx) to 7.6 Gy (esophagus). For the nasal cavity and nasopharynx plans significant reduction in D{sub max} was observed for optics (up to 11 Gy) brainstem (6.4 Gy), cord (2.1 Gy) and mandible (6.7 Gy). All MCO-VMAT and -IMRT plans passed clinical QA. MCO-VMAT required slightly longer planning time due to the more complex VMAT optimization. The net beam-on time for the MCO-VMAT plans ranged from 80 to 242 seconds, up to 9 minutes shorter than MCO-IMRT. Conclusion: With similar target coverage, reduced organ dose, comparable planning time, and significantly faster treatment, MCO-VMAT is very likely to become the modality of choice in RayStation v5.0 for H&N cancer.