At least 595 records · Page 33

Nb 3 Sn Superconducting Cavities by Bronze Routes for Accelerator Stewardship

This project explored the challenges of making Nb 3 Sn superconducting radio-frequency (SRF) cavities by bronze routes. The SRF research community has prioritized Nb 3 Sn for many reasons, including the possibility to operate linacs for stewardship applications in continuous-wave mode with compact cryogenic systems. Existing Nb 3 Sn approaches use a cavity body made of niobium and apply tin to the polished cavity interior, a starting point that contains the main costs of present niobium cavity technology. Further complexity is then added because a high vacuum and temperature >1100 °C must be used to prevent formation of undesirable Nb-Sn phases, de-gas interstitial contaminants, and maintain the high purity of the Nb body. The project sought a more cost-effective solution for the same performance opportunities by exploiting the Cu-Sn-Nb diffusion reactions used to make Nb 3 Sn superconducting wires for magnets, which can be carried out at ~700 °C and are compatible with much cheaper copper cavity bodies. The project also sought understanding of the materials science and factors that affect superconducting properties. The project has impacted SRF cavity technology by demonstrating feasibility of alternative routes that enable compact, high-power electron accelerators for energy, security, environment, medical, and commercial applications.

43 PARTICLE ACCELERATORS↗

Planned Use of Pulsed Crab Cavities for Short X-Ray Pulse Generation at the Advanced Photon Source

Recently, we have explored application to the Advanced Photon Source (APS) of Zholents'[1] crab cavity scheme for production of short x-ray pulses. We assumed use of superconducting (SC) cavities in order to have a continuous stream of crabbed bunches and flexibility of operating modes. The challenges of the SC approach are related to the size, cost, and development time of the cavities and associated systems. A good case can be made [2] for a pulsed system using room-temperature cavities. APS has elected to pursue such a system in the near term, with the SC-based system planned for a later date. This paper describes the motivation for the pulsed system and gives an overview of the planned implementation and issues. Among these are overall configuration options and constraints, cavity design options, frequency choice, cavity design challenges, tolerances, instabilities, and diagnostics plans.

43 PARTICLE ACCELERATORS↗

Performance of 3.9 GHz SRF cavities at Fermilab's ILCTA_MDB nhorizontal test stand

Fermilab is building a cryomodule containing four 3.9 GHz superconducting radio frequency (SRF) cavities for the Free electron LASer in Hamburg (FLASH) facility at the Deutsches Elektronen-SYnchrotron (DESY) laboratory. Before assembling the cavities into the cryomodule, each individual cavity is tested at Fermilab's Horizontal Test Stand (HTS). The HTS provides the capability to test fully-dressed SRF cavities at 1.8 K with high-power pulsed RF in order to verify that the cavities achieve performance requirements under these conditions. The performance at the HTS of the 3.9 GHz cavities built for FLASH is presented here.

43 PARTICLE ACCELERATORS↗

Rescoring Docking Hit Lists for Model Cavity Sites: Predictions And Experimental Testing

Molecular docking computationally screens thousands to millions of organic molecules against protein structures, looking for those with complementary fits. Many approximations are made, often resulting in low 'hit rates'. A strategy to overcome these approximations is to rescore top-ranked docked molecules using a better but slower method. One such is afforded by molecular mechanics-generalized Born surface area (MM-GBSA) techniques. These more physically realistic methods have improved models for solvation and electrostatic interactions and conformational change compared to most docking programs. To investigate MM-GBSA rescoring, we re-ranked docking hit lists in three small buried sites: a hydrophobic cavity that binds apolar ligands, a slightly polar cavity that binds aryl and hydrogen-bonding ligands, and an anionic cavity that binds cationic ligands. These sites are simple; consequently, incorrect predictions can be attributed to particular errors in the method, and many likely ligands may actually be tested. In retrospective calculations, MM-GBSA techniques with binding-site minimization better distinguished the known ligands for each cavity from the known decoys compared to the docking calculation alone. This encouraged us to test rescoring prospectively on molecules that ranked poorly by docking but that ranked well when rescored by MM-GBSA. A total of 33 molecules highly ranked by MM-GBSA for the three cavities were tested experimentally. Of these, 23 were observed to bind-these are docking false negatives rescued by rescoring. The 10 remaining molecules are true negatives by docking and false positives by MM-GBSA. X-ray crystal structures were determined for 21 of these 23 molecules. In many cases, the geometry prediction by MM-GBSA improved the initial docking pose and more closely resembled the crystallographic result; yet in several cases, the rescored geometry failed to capture large conformational changes in the protein. Intriguingly, rescoring not only rescued docking false positives, but also introduced several new false positives into the top-ranking molecules. We consider the origins of the successes and failures in MM-GBSA rescoring in these model cavity sites and the prospects for rescoring in biologically relevant targets.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance of Single Crystal Niobium Cavities

We have fabricated and tested a total of six single cell niobium cavities, made from single crystal, high purity niobium. Two of the three cavities of the TESLA shape (1300 MHz) were made from Heraeus niobium by extending a smaller single crystal by rolling and annealing steps; the third cavity was made by spinning from CBMM material. The three other cavities of the scaled "Low Loss" (LL) shape (two) and "High Gradient" (HG) shape (one) resonated at 2.3 GHz and were fabricated from "as received" single crystals, both from Heraeus and CBMM niobium. After appropriate surface treatments by buffered chemical polishing and electropolishing most cavities performed quite nicely and peak surface magnetic fields of ~ 160 mT or above corresponding to accelerating gradients between 38 MV/m and 45 MV/m were reached. This paper reports about the performance of these cavities.

43 PARTICLE ACCELERATORS↗

Coaxial coupling scheme for fundamental and higher order modes in superconducting cavities

Higher Order Modes generated by a particle beam passing through a superconducting accelerating cavity have to be damped to avoid beam instabilities. A coaxial coupler located in the beam pipes of the cavities provides for better propagation of HOMs and strong damping in appropriate HOM dampers. The whole damping device can be designed as a detachable system. If appropriately dimensioned, the RF currents can be minimized at the flange position. Additionally, the coaxial system also provides efficient coupling of fundamental mode RF power into the superconducting cavity. Compared to presently available solutions for HOM damping, this scheme provides for several advantages: stronger HOM damping, attachable solution, and exchangeability of the HOM damping device on a cavity, less complexity of the superconducting cavity, possible cost advantages. This contribution discusses modeling, which lead to an optimized layout of a cavity-coupler system and describes results from the room temperat

43 PARTICLE ACCELERATORS↗

1500 MHZ Passive SRF Cavity for Bunch Lengthening in the NSLS-II Storage Ring

NSLS-II is a new ultra-bright 3 GeV 3rd generation synchrotron radiation light source. The performance goals require operation with a beam current of 500mA and a bunch current of at least 0.5mA. Ion clearing gaps are required to suppress ion effects on the beam. The natural bunch length of 3mm is planned to be lengthened by means of a third harmonic cavity in order to increase the Touschek limited lifetime. After an extensive investigation of different cavity geometries, a passive, superconducting two-cell cavity has been selected for prototyping. The cavity is HOM damped with ferrite absorbers on the beam pipes. The two-cell cavity simplifies the tuner design, compared to having two independent cells. Tradeoffs between the damping of the higher order modes, thermal isolation associated with the large beam tubes, and overall cavity length are described. A copper prototype has been constructed, and measurements of fundamental and higher order modes will be compared to calculated values.

43 PARTICLE ACCELERATORS↗

Measurements of SCRF cavity dynamic heat load in horizontal test system

The Horizontal Test System (HTS) at Fermilab is currently testing fully assembled, dressed superconducting radio frequency (SCRF) cavities. These cavities are cooled in a bath of superfluid helium at 1.8K. Dissipated RF power from the cavities is a dynamic heat load on the cryogenic system. The magnitude of heat flux from these cavities into the helium is also an important variable for understanding cavity performance. Methods and hardware used to measure this dynamic heat load are presented. Results are presented from several cavity tests and testing accuracy is discussed.

43 PARTICLE ACCELERATORS↗

Temperature-dependent cavity swelling in dual-ion irradiated Fe and Fe-Cr ferritic alloys

Fe-Cr ferritic-martensitic (FM) steels are promising structural material candidates for fusion and advanced fission reactors due to their attractive mechanical properties and volumetric swelling resistance. However, significant discrepancies exist regarding the effect of solutes and irradiation temperature on cavity swelling under ion versus neutron irradiation conditions. In this study, simultaneous dual ion irradiations (8 MeV Ni 3+ ions and energy-degraded 3.5 MeV He 2+ ions) were used to quantify the cavity swelling behavior in ultra-high purity Fe and Fe-Cr alloys (3-14 wt.% Cr), Fe-10 wt.% Cr-780 wt.ppm C, and Eurofer97 FM steel. The irradiations were conducted over a wide temperature range (400-550°C) with a mid-range dose of ~30 displacements per atom (dpa) and 0.1 appm/dpa He implantation rate. Here, using state-of-the-art transmission electron microscopy (TEM), we reveal that pure Fe has a ~50°C lower peak swelling temperature difference than Fe-Cr alloys, which is attributed to higher vacancy mobility in pure Fe. Chromium solute appears to strongly suppress cavity swelling in Fe-Cr alloys for temperatures below ~470°C, but seems to have little effect or slightly enhances swelling above ~470°C. Cavities were observed in all the irradiated samples between 400-550°C. This indicates that the narrow temperature range of observable cavities reported in prior ion irradiated Fe-Cr ferritic alloy studies is likely an artifact associated with the use of low ion energies (<5 MeV), which leads to pronounced near-surface and implanted ion effects that suppress cavity swelling even at midrange depths (particularly at high temperatures).

36 MATERIALS SCIENCE↗

Computing resonant modes of accelerator cavities by solving nonlinear eigenvalue problems via rational approximation

Here, we present an efficient and reliable algorithm for solving a class of nonlinear eigenvalue problems arising from the modeling of particle accelerator cavities. The eigenvalue nonlinearity in these problems results from the use of waveguides to couple external power sources or to allow certain excited electromagnetic modes to exit the cavity. We use a rational approximation to reduce the nonlinear eigenvalue problem first to a rational eigenvalue problem. We then apply a special linearization procedure to turn the rational eigenvalue problem into a larger linear eigenvalue problem with the same eigenvalues, which can be solved by existing iterative methods. By using a compact scheme to represent both the linearized operator and the eigenvectors to be computed, we obtain a numerical method that only involves solving linear systems of equations of the same dimension as the original nonlinear eigenvalue problem. We refer to this method as a compact rational Krylov (CORK) method. We implemented the CORK method in the Omega3P module of the Advanced Computational Electromagnetic 3D Parallel (ACE3P) simulation suite and validated it by comparing the computed cavity resonant frequencies and damping Q factors of a small model problem to those obtained from a fitting procedure that uses frequency responses computed by another ACE3P module called S3P. We also used the CORK method to compute trapped modes damped in an ideal eight 9-cell SRF cavity cryomodule. This was the first time it was possible to compute these modes directly. The damping Q factors of the computed modes match well with those measured in experiments and the difference in resonant frequencies is within the range introduced by cavity imperfection. Therefore, the CORK method is an extremely valuable tool for computational cavity design.

43 PARTICLE ACCELERATORS↗

Quantum Mechanical Calculations on Selectivity in the KcsA Channel: The Role of the Aqueous Cavity

We have carried out quantum calculations on selected residues at the intracellular side of the selectivity filter of the KcsA potassium channel, using the published X-ray coordinates as starting points. The calculations involved primarily the side chains of residues lining the aqueous cavity on the intracellular side of the selectivity filter, in addition to water molecules, plus a K+ or Na+ ion. The results showed unambiguously that Na+ significantly distorts the symmetry of the channel at the entrance to the selectivity filter (at the residue T75), while K+ does so to a much smaller extent. In all, three ion positions have been calculated: the S4 (lowest) position at the bottom of the selectivity filter, the top of the cavity, and the midpoint of the cavity; Na+ is trapped at the cavity top, while K+ is cosolvated by the selectivity filter carbonyl groups plus threonine hydroxyl groups so that it can traverse the filter. Only one water molecule remains in the K+ solvation shell at the upper position in the cavity; this solvation shell also contains four threonine (T75) hydroxyl oxygens and two backbone carbonyls, while Na+ is solvated by five molecules of water and one oxygen from threonine hydroxyls. T75 at the entrance to the selectivity filter has a key role in recognition of the alkali ion, and T74 has secondary importance. The energetic basis for the preferential bonding of potassium by these residues is briefly discussed, based on additional calculations. Taken together, the results suggest that Na+ would have difficulty entering the cavity, and if it did, it would not be able to enter the selectivity filter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observations of Density Cavities and Associated Warm Ion Flux Enhancements in the Inner Magnetosphere

We present a statistical study of density cavities observed in the inner magnetosphere by the Van Allen Probes during four one-month periods: February 2013, July 2013, January 2014, and June 2014. These periods were chosen to allow the survey of all magnetic local times. We find that density cavities are a recurrent feature of the density profiles of in situ measurements in the inner magnetosphere. We further investigate the correlation between the density cavities and the enhancement of fluxes of warm ions with energies of 10–100 eV. The results show that warm ion flux enhancements associated with the density cavities were observed more frequently for H + , then for He + and the least frequently for O + . The occurrences of the associated flux enhancements were increased when considering only the cavities inside the plasmasphere. Possible mechanisms responsible for the observed warm ion flux enhancements and the role of density cavities on these ion flux enhancements are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Broadband continuous single-mode tuning of a short-cavity quantum-cascade VECSEL

Changing the length of a laser cavity is a simple method for continuously tuning the wavelength of a laser but is rarely used for broad fractional tuning, with a notable exception of the vertical-cavity surface-emitting laser (VCSEL). This is because, to avoid mode hopping, the cavity must be kept optically short to ensure a large free spectral range compared to the gain bandwidth of the amplifying material. Terahertz quantum-cascade lasers are ideal candidates for such a short cavity scheme as they demonstrate exceptional gain bandwidths (up to octave spanning) and can be integrated with broadband amplifying metasurfaces. Our report presents such a quantum-cascade metasurface-based vertical-external-cavity surface-emitting laser (VECSEL) that exhibits over 20% continuous fractional tuning of a single laser mode. Such tuning is possible because the metasurface has subwavelength thickness, which allows lasing on low-order Fabry–Pérot cavity modes. Good beam quality and high output power are simultaneously obtained.

42 ENGINEERING↗

Low-loss stable storage of 1.2 Å X-ray pulses in a 14 m Bragg cavity

Here, we present an experimental demonstration of a stable, low-loss, large X-ray cavity operating at 1.2 Å wavelength. The cavity consists of four separate high-reflectivity single crystal diamond Bragg mirrors arranged in a rectangular configuration with a round-trip distance of 14.2 m. Femtosecond X-ray pulses from an X-ray free-electron laser were coupled into the cavity via a transmission phase grating. We show that a stable mode can be maintained with the introduction of cavity focusing and measure round-trip efficiencies approaching 88%, or >96% when excluding grating and lens losses, close to the Bragg mirror theoretical performance limit. The direct observation of sustained stable X-ray circulation provides the most direct evidence to date that cavity-based X-ray free-electron lasers and other cavity-based hard X-ray systems are feasible.

47 OTHER INSTRUMENTATION↗

Reducing experimental uncertainty in the calculation of cavity swelling in a transmission electron microscope through crystallographically aided void volume tracking

Accurate measurement of cavity swelling in a transmission electron microscope is essential to define material performance under irradiation, and the conventionally applied spherical assumption for the calculation of cavity volumes in irradiated materials can result in errors ranging between a 25% underestimation and 72% overestimation of volume purely based on the assumption of shape. This assumption is undeniably expedient for calculation but does not sufficiently account for the 3D nature of polyhedral cavities and their shape projection in the transmission electron microscope, and therefore presents too large of an associated uncertainty in swelling determination for faceted cavities. This uncertainty has been defined for many common cavity shapes in FCC and BCC crystal systems, and has been tabulated across the cubic fundamental region. A revised methodology for crystallographically aided void volume tracking, or CAVV-T, is presented and demonstrated on a specimen of neutron irradiated Ni. In-depth discussion on the application of this technique is provided along with resources to allow for conversion between the spherical assumption and this revised method. This work seeks to increase experimental confidence in the characterization and quantification of critical aspects of irradiation damage in materials by applying a crystallographically-resolved approach for cavity swelling calculation.

Haag IV, James V. [Pacific Northwest National Labo↗

The first high-redshift cavity power measurements of cool-core galaxy clusters with the International LOFAR Telescope

Radio-mode feedback associated with the active galactic nuclei (AGNs) at the cores of galaxy clusters injects a large amount of energy into the intracluster medium (ICM), offsetting radiative losses through X-ray emission. This mechanism prevents the ICM from rapidly cooling down and fueling extreme starburst activity as it accretes onto the central galaxies, and it is therefore a key ingredient in the evolution of galaxy clusters. However, the influence and mode of feedback at high redshifts (z ∼ 1) remains largely unknown. Low-frequency sub-arcsecond-resolution radio observations taken with the International LOFAR Telescope have demonstrated their ability to assist X-ray observations with constraining the energy output from the AGNs (or “cavity power”) in galaxy clusters, thereby enabling research at higher redshifts than before. In this pilot project, we tested this hybrid method on a high-redshift (0.6 < z < 1.3) sample of 13 galaxy clusters for the first time with the aim of verifying the performance of this method at these redshifts and providing the first estimates of the cavity power associated with the central AGN for a sample of distant clusters. We were able to detect clear radio lobes in three out of 13 galaxy clusters at redshifts of 0.7 < z < 0.9, and we used these detections in combination with ICM pressures surrounding the radio lobes obtained from standard profiles to calculate the corresponding cavity powers of the AGNs. Combining our results with the literature, the current data appear to suggest that the average cavity power peaked at a redshift ofz ∼ 0.4 and slowly decreases toward higher redshifts. However, we require more and tighter constraints on the cavity volume and a better understanding of our observational systematics to confirm any deviation of the cavity power trend from a constant level.

Astronomy & Astrophysics↗

Cryogenic Infrastructure Upgrade of the Fermilab Magnet and Vertical Cavity Test Facilities

The Fermilab Magnet Test Facility (MTF) and the Vertical Cavity Test Facility (VCTF), both located in Industrial Building 1 and serviced by a shared cryogenic infrastructure, provide cryogenic testing of superconducting magnets and superconducting radio‐frequency cavities in support of programs such as the Tevatron, US‐LHC, LARP, HINS, Project X, and the ILC. While MTF must continue to support a robust magnet test program, VCTF is expected to increase its cavity test throughput by a factor of five, reaching 250 cavity test cycles per year as cavity production ramps up. A cryogenic infrastructure upgrade program has been undertaken in preparation for meeting the challenge of this additional cavity test throughput. The cryogenic infrastructure improvements include dedicated ambient temperature vacuum pumps, a helium compressor, purification skids, and additional helium gas storage. This paper will elaborate on the goals of the upgrade program, the selected equipment, and foreseen integration and operations plans and issues.

Rabehl, R.↗

Integrated fiber-mirror ion trap for strong ion-cavity coupling

We present and characterize fiber mirrors and a miniaturized ion-trap design developed to integrate a fiber-based Fabry-Perot cavity (FFPC) with a linear Paul trap for use in cavity-QED experiments with trapped ions. Our fiber-mirror fabrication process not only enables the construction of FFPCs with small mode volumes, but also allows us to minimize the influence of the dielectric fiber mirrors on the trapped-ion pseudopotential. We discuss the effect of clipping losses for long FFPCs and the effect of angular and lateral displacements on the coupling efficiencies between cavity and fiber. Optical profilometry allows us to determine the radii of curvature and ellipticities of the fiber mirrors. From finesse measurements, we infer a single-atom cooperativity of up to 12 for FFPCs longer than 200 μm in length; comparison to cavities constructed with reference substrate mirrors produced in the same coating run indicates that our FFPCs have similar scattering losses. We characterize the birefringence of our fiber mirrors, finding that careful fiber-mirror selection enables us to construct FFPCs with degenerate polarization modes. As FFPCs are novel devices, we describe procedures developed for handling, aligning, and cleaning them. We discuss experiments to anneal fiber mirrors and explore the influence of the atmosphere under which annealing occurs on coating losses, finding that annealing under vacuum increases the losses for our reference substrate mirrors. X-ray photoelectron spectroscopy measurements indicate that these losses may be attributable to oxygen depletion in the mirror coating. Special design considerations enable us to introduce a FFPC into a trapped ion setup. Our unique linear Paul trap design provides clearance for such a cavity and is miniaturized to shield trapped ions from the dielectric fiber mirrors. We numerically calculate the trap potential in the absence of fibers. In the experiment additional electrodes can be used to compensate distortions of the potential due to the fibers. Home-built fiber feedthroughs connect the FFPC to external optics, and an integrated nanopositioning system affords the possibility of retracting or realigning the cavity without breaking vacuum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗