Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Fast image acquisition system and method using pulsed light illumination and sample scanning to capture optical micrographs with sub-micron features

An optical inspection system for detecting sub-micron features on a sample component. The system may have a controller, a camera responsive to the controller for capturing images, an objective lens able to capture submicron scale features on the sample component, and a pulsed light source. The pulsed light source may be used to generate light pulses. The camera may be controlled to acquire images, using the objective lens, only while the pulsed light source is providing light pulses illuminating a portion of the sample component. Relative movement between the sample component and the objective lens is provided to enable at least one of a desired subportion or an entirety of the sample component to be scanned with the camera.

Yoo, Jae Hyuck↗

Mapping and imaging ionizing radiation in two and three dimensions

A two-dimensional imaging system and a two-dimensional or three-dimensional optical tomographic mapping system, each employing gas scintillation induced by ionizing radiation, i.e., radioluminescence, and corresponding methods, are disclosed. The systems may employ one or more cameras and corresponding UV filters (potentially solar blind filters) for imaging a radioluminescent scene. For two-dimensional or three-dimensional mapping, the resultant UV images are spatially registered with one another and then reconstructed to form a three-dimensional tomographic map of the ionizing radiation. The two-dimensional map is a plane of the three-dimensional map. The UV images may be spatially registered by using a reference source, optionally, a calibrated reference source allowing dosimetry calculations for the ionizing radiation. Molecular nitrogen is the primary candidate for the radioluminescent gas, though a controlled ambient in a chamber of nitric oxide, argon, krypton, or xenon may be employed. The reconstruction process employs an algebraic reconstruction technique or an Abel inversion.

Bentz, Brian Z.↗

Solar mirror soiling and heliostat inspection from a mobile imaging system and mobile platform

A system or method for an imaging system is provided for inspecting a heliostat. The imaging system includes a platform and a camera mounted on the platform and a heliostat having a plurality of mirrored facets. The camera is positioned to acquire a first image that serves as a reference image and a second image that is a reflected image from at least one facet. The camera stores image data associated with the first image and the second image, and wirelessly transmits the stored image data to a computing apparatus. The computing apparatus compares the first image with the second image and determines a performance parameter associated with the heliostat.

Yellowhair, Julius↗

The ITER VIS/IR wide angle viewing system: Challenges and on-going R and D

The ITER tokamak is the next generation fusion device which will allow studying burning plasma obtained by a Deuterium-Tritium (D-T) fusion reaction during hundreds of seconds. ITER vacuum vessel real-time protection will be mandatory during plasma operation to avoid water leaks and critical plasma facing components degradation. The protection system will be based on a wide angle viewing system (WAVS) composed with 18 visible (VIS) and 18 infrared (IR) cameras covering 80 % of the vacuum vessel which will be one of the major imaging systems of ITER. Compared to protection systems routinely used on current tokamaks and based on imaging (VIS and/or IR), new constraints must be taken into account because of their influence on the system performance: the harsh environment (high neutron flux) and the metallic plasma facing components (both first wall and divertor). In this new demanding context, we have achieved three mandatory R and D studies starting from the understanding of the source of signals by using realistic photonic simulation up to real-time processing strategy taken into account first order optical design constraints to define what type of performance could be reached for ITER vacuum vessel protection. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-line, High-Throughput Quality Monitoring for Fuel Cell and Electrolyzer Components Based on Transmission and Reflection Imaging

During the manufacturing of fuel cell and electrolyzer membranes and membrane electrode assemblies (MEAs), real-time, in-line, high-throughput optical-based quality monitoring methods are essential for detecting defects and monitoring thickness variations, thus improving the performance and increasing the durability of fuel cell and electrolyzer in the hydrogen industry. For the MEAs with very opaque coatings, optical transmission-based imaging has been developed and applied in the Roll-to-Roll system using a flashlight and a high-sensitivity CCD camera. We observed high signal-to-noise ratio images while the Roll-to-Roll system ran at 5 ft/min. The entire sample image could quickly be recovered from the discrete frames using customized Python codes for automatic frame cropping and stitching. We detected significant non-uniformities in our experimental MEAs specimen. For fuel cell and low-temperature electrolysis (LTE) transparent membranes, we used optical reflectance hyperspectral imaging with interference fringe-based thickness mapping. We set up a hyperspectral camera to measure various rolls of commercial membranes. The measurement results are analyzed to find the thickness distribution of each roll and to check for defects. Transmission and reflection imaging-based quality monitoring techniques demonstrated in this project can be widely used in the mass production environment to improve the production yield and performance of hydrogen devices.

DIRECT ENERGY CONVERSION,ENGINEERING↗

Enhancing Camera Calibration for Traffic Surveillance with an Integrated Approach of Genetic Algorithm and Particle Swarm Optimization

Recent advancements in sensor technologies, coupled with signal processing and machine learning, have enabled real-time traffic control systems to effectively adapt to changing traffic conditions. Cameras, as sensors, offer a cost-effective means to determine the number, location, type, and speed of vehicles, aiding decision-making at traffic intersections. However, the effective use of cameras for traffic surveillance requires proper calibration. This paper proposes a new optimization-based method for camera calibration. In this approach, initial calibration parameters are established using the Direct Linear Transformation (DLT) method. Then, optimization algorithms are applied to further refine the calibration parameters for the correction of nonlinear lens distortions. A significant enhancement in the optimization process is achieved through the integration of the Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) into a combined Integrated GA and PSO (IGAPSO) technique. The effectiveness of this method is demonstrated through the calibration of eleven roadside cameras at three different intersections. The experimental results show that when compared to the baseline DLT method, the vehicle localization error is reduced by 22.30% with GA, 22.31% with PSO, and 25.51% with IGAPSO.

47 OTHER INSTRUMENTATION↗

Sensor Fusion-Based Vehicle Detection and Tracking Using a Single Camera and Radar at a Traffic Intersection

Recent advancements in sensor technologies, in conjunction with signal processing and machine learning, have enabled real-time traffic control systems to adapt to varying traffic conditions. This paper introduces a new sensor fusion approach that combines data from a single camera and radar to achieve cost-effective and efficient vehicle detection and tracking. Initially, vehicles are independently detected and classified using the camera and radar. Then, the constant-velocity model within a Kalman filter is employed to predict vehicle locations, while the Hungarian algorithm is used to associate these predictions with sensor measurements. Finally, vehicle tracking is accomplished by merging kinematic information from predictions and measurements through the Kalman filter. A case study conducted at an intersection demonstrates the effectiveness of the proposed sensor fusion method for traffic detection and tracking, including performance comparisons with individual sensors.

47 OTHER INSTRUMENTATION↗

KNOW THE STAR, KNOW THE PLANET. V. CHARACTERIZATION OF THE STELLAR COMPANION TO THE EXOPLANET HOST STAR HD 177830

HD 177830 is an evolved K0IV star with two known exoplanets. In addition to the planetary companions it has a late-type stellar companion discovered with adaptive optics imagery. We observed the binary star system with the PHARO near-IR camera and the Project 1640 coronagraph. Using the Project 1640 coronagraph and integral field spectrograph we extracted a spectrum of the stellar companion. This allowed us to determine that the spectral type of the stellar companion is a M4 ± 1 V. We used both instruments to measure the astrometry of the binary system. Combining these data with published data, we determined that the binary star has a likely period of approximately 800 years with a semimajor axis of 100–200 AU. This implies that the stellar companion has had little or no impact on the dynamics of the exoplanets. The astrometry of the system should continue to be monitored, but due to the slow nature of the system, observations can be made once every 5–10 years.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental 3-dimensional tracking of the dynamics of a single electron in the Fermilab Integrable Optics Test Accelerator (IOTA)

We present the results of experimental studies on the transverse and longitudinal dynamics of a single electron in the IOTA storage ring. IOTA is a flexible machine dedicated to beam physics experiments with electrons and protons. A method was developed to reliably inject and circulate a controlled number of electrons in the ring. A key beam diagnostic system is the set of sensitive high-resolution digital cameras for the detection of synchrotron light emitted by the electrons. With 60–130 electrons in the machine, we measured beam lifetime and derived an absolute calibration of the optical system. At exposure times of 0.5 s, the cameras were sensitive to individual electrons. Camera images were used to reconstruct the time evolution of oscillation amplitudes of a single electron in all 3 degrees of freedom. The evolution of amplitudes directly showed the interplay between synchrotron-radiation damping, quantum excitations, and scattering with the residual gas. From the distribution of measured single-electron oscillation amplitudes, we deduced transverse emittances, momentum spread, damping times, and beam energy. Estimates of residual-gas density and composition were calculated from the measured distributions of vertical scattering angles. Combining scattering and lifetime data, we also provide an estimate of the aperture of the ring. To our knowledge, this is the first time that the dynamics of a single electron are tracked in all three dimensions with digital cameras in a storage ring.

43 PARTICLE ACCELERATORS↗

WM26 Paper Multi-Robot Collaboration for Hazardous Environments

Hazardous nuclear and industrial facilities are rarely designed for robots. Work in these domains demand precise manipulation and robust mobility in cluttered, constrained spaces where off-the-shelf platforms struggle and “one-size-fits-all” machines become costly and complex. Idaho National Laboratory (INL) is developing an autonomous, multi-robot inspection system that coordinates task-specific platforms rather than relying on a single omni-tool robot. An electric truck serves as a power and compute hub for a custom manipulator co-developed with Florida International University (FIU), a commercial mini crawler, a pan–tilt–zoom camera, and a Nexxis Argus LiDAR mapping system. Working in concert, these robots generate spatial, radiation, and temperature maps of the pit environments at the Hanford Waste Tank Farms. These systems will capture visual records and environmental telemetry to allow for analysis post inspection. The system architecture uses Robot Operating System 2 (ROS 2) for publish/subscribe integration, NVIDIA Isaac Sim and Unity for simulation and visualization, and algorithms such as NVBlox to fuse data into unified 3D overlays. This robot-agnostic approach reduces operator burden by enabling autonomy across heterogeneous platforms and lets each robot be used where it is strongest. Having autonomous functions means operators don’t have to fully control multiple different components. The ease of use could allow for more widespread adoption of advanced robotics at waste management sites that see continued use. By coordinating simpler, purpose-built mechanisms, the approach lowers design and manufacturing complexity, reduces capital risk in contaminated settings, and improves controllability for complex inspection and manipulation tasks. We present the architecture, early results, and lessons learned from building and deploying this coordinated multi-robot system, with the goal of accelerating safe, cost-effective adoption of advanced robotics at waste-management sites.

42 - ENGINEERING↗

Low latency optical-based mode tracking with machine learning deployed on FPGAs on a tokamak

Active feedback control in magnetic confinement fusion devices is desirable to mitigate plasma instabilities and enable robust operation. Optical high-speed cameras provide a powerful, non-invasive diagnostic and can be suitable for these applications. Here, in this study, we process high-speed camera data, at rates exceeding 100 kfps, on in situ field-programmable gate array (FPGA) hardware to track magnetohydrodynamic (MHD) mode evolution and generate control signals in real time. Our system utilizes a convolutional neural network (CNN) model, which predicts the n = 1 MHD mode amplitude and phase using camera images with better accuracy than other tested non-deep-learning-based methods. By implementing this model directly within the standard FPGA readout hardware of the high-speed camera diagnostic, our mode tracking system achieves a total trigger-to-output latency of 17.6 μs and a throughput of up to 120 kfps. This study at the High Beta Tokamak-Extended Pulse (HBT-EP) experiment demonstrates an FPGA-based high-speed camera data acquisition and processing system, enabling application in real-time machine-learning-based tokamak diagnostic and control as well as potential applications in other scientific domains.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rifle-like camera for long distance face recognition

An improved long-range facial recognition system is provided. The facial recognition system includes an integrated, rifle-like mounting platform with modular and interchangeable components, including a machine-vision camera, a facial recognition module, and an aiming scope. The mounting platform includes an elongated frame, a hand grip, a shoulder stock, and an underbody support attachment for an optional bipod. The mounting platform provides an intuitive, shoulder-operated support structure for stabilizing the machine-vision camera and reducing vibrations that otherwise inhibit long distance imaging.

Bolme, David S.↗

TU-FG-BRB-05: A 3 Dimensional Prompt Gamma Imaging System for Range Verification in Proton Radiotherapy

Purpose: To report on the initial developments of a clinical 3-dimensional (3D) prompt gamma (PG) imaging system for proton radiotherapy range verification. Methods: The new imaging system under development consists of a prototype Compton camera to measure PG emission during proton beam irradiation and software to reconstruct, display, and analyze 3D images of the PG emission. For initial test of the system, PGs were measured with a prototype CC during a 200 cGy dose delivery with clinical proton pencil beams (ranging from 100 MeV – 200 MeV) to a water phantom. Measurements were also carried out with the CC placed 15 cm from the phantom for a full range 150 MeV pencil beam and with its range shifted by 2 mm. Reconstructed images of the PG emission were displayed by the clinical PG imaging software and compared to the dose distributions of the proton beams calculated by a commercial treatment planning system. Results: Measurements made with the new PG imaging system showed that a 3D image could be reconstructed from PGs measured during the delivery of 200 cGy of dose, and that shifts in the Bragg peak range of as little as 2 mm could be detected. Conclusion: Initial tests of a new PG imaging system show its potential to provide 3D imaging and range verification for proton radiotherapy. Based on these results, we have begun work to improve the system with the goal that images can be produced from delivery of as little as 20 cGy so that the system could be used for in-vivo proton beam range verification on a daily basis.

60 APPLIED LIFE SCIENCES↗

DOE Robotic and Remote Systems Assistance to the Government of Japan

At the request of the Government of Japan, DOE did a complex wide survey of available remotely operated and robotic systems to assist in the initial assessment of the damage to the Fukushima Daiichi reactors following an earthquake and subsequent tsunami. As a result several radiation hardened cameras and a Talon robot were identified as systems that could immediately assist in the effort and were subsequently sent to Japan. These systems were transferred to the Government of Japan and used to map radiation levels surrounding the damaged facilities. This report describes the equipment, its use, data collected, and lessons learned from the experience.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam-pointing verification using x-ray pinhole cameras on the 60-beam OMEGA laser

On the OMEGA laser system, the beam-pointing accuracy is verified by irradiating a 4 mm diameter Au-coated spherical target with ~23 kJ of laser energy. Up to ten x-ray pinhole cameras record the x-ray emission from all 60-beam spots. A new set of algorithms has been developed to improve the accuracy of the pointing evaluation. An updated edge-finding procedure allows one to infer the center of the sphere with subpixel accuracy. A new approach was introduced to back-propagate the pixel locations on the 2D image to the 3D surface of the sphere. Furthermore, a fast Fourier transform-based de-noising method significantly improves the signal-to-noise of the data. Based on the beam-pointing analysis, hard-sphere calculations of the laser-drive illumination uniformity on the target surface and the decomposition of the illumination distribution into lower order modes (1–10) are evaluated.

47 OTHER INSTRUMENTATION↗

In-situ tube burst testing and high-temperature deformation behavior of candidate materials for accident tolerant fuel cladding

The high resistance of cladding to plastic deformation and burst failure is one of the most essential properties of accident tolerant fuel (ATF) for maintaining structural integrity during a loss-of-coolant accident (LOCA) since the deformation and burst behavior governs the cooling efficiency of flow channels and process of fission product release. To simulate and evaluate such deformation and burst process of thin-walled cladding, an in-situ testing and evaluation method has been developed on the basis of visual imaging and image analysis techniques. The method uses a specialized optics system consisted of a high-resolution video camera, light filtering unit, and monochromatic light sources, and the in-situ testing is performed using a 50 mm long pressurized thin-walled tubular specimen set in a programmable furnace. In this study eleven (11) candidate cladding materials for ATF, i.e., 6 FeCrAl alloys and 5 nanostructured steels, were tested using the newly developed method, and the time-dependent images were analyzed to produce detailed deformation and burst data such as true hoop stress, strain (creep) rate, and failure stress. Relatively soft FeCrAl alloys deformed and burst below 800°C while negligible strain rates were measured for higher strength alloys and/or for relatively thick wall specimens.

Gussev, Maxim N.↗

Neutron emission profiles and energy spectra measurements at JET

The Joint European Toras (JET, Culham, UK) is the largest tokamak in the world. It is devoted to nuclear fusion experiments of magnetic confined Deuterium (D) or Deuterium-Tritium (DT) plasmas. JET has been upgraded over the years and recently it has also become a test facility of the components designed for ITER, the next step fusion machine under construction in Cadarache (France). JET makes use of many different diagnostics to measure the physical quantities of interest in plasma experiments. Concerning D or DT plasmas neutron production, various types of detectors are implemented to provide information upon the neutron total yield, emission profile and energy spectrum. The neutron emission profile emitted from the JET plasma poloidal section is reconstructed using the neutron camera (KN3). In 2010 KN3 was equipped with a new digital data acquisition system capable of high rate neutron measurements (<0.5 MCps). A similar instrument will be implemented on ITER and it is currently in its design phase. Various types of neutron spectrometers with different view lines are also operational on JET. One of them is a new compact spectrometer (KM12) based on organic liquid scintillating material which was installed in 2010 and implements a similar digital data acquisition system as for KN3. This article illustrates the measurement results of KN3 neutron emission profiles and KM 12 neutron energy spectra from the latest JET D experimental campaign C31.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated control of microfluidic devices based on machine learning

A system is provided to automatically monitor and control the operation of a microfluidic device using machine learning technology. The system receives images of a channel of a microfluidic device collected by a camera during operation of the microfluidic device. Upon receiving an image, the system applies a classifier to the image to classify the operation of the microfluidic device as normal, in which no adjustment to the operation is needed, or as abnormal, in which an adjustment to the operation is needed. When an image is classified as normal, the system may make no adjustment to the microfluidic device. If, however, an image is classified as abnormal, the system may output an indication that the operation is abnormal, output an indication of a needed adjustment, or control the microfluidic device to make the needed adjustment.

42 ENGINEERING↗