Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Intercomparison of Commercially Available Active Radon Measurement Devices in a Discovered Radon Chamber

An unventilated 70 m 3 underground space, with 2.1 m high ceilings and an inner set of concrete walls to damp vibrations, was discovered to have relatively stable radon levels of ~1,080 Bq m -3 over a 1-y period. The addition of radium sources was not required to achieve high and somewhat variable radon levels, as these arise naturally in the space. Several active radon monitoring devices designed for homeowners, radon screeners, radon mitigation professionals, and researchers were tested in the space. These devices were variable in both cost and intended user sophistication. Data were collected at specific time intervals that varied for each device. A cellphone was deployed with an available camera application to periodically capture photographs of the displays of devices not enabled for automatic temporal recording. Attempts were made to alter the radon concentration using fans, radium-laden objects, and radon impermeable sheets. Statistical methods were employed to compare the device's performance under the minor radon transients produced by the addition of 226 Ra sources during the test period. The evaluation of the overall accuracy, noise, and response to transients revealed highly affordable devices that may be useful for future research applications.While unsuitable for precise calibrations at stable radon levels, the space was determined to be adequate as a radon chamber for general research purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-T-03: Verification of Range, SOBP Width, and Output for Passive-Scattering Proton Beams Using a Liquid Scintillator Detector

Purpose: Liquid scintillators have been shown to provide fast and high-resolution measurements of radiation beams. However, their linear energy transfer-dependent response (quenching) limits their use in proton beams. The purpose of this study was to develop a simple and fast method to verify the range, spread-out Bragg peak (SOBP) width, and output of a passive-scattering proton beam with a liquid scintillator detector, without the need for quenching correction. Methods: The light signal from a 20×20×20 cm3 liquid scintillator tank was collected with a CCD camera. Reproducible landmarks on the SOBP depth-light curve were identified which possessed a linear relationship with the beam range and SOBP width. The depth-light profiles for three beam energies (140, 160 and 180 MeV) with six SOBP widths at each energy were measured with the detector. Beam range and SOBP width calibration factors were obtained by comparing the depth-light curve landmarks with the nominal range and SOBP width for each beam setting. The daily output stability of the liquid scintillator detector was also studied by making eight repeated output measurements in a cobalt-60 beam over the course of two weeks. Results: The mean difference between the measured and nominal beam ranges was 0.6 mm (σ=0.2 mm), with a maximum difference of 0.9 mm. The mean difference between the measured and nominal SOBP widths was 0.1 mm (σ=1.8 mm), with a maximum difference of 4.0 mm. Finally an output variation of 0.14% was observed for 8 measurements performed over 2 weeks. Conclusion: A method has been developed to determine the range and SOBP width of a passive-scattering proton beam in a liquid scintillator without the need for quenching correction. In addition to providing rapid and accurate beam range and SOBP measurements, the detector is capable of measuring the output consistency with a high degree of precision. This project was supported in part by award number CA182450 from the National Cancer Institute.

07 ISOTOPE AND RADIATION SOURCES↗

THE EXTRAORDINARY FAR-INFRARED VARIATION OF A PROTOSTAR: HERSCHEL/PACS OBSERVATIONS OF LRLL54361

We report Herschel/Photodetector Array Camera and Spectrometer (PACS) photometric observations at 70 μm and 160 μm of LRLL54361—a suspected binary protostar that exhibits periodic (P = 25.34 days) flux variations at shorter wavelengths (3.6 μm and 4.5 μm) thought to be due to pulsed accretion caused by binary motion. The PACS observations show unprecedented flux variation at these far-infrared wavelengths that are well correlated with the variations at shorter wavelengths. At 70 μm the object increases its flux by a factor of six while at 160 μm the change is about a factor of two, consistent with the wavelength dependence seen in the far-infrared spectra. The source is marginally resolved at 70 μm with varying FWHM. Deconvolved images of the sources show elongations exactly matching the outflow cavities traced by the scattered light observations. The spatial variations are anti-correlated with the flux variation, indicating that a light echo is responsible for the changes in FWHM. The observed far-infrared flux variability indicates that the disk and envelope of this source is periodically heated by the accretion pulses of the central source, and suggests that such long wavelength variability in general may provide a reasonable proxy for accretion variations in protostars.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards a deep characterization of a 64-fold-pixelated position sensitive detector for a new {gamma}-scanning system of HPGe segmented detectors

Characterization of the electrical response of the HPGe segmented detectors is one of the current goals for the Nuclear Physics community in order to perform {gamma}-ray tracking or even imaging with these detectors. For this purpose, scanning devices have to be developed to achieve the signal-position association with the highest precision. In this laboratory, a new scanning system, SALSA (Salamanca Lyso-based Scanning Array), consisting on a high spatial resolution {gamma} camera, is a under development. In this work the whole scanning system is presented and first results for the characterization of the {gamma} camera are shown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introducing a New Spitzer Master BLISS Map to Remove the Instrument Systematic Phase-curve-parameter Degeneracy, as Demonstrated by a Reanalysis of the 4.5 μm WASP-43b Phase Curve

While Spitzer Infrared Array Camera (IRAC) systematics are generally well understood, each data set can provide its own challenges that continue to teach us about the underlying functional form of these systematics. Multiple groups have analyzed the phase curves of WASP-43b with varying detrending techniques, each obtaining different results. In this work, we take another look at WASP-43b while exploring the degenerate relation between Bilinearly Interpolated Subpixel Sensitivity (BLISS) mapping, point response function (PRF)–FWHM detrending, and phase curve parameters. We find that there is a strong correlation between the detrending parameters in the two models, and best-fit phase curve amplitudes vary strongly when the data are temporally binned. To remove this degeneracy, we present a new Gaussian centroided intrapixel sensitivity map (hereafter fixed sensitivity map), generated using 3,712,830 exposures spanning 5 yr, for a variety of aperture sizes at 4.5 μm. We find evidence for time variability in the sensitivity at 3.6 μm and do not generate a visit-independent map for this channel. With the fixed 4.5 μm intrapixel sensitivity map, the best fits for WASP-43b no longer vary strongly with bin size and PRF–FWHM detrending is no longer required to remove correlated noise. For data sets that do not fall completely within the sweet spot, temporal binning should not be used in the analysis of Spitzer phase curves. We confirm nightside emission for WASP-43b with a disk-integrated nightside temperature of 806 ± 48 K at 4.5 μm. The 4.5 μm maps are available at github.com/kevin218/POET.

79 ASTRONOMY AND ASTROPHYSICS↗

Helmet-Mounted Display Of Clouds Of Harmful Gases

Proposed helmet-mounted opto-electronic instrument provides real-time stereoscopic views of clouds of otherwise invisible toxic, explosive, and/or corrosive gas. Display semitransparent: images of clouds superimposed on scene ordinarily visible to wearer. Images give indications on sizes and concentrations of gas clouds and their locations in relation to other objects in scene. Instruments serve as safety devices for astronauts, emergency response crews, fire fighters, people cleaning up chemical spills, or anyone working near invisible hazardous gases. Similar instruments used as sensors in automated emergency response systems that activate safety equipment and emergency procedures. Both helmet-mounted and automated-sensor versions used at industrial sites, chemical plants, or anywhere dangerous and invisible or difficult-to-see gases present. In addition to helmet-mounted and automated-sensor versions, there could be hand-held version. In some industrial applications, desirable to mount instruments and use them similarly to parking-lot surveillance cameras.

Diner, Daniel B.↗

ASTRO-H Soft X-Ray Telescope (SXT)

ASTRO-H is an astrophysics satellite dedicated for X-ray spectroscopic study non-dispersively and to carry out survey complementally, which will be borne out of US-Japanese collaborative effort. Among the onboard instruments there are four conically approximated Wolter-I X-ray mirrors, among which two of them are soft X-ray mirrors\ of which the energy range is from a few hundred eV to 15 keY, currently being fabricated in the X-ray Optics Lab at Goddard Space Flight Center. The focal point instruments will be a calorimeter (SXS) and a CCD camera (SXI), respectively. The reflectors of the mirror are made of heat-formed aluminum substrate of the thickness gauged of 152 micron, 229 micron, and 305 micron of the alloy 5052 H-19, followed by epoxy replication on gold-sputtered smooth Pyrex cylindrical mandrels to acquire the X-ray reflective surface. The epoxy layer is 10 micron nominal and surface gold layer of 0.2 micron. Improvements on angular response over the Astro-El/Suzaku mirrors come from error reduction on the figure, the roundness, and the grazing angle/radius mismatching of the reflecting surface, and tighter specs and mechanical strength on supporting structure to reduce the reflector positioning and the assembly errors. In this paper, we report the results of calibration of the engineering model of SXT (EM), and project the quality of the flight mirrors.

Soong, Yang↗

Light-concentrating microcone array for improving performance of infrared imaging devices

Light-harvesting low-index (n=1.6) microconical arrays are proposed for increasing the sensitivity and the signal-to-noise ratio (SNR) of mid-wave infrared (MWIR) focal plane arrays (FPAs) used in thermal cameras. Numerical modeling showed a 3-D Power enhancement factor ~ 50 in MWIR for 10° tapered microcones with Dt/Db = 60 μm/8μm and h=150μm, where Dt and Db are the top and bottom diameters of microcones, respectively. Such microconical arrays were fabricated in photoresist by using a nanoscribe tool directly on top of the front-illuminated Ni/Si Schottky-barrier, and three-fold enhancement in the photocurrent response was observed. The proposed approach permits increase of the SNR and the operation temperature of the MWIR imaging devices.

Astratov, Vasily N.↗

HIGH-RESOLUTION IMAGING OF THE GEGENSCHEIN AND THE GEOMETRIC ALBEDO OF INTERPLANETARY DUST

We performed optical observations of the Gegenschein using a liquid-nitrogen-cooled wide-field camera, the Wide-field Imager of Zodiacal light with ARray Detector (WIZARD), between 2003 March and 2006 November. We found a narrow brightness enhancement superimposed on the smooth gradient of the Gegenschein at the exact position of the antisolar point. Whereas the Gegenschein morphology changed according to the orbital motion of the Earth, the maximum brightness coincided with the antisolar direction throughout the year. We compared the observed morphology of the Gegenschein with those of models in which the spatial density of the interplanetary dust cloud was considered and found that the volume scattering phase function had a narrow backscattering enhancement. The morphology was reproducible with a spatial distribution model for infrared zodiacal emission. It is likely that the zero-phase peak (the so-called opposition effect) was caused by coherent backscattering and/or shadow-hiding effects on the rough surfaces of individual dust particles. These results suggest that big particles are responsible for both zodiacal light and zodiacal emission. Finally, we derived the geometric albedo of the smooth component of interplanetary dust, assuming big particles, and obtained a geometric albedo of 0.06 {+-} 0.01. The derived albedo is in accordance with collected dark micrometeorites and observed cometary dust particles. We concluded that chondritic particles are dominant near Earth space, supporting the recent theoretical study by dynamical simulation.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements and simulations of the cosmic-ray-induced neutron background

The cosmic-ray-induced neutron background at ground level has been measured and simulated in conjunction with EJ-309 organic liquid scintillators with an approximate deposited energy range of 0.5–6 MeV. Specifically, the pulse height distributions, net neutron count rates, and angular dependences were obtained. The simulations were carried out using the Monte Carlo transport code MCNPX-PoliMi combined with the (Cosmic-Ray Shower Generator) CRY source subroutine that returns secondary particles produced by cosmic rays. A scaling formula from literature was also implemented in the simulation. The angular dependence of the neutron count rate was measured by collimating the liquid scintillator with polyethylene to attain 18° angular resolution from 0° downwards to 72° horizontally. The neutron count rate was measured to be 23.10±1.69 h -1 sr -1 at 0°, and 7.20±0.78 h -1 sr -1 at 72°. The simulations and measurements compare well and show similar cosine anisotropy for the angular distribution. Finally, the study thus shows that the neutron background response in detector systems can be efficiently and accurately simulated using the procedures described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial and Temporal Measurements of Temperature and Cell Viability in Response to Nanoparticle Mediated Photothermal Therapy

Aim: Nanoparticle enhanced photothermal therapy is a promising alternative to tumor resection. However, quantitative measurements of cellular response to these treatments are limited. This paper introduces a Bimodal Enhanced Analysis of Spatiotemporal Temperature (BEAST) algorithm to rapidly determine the viability of cancer cells in vitro following photothermal therapy alone or in combination with nanoparticles. Materials & Methods: To illustrate the capability of the BEAST viability algorithm, single wall carbon nanohorns were added to renal cancer (RENCA) cells in vitro and time-dependent spatial temperature maps measured with an infrared camera during laser therapy were correlated with post-treatment cell viability distribution maps obtained by cell-staining fluorescent microscopy. Conclusion: The BEAST viability algorithm accurately and rapidly determined the cell viability as function of time, space, and temperature.

laser↗

Visualization studies of turbulent transition flows in a porous medium

Results are reported for flow-visualization studies of the flow regimes of water passing through a porous medium consisting of cylindrical glass and plexiglas rods arranged in a complex and fixed three-dimensional geometry. The Reynolds number (Re) varied from 50 to 700; the flow was visualized by injecting a 5% potassium permanganate dye solution into the pores and photographing the resulting dye streaklines with both a still camera and a movie camera. The results indicate that four distinct flow regimes exist in the porous medium: (1) Darcy or creeping flow up to Re = 3; (2) steady inertia-dominated laminar flow for Re = 3-150; (3) unsteady transitional laminar flow for Re = 150-250; and (4) fully turbulent flow for Re greater than 250. It is concluded that a laminar wake instability mechanism typical of the external flow about bluff bodies may be responsible for the overall transition from laminar to turbulent flow in porous media.

Bilardo, V. J.↗

Coaxial color channel focus evaluation to estimate standoff height in directed energy deposition additive manufacturing

Directed energy deposition (DED) is an additive manufacturing process that is being rapidly adopted by industry and is well suited for the fabrication of complex components in a variety of metal alloys. In laser cladding systems such as DED, powder is blown in a stream to a metal substrate coincident with a laser necessary to deposit molten metal with 3D spatial control. The focus of both the laser and the powder stream are crucial, and best deposition occurs at a predetermined standoff height between the build surface and the print head. Generally, no monitoring of this distance is implemented in commercial DED systems. Due to potential over or under building, the standoff height often changes over time but tends to self-correct. However, inexpensive and minimally intrusive methods to identify optimal standoff are required to provide real-time control to maintain the optimal distance. The present work explores the quantification of the focus of the three-color channels of a coaxial camera to determine the standoff height. An experiment was performed in which a 254 mm wall is built and the standoff height, initially 5.0 mm below the optimal position, was then intentionally increased every 25.4 mm of wall length by an amount of 1.0 mm to a final position 7.0 mm above optimal. Computer vision is demonstrated to monitor the amount of focus in each color band and estimate standoff distance. Finally, a response can be calculated in under 40 ms using simple hardware and can work in most laser-based DED systems.

36 MATERIALS SCIENCE↗

Scaling Individual Tree Transpiration With Thermal Cameras Reveals Interspecies Differences to Drought Vulnerability

Abstract Understanding tree transpiration variability is vital for assessing ecosystem water‐use efficiency and forest health amid climate change, yet most landscape‐level measurements do not differentiate individual trees. Using canopy temperature data from thermal cameras, we estimated the transpiration rates of individual trees at Harvard Forest and Niwot Ridge. PT‐JPL model was used to derive latent heat flux from thermal images at the canopy‐level, showing strong agreement with tower measurements ( R 2 = 0.70–0.96 at Niwot, 0.59–0.78 at Harvard at half‐hourly to monthly scales) and daily RMSE of 33.5 W/m 2 (Niwot) and 52.8 W/m 2 (Harvard). Tree‐level analysis revealed species‐specific responses to drought, with lodgepole pine exhibiting greater tolerance than Engelmann spruce at Niwot and red oak showing heightened resistance than red maple at Harvard. These findings show how ecophysiological differences between species result in varying responses to drought and demonstrate that these responses can be characterized by deriving transpiration from crown temperature measurements.

Javadian, Mostafa↗

Enhanced anti-counterfeiting measures for additive manufacturing: coupling lanthanide nanomaterial chemical signatures with blockchain technology

The significant rise of additive manufacturing (AM) in recent years is in part due to the open sourced nature of the printing processes and reduced cost and capital barriers relative to traditional manufacturing. However, this democratization of manufacturing spurs an increased demand for producers and end-users to verify the authenticity and quality of individual parts. To this end, we introduce an anti-counterfeiting method composed of first embedding engineered nanomaterials into features of a 3D-printed part followed by non-destructive interrogation of these features to quantify a chemical signature profile. The part specific chemical signature data is then linked to a securitized, distributed, and time-stamped blockchain ledger entry. To demonstrate the utility of this approach, lanthanide-aspartic acid nanoscale coordination polymers (Ln3+- Asp NCs) / poly(lactic) acid (PLA) composites were formulated and transformed into a filament feedstock for fused deposition modeling (FDM) 3D printing. In the present case, a quick-response (QR) code containing the doped Ln3+-Asp NCs was printed using a dual-extruder FDM printer into pure PLA parts. The QR code provides a searchable reference to an Ethereum-based blockchain entry. The QR code physical features also serve as defined areas to probe the signatures arising from the embedded Ln3+-Asp NCs. Visible fluorescence emission with UV-excitation was quantified in terms of color using a smartphone camera and incorporated into blockchain entries. Ultimately, linking unique chemical signature data to blockchain databases is anticipated to make the costs of counterfeiting AM materials significantly more prohibitive and transactions between those in the supply chain more trustworthy.

Additive Manufacturing↗

Long range surface plasmon resonance with ultra-high penetration depth for self-referenced sensing and ultra-low detection limit using diverging beam approach

Using an insulator-metal-insulator structure with dielectric having refractive index (RI) larger than the analyte, long range surface plasmon (SP) resonance exhibiting ultra-high penetration depth is demonstrated for sensing applications of large bioentities at wavelengths in the visible range. Based on the diverging beam approach in Kretschmann-Raether configuration, one of the SP resonances is shown to shift in response to changes in the analyte RI while the other is fixed; thus, it can be used as a built in reference. The combination of the high sensitivity, high penetration depth and self-reference using the diverging beam approach in which a dark line is detected of the high sensitivity, high penetration depth, self-reference, and the diverging beam approach in which a dark line is detected using large number of camera pixels with a smart algorithm for sub-pixel resolution, a sensor with ultra-low detection limit is demonstrated suitable for large bioentities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IPL Processing of the Viking Orbiter Images of Mars

The Viking orbiter cameras returned over 9000 images of Mars during the 6-month nominal mission. Digital image processing was required to produce products suitable for quantitative and qualitative scientific interpretation. Processing included the production of surface elevation data using computer stereophotogrammetric techniques, crater classification based on geomorphological characteristics, and the generation of color products using multiple black-and-white images recorded through spectral filters. The Image Processing Laboratory of the Jet Propulsion Laboratory was responsible for the design, development, and application of the software required to produce these 'second-order' products.

Ruiz, R. M.↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗