Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Meta‐Analysis and Regression Modeling of the Impacts of Four Indoor Environmental Quality Metrics on Office Performance

Awareness of how buildings interact with the occupant experience—especially human performance—is becoming more prevalent, as seen by increasing interest and investment in healthy built environments. However, there is a need to synthesize the wide array of existing indoor environmental assessment and performance research in a way that can translate directly to building design and operation. Existing research in this area typically focuses on a single isolated metric and has not focused on making the results utilizable by building practitioners. The aim of this research is to investigate existing office performance literature through meta‐analyses and produce regression models for four indoor environmental quality (IEQ) metrics to support critical decision‐making for building operation and renovation. To reach this aim, a literature review was conducted to identify studies that measure the impact of changing ventilation rate, temperature, horizontal illuminance, and noise level in offices on occupant task performance. This repository of field and laboratory studies was analyzed to visualize the trends between the selected IEQ metrics and task performance. The temperature, ventilation rate, and horizontal illuminance regression models showed clear improvement potential when modifying indoor conditions toward the defined high‐performance range, while the regression model for noise level was inconclusive. The discussion notes the importance of designing holistically for all components of these IEQ categories to utilize the results, for example, good filtration on outdoor air for quantifying ventilation impact and uniform overhead lighting with low contrast for quantifying horizontal illuminance impact. The novelty of this work is in considering multiple facets of the indoor environment under a single, unified analysis schema and producing IEQ‐based performance gains that can directly inform cost‐benefit analyses of building design and renovation.

60 APPLIED LIFE SCIENCES↗

Improving Residential Building Simulations Through Large-Scale Empirical Validation

Residential building energy simulations are increasingly used for energy-efficient building design, codes and standards analysis, home certifications and ratings, utility programs, and technology assessments. Various software tools exist to perform residential building simulations, and these tools often use different models, inputs, and assumptions. This leads to inconsistencies that can undermine confidence in the predicted results. Validation of these tools can increase confidence by ensuring their accuracy and consistency. One way to validate simulation tools is through empirical testing, which compares predicted energy usage to measured utility billing data. This paper describes the process of data collection, data standardization, and empirical validation, and illustrates its use with our residential EnergyPlus (R)-based software. The data and process can be extended to other simulation tools and contribute to improving residential building simulations more broadly.

empirical validation↗

Empirical validation and comparison of methodologies to simulate micro and macro-encapsulated PCMs in the building envelope

Thermal Energy Storage (TES) has the potential to shift peak electricity demand. Passive TES is usually implemented in building envelope as micro and macro encapsulated phase change materials (PCM) to shift electric energy demand and therefore requires careful heat transfer analysis. Whole building energy modelling with simplified heat transfer analysis has become extremely important for designers, architects, engineers, and researchers to predict energy performance of buildings. It is important to validate PCM modelling algorithms used in building energy programs to quantify their error and prove their capacity to model different PCM encapsulation types. This study uses data from a microencapsulated PCM and two macroencapsulated PCMs (Bio based PCM and hydrate salts) tested in full-scale using the Advanced Multiscale Building Energy Research (AMBER) Lab located at the Colorado School of Mines and is used to validate a numerical algorithm written in MATLAB language. To approximate the heat transfer through a wall assembly with macroencapsulated PCM pouches, several modelling techniques that can reduce 3D heat transfer characteristics to 1D are explored in this research. A parallel path heat transfer modelling approach is found to give the closest agreement with the experimental data for the pouched PCMs in building envelope applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Urban building energy modeling (UBEM) tools: A state-of-the-art review of bottom-up physics-based approaches

Regulations corroborate the importance of retrofitting existing building stocks or constructing new energy-efficient districts. There is, thus, a need for modeling tools to evaluate energy scenarios to better manage and design cities, and numerous methodologies and tools have been developed. Among them, Urban Building Energy Modelling (UBEM) tools allow the energy simulation of buildings at large scales. Choosing an appropriate UBEM tool, balancing the level of complexity, accuracy, usability, and computing needs, remains a challenge for users. The review focuses on the main bottom-up physics-based UBEM tools, comparing them from a user-oriented perspective. Five categories are used: (i) the required inputs, (ii) the reported outputs, (iii) the exploited workflow, (iv) the applicability of each tool, and (v) the potential users. Moreover, a critical discussion is proposed, focusing on interests and trends in research and development. The results highlighted major differences between UBEM tools that must be considered to choose the proper one for an application. Finally, barriers of adoption of UBEM tools include the needs of a standardized ontology, a common three-dimensional city model, a standard procedure to collect data, and a standard set of test cases. This feeds into future development of UBEM tools to support cities’ sustainability goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Unified Taxonomy for HVAC System Faults

Detecting and diagnosing HVAC faults is critical for maintaining building operation performance, reducing energy waste, and ensuring indoor comfort. An increasing deployment of commercial fault detection and diagnostics (FDD) software tools in commercial buildings in the past decade has significantly increased buildings’ operational reliability and reduced energy consumption. A massive amount of data has been generated by the FDD software tools. However, efficiently utilizing FDD data for ‘big data’ analytics, algorithm improvement, and other data-driven applications is challenging because the format and naming conventions of those data are very customized, unstructured, and hard to interpret. This paper presents the development of a unified taxonomy for HVAC faults. A taxonomy is an orderly classification of HVAC faults according to their characteristics and causal relations. The taxonomy includes fault categorization, physical hierarchy, fault library, relation model, and naming/tagging scheme. The taxonomy employs both a physical hierarchy of HVAC equipment and a cause-effect relationship model to reveal the root causes of faults in HVAC systems. A structured and standardized vocabulary library is developed to increase data representability and interpretability. The developed fault taxonomy can be used for HVAC system ‘big data’ analytics such as HVAC system fault prevalence analysis or the development of an HVAC FDD software standard. A common type of HVAC equipment-packaged rooftop unit (RTU) is used as an example to demonstrate the application of the developed fault taxonomy. Two RTU FDD software tools are used to show that after mapping FDD data according to the taxonomy, the meta-analysis of the multiple FDD reports is possible and efficient.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

I/O Parallelization for the Goddard Earth Observing System Data Assimilation System (GEOS DAS)

The National Aeronautics and Space Administration (NASA) Data Assimilation Office (DAO) at the Goddard Space Flight Center (GSFC) has developed the GEOS DAS, a data assimilation system that provides production support for NASA missions and will support NASA's Earth Observing System (EOS) in the coming years. The DAO's support of the EOS project along with the requirement of producing long-term reanalysis datasets with an unvarying system levy a large I/O burden on the future system. The DAO has been involved in prototyping parallel implementations of the GEOS DAS for a number of years and is now converting the production version from shared-memory parallelism to distributed-memory parallelism using the portable Message-Passing Interface (MPI). If the MPI-based GEOS DAS is to meet these production requirements, we must make I/O from the parallel system efficient. We have designed a scheme that allows efficient I/O processing while retaining portability, reducing the need for post-processing, and producing data formats that are required by our users, both internal and external. The first phase of the GEOS DAS Parallel I/O System (GPIOS) will expand upon the common method of gathering global data to a Single PE for output. Instead of using a PE also tasked with primary computation, a number of PEs will be dedicated to I/O and its related tasks. This allows the data transformations and formatting required prior to output to take place asynchronously with respect to the GEOS DAS assimilation cycle, improving performance and generating output data sets in a format convenient for our users. I/O PEs can be added as needed to handle larger data volumes or to meet user file specifications. We will show I/O performance results from a prototype MPI GCM integrated with GPIOS. Phase two of GPIOS development will examine ways of integrating new software technologies to further improve performance and build scalability into the system. The maturing of MPI-IO implementations and other supporting libraries such as parallel HDF should provide performance gains while retaining portability.

Lucchesi, R.↗

Tackling the Giants: Applying Smart Labs Principles to Constant Air Volume Lab Buildings

Laboratories typically consume 3 to 10 times more energy than similarly sized commercial buildings, and as much as 50% of that energy is wasted by inefficient and poorly operating fume hoods and ventilation systems. One challenge faced by older laboratory buildings is the heating, ventilation, and air-conditioning systems serving many of these buildings. The older systems are usually constant air volume (CAV) systems that maintain constant ventilation rates that cause excess airflow and inefficient energy use. Variable air volume systems can be more efficient systems with sensors to detect the need for a change in volumetric flow rate; however; renovation of ventilation systems can create disruption to ongoing research and operations along with considerable up-front costs. When a Smart Labs program is implemented, an organization has a systems-based management approach that yields a high-performing laboratory building. As decarbonization continues as a priority for sites, buildings with CAV systems are difficult to address. This work centers around practical guidance for improving lab buildings with CAV. In conjunction with industry input on top technology solutions and best practices, recommendations will include performing a laboratory ventilation risk assessment in conjunction with robust retro-commissioning work, which is a crucial step in the Smart Lab process. By applying Smart Labs principles, the aging laboratory building stock of 153,343 (Lawrence Berkeley National Laboratory [LBNL] 2017), comprising roughly 500,000 lab spaces in the United States, can be brought to safe and high-performance operations.

building↗

Optimized finite-build stellarator coils using automatic differentiation

A new stellarator coil design code is introduced that optimizes the position and winding pack orientation of finite-build coils. The new code, called flexible optimized curves in space using automatic differentiation (AD) and finite build (FOCUSADD), performs gradient-based optimization in a high-dimensional, non-convex space. The derivatives with respect to parameters of finite-build coils are easily and efficiently computed using AD. FOCUSADD parametrizes coil positions in free space using a Fourier series and uses a multi-filament approximation to the coil winding pack. The orientation of the winding pack is parametrized with a Fourier series and can be optimized as well. Optimized finite-build coils for a Wendelstein 7-X (W7-X)-like stellarator are found, and compared with filamentary coil results. The final positions of optimized finite-build W7-X-like coils are shifted, on average, by approximately 2.5 mm relative to optimized filamentary coils. These results suggest that finite-build effects should be accounted for in the optimization of stellarators with low coil tolerances.

43 PARTICLE ACCELERATORS↗

Coupled Induction Machine and HVAC Models for Simulating HVAC Performance Considering Grid Dynamics in Buildings

This paper presents the development of novel models that integrate induction machines with HVAC equipment, such as pumps, heat pumps, and chillers, to analyze the impact of electrical parameters on the operational performance of thermo-fluid systems. The proposed model employs a coupling technique that captures the dynamic interactions between induction machines and HVAC systems. By integrating electrical, thermal, and mechanical dynamics, the models provide a comprehensive framework for simulating real-world scenarios, including interactions with the electrical grid. This achievement was made possible through the development of a Computationally Efficient and Accurate Induction Machine (CEAIM) model. Implemented using the equation-based Modelica language, the CEAIM model has been validated against experimental results, manufacturer data sheets, and various operating conditions. Its performance has been compared with existing induction machine models in the Modelica Standard Library (MSL), demonstrating superior accuracy and computational efficiency. The CEAIM model predicts torque, speed, and power consumption with a coefficient of determination (R 2 ) ranging from 0.98 to 1 and a coefficient of variation of root mean square error (CVRMSE) between 0.27% and 6.67%. Additionally, CEAIM scales more efficiently than conventional MSL models, with a slower computational growth rate in large-scale simulations. After thorough validation of the CEAIM model, it was coupled with HVAC equipment as this approach provides a detailed multi-dimensional view of capturing electrical transients and mechanical performance. To support this, a case study was conducted to showcase its capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercial Building Energy Baseline Modeling Software: Performance Metrics and Method Testing with Open Source Models and Implications for Proprietary Software Testing

The overarching goal of this work is to advance the capabilities of technology evaluators in evaluating the building-level baseline modeling capabilities of Energy Management and Information System (EMIS) software. Through their customer engagement platforms and products, EMIS software products have the potential to produce whole-building energy savings through multiple strategies: building system operation improvements, equipment efficiency upgrades and replacements, and inducement of behavioral change among the occupants and operations personnel. Some offerings may also automate the quantification of whole-building energy savings, relative to a baseline period, using empirical models that relate energy consumption to key influencing parameters, such as ambient weather conditions and building operation schedule. These automated baseline models can be used to streamline the whole-building measurement and verification (M&V) process, and therefore are of critical importance in the context of multi-measure whole-building focused utility efficiency programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cybersecurity Considerations and Research Pathways for Grid-Interactive Efficient Buildings

Federal facilities serve critical missions and functions that require safe, reliable, and efficient operations. Digitization of several facility operations has increased the cost-effectiveness of energy usage and optimization of energy system performance. As the building controls landscape shifts to become more connected and smarter, building operators now face unique opportunities and challenges to adopt smart enabled devices that can lower energy usage while also optimizing building system performance. The grid-interactive efficient buildings (GEB) initiative aims to make buildings cleaner and more flexible through these smart devices. Smart enabled devices allow greater connectivity and control through remote operations and provide crucial data for analytics and increased efficiency. GEBs enable demand flexibility that has the potential to reduce electrical costs and transform the grid edge where buildings connect to power grids. This operation of interconnected systems, if not designed with cybersecurity practices, causes security gaps and introduces potential attack paths by adversarial and non-adversarial entities leading to disruption of operations.

building controls↗

De novo atomic protein structure modeling for cryoEM density maps using 3D transformer and HMM

Accurately building 3D atomic structures from cryo-EM density maps is a crucial step in cryo-EM-based protein structure determination. Converting density maps into 3D atomic structures for proteins lacking accurate homologous or predicted structures as templates remains a significant challenge. Here, we introduce Cryo2Struct, a fully automated de novo cryo-EM structure modeling method. Cryo2Struct utilizes a 3D transformer to identify atoms and amino acid types in cryo-EM density maps, followed by an innovative Hidden Markov Model (HMM) to connect predicted atoms and build protein backbone structures. Cryo2Struct produces substantially more accurate and complete protein structural models than the widely used ab initio method Phenix. Additionally, its performance in building atomic structural models is robust against changes in the resolution of density maps and the size of protein structures.

59 BASIC BIOLOGICAL SCIENCES↗

The Walls Come Tumbling Down: Decontamination and Demolition of 29 Manhattan Project and Cold War-Era Buildings and Structures at Los Alamos National Laboratory-12301

When the nation's top scientists and military leaders converged on Los Alamos, New Mexico in the 1943, to work on the Manhattan Project, the facilities they used to conduct their top-secret work were quickly constructed and located in the middle of what eventually became the Los Alamos town site. After one of these early facilities caught on fire, it seemed wise to build labs and production facilities farther away from the homes of the town's residents. They chose to build facilities on what was then known as Delta Prime (DP) Mesa and called it Technical Area 21, or TA-21. With wartime urgency, a number of buildings were built at TA-21, some in as little as a few months. Before long, DP Mesa was populated with several nondescript metal and cinder-block buildings, including what became, immediately following the war, the world's first plutonium production facility. TA-21 also housed labs that used hazardous chemicals and analyzed americium, tritium and plutonium. TA-21 was a bustling center of research and production for the next several decades. Additional buildings were built there in the 1960's, but by the 1990's many of them had reached the end of their service lives. Labs and offices were moved to newer, more modern buildings. When Los Alamos National Laboratory received $212 million in funding from the American Recovery and Reinvestment Act in July 2009 for environmental cleanup projects, about $73 million of the funds were earmarked to decontaminate and demolish 21 of the old buildings at TA-21. Although some D and D of TA-21 buildings was performed in the 1990's, many of the facilities at DP Site remained relatively untouched for nearly three decades following their final operational use. In 2006, there were over three dozen buildings or structures on the mesa to be removed so that soil cleanup could be completed (and the land made available for transfer and reuse). The total footprint of buildings across the mesa was approximately 18,580 m{sup 2} (200,000 ft{sup 2}). The initially approved baseline for the ARRA D and D Project was to remove 22 buildings and structures that included approximately 14,680 m{sup 2} (158,000 ft{sup 2}) of footprint. By employing efficiencies during subcontracting, demolition, and waste segregation, the savings allowed an additional 1,580 m{sup 2} (17,000 ft{sup 2}) of footprint to be removed using ARRA funds. Additionally, the lessons learned from this experience were used to apply NNSA funding to the removal of six additional non-contaminated buildings and structures. In the end, 29 buildings and structures, including stacks, cooling towers and tanks, were removed from the mesa. The entire DP East area was cleared of buildings and sub-grade structures and the soils cleaned to residential standards. The total footprint reduction at TA-21 as a result of this effort was in excess of 17,650 m{sup 2} (190,000 ft{sup 2}). The use of a Laboratory self-performance team to start demolition of non-contaminated structures resulted in steady work performance early in the project while subcontracts were being put in place to perform more complicated abatement and contaminated demolition activities. Most importantly, there were no serious worker injuries and the minor injuries recorded were those common to construction type activities. Extensive monitoring along the site boundary demonstrated that no hazardous chemicals or radioactive contamination were released and radiological dose to the public was negligible. The ARRA demolition activities were completed six months in advance of the deadline for employing ARRA funds. Additionally, over 17,585 m{sup 3} (23,000 yds{sup 3}) of building demolition debris was safely removed from DP Mesa. All of the major buildings have been removed, unencumbered access to the SWMUs that are required to be cleaned up by the Consent Order with the state of New Mexico, has been achieved, and a significant portion of the mesa has been prepared to support a process that will eventually transfer this land from federal government control for further use. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Energy Design Guide K-12: Next Generation of School Design and Operation

Driven by energy efficiency advances and renewable energy cost reductions, zero energy buildings are popping up all around the country. Although zero energy represents a bold paradigm shift - from buildings that consume energy to buildings that produce enough energy to meet their energy needs on an annual basis - it isn't a sudden shift. Zero energy buildings are the result of steady, incremental progress by researchers and building professionals working together to improve building energy performance. ASHRAE is taking the lead by publishing - in partnership with the American Institute of Architects (AIA), the Illuminating Engineering Society (IES), the U.S. Green Building Council (USGBC), and the U.S. Department of Energy (DOE) - a new series of advanced energy design guides (AEDGs) focused on zero energy buildings. The recently completed Advanced Energy Design Guide for K-12 School Buildings: Achieving Zero Energy (K-12 ZE AEDG) is the first in this series.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Large-Scale Daylighting Analysis for Buildings, Products, and Policy

Daylighting in buildings has come under increased scorn in the wake of ubiquitous solid-state lighting (SSL), as installed lighting power densities in buildings have been reduced to the point where designers and owners question the benefits of properly-designed daylighting and electric lighting control. At the same time the very process of demonstrating well-executed daylighting to satisfy new building rating systems has become burdensome. This paper demonstrates the utility of illuminance as an input to simple, existing qualitative and quantitative metrics for daylighting performance in buildings, at scale. This assertion is supported by sensitivity analysis of a large-scale daylighting simulation dataset. Uses of this data for quantifying non-energy benefits (NEBs) of daylighting are also explored. We do not eschew the use of newer, more detailed daylight metrics in design, but we do encourage the use of simple daylight metrics for a broader range of new and retrofit building projects toward a net-zero future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of predictive data analytics to model daily hydrocarbon production using petrophysical, geomechanical, fiber-optic, completions, and surface data: A case study from the Marcellus Shale, North America

Predicting gas production from stimulated unconventional reservoirs has always been a challenge to oil and gas companies because the physics of fluid flow through such reservoirs is not well understood. On the other hand, modeling gas production from shale reservoirs is a complex multi-variate problem that requires proper integration of data from multiple disciplines, such as geology, petrophysics, geomechanics, completions, and surface-based measurements, etc. Here this study demonstrates the application of data-driven machine learning algorithms, integrating geoscientific, distributed acoustic sensing (DAS), distributed temperature sensing (DTS) fiber-optic, completions, flow scanner production log, and surface data to model daily gas production from a 28-stage stimulated horizontal well drilled in the Marcellus Shale of the Appalachian basin in North America. In addition, this study aims to utilize the data from a fiber-optic monitoring system, such as DAS and DTS to evaluate the well performance. We build supervised data-driven machine learning models using Random Forest (RF), Artificial Neural Network (ANN), and Support Vector Machine (SVM) algorithms to understand the well performance and forecast the daily gas production. The study compares the forecasted results, tests the level of accuracy, and addresses different issues with these machine learning algorithms. A spatio-temporal database is constructed and used to perform sensitivity analyses to identify the key drivers for gas production. The results show that RF and ANN algorithms can be used to predict daily gas production with significantly high accuracy; however, RF algorithm is the best predictor in terms of highest accuracy (96%), less computational time and cost. Based on sensitivity analysis, it appears that Poisson's ratio, minimum horizontal stress, DAS, casing pressure, gamma log are the most important parameters to predict gas production.

02 PETROLEUM↗

Configuring and Testing Mesh Radios for Air-To-Ground Communications

The initial mesh network used to demonstrate a simple mesh network for the air-to-ground challenge will consist of 4 mesh radios purchased from DoodleLabs. The multiband radios operate in both the 915MHz and 2450MHz frequencies and can use Wi-Fi to connect to deployed devices. The DoodleLabs radios come preconfigured with unique IP addresses but to make sure of compatibility each radio will be assigned an IP address. For initial testing configurations will be changed using the built-in local web server interface that DoodleLabs radios provide. To access the webserver a computer connects to the radios broadcast Wi-Fi network using the default credentials, then enter the default IP address into a browser. This webserver will allow the user to monitor the radio performance and make changes to the various systems. The simple configuration page will allow an operator to make many of the initial changes to place each radio on the network and secure each connection with a new password. Further testing will then be performed by building out a simulated virtual network of 26 nodes and connecting the 4 DoodleLabs radios into this simulation. This will give insight into the radio’s performance in the larger system they will likely operate in given the project requirements. This testing will focus on multi-hop throughput, latency and the resiliency to packet loss.

Mesh Radio↗