Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Cloud-Control of Legacy Building Automation System: A case study

As Internet of Things devices and cloud-based platforms become more mature, Energy Management and Information Systems (EMIS) are increasingly gaining momentum in the building industry. In large commercial buildings, Fault-Detection and Diagnostic (FDD) and energy information systems (EIS) are now established technologies with tens of providers and thousands of deployment sites across North America. The new frontier for the EMIS technology is now represented by control systems that use advanced system optimization (ASO) methods to improve the operations of the HVAC system. Given the complexity of the integration of such systems with the existing building automation systems (BAS) and the higher risk involved with direct control of the HVAC, these systems are still emerging in the market. This paper presents the results of a project in which a start-up company partnered with a research institution to develop a cloud-based software EMIS solution and deployed it in a university campus in California. The software system included advanced sensing, data acquisition, storage and advanced control and analytics applications developed on top of the native BAS. The new platform controls ten buildings on the campus and the FDD and the ASO applications deployed on this platform were able to generate energy savings of up to 35% and 25% in certain buildings for each functionality respectively. Where the platform did not save energy, it improved building service (air quality). Lessons learned include the importance of collaborating with and training the building operators and evaluating whether the legacy system can work reliably with the new technology.

Prakash, Anand Krishnan↗

Energy cost savings and expected payback for Re-tuning the controls of US Army buildings

The Headquarters Department of the Army (HQDA) sponsored a study to determine the national impact of deploying the Re-tuning™ methodology in 5 buildings types that account for over 40% of the Army’s conditioned building stock. Re-tuning is a systematic process that improves operational efficiency and reduces energy consumption at no- or low-cost through the building automation system (BAS) by correcting operational problems that plague buildings. The study relied on successful demonstration of the re-tuning methodology at 4 pilot US Army installations that informed a holistic effort that included simulating 12 individual re-tuning energy efficiency measures (EEMs) and 6 packages of EEMs in 5 selected Army building prototype models that represent 311 million ft2 (28.9 million m2) of the Army’s conditioned floor space. Both the baseline buildings and the packages were customized to capture the expected outcomes of re-tuning a diverse set of buildings. The study highlighted the benefit of individual re-tuning EEMs and economics of implementing packages of EEMs in applicable Army buildings across 16 climates and 2 building vintages. The average whole-building energy savings ranged from 10.8% to 40.5% by building type, with the company operations facility (COF) building having the highest value proposition from re-tuning. In addition, the study reveals that all large office (LO) buildings in the Army are economical to re-tune. The total modeled cost savings potential for re-tuning the five building types across the US Army is $204/1,000 sf ($220/100 m2), or $64M annually. This cost savings represents 5.6% of all the Army’s energy expenditures.

Fernandez, Nicholas EP↗

EOS: A project to investigate the design and construction of real-time distributed Embedded Operating Systems

Project EOS is studying the problems of building adaptable real-time embedded operating systems for the scientific missions of NASA. Choices (A Class Hierarchical Open Interface for Custom Embedded Systems) is an operating system designed and built by Project EOS to address the following specific issues: the software architecture for adaptable embedded parallel operating systems, the achievement of high-performance and real-time operation, the simplification of interprocess communications, the isolation of operating system mechanisms from one another, and the separation of mechanisms from policy decisions. Choices is written in C++ and runs on a ten processor Encore Multimax. The system is intended for use in constructing specialized computer applications and research on advanced operating system features including fault tolerance and parallelism.

Campbell, R. H.↗

Control of Behind-the-Meter Resources for Enhancing the Resilience of Residential Buildings

There is increased concern about the impacts of frequent power outages, caused primarily by extreme weather conditions. With increasing behind-the-meter resources such as solar photovoltaics (PV), battery energy storage, and controllable loads, these resources - if properly coordinated - can meet critical loads even during an outage. Resilience building controls can coordinate and operate these resources to enhance the resiliency of buildings supporting critical loads for longer duration. In this paper, we present two resilience building controls: rule-based control and model predictive control (MPC). We simulated various scenarios considering different locations, seasons, outage types, and times of outages to evaluate the performance of resilience controls. The results show that MPC-based control can enhance resilience up to 65% compared to rule-based control. Similarly, PV self-consumption and occupant thermal comfort both increase during outages with MPC-based control.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Advancing Construction through the Buildings Workforce: Preprint

Buildings are America's energy hogs, consuming over 70 percent of all electricity and over 50 percent of all natural gas produced across the country. Achieving a clean energy future requires us to reinvent how buildings manage energy resources and how consumers demand it. The U.S. Department of Energy is investing in a range of technological advancements that are paving the way to a future where buildings are no longer simply energy consumers, but rather are part of an integrated system that help manage energy resources in a way that supports the electricity grid. This paradigm shift presents an opportunity to increase the efficiency of the built environment, but will only be realized if we build a knowledgeable workforce to design, construct, and operate these high-performance buildings in step with the rate of technological advancement.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Energy Saver Called NECAP

One of the most comprehensive and most effective programs is NECAP, an acronym for NASA Energy Cost Analysis Program. Developed by Langley Research Center, NECAP operates according to heating/cooling calculation procedures formulated by the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE). The program enables examination of a multitude of influences on heat flow into and out of buildings. For example, NECAP considers traditional weather patterns for a given locale and predicts the effects on a particular building design of sun, rain, wind, even shadows from other buildings. It takes into account the mass of structural materials, insulating values, the type of equipment the building will house, equipment operating schedules, heat by people and machinery, heat loss or gain through windows and other openings and a variety of additional details. NECAP ascertains how much energy the building should require ideally, aids selection of the most economical and most efficient energy systems and suggests design and operational measures for reducing the building's energy needs. Most importantly, NECAP determines cost effectiveness- whether an energy-saving measure will pay back its installation cost through monetary savings in energy bills. thrown off

Source record↗

Grey-box and ANN-based building models for multistep-ahead prediction of indoor temperature to implement model predictive control

Model-based predictive control (MPC) strategies for heating, ventilation, and air-conditioning (HVAC) systems present an opportunity to lower building energy consumption and operational costs. Such approaches rely on the development of a model to precisely forecast building thermal dynamics, such as room air temperature or heating/cooling rate, and make control-related decisions. The control-oriented modeling of building energy systems should be accurate in predicting indoor conditions and present low computational complexity. These features are the key challenge of implementing advanced control methods such as MPC. Extant studies on building modeling for MPC have focused on step-ahead forecasting techniques to forecast building thermal dynamics, while multistep-ahead forecasting is essential. Moreover, machine learning model suitable in case of the domain-based engineering expertise are also not available. To this aim, we perform a comparative analysis of the grey-box model based on a resistance-capacitance (RC) thermal network and a machine learning model composed of an artificial neural network (ANN) for multistep-ahead prediction of building thermal dynamics using current and historical data. Actual experimental data obtained from the Flexible Research Platform (FRP) in Oak Ridge National Laboratory (US) are used for estimation and validation purposes. The average root mean squared error (RMSE) of the grey-box and ANN models are 0.89 °C and 1.02°C, respectively. Finally, the results indicate that the grey-box model outperforms the ANN model in the considered validation periods in terms of accuracy and prediction stability.

42 ENGINEERING↗

Converting CSV Files to RKSML Files

A computer program converts, into a format suitable for processing on Earth, files of downlinked telemetric data pertaining to the operation of the Instrument Deployment Device (IDD), which is a robot arm on either of the Mars Explorer Rovers (MERs). The raw downlinked data files are in comma-separated- value (CSV) format. The present program converts the files into Rover Kinematics State Markup Language (RKSML), which is an Extensible Markup Language (XML) format that facilitates representation of operations of the IDD and enables analysis of the operations by means of the Rover Sequencing Validation Program (RSVP), which is used to build sequences of commanded operations for the MERs. After conversion by means of the present program, the downlinked data can be processed by RSVP, enabling the MER downlink operations team to play back the actual IDD activity represented by the telemetric data against the planned IDD activity. Thus, the present program enhances the diagnosis of anomalies that manifest themselves as differences between actual and planned IDD activities.

Trebi-Ollennu, Ashitey↗

Review of data-driven models for quantifying load shed by non-residential buildings in the United States

Shifting and shedding power demand in buildings can be cost-effective techniques for grids to function reliably and for end users to earn compensation. Grid operators reimburse customers in proportion to the quantity of load shed. Simple data-driven methods are used to quantify this shed, which is the difference between a measured load during the event and modeled "baseline" that would have occurred in absence of the event. These methods have evolved over the years and in many cases have been integrated with building physics, to make them a hybrid between physics based and empirical models. However, there is no comprehensive analysis that provides guidance to building operators, grid operators and researchers in selecting appropriate models based on their specific needs and available data. Here, this work aims to fill this gap by critically assessing the performance of baseline models put forward from the year 2000 through 2023. The literature reviewed includes reports generated by grid operators, reports from national laboratories and academic journal articles. The work outlines modeling features like the inputs, training period, estimation method, adjustments to fine tune the predictions and metrics to evaluate the performance. A comprehensive list of 50 models has been provided. For each model, the study explores the applicability of the model to weather sensitive buildings, variability in the building profile, timing of the event, and whether the building reduces energy consumption before an event. The work identifies the situations in which a particular model works and draws lessons based on evidence of performance. Finally, recommendations to aid in model selection are given.

97 MATHEMATICS AND COMPUTING↗

Tier 2 Safety Basis Document: Weapons and Complex Integration - Building 225

This Safety Basis Document (SBD) covers operations in the Weapons and Complex Integration (WCI) Building 225 (B225) facility. B225 is located in the southwestern quadrant of Lawrence Livermore National Laboratory (LLNL) and is operated and owned by WCI. This SBD satisfies the requirements of LLNL ES&H Manual Document 3.1, Nonnuclear Safety Basis Program (Ref. 2). B225 is classified as a Low Hazard Facility based on the inventory of radiological materials. Other hazards in B225: chemicals, radiation generating devices, and industrial hazards are managed at the Light Science and Industry (LSI) level. Biological and explosive hazards are not authorized in B225. There are four general Administrative Controls (ACs) identified as the B225 Operational Safety Requirements (OSRs). These administrative controls are deemed sufficient to ensure safe operations with respect to co-located workers and the public. Other safety features and administrative requirements are required by the LLNL ES&H Manual, including those to protect the facility workers and the environment, but these have not been selected as credited controls to protect the co-located workers or the public, which are the target populations of concern for the SBD.

61 RADIATION PROTECTION AND DOSIMETRY↗

Operation and performance of VRF systems: Mining a large-scale dataset

The energy consumption of air-conditioning systems has gained increasing attention as it contributes significantly to the global building energy use. The variable refrigerant flow (VRF) system is a common air-conditioning system applied widely in residential and office buildings in China. Understanding the actual operation and performance of VRF systems is fundamental for the energy-efficient design and operation of VRF systems. Previous research on VRF system operation used either limited field data covering certain building types and climate zones or used a questionnaire to obtain a larger dataset. However, they did not capture the wide applications of VRF systems quantitatively across all building types, climate zones, and operating conditions. To fill this gap, statistical and clustering analysis was conducted on the newly proposed key performance indicators of approximately 287,000 VRF systems for residential and commercial buildings in all five climate zones in China. In this work, the main findings are: (1) VRF systems are mainly used for cooling in all climate zones in China; (2) among all building types, the duration of use is lowest in residential buildings and highest in hotels and medical buildings; (3) the distribution of the ideal VRF cooling coefficient of performance (COP) is similar across all climate zones and building types; whereas the COPs of ideal VRF heating in the Severe Cold region and Cold regions are lower than those in other climate zones; and (4) partial load operations for VRF systems are common in residential buildings and office buildings due to the part-time-part-space operation mode. These findings can inform the actual application of VRF systems in China, supporting the design, operation, industry standard development, and performance optimization of VRF systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗

Modeling Spacecraft Safe Mode Events

Spacecraft enter a ‘safe mode’ to protect the vehicle when a potentially harmful anomaly occurs. This minimally functioning state isolates faults, establishes contact with Earth, and orients the vehicle into a power positive attitude until operators intervene. Though ‘safings’ are inherently unpredictable, mission teams build in time margin during operations to determine root causes and restore functionality. Planning and managing this margin is both critical and enabling on mission architectures dependent on near-continuous operability – such as a low-thrust electric propulsion mission. To better quantify the occurrences and severity of safe mode anomalies, the Jet Propulsion Laboratory (JPL) has assembled a database of safings from past and active missions. Currently nearly 240 records are captured from 21 beyond-Earth missions, stemming from a collaboration between teams at JPL, Ames Research Center, Goddard Space Flight Center, and the Johns Hopkins University Applied Physics Laboratory. This paper discusses the event database, explores a statistical approach in modeling the occurrences and severity of safing events, presents a simulation technique, and details recommendations and future work to benefit future concepts.

Nicholas, Austin↗

Developing an Unmanned Aircraft System Pilot (UASP-kit) for Wildland Fire UAS Operators

The use of unmanned aircraft systems (UAS) to support disaster management is becoming more widespread. Uninhibited by many of the operational constraints imposed on crewed aircraft, UAS have the potential to augment the aerial response in a number of ways, including supporting situation awareness, thereby accelerating disaster management efforts. The intent of the Scalable Traffic management for Emergency Response Operations (STEReO) activity is to build an ecosystem that will allow small UAS (sUAS) operations to fly safely in the airspace during disaster management events. The first step toward this goal is to develop a small, single-user tool (the UASP-kit) that will enhance an sUAS pilot’s situation awareness of the airspace. User needs for the functions and features of this tool were collected during a walkthrough over multiple days with subject matter experts from the US Forest Service. A prototype of the UASP-kit was then taken on an extended demonstration to multiple users, who were able to interact with it. User feedback was largely positive and users discussed the information they needed to support situation awareness in context. The demonstration also highlighted features that were unintuitive to use, and functions that need to be modified to make the kit more user-friendly and robust.

STEReO↗

Developing an Unmanned Aircraft System Pilot Kit (UASP-kit) for Wildland Fire UAS Operators

The use of unmanned aircraft systems (UAS) to support disaster management is becoming more widespread. Uninhibited by many of the operational constraints imposed on crewed aircraft, UAS have the potential to augment the aerial response in a number of ways, including supporting situation awareness, thereby accelerating disaster management efforts. The intent of the Scalable Traffic management for Emergency Response Operations (STEReO) activity is to build an ecosystem that will allow small UAS (sUAS) operations to fly safely in the airspace during disaster management events. The first step toward this goal is to develop a small, single-user tool (the UASP-kit) that will enhance an sUAS pilot’s situation awareness of the airspace. User needs for the functions and features of this tool were collected during a walkthrough over multiple days with subject matter experts from the US Forest Service. A prototype of the UASP-kit was then taken on an extended demonstration to multiple users, who were able to interact with it. User feedback was largely positive and users discussed the information they needed to support situation awareness in context. The demonstration also highlighted features that were unintuitive to use, and functions that need to be modified to make the kit more user-friendly and robust.

STEReO↗

Advanced Capabilities for Emergency Response Operations (ACERO)

The use of unmanned aircraft systems (UAS) to support disaster management is becoming more widespread. Uninhibited by many of the operational constraints imposed on crewed aircraft, UAS have the potential to augment the aerial response in a number of ways, including supporting situation awareness, thereby accelerating disaster management efforts. The intent of the Scalable Traffic management for Emergency Response Operations (STEReO) activity is to build an ecosystem that will allow small UAS (sUAS) operations to fly safely in the airspace during disaster management events. The first step toward this goal was to develop a small, single-user tool (the UASP-kit) that will enhance an sUAS pilot’s situation awareness of the airspace. In a subsequent project (Advanced Capabilities for Emergency Response Operations (ACERO)) the UASP-kit will be expanded and built upon to develop and airspace management tool.

STEReO↗

Converter Compressor Building, SWMU 089, Hot Spot Areas 1, 2, and 5 Operations, Maintenance, and Monitoring Report, Kennedy Space Center, Florida

This Operations, Maintenance, and Monitoring Report (OMMR) presents the findings, observations, and results from operation of the air sparging (AS) interim measure (IM) for Hot Spot (HS) Areas 1, 2, and 5 at the Converter Compressor Building (CCB) located at Kennedy Space Center (KSC), Florida. The objective of the IM at CCB HS Areas 1, 2, and 5 is to decrease concentrations of volatile organic compounds (VOCs) in groundwater in the treatment zones via AS to levels that will enable a transition to a monitored natural attenuation (MNA) phase. This OMMR presents system operations and maintenance (O&M) information and performance monitoring results since full-scale O&M began in June 2014 (2 months after initial system startup in April 2014), including quarterly performance monitoring events in July and October 2014 and January and May 2015. Based on the results to date, the AS system is operating as designed and is meeting the performance criteria and IM objective. The performance monitoring network is adequately constructed for assessment of IM performance at CCB HS Areas 1, 2, and 5. At the March 2014 KSC Remediation Team (KSCRT) Meeting, team consensus was reached for the design prepared for expansion of the system to treat the HS 4 area, and at the November 2014 KSCRT Meeting, team consensus was reached that HS 3 was adequately delineated horizontally and vertically and for selection of AS for the remedial approach for HS 3. At the July 2015 KSCRT meeting, team consensus was reached to continue IM operations in all zones until HSs 3 and 4 is operational, once HS 3 and 4 zones are operational discontinue operations in HS 1, 2, and 5 zones where concentrations are less than GCTLs to observe whether rebounding conditions occur. Team consensus was also reached to continue quarterly performance monitoring to determine whether operational zones achieve GCTLs and to continue annual IGWM of CCB-MW0012, CCBMW0013, and CCB-MW0056, located south of the treatment area. The next performance monitoring event is scheduled for July 2015.

Converter Compressor Building↗