Datasets for IWG Report on Energy Communities

Datasets associated with figures in the Initial Report to the President on Empowering Workers Through Revitalizing Energy Communities (available at: https://netl.doe.gov/sites/default/files/2021-04/Initial%20Report%20on%20Energy%20Communities_Apr2021.pdf) from the Interagency Working Group for Coal and Power Plant Communities. These data align to the White House’s The Interagency Working Group on Coal and Power Plant Communities and Economic Revitalization, https://energycommunities.gov/

Coal,Fossil Energy,Jobs and Employment,United Stat↗

Energy Exascale Earth System Model v2.0

First release of version 2 of the Energy Exascale Earth System Model. The atmosphere component remains EAM. Major changes since version 1 include: all column-physics parameterizations are computed on a separate grid that has approximately half the number of points of the dynamics grid, a new nonhydrostatic dynamical core (running in hydrostatic mode) with semi-Lagrangian tracer transport, CLUBB updated from v1 to v2, a new convective trigger (dCAPE/ULL) based on the dynamic Convective Available Potential Energy (CAPE) (dCAPE) and the Unrestricted Launch Level (ULL) concepts is used in ZM. minimum cloud droplet number changed, gravity wave drag energy conservation fixed and new tunings used, dust emission size distribution changed to emit more coarse dust particles The land component is still ELM. Major changes since version 1 include: using SNICAR-AD for radiation in snow to match the sea-ice model and fixing bugs in snow compaction and water state calculation. The ocean component remains MPAS-ocean. Major change since version 1 include: Redi isopycnal mixing has been updated, tested, and tuned in combination with the Gent-McWilliams parameterization, a sign error was fixed in the 3rd-order flux routines, the mesh used in low-resolution coupled cases was modified and the time steps adjusted, new regionally refined meshes were created, one focused on North America and another on the Southern Ocean, including ice shelf cavities. The sea-ice component remains MPAS-seaice. Major changes since version 1 include: A new heat- and freshwater-conserving coupling of frazil ice, turning off of SSH filtering, addition of SNICAR-AD and snow grain aging. The land-ice component remains MPAS-Albany-landIce (MALI) and is a static ice sheet. There is more out-of-the-box support for cryosphere configurations including the new regionally refined configuration around Antarctica with ice shelf cavities. The river model is MOSART. The half-degree river mesh was redone so it no longer treats Black and Caspian seas as ocean. The coupler remains cpl7/MCT. Major changes since version 1 include handling of ice shelf melt fluxes (heat / freshwater exchange with the ocean), and data icebergs. All components allow regional refinement of their meshes and two separate example of refinement, one in and around North America and one around Antarctica and the Southern Ocean, are provided.

E3SM Project, DOE↗

A taxonomy of systems that combine utility-scale renewable energy and energy storage technologies

Interest in renewable energy-based hybrid systems—which combine multiple renewable energy and/or energy storage technologies—is apparent and growing. Such systems could play an important role in the grid of the future, but our ability to quantify their potential impacts is hindered by (a) the inconsistent treatment of hybrid systems and (b) an incomplete understanding of which aspects of hybridization will have the greatest influence. In this article, we review the literature and propose an organization scheme for utility-scale hybrid systems in which electricity is generated from commercially available, renewable energy technologies, and electricity is the only output. Based on this literature review, we propose three categories for delineating systems that link multiple renewable energy and/or energy storage technologies: co-located resources (locational linkage only), virtual power plants (operational linkage only), and full hybrids (location and operational linkages). Proposing a categorization based on whether the systems involve locational and/or operational linkages reflects the fact that technology combinations do not represent a meaningful delineation. In addition, the categories are ideal for informing model development efforts, by identifying the unique characteristics that must be captured in adequate representations of systems that fall under each category. Our categories can also help inform policy considerations, as they delineate system characteristics that would introduce distinct permitting, siting, interconnection, and policy challenges. Therefore, we believe that our proposed taxonomy will help organize thinking and research efforts in a way that will enable consistent evaluation of the costs, values, and potential of renewable energy-based hybrids.

25 ENERGY STORAGE↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Simulating the Effects of Surface Energy Partitioning on Convective Organization: Case Study and Observations in the US Southern Great Plains

Realistic cloud-resolving simulations were performed to study the effects of surface energy partitioning (surface sensible and latent heat fluxes) on the organization of isolated convection into larger mesoscale convective systems (MCSs) near the US Southern Great Plains. The role of cold pools in mediating surface-convection interactions was explored. Better organized MCSs tended to occur in the experiments with perturbed wetter soil (and more active vegetation), regardless of the effects of soil moisture on the diurnal timing of convective triggering. Wetter soil led to shallower boundary layers and more convective available potential energy than drier soil. The roles of cold pools on convection are lifecycle-stage dependent: A dry surface allows more numerous colliding cold pools, thereby aiding in convective triggering by reducing entrainment in the early stages, and providing gust-front uplift in later stages. However, horizontal propagation of the cold-pool density current can outrun the convective system, creating a slantwise updraft and thus weakening the gust front uplift in later stages. This effect calls into question previous cold pool parameterizations, in which the gust front uplift is mainly proportional to the negative buoyancy of cold air. Finally, both the model and observation show an enhancement of surface latent heat flux during the passage of a gust front at night, suggesting that a positive feedback between the surface and convection helps MCSs to persist into the nighttime.

54 ENVIRONMENTAL SCIENCES↗

Explicit soft supersymmetry breaking in the heterotic M-theory B - L MSSM

The strongly coupled heterotic M-theory vacuum for both the observable and hidden sectors of the B - L MSSM theory is reviewed, including a discussion of the “bundle” constraints that both the observable sector SU(4) vector bundle and the hidden sector bundle induced from a single line bundle must satisfy. Gaugino condensation is then introduced within this context, and the hidden sector bundles that exhibit gaugino condensation are presented. The condensation scale is computed, singling out one line bundle whose associated condensation scale is low enough to be compatible with the energy scales available at the LHC. The corresponding region of Kähler moduli space where all bundle constraints are satisfied is presented. The generic form of the moduli dependent F-terms due to a gaugino superpotential — which spontaneously break N = 1 supersymmetry in this sector — is presented and then given explicitly for the unique line bundle associated with the low condensation scale. The moduli-dependent coefficients for each of the gaugino and scalar field soft supersymmetry breaking terms are computed leading to a low-energy effective Lagrangian for the observable sector matter fields. We then show that at a large number of points in Kähler moduli space that satisfy all “bundle” constraints, these coefficients are initial conditions for the renormalization group equations which, at low energy, lead to completely realistic physics satisfying all phenomenological constraints. Finally, we show that a substantial number of these initial points also satisfy a final constraint arising from the quadratic Higgs-Higgs conjugate soft supersymmetry breaking term.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating Utility-Scale PV-Battery Hybrids in an Operational Model for the Bulk Power System

Systems that combine solar photovoltaic and battery energy storage technologies (PV-BES) are increasingly being proposed and deployed on the bulk power system. The operations and value of PV-BES systems have been extensively studied from the project developer's perspective through analyses that maximize plant-level revenue. However, PV-BES hybrids' operational characteristics are seldom studied from the perspective of bulk power system operators, who seek to optimize the performance of a suite of generation and storage assets that are connected via the transmission network. This work presents modeling approaches for representing and evaluating PV-BES hybrids in a model that optimizes operations across the bulk power system. Its novel contributions include demonstrating a technique to modify a unit commitment and dispatch model to represent the operational synergies of PV-BES hybrids. In particular, we describe the challenges and an approach for representing so-called DC-coupled PV-BES - which utilize a single bi-directional inverter - as a dispatchable resource in a commercial, production cost model (PCM), PLEXOS. We demonstrate this technique in a PCM study of the Los Angeles Department of Water and Power (LADWP) test system, by replacing existing PV and battery generators on the test system with our PV-BES hybrids. We then pursue scenario analysis that is designed to isolate the various drivers of operational strategies for DC-coupled PV-BES hybrids, including the nature of coupling, PV penetration on the system, and varying inverter loading ratios (or degrees of over-sizing of the PV field). Results from the analysis include utilization profiles for the PV DC energy across available pathways, dispatch profiles for the battery component, and the hybrid technologies' impacts on system-wide production costs. The approach presented in this paper can be used in any PCM that is looking to study PV-BES hybrids as a resource in different power system configurations and services.

14 SOLAR ENERGY↗

Digital Twins for Nuclear Power Plants and Facilities

The nuclear digital twin (DT) is the virtual representation of a nuclear energy system across its lifecycle. The nuclear DT uses real-time information and other data sources to improve the process of design, licensing, construction, security, O&M, decommissioning, and waste disposal. By leveraging the knowledge base and experience from the past 40 years of LWR operation, the nuclear DT is helping to accelerate the development and deployment of advanced nuclear technology in areas of passive safety, new fuel forms, instrumentation, and reactor control. For the currently operating nuclear fleet, DTs are reducing the operational risks, increasing plant availability, increasing energy capability, and reducing electricity production costs. For advanced fission and fusion reactors, DTs are being used to design for passive safety and built-in security-by-design. Rapidly deployable small modular reactor (SMR) and microreactor designs compatible with modular construction techniques and advanced manufacturing will be the new normal, reducing the need for large capital expenditures and compressing construction schedules. In addition, lower operational and maintenance costs will be realized by reducing the complexity of operations, staffing needs, and maintenance-related activities.

Kropaczek, Dave↗

Transition of surface energy budget in the Gobi Desert between spring and summer seasons

The surface energetics of the southwest Gobi Desert, including the temporal variations and diurnally averaged properties of the surface energy budget components, was investigated. The field program was conducted during the spring and summer of 1984, with the measurement system designed to monitor radiative exchange, heat/moisture storage in the soil, and sensible and latent heat exhange between the ground and the atmosphere. Results of the analysis reveal a seasonal transition feature not expected of a midlatitude desert. Namely, the differences in both surface radiation exchange and the distibution of sensible and latent heat transfer arise within a radiatively forced environment that barely deviates from spring to summer in terms of available solar energy at the surface. Both similarities and differences in the spring and summer surface energy budgets arise from differences imparted to the system by an increase in the summertime atmospheric moisture content. Changes in the near-surface mixing ratio are shown to alter the effectiveness of the desert surface in absorbing radiative energy and redistibuting it to the lower atmosphere through sensible and latent heat exchange.

Smith, Eric A.↗

FY 2022 Idaho National Laboratory Site Sustainability Plan

The mission of the Department of Energy (DOE) is to ensure America’s security and prosperity by addressing its energy, environmental and nuclear challenges through transformative science and technology solutions. This FY 2022 Idaho National Laboratory Site Sustainability Plan (SSP) was developed to enable and sustain Idaho National Laboratory’s (INL’s) mission to discover, demonstrate, and secure innovative nuclear solutions, clean energy options, and critical infrastructure. DOE Order 436.1, “Departmental Sustainability,” provides requirements and assigns responsibilities for managing sustainability within DOE to ensure that DOE missions are carried out in a sustainable manner, to institute wholesale cultural change to factor sustainability into all DOE decisions, and to ensure DOE achieves sustainability goals. DOE Order 436.1 also requires DOE sites to commit appropriate personnel resources, establish a financing plan that prioritizes the use of life-cycle cost effective private-sector financing, optimize the application of appropriations and budgeted funds, and establish specific performance measures and deliverables designed to achieve the listed requirements. The SSP was developed according to the narrative requirements from the “FY 2022 DOE Site Sustainability Plan Guidance” document issued in September 2021. The SSP contains strategies and activities that will lead to continual energy, water, and waste reductions that move the INL site toward meeting DOE sustainability goals and requirements. The SSP summarizes energy and available fuel use reporting requirements and references criteria for instituting sustainable design. SSP requirements are integrated into each INL site contractor’s Integrated Safety Management System and Environmental Management System (EMS). Finally, the Sustainability Program directives, based on this SSP, are integrated into INL/LTD-21-62463, Annual Laboratory Plan 2021, and operations and acquisition systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

FY 2023 Idaho National Laboratory Site Sustainability Plan

The mission of the Department of Energy (DOE) is to ensure America’s security and prosperity by addressing its energy, environmental and nuclear challenges through transformative science and technology solutions. This FY 2022 Idaho National Laboratory Site Sustainability Plan (SSP) was developed to enable and sustain Idaho National Laboratory’s (INL’s) mission to discover, demonstrate, and secure innovative nuclear solutions, clean energy options, and critical infrastructure. DOE Order 436.1, “Departmental Sustainability,” provides requirements and assigns responsibilities for managing sustainability within DOE to ensure that DOE missions are carried out in a sustainable manner, to institute wholesale cultural change to factor sustainability into all DOE decisions, and to ensure DOE achieves sustainability goals. DOE Order 436.1 also requires DOE sites to commit appropriate personnel resources, establish a financing plan that prioritizes the use of life-cycle cost effective private-sector financing, optimize the application of appropriations and budgeted funds, and establish specific performance measures and deliverables designed to achieve the listed requirements. The SSP was developed according to the narrative requirements from the “FY 2022 DOE Site Sustainability Plan Guidance” document issued in September 2021. The SSP contains strategies and activities that will lead to continual energy, water, and waste reductions that move the INL site toward meeting DOE sustainability goals and requirements. The SSP summarizes energy and available fuel use reporting requirements and references criteria for instituting sustainable design. SSP requirements are integrated into each INL site contractor’s Integrated Safety Management System and Environmental Management System (EMS). Finally, the Sustainability Program directives, based on this SSP, are integrated into INL/LTD-21-62463, Annual Laboratory Plan 2021, and operations and acquisition systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Relative Cost-Effectiveness of Electricity and Transportation Policies as a Means to Reduce CO2 Emissions in the United States: A Multi-Model Assessment

Two common energy policy instruments in the United States are tax incentives and technology standards. Although these instruments have been shown to be less cost-effective as a means to reduce CO2 emissions than direct emissions pricing mechanisms, it can be challenging to compare the CO2 emissions reduction costs of such policies across sectors, given the wide range in estimates for any given policy and inconsistencies in how such estimates are constructed across studies. This study addresses this analytical gap by simultaneously comparing the cost-effectiveness of policies across the electricity and transportation sectors using three publicly available US energy system models (EM-NEMS, ReEDS, and GCAM-USA). Four policies are explicitly compared: wind and solar tax credits, a renewable portfolio standard (RPS), a renewable fuel standard (RFS), and an electric vehicle (EV) tax credit. An economy-wide carbon tax is used as a benchmark for cost-effectiveness. Results from this study confirm prior insights about the cost-effectiveness of economy-wide carbon pricing relative to sectoral instruments but also reveal several novel insights about particular sectoral policies. Specifically, this study finds that (1) current electricity tax incentives provide uneven support for wind and solar technologies, (2) despite known inefficiencies, renewable energy policies in the electricity sector are less expensive than earlier estimates due to technology advancement and changes in market conditions, (3) within transportation, an expanded RFS with increasing advanced biofuel targets is more cost-effective than an EV tax credit extension under plausible assumptions, (4) EV incentives lead to a rebound in conventional vehicle fuel economy that further erodes cost-effectiveness, and (5) the change in policy costs over time is not known a priori, but the relative cost ordering among these policies does not depend on the timeframe of analysis. These results are largely robust to the underlying modeling framework, increasing the confidence with which they can be applied to climate policy evaluation.

economics↗

Energy analysis of convectively induced wind perturbations

Budgets of divergent and rotational components of kinetic energy (KD and KR) are examined for four upper level wind speed maxima that develop during the fourth Atmospheric Variability Experiment (AVE IV) and the first AVE-Severe Environmental Storms and Mesoscale Experiment (AVE-SESAME I). A similar budget analysis is performed for a low-level jet stream during AVE-SESAME I. The energetics of the four upper level speed maxima is found to have several similarities. The dominant source of KD is cross-contour flow by the divergent wind, and KD provides a major source of KR via a conversion process. Conversion from available potential energy provides an additional source of KR in three of the cases. Horizontal maps reveal that the conversions involving KD are maximized in regions poleward of the convection. Low-level jet development during AVE-SESAME I appears to be assisted by convective activity to the west.

Fuelberg, Henry E.↗