Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arms control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Integrated controls-structures design methodology development for a class of flexible spacecraft

Future utilization of space will require large space structures in low-Earth and geostationary orbits. Example missions include: Earth observation systems, personal communication systems, space science missions, space processing facilities, etc., requiring large antennas, platforms, and solar arrays. The dimensions of such structures will range from a few meters to possibly hundreds of meters. For reducing the cost of construction, launching, and operating (e.g., energy required for reboosting and control), it will be necessary to make the structure as light as possible. However, reducing structural mass tends to increase the flexibility which would make it more difficult to control with the specified precision in attitude and shape. Therefore, there is a need to develop a methodology for designing space structures which are optimal with respect to both structural design and control design. In the current spacecraft design practice, it is customary to first perform the structural design and then the controller design. However, the structural design and the control design problems are substantially coupled and must be considered concurrently in order to obtain a truly optimal spacecraft design. For example, let C denote the set of the 'control' design variables (e.g., controller gains), and L the set of the 'structural' design variables (e.g., member sizes). If a structural member thickness is changed, the dynamics would change which would then change the control law and the actuator mass. That would, in turn, change the structural model. Thus, the sets C and L depend on each other. Future space structures can be roughly divided into four mission classes. Class 1 missions include flexible spacecraft with no articulated appendages which require fine attitude pointing and vibration suppression (e.g., large space antennas). Class 2 missions consist of flexible spacecraft with articulated multiple payloads, where the requirement is to fine-point the spacecraft and each individual payload while suppressing the elastic motion. Class 3 missions include rapid slewing of spacecraft without appendages, while Class 4 missions include general nonlinear motion of a flexible spacecraft with articulated appendages and robot arms. Class 1 and 2 missions represent linear mathematical modeling and control system design problems (except for actuator and sensor nonlinearities), while Class 3 and 4 missions represent nonlinear problems. The development of an integrated controls/structures design approach for Class 1 missions is addressed. The performance for these missions is usually specified in terms of (1) root mean square (RMS) pointing errors at different locations on the structure, and (2) the rate of decay of the transient response. Both of these performance measures include the contributions of rigid as well as elastic motion.

Maghami, P. G.↗

The Impact of Structural Vibration on Flying Qualities of a Supersonic Transport

A piloted simulation experiment has been conducted in the NASA Langley Visual/Motion Simulator facility to address the impact of dynamic aeroelastic effects on flying qualities of a supersonic transport. The intent of this experiment was to determine the effectiveness of several measures that may be taken to reduce the impact of aircraft flexibility on piloting tasks. Potential solutions that were examined included structural stiffening, active vibration suppression, and elimination of visual cues associated with the elastic modes. A series of parametric configurations was evaluated by six test pilots for several types of maneuver tasks. During the investigation, several incidents were encountered in which cockpit vibrations due to elastic modes fed back into the control stick through involuntary motions of the pilot's upper body and arm. The phenomenon, referred to as biodynamic coupling, is evidenced by a resonant peak in the power spectrum of the pilot's stick inputs at a structural mode frequency. The results of the investigation indicate that structural stiffening and compensation of the visual display were of little benefit in alleviating the impact of elastic dynamics on the piloting tasks, while increased damping and elimination of control-effector excitation of the lowest frequency modes offered great improvements when applied in sufficient degree.

David L Raney↗

Integrated Simulation Design Challenges to Support TPS Repair Operations

During the Orbiter Repair Maneuver (ORM) operations planned for Return to Flight (RTF), the Shuttle Remote Manipulator System (SRMS) must grapple the International Space Station (ISS), undock the Orbiter, maneuver it through a long duration trajectory, and orient it to an EVA crewman poised at the end of the Space Station Remote Manipulator System (SSRMS) to facilitate the repair of the Thermal Protection System (TPS). Once repair has been completed and confirmed, then the SRMS proceeds back through the trajectory to dock the Orbiter to the Orbiter Docking System. In order to support analysis of the complex dynamic interactions of the integrated system formed by the Orbiter, ISS, SRMS, and SSMS during the ORM, simulation tools used for previous ‘nominal’ mission support required substantial enhancements. These upgrades were necessary to provide analysts with the capabilities needed to study integrated system performance. Prevalent throughout this ORM operation is a dynamically varying topology. In other words, the ORM starts with the SRMS grappled to the mated Shuttle/ISS stack (closed loop topology), moves to an open loop chain topology consisting of the Shuttle, SRMS, and ISS, and then, at the repair configuration, extends the chain topology to one consisting of the Shuttle, SMS, ISS, and SSRMS/EVA crewman. The resulting long dynamic chain of vehicles and manipulators may exhibit significant motion between the Shuttle worksite and the EVA crewman due to the system flexibility throughout the topology (particularly within the SRMS/SSRMS joints and links). Since the attachment points of both manipulators span the flexible structure of the ISS, simulation analysis may also need to take that into consideration. Moreover, due to the lengthy time duration associated with the maneuver and repair, orbital effects become a factor and require the ISS vehicle control system to maintain active attitude control. Several facets of the ORM operation make the associated analytical efforts different from previous mission support, including: (1) the magnitude of the SRMS handled payload (Le., Orbiter class), (2) the orbital effects induced on the integrated system consisting of the large Shuttle and ISS masses connected by a light flexible SRMS, (3) long duration environmental consequences due to the lengthy operational times associated with the maneuver and repair of the TPS, (4) active attitude control (as opposed to free drift) interacting with the SRMS and SSRMS manipulators (also due to the length of the maneuver and repair), (5) relative dynamics between the EVA crewman and thc worksite influenced by the extended flexible topology. In order to meet these analysis challenges, an ORM simulation architecture was developed leveraging upon numerous pre-existing simulation elements to analyze the various subsystems individually. For example, core manipulator subsystem simulations for both the SRMS and SSRMS were originally combined to provide the dual-arm dynamics topology simulation (in the absence of orbital dynamics and vehicle control). This capability was later merged with the simulation used to analyze SRMS loading with a heavy payload in the orbital environment with an active payload control system (in this case, the ISS Attitude Control System (ACS)), configured for the ORM. The resulting worksite dynamics simulation, based off of the modified ORM simulation, provided the extended topological chain of vehicles and manipulators, while taking into account the orbital effects of both the Shuttle and ISS (as well as its ACS). Verification and validation (V&V) of these integrated simulations became a challenge in itself. A systematic approach needed to be developed such that integration simulation results could be tested against previous constituent simulations upon which these simulations were built. General V&V categories included: (1) core orbital state propagation, (2), stand-alone SRMS, (3) stand-alone SSRMS, (4) stand-alone ISS ACS, (5) integrated Shuttle, SRMS, ISS (with active ACS) in the orbital environment, and (5) dual-arm SRMS/SSRMS dynamics topology. Integrated simulation V&V run suites were created and correlated to verification runs from subsystem simulations, in order to establish the validity of the results. This paper discusses the simulation design challenges encountered while developing simulation capabilities to mirror the ORM operations. The paper also describes the incremental build approach that was utilized, starting with the subsystem simulation elements and integration into increasing more complex simulations until the resulting ORM worksite dynamics simulation had been assembled. Furthermore, the paper presents an overall integrated simulation V&V methodology based upon a subsystem level testing, integrated comparisons, and phased checkout.

Thermal Protection System↗

Dynamic Force Reconstruction of Transient Flap Control Force Experiments in a Hypersonic Wind Tunnel

This work details the design of a sliced-cone model with a flap embedded within the slice. The flap is controlled by a fast acting servo to simulate a control force of a hypersonic vehicle. Design considerations such as sensor placement, expected loading, servo arm selection, and cavity temperatures are detailed in this work. Such a design imparts a dynamic response of the test article and as such, dynamic force measurement methodologies are required to reconstruct the control forcing. Three methods are of particular interest: the Sum of Weighted Accelerations Technique, Time Domain Deconvolution Method, and Frequency Domain Inverse Method. Novel versions of each method have been applied to this dataset to improve the reconstruction accuracy.

dynamic balance↗

Dynamic Force Reconstruction of Transient Flap Control Force Experiments in a Hypersonic Wind Tunnel

This work details the design of a sliced-cone model with a flap embedded within the slice. The flap is controlled by a fast acting servo to simulate a control force of a hypersonic vehicle. Design considerations such as sensor placement, expected loading, servo arm selection, and cavity temperatures are detailed in this work. Such a design imparts a dynamic response of the test article and as such, dynamic force measurement methodologies are required to reconstruct the control forcing. Three methods are of particular interest: the Sum of Weighted Accelerations Technique, Time Domain Deconvolution Method, and Frequency Domain Inverse Method. Novel versions of each method have been applied to this dataset to improve the reconstruction accuracy.

dynamic balance↗

Review of Teleoperator Research

A predictor display to overcome time lag problems with remote control systems is discussed. The video picture is a (necessarily) time-delayed picture from the remote location, generated as a coherent frame (snapshot) so that all picture elements in a single scan are delayed the same. The computer-generated graphics is a line drawing of the present configuration of the manipulator arm, vehicle or other device. The latter is generated by using the same control signals which are sent to the remote manipulator (device) to drive a computer model of it. The computer model is drawn on the video display in exactly the same location as where it will actually be after a one-way time delay and where it will be seen to be on the video after one round-trip time delay. If one waits at least one round-trip delay without moving, both the graphics model and the video picture of the manipulator (device) are seen to coincide. The predictor technque proved to work well and was shown for time delays in the 1-3 second range to reduce completion times for a variety of manipulation tasks by 50-150 percent reliably.

Sheridan, T. B.↗

Method and system for providing autonomous control of a platform

The present application provides a system for enabling instrument placement from distances on the order of five meters, for example, and increases accuracy of the instrument placement relative to visually-specified targets. The system provides precision control of a mobile base of a rover and onboard manipulators (e.g., robotic arms) relative to a visually-specified target using one or more sets of cameras. The system automatically compensates for wheel slippage and kinematic inaccuracy ensuring accurate placement (on the order of 2 mm, for example) of the instrument relative to the target. The system provides the ability for autonomous instrument placement by controlling both the base of the rover and the onboard manipulator using a single set of cameras. To extend the distance from which the placement can be completed to nearly five meters, target information may be transferred from navigation cameras (used for long-range) to front hazard cameras (used for positioning the manipulator).

Seelinger, Michael J.↗

Optimized Resolved-Rate Control Of Telerobotic Manipulator

Laboratory Telerobotic Manipulator (LTM) is seven-degree-of-freedom robot arm built for evaluation in ground-based research to assess role of redundant-degree-of-freedom arms in outerspace operations. Each arm has three pitch/yaw joints: one at shoulder, another at elbow, and third at wrist. Seventh degree of freedom provided by wrist-roll joint. Offers advantages of more efficient use of workspaces and ability to reach around obstacles, redundant manipulators used in mobile robots and teleoperators for hazardous environments, automotive assembly, welding, and spray painting.

Barker, L. Keith↗

Field Experiments using Telepresence and Virtual Reality to Control Remote Vehicles: Application to Mars Rover Missions

This paper will describe a series of field experiments to develop and demonstrate file use of Telepresence and Virtual Reality systems for controlling rover vehicles on planetary surfaces. In 1993, NASA Ames deployed a Telepresence-Controlled Remotely Operated underwater Vehicle (TROV) into an ice-covered sea environment in Antarctica. The goal of the mission was to perform scientific exploration of an unknown environment using a remote vehicle with telepresence and virtual reality as a user interface. The vehicle was operated both locally, from above a dive hole in the ice through which it was launched, and remotely over a satellite communications link from a control room at NASA's Ames Research center, for over two months. Remote control used a bidirectional Internet link to the vehicle control computer. The operator viewed live stereo video from the TROV along with a computer-gene rated graphic representation of the underwater terrain showing file vehicle state and other related information. Tile actual vehicle could be driven either from within the virtual environment or through a telepresence interface. In March 1994, a second field experiment was performed in which [lie remote control system developed for the Antarctic TROV mission was used to control the Russian Marsokhod Rover, an advanced planetary surface rover intended for launch in 1998. Marsokhod consists of a 6-wheel chassis and is capable of traversing several kilometers of terrain each day, The rover can be controlled remotely, but is also capable of performing autonomous traverses. The rover was outfitted with a manipulator arm capable of deploying a small instrument, collecting soil samples, etc. The Marsokhod rover was deployed at Amboy Crater in the Mojave desert, a Mars analog site, and controlled remotely from Los Angeles. in two operating modes: (1) a Mars rover mission simulation with long time delay and (2) a Lunar rover mission simulation with live action video. A team of planetary geologists participated in the mission simulation. The scientific goal of the science mission was to determine what could be learned about the geologic context of the site using the capabilities of imaging and mobility provided by the Marsokhod system in these two modes of operation. I will discuss the lessons learned from these experiments in terms of the strategy for performing Mars surface exploration using rovers. This research is supported by the Solar System Exploration Exobiology, Geology, and Advanced Technology programs.

Stoker, Carol↗

Effect of hand-arm exercise on venous blood constituents during leg exercise

Contributions by ancillary hand and arm actions to the changes in blood constituents effected by leg exercises on cycle ergometer were assessed. Static or dynamic hand-arm exercises were added to the leg exercise (50 percent VO2 peak)-only control regimens for the subjects (19-27 yr old men) in the two experimental groups. Antecubital venous blood was analyzed at times 0, 15, and 30 min (T0, T15, and T30) for serum Na(+), K(+), osmolality, albumin, total CA(2+), and glucose; blood hemoglobin, hematocrit, and lactic acid; and change in plasma volume. Only glucose and lactate values were affected by additional arm exercise. Glucose decreased 4 percent at T15 and T30 after static exercise, and by 2 percent at T15 (with no change at T30) after dynamic arm exercise. Conversely, lactic acid increased by 20 percent at T30 after static exercise, and by 14 percent by T15 and 6 percent at T30 after dynamic arm exercise. It is concluded that additional arm movements, performed usually when gripping the handle-bar on the cycle ergometer, could introduce significant errors in measured venous concentrations of glucose and lactate in the leg-exercised subjects.

Wong, N.↗

Integration of a computerized two-finger gripper for robot workstation safety

A microprocessor-based controller has been developed that continuously monitors and adjusts the gripping force applied by a special two-finger gripper. This computerized force sensing gripper system enables the endeffector gripping action to be independently detected and corrected. The gripping force applied to a manipulated object is real-time monitored for problem situations, situations which can occur during both planned and errant robot arm manipulation. When unspecified force conditions occur at the gripper, the gripping force controller initiates specific reactions to cause dynamic corrections to the continuously variable gripping action. The force controller for this intelligent gripper has been interfaced to the controller of an industrial robot. The gripper and robot controllers communicate to accomplish the successful completion of normal gripper operations as well as unexpected hazardous situations. An example of an unexpected gripping condition would be the sudden deformation of the object being manipulated by the robot. The capabilities of the interfaced gripper-robot system to apply workstation safety measures (e.g., stop the robot) when these unexpected gripping effects occur have been assessed.

Sneckenberger, John E.↗

Head-coupled remote stereoscopic camera system for telepresence applications

The Virtual Environment Workstation Project (VIEW) at NASA's Ames Research Center has developed a remotely controlled stereoscopic camera system that can be used for telepresence research and as a tool to develop and evaluate configurations for head-coupled visual systems associated with space station telerobots and remore manipulation robotic arms. The prototype camera system consists of two lightweight CCD video cameras mounted on a computer controlled platform that provides real-time pan, tilt, and roll control of the camera system in coordination with head position transmitted from the user. This paper provides an overall system description focused on the design and implementation of the camera and platform hardware configuration and the development of control software. Results of preliminary performance evaluations are reported with emphasis on engineering and mechanical design issues and discussion of related psychophysiological effects and objectives.

Bolas, M. T.↗

Manipulation of large objects

Remote manipulator control experiments have been conducted to investigate the problems related to the 'controlled collision' aspect of manipulation. A six degrees of freedom pantograph arm with a six-dimensional force-torque balance sensor and microprocessor-driven real-time graphics display are employed in the experiments. Among other results, it is found that the use of computer force-torque feedback loop for 'stop at contact' provides a nearly linear relation between load transfer to jigs at 'stop at contact', rate of motion, and preset force-torque threshold values for stop under limited motion and load conditions.

Bejczy, A. K.↗

Work capacity during 30 days of bed rest with isotonic and isokinetic exercise training

Results are presented from a study to determine whether or not short-term variable intensity isotonic and intermittent high-intensity isokinetic short-duration leg exercise is effective for the maintenance of peak O2 (VO2) uptake and muscular strength and endurance, respectively, during 30 days of -6 deg head-down bed rest deconditioning. The results show no significant changes in leg peak torque, leg mean total work, arm total peak torque, or arm mean total work for members of the isotonic, isokinetic, and controls groups. Changes are observed, however, in peak VO2 levels. The results suggest that near-peak variabile intensity, isotonic leg excercise maintains peak VO2 during 30 days of bed rest, while peak intermittent, isokinetic leg excercise protocol does not.

Greenleaf, J. E.↗

Dynamic model and cooperative control of a serially linked manipulator system

The use of a redundant manipulator to execute multiple tasks specified at different points on the manipulator is demonstrated. This is accomplished by decomposing a redundant arm at an intermediate arm location called the 'elbow' into two nonredundant local arms referred as the 'basearm' and the 'forearm'. This decomposition transforms a redundant arm into a serially linked dual-arm system, where the cooperation between the basearm and the forearm is carried out through the task distribution and the elbow control. The kinematics of a decomposed redundant manipulator are discussed, and a Cartesian space dynamic model and dynamic equation of a decomposed redundant manipulator are presented. The capability of generating Cartesian force, the local efficiency of generating Cartesian acceleration, and dynamic task distribution are discussed.

Lee, Sukhan↗

Enhanced carotid-cardiac baroreflex response and elimination of orthostatic hypotension 24 hours after acute exercise in paraplegics

To test the hypothesis that an acute bout of maximal exercise can ameliorate orthostatic hypotension consequent to prolonged wheelchair confinement, we evaluated heart rate (HR), systolic (SBP) and diastolic (DBP) blood pressure responses during 15 minutes of 70 degrees head-up tilt (HUT) in 10 paraplegic subjects 24 hours after arm crank exercise designed to elicit maximal effort, and during a control (no exercise) conditions. Additionally, the carotid baroreceptor stimulus-cardiac response relationship was determined by measurement of R-R interval during external application of graded pressures to the carotid sinuses. One week separated the treatment conditions. The maximum slope of the carotid-cardiac baroreflex response was increased (p = 0.049) by exercise (6.2 +/- 1.7 msec/mmHg) compared to control (3.3 +/- 0.6). During control HUT, HR increased from 61 +/- 1 to 90 +/- 7 bpm (p = 0.001) while SBP decreased from 118 +/- 5 to 106 +/- 9 mmHg (p = 0.025). During HUT 24 hours after exercise, HR increased from 60 +/- 2 to 90 +/- 4 bpm (p = 0.001), but the reduction in SBP was essentially eliminated (116 +/- 5 to 113 +/- 5 mmHg).

Engelke, K. A.↗

Enigma Version 12

Enigma Version 12 software combines model building, animation, and engineering visualization into one concise software package. Enigma employs a versatile user interface to allow average users access to even the most complex pieces of the application. Using Enigma eliminates the need to buy and learn several software packages to create an engineering visualization. Models can be created and/or modified within Enigma down to the polygon level. Textures and materials can be applied for additional realism. Within Enigma, these models can be combined to create systems of models that have a hierarchical relationship to one another, such as a robotic arm. Then these systems can be animated within the program or controlled by an external application programming interface (API). In addition, Enigma provides the ability to use plug-ins. Plugins allow the user to create custom code for a specific application and access the Enigma model and system data, but still use the Enigma drawing functionality. CAD files can be imported into Enigma and combined to create systems of computer graphics models that can be manipulated with constraints. An API is available so that an engineer can write a simulation and drive the computer graphics models with no knowledge of computer graphics. An animation editor allows an engineer to set up sequences of animations generated by simulations or by conceptual trajectories in order to record these to highquality media for presentation. Enigma Version 12 Lyndon B. Johnson Space Center, Houston, Texas 28 NASA Tech Briefs, September 2013 Planetary Protection Bioburden Analysis Program NASA's Jet Propulsion Laboratory, Pasadena, California This program is a Microsoft Access program that performed statistical analysis of the colony counts from assays performed on the Mars Science Laboratory (MSL) spacecraft to determine the bioburden density, 3-sigma biodensity, and the total bioburdens required for the MSL prelaunch reports. It also contains numerous tools that report the data in various ways to simplify the reports required. The program performs all the calculations directly in the MS Access program. Prior to this development, the data was exported to large Excel files that had to be cut and pasted to provide the desired results. The program contains a main menu and a number of submenus. Analyses can be performed by using either all the assays, or only the accountable assays that will be used in the final analysis. There are three options on the first menu: either calculate using (1) the old MER (Mars Exploration Rover) statistics, (2) the MSL statistics for all the assays, or This software implements penetration limit equations for common micrometeoroid and orbital debris (MMOD) shield configurations, windows, and thermal protection systems. Allowable MMOD risk is formulated in terms of the probability of penetration (PNP) of the spacecraft pressure hull. For calculating the risk, spacecraft geometry models, mission profiles, debris environment models, and penetration limit equations for installed shielding configurations are required. Risk assessment software such as NASA's BUMPERII is used to calculate mission PNP; however, they are unsuitable for use in shield design and preliminary analysis studies. The software defines a single equation for the design and performance evaluation of common MMOD shielding configurations, windows, and thermal protection systems, along with a description of their validity range and guidelines for their application. Recommendations are based on preliminary reviews of fundamental assumptions, and accuracy in predicting experimental impact test results. The software is programmed in Visual Basic for Applications for installation as a simple add-in for Microsoft Excel. The user is directed to a graphical user interface (GUI) that requires user inputs and provides solutions directly in Microsoft Excel workbooks. This work was done by Shannon Ryan of the USRA Lunar and Planetary Institute for Johnson Space Center. Further information is contained in a TSP (see page 1). MSC- 24582-1 Micrometeoroid and Orbital Debris (MMOD) Shield Ballistic Limit Analysis Program Lyndon B. Johnson Space Center, Houston, Texas Commercially, because it is so generic, Enigma can be used for almost any project that requires engineering visualization, model building, or animation. Models in Enigma can be exported to many other formats for use in other applications as well. Educationally, Enigma is being used to allow university students to visualize robotic algorithms in a simulation mode before using them with actual hardware.

Shores, David↗

The Dual-Rasp Sampling System Design with Closed Pneumatic Sample Transfer

The novel Dual-Rasp sampling system has been developed for landed missions to low gravity planetary bodies and is particularly well suited for the unique environment of Saturn’s moon Enceladus. The Dual-Rasp sampling system has two counter-rotating rasp cutters that remove material from the surface and direct it into a guide. The cuttings follow the guide into a sample collection cup. When the sampling collection completes, the tool reconfigures by rotating the guide to create a closed circuit for pneumatic sample transfer from the collection cup to science instruments on the lander. A valve opens a gas tank and the gas flows from that tank into the sample collection cup and down rigid tubing to the science instruments chamber on the lander. A two degree of freedom arm with base actuators is used to deploy the sampler and control its sampling location.

Heness, Andrew B.↗