Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analytical sensitivity analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Acceleration and sensitivity analysis of lattice kinetic Monte Carlo simulations using parallel processing and rate constant rescaling

Kinetic Monte Carlo (KMC) simulation provides insights into catalytic reactions unobtainable with either experiments or mean-field microkinetic models. Sensitivity analysis of KMC models assesses the robustness of the predictions to parametric perturbations and identifies rate determining steps in a chemical reaction network. Stiffness in the chemical reaction network, a ubiquitous feature, demands lengthy run times for KMC models and renders efficient sensitivity analysis based on the likelihood ratio method unusable. We address the challenge of efficiently conducting KMC simulations and performing accurate sensitivity analysis in systems with unknown time scales by employing two acceleration techniques: rate constant rescaling and parallel processing. We develop statistical criteria that ensure sufficient sampling of non-equilibrium steady state conditions. Our approach provides the twofold benefit of accelerating the simulation itself and enabling likelihood ratio sensitivity analysis, which provides further speedup relative to finite difference sensitivity analysis. As a result, the likelihood ratio method can be applied to real chemistry. We apply our methodology to the water-gas shift reaction on Pt(111).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revisiting a minimally destructive analytic approach for determining electrochemical kinetic parameters: Measuring aluminum corrosion across a wide pH range based on the Butler-Volmer equation

Here, this study revisits the three-point sampling of the simplified Butler-Volmer equation to address the limitations of strong potentiodynamic polarization, which can introduce irreversible damage and uncertainty in corrosion analysis. The method extracts electrochemical kinetic parameters while minimizing polarization effects, evaluates noise sensitivity relative to overpotential, and accounts for errors from signal noise, OCP drift, ohmic resistance, and mass-transfer constraints. Verified against the Tafel extrapolation method for aluminum corrosion across a wide pH range, this low-polarization approach enables accurate evaluations with specific error estimates, offering a robust alternative to linear polarization resistance methods that assume constant Tafel slopes.

36 MATERIALS SCIENCE↗

Low cost solar array project: Composition measurements by analytical photon catalysis

The applicability of the photon catalysis technique for effecting composition analysis of silicon samples is assessed. In particular, the technique is to be evaluated as a detector for the impurities Al, Cr, Fe, Mn, Ti, V, Mo and Zr. During the first reporting period Al, Cr, Fe and Mn were detected with the photon catalysis method. The best fluorescence lines to monitor and determined initial sensitivities to each of these elements by atomic absorption calibration were established. In the course of these tests, vapor pressure curves for these four pure substances were mapped.

Sutton, D. G.↗

A method for the geometrically nonlinear analysis of compressively loaded prismatic composite structures

A method was developed for the geometrically nonlinear analysis of the static response of thin-walled stiffened composite structures loaded in uniaxial or biaxial compression. The method is applicable to arbitrary prismatic configurations composed of linked plate strips, such as stiffened panels and thin-walled columns. The longitudinal ends of the structure are assumed to be simply supported, and geometric shape imperfections can be modeled. The method can predict the nonlinear phenomena of postbuckling strength and imperfection sensitivity which are exhibited by some buckling-dominated structures. The method is computer-based and is semi-analytic in nature, making it computationally economical in comparison to finite element methods. The method uses a perturbation approach based on the use of a series of buckling mode shapes to represent displacement contributions associated with nonlinear response. Displacement contributions which are of second order in the model amplitudes are incorported in addition to the buckling mode shapes. The principle of virtual work is applied using a finite basis of buckling modes, and terms through the third order in the model amplitudes are retained. A set of cubic nonlinear algebraic equations are obtained, from which approximate equilibrium solutions are determined. Buckling mode shapes for the general class of structure are obtained using the VIPASA analysis code within the PASCO stiffened-panel design code. Thus, subject to some additional restrictions in loading and plate anisotropy, structures which can be modeled with respect to buckling behavior by VIPASA can be analyzed with respect to nonlinear response using the new method. Results obtained using the method are compared with both experimental and analytical results in the literature. The configurations investigated include several different unstiffened and blade-stiffening panel configurations, featuring both homogeneous, isotropic materials, and laminated composite material.

Stoll, Frederick↗

Discriminating Underground Nuclear Explosions Leading To Late-Time Radionuclide Gas Seeps

Utilizing historical data from the U.S. nuclear test program and freely available barometric pressure data, we performed an analytical barometric-pumping efficiency analysis to determine factors resulting in late-time radionuclide gas seeps from underground nuclear explosions. In this work, we considered 16 underground nuclear explosions with similar geology and test setup, of which five resulted in the measurement of late-time radionuclide gas concentrations at the ground surface. Additionally, the factors we considered include barometric frequency and amplitude, depth of burial, air-filled porosity, intact-rock permeability, fracture aperture, and fracture spacing. The analysis indicates that the best discriminators of late-time radionuclide gas seeps for these explosions are barometric frequency and amplitude and air-filled porosity. While geologic information on fracture aperture and spacing is not available for these explosions, the sensitivity of barometric-pumping efficiency to fracture aperture indicates that it would likely also be a good discriminator.

58 GEOSCIENCES↗

Trace metal mapping by laser-induced breakdown spectroscopy

Abstract: Laser-Induced Breakdown Spectroscopy (LIBS) is a sensitive optical technique capable of fast multi-elemental analysis of solid, gaseous and liquid samples. The potential applications of lasers for spectrochemical analysis were developed shortly after its invention; however the massive development of LIBS is connected with the availability of powerful pulsed laser sources. Since the late 80s of 20th century LIBS dominated the analytical atomic spectroscopy scene and its application are developed continuously. Here we review the utilization of LIBS for trace elements mapping in different matrices. The main emphasis is on trace metal mapping in biological samples.

Kaiser, Jozef↗

Investigate of atmospheric arsenic, cadmium, chromium, lead, and mercury levels in moss species found around Zilkale, by EDXRF Spectrometry

Zilkale is a castle located in Fırtına Valley and it is one of the most important historical structures in Çamlihemşin district of Rize Province in the Black Sea Region of Turkey. The castle surrounded by very high mountains that poke up into the clouds, and it rains here all year round. Tourism businesses or industrial plants are not so much there yet. In recent years, Zilkale region has begun the attract tourist, people on treaking holidays in the Kaçkar. But many domestic and foreign tourists come to this region by own car or tour buses. The aim of this study is to investigate the atmospheric concentrations of arsenic, cadmium, chromium, lead, and mercury levels in five different moss species collected around Zilkale by using Energy Dispersive X-ray Fluorescence (EDXRF) Spectrometry. The average concentrations of heavy metals in moss samples ranged from 0.79-4.63 ppm for arsenic, 54.47-143.39 ppm for chromium, 39.97-81.03 ppm for lead. The values of cadmium and mercury were found below the detection limit. This study has shown that Hypnum cupressiforme, Abietinella abietina, Rhytidium rugosum, Plagiomnium undulate, and Thuidium tamariscinum samples collected around Zilkale were used to assess the potential contamination of atmospheric As, Cd, Cr, Pb, Hg contamination in the region and made important contributions toward the understanding of atmospheric As, Cd, Cr, Pb, Hg baseline data can be used for identification of changes in the levels of these heavy metals in the studied area.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probabilistic analysis of a materially nonlinear structure

A probabilistic finite element program is used to perform probabilistic analysis of a materially nonlinear structure. The program used in this study is NESSUS (Numerical Evaluation of Stochastic Structure Under Stress), under development at Southwest Research Institute. The cumulative distribution function (CDF) of the radial stress of a thick-walled cylinder under internal pressure is computed and compared with the analytical solution. In addition, sensitivity factors showing the relative importance of the input random variables are calculated. Significant plasticity is present in this problem and has a pronounced effect on the probabilistic results. The random input variables are the material yield stress and internal pressure with Weibull and normal distributions, respectively. The results verify the ability of NESSUS to compute the CDF and sensitivity factors of a materially nonlinear structure. In addition, the ability of the Advanced Mean Value (AMV) procedure to assess the probabilistic behavior of structures which exhibit a highly nonlinear response is shown. Thus, the AMV procedure can be applied with confidence to other structures which exhibit nonlinear behavior.

Millwater, H. R.↗

Radio observations of D I and fractionation

We report observations to detect the 327 MHz line of atomic deuterium in the primarily molecular clouds towards Cas A and Sgr A, making appropriate choices of spectral and spatial resolution. Our best results for Cas A, based on 1253 hr of observing with the 85 foot (26 m) Hat Creek telescope and 45 hr with the very large array (VLA), yield an upper limit for the fraction of deuterium in atomic form, D I, of 0.14. We present an approximate analytical analysis of deuterium fractionation in translucent clouds, which shows that gas-phase ion-molecule reactions, assisted by dust and HD line self-shielding, are efficient in converting deuterium to HD. We conclude that little atomic deuterium is present in the molecular clumps in the Cas A clouds and that much higher sensitivity observations would be required to detect 327 MHz line in molecular clouds. We have also attempted to detect the 72 GHz line of DCO(+) toward Cas A. The observed upper limit to the DCO(+)/HCO(+) ratio of approximately 0.03 is not much larger than our theoretical estimate, and the DCO(+) line should be detectable with existing instrumentation, unless the temperature of these clouds is much larger than usually assumed.

Heiles, Carl↗

Wind Tunnel Testing of the NASA-DFRC Flutterometer using a Two DOF Wing Section

Flutter of an aeroelastic structure is potentially destructive aeroelastic instability. This phenomenon has motivated research within the aeroelastic community to develop methods that can accurately predict aeroelastic instabilities. The Flutterometer method used herein, and as developed by NASA DFRC, is based upon the mu method which has been coupled with wavelet filtering processes in estimating aeroelastic models from flight data. The approach leads to a methodology to predict the occurrence of flutter boundaries, and may prove to reliably predict flutter boundaries during flight tests. An analytical model is used as the first estimate of the aeroelastic structural dynamics, and uncertainty operators are introduced into the system to model variations between the theoretical system and the physical system. The modelling uncertainties are then updated from experimental data. Although the model used did not work well with this particular experiment, a sensitivity analysis was additionally performed and improvements suggested.

Strganac, Thomas W.↗

Experimental Setup for Mechanically Testing Subscale Triangular, Rollable, and Collapsible Deployable Composite Booms

High-strain composite deployable space structures are used for space infrastructure and science applications such as solar array supports, antennae, camera masts, and lightweight structures supporting solar sailing propulsion elements. Triangular, Rollable, and Collapsible (TRAC) deployable composite booms are one example of a high-strain composite deployable structure and were studied using novel experimental test and characterization methods developed under the Gravity Offloading and Analysis of Long Imperfection-sensitive Elements (GOALIE) project. In the present work, a subscale 7-m-long TRAC boom was suspended vertically to orient gravity along the length of the boom. By orienting vertically, highly nonlinear and unstable behavior often encountered during horizontally oriented gravity offload testing of similar structures was reduced. Pretest analytical predictions of TRAC booms indicated three unique failure modes, loads, and locations for three unique loading cases of in-plane bending, out-of-plane bending, and axial compression. To investigate the predicted behavior, an experimental test was set up to impart mechanical loads to a subscale TRAC boom. The experimental setup, loading cases, and instrumentation used to characterize the mechanical response of a subscale TRAC boom are described in this paper.

Experimental testing↗

Atom Probe Tomography for Catalysis Applications: A Review

Atom probe tomography is a well-established analytical instrument for imaging the 3D structure and composition of materials with high mass resolution, sub-nanometer spatial resolution and ppm elemental sensitivity. Thanks to recent hardware developments in Atom Probe Tomography (APT), combined with progress on site-specific focused ion beam (FIB)-based sample preparation methods and improved data treatment software, complex materials can now be routinely investigated. From model samples to complex, usable porous structures, there is currently a growing interest in the analysis of catalytic materials. APT is able to probe the end state of atomic-scale processes, providing information needed to improve the synthesis of catalysts and to unravel structure/composition/reactivity relationships. This review focuses on the study of catalytic materials with increasing complexity (tip-sample, unsupported and supported nanoparticles, powders, self-supported catalysts and zeolites), as well as sample preparation methods developed to obtain suitable specimens for APT experiments.

36 MATERIALS SCIENCE↗

Developing Fieldable Systems for Chemical Sensing Using Field Asymmetric Ion Mobility Spectrometry and Mass Spectrometry

Currently, there is an urgent need for field-rugged and field-programmable sensor systems that provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. These devices must be portable, low cost, robust, and provide accurate measurements to avoid both false positive and negative results. Furthermore, the information provided by the devices must be received in a timely manner so that informed decisions can be immediately made and the appropriate actions taken. Two technologies that are unparalleled in their sensitivity, selectivity, and trace-level detection capabilities are field asymmetric ion mobility spectrometry (FAIMS) and mass spectrometry. Here, we will show progress that has been made toward developing fieldable FAIMS systems and mass spectrometers. Working in collaboration with Sionex Corporation, the microDMx detector was equipped with a continuous air sampling system to develop selective methods for the analysis of compounds of interest. A microdiaphragm pump (KNF Neuberger, Inc.) is used to pull in gas-phase analytes directly from the air for separation and detection with the FAIMS system. The FAIMS evaluation platform (SVAC) unit currently measures 9.8-inch x 4.6-inch x 3.2-inch, weighs 3.1 lb, and utilizes a {sup 63}Ni source to ionize incoming compounds. Analytes entering the unit are separated and identified by their characteristic response to the compensation voltage (V{sub c}) at a given rf field strength (V{sub rf}). This response has been observed to be unique for a wide range of substances studied. If additional verification were required or a targeted analyte present in a complex chemical matrix, a FAIMS unit equipped with a fast gas chromatography column has been evaluated. The unit combines the separation capabilities of gas chromatography with the selectivity of FAIMS. It measures 9.5-inch x 5.25-inch x 3.5-inch, weighs 3.8 lb, and uses a 10.6 eV photoionization source. Analytes are identified both by their elution time from the column and by the characteristic response in the FAIMS spectrum. Analysis times required to obtain results for most analytes examined are less than three minutes. A fieldable mass spectrometer system is also being developed that includes sampling, ionization, mass selection and detection, vacuum technology, and analytical methodology with remote data transmission. Multiple methods for mass selection are being explored, including both Penning and Paul type ion traps as well as a quadrupole system to determine which is best suited for a portable mass spectrometer. Several ionization sources and ion counting methods will also be evaluated to establish their effectiveness with each system. The intended result of this project is a handheld mass spectrometer system capable of field deployment for the detection and identification of a wide range of gas-phase CBE species.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MS Based Metabonomics

Metabonomics is the latest and least mature of the systems biology triad, which also includes genomics and proteomics, and has its origins in the early orthomolecular medicine work pioneered by Linus Pauling and Arthur Robinson. It was defined by Nicholson and colleagues in 1999 as the quantitative measurement of perturbations in the metabolite complement of an integrated biological system in response to internal or external stimuli, and is often used today to describe many non-global types of metabolite analyses. Applications of metabonomics are extensive and include toxicology, nutrition, pharmaceutical research and development, physiological monitoring and disease diagnosis. For example, blood samples from millions of neonates are tested routinely by mass spectrometry (MS) as a diagnostic tool for inborn errors of metabolism. The metabonome encompasses a wide range of structurally diverse metabolites; therefore, no single analytical platform will be sufficient. Specialized sample preparation and detection techniques are required, and advances in NMR and MS technologies have led to enhanced metabonome coverage, which in turn demands improved data analysis approaches. The role of MS in metabonomics is still evolving as instrumentation and software becomes more sophisticated and as researchers realize the strengths and limitations of current technology. MS offers a wide dynamic range, high sensitivity, and reproducible, quantitative analysis. These attributes are essential for addressing the challenges of metabonomics, as the range of metabolite concentrations easily exceeds nine orders of magnitude in biofluids, and the diversity of molecular species ranges from simple amino and organic acids to lipids and complex carbohydrates. Additional challenges arise in generating a comprehensive metabolite profile, downstream data processing and analysis, and structural characterization of important metabolites. A typical workflow of MS-based metabonomics is shown in Figure 1. Gas chromatography-(GC)-MS was the most commonly used MS-based method for small molecule analysis in the 1970s and 1980s. It is still used today for the detection of many metabolic disorders and plays a strong role in plant metabonomics. Liquid chromatography (LC)-MS approaches have grown in popularity for metabolite studies, due to simpler sample preparation, reduced analysis times through the introduction of ultra-high performance liquid chromatography (UPLC)-MS and the ability to observe a wider range of metabolites. This chapter will discuss the role of MS in metabonomics, the techniques involved in this exciting area, and the current and future applications of the field. The various bioinformatics tools and multivariate analysis techniques used to maximize information recovery and to aid in the interpretation of the very large data sets typically obtained in metabonomics studies will also be discussed. While there are many different MS-based approaches utilized in metabonomics studies, emphasis will be placed on more established methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Membrane-Extraction Ion Mobility Spectrometry for In-Situ Detection of Chlorinated Hydrocarbons in Water

Membrane-extraction ion mobility spectrometry (ME-IMS) has been developed for in-situ sampling and analysis of trace chlorinated hydrocarbons in water in a single procedure. The sampling is configured so that aqueous contaminants permeate through a spiral hollow polydimethylsiloxane (PDMS) membrane and are carried away by a vapor flow through the membrane tube. The extracted analyte flows into an atmospheric pressure chemical ionization (APCI) chamber and is analyzed in a home-made IMS analyzer. PDMS membrane is found to effectively extract chlorinated hydrocarbon solvents from liquid phase to vapor. The specialized IMS analyzer has been found to have resolutions of R=33 and 41, respectively, for negative- and positive-modes and is capable of detecting aqueous tetrachloroethylene (PCE) and trichloroethylene (TCE) as low as 80 g/L and 74 g/L in negative ion mode, respectively. The time-dependent characteristics of sampling and detection of TCE are both experimentally and theoretically studied for various concentrations, membrane lengths, and flow rates. These characteristics demonstrate that membrane-extraction IMS is feasible for the continuous monitoring of chlorinated hydrocarbons in water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of turbine stator adjustment required for compressor design-point operation in high Mach number supersonic turbojet engines

For turbojet engines designed for flight Mach numbers of 2.5 and 3.0, use of turbine stator adjustment to maintain compressor design-point operation was evaluated analytically to determine the effect on the aerodynamics of the turbine. Since the effect of turbine stator adjustment is to make the turbine design sensitive to the particular engine design conditions selected, in some cases the turbine must be conservatively designed for the high-speed flight condition to assure satisfactory turbine performance at take-off. A new concept, the break-even point, is introduced to provide quick evaluation of the proximity of turbines to the blade-loading limit at any off-design operation.

ENGINES, CONTROL - TURBOJET↗

Analytic Modeling of the Hydrodynamic, Thermal, and Structural Behavior of Foil Thrust Bearings

A simulation and modeling effort is conducted on gas foil thrust bearings. A foil bearing is a self acting hydrodynamic device capable of separating stationary and rotating components of rotating machinery by a film of air or other gaseous lubricant. Although simple in appearance these bearings have proven to be complicated devices in analysis. They are sensitive to fluid structure interaction, use a compressible gas as a lubricant, may not be in the fully continuum range of fluid mechanics, and operate in the range where viscous heat generation is significant. These factors provide a challenge to the simulation and modeling task. The Reynolds equation with the addition of Knudsen number effects due to thin film thicknesses is used to simulate the hydrodynamics. The energy equation is manipulated to simulate the temperature field of the lubricant film and combined with the ideal gas relationship, provides density field input to the Reynolds equation. Heat transfer between the lubricant and the surroundings is also modeled. The structural deformations of the bearing are modeled with a single partial differential equation. The equation models the top foil as a thin, bending dominated membrane whose deflections are governed by the biharmonic equation. A linear superposition of hydrodynamic load and compliant foundation reaction is included. The stiffness of the compliant foundation is modeled as a distributed stiffness that supports the top foil. The system of governing equations is solved numerically by a computer program written in the Mathematica computing environment. Representative calculations and comparisons with experimental results are included for a generation I gas foil thrust bearing.

Bruckner, Robert J.↗

Use of XRF to characterize pre-Hanford orchards in the 100-OL-1 operable unit - 15717

Prior to 1943, Hanford site included several small towns with approximately 5,000 acres of orchards; at the time lead arsenate (PbHAsO{sub 4}) was the most commonly used pesticide. High concentration of lead and arsenic have been recorded where trees and stumps are still visible. Pre-Hanford orchards have been designated as 100-OL-1 Operable Unit. An Optimization study evaluated optimal counting time and position of the XRF from soils collected at the site. A Pilot Study included the evaluation of a field portable x-ray fluorescence (XRF) analyzer determining if performance results meet quality assurance criteria for cleanup. XRF has only previously been used as a screening tool. Four Decision Units (DUs) are to be analyzed: Ol-14. OL-32. OL-IU6-4 and OL-FR2-1. The DUs vary in size and have had distinct historic activities; such as 46.4 acres OL-14 having a military camp in the 1950's unlike OL-FR2-1 having been disturbed as it is near the F area reactor. Together the DUs provide an adequate representation of the Operable Unit. Screening criteria for lead (250 mg/kg) and arsenic (20 mg/kg). Six samples were collected ranging above, at, and below the screening criteria of 250 mg/kg for Pb and 20 mg/kg for As at the Decision Units OL-14 and OL-IU6-4, and labeled respectively. Samples were hand sieved, homogenized and placed in sample cups. Three replicates were prepared for each sample. Each sample cup was analyzed 3 times for 30 sec. A Standard Reference Material (SRM) was analyzed after every 20 readings. Three samples were selected for 15, 30, 45, 60, 90, 120, 150 and 180 second fixed and variable analysis. Two transects at OL-14, and one at OL-IU6-4 were created by selecting locations 90. around ground zero at distances of 0.5, 1, 2, 4, 8 and 12 feet (16 ft for OL-14). Locations were scanned in triplicate for 60 seconds each. 4 Decision Units spanning roughly 370 acres were chosen to represent 100-OL-1 Operable Unit. 40 locations within each DU were selected using Visual Sample Plan (VSP) with a random start and systematic grid pattern. Each location would be analyzed with 3 replicates and a 60 second count time. The Standard Reference Material (SRM) and blank are analyzed after every 20 counts to ensure accuracy. Data is extracted from XRF to be implemented in GIS for visual representation of site with 1943 and 2013 aerial imagery. Discussion/Conclusion: - XRF provided a good indication of precision and accuracy relative to ICP with a linear correlation R{sup 2} value higher than anticipated at .9735; - MDL proved the detection limit is significantly lower than the screening criteria; - When comparing results from the first 40 locations of OL-14 to the total 80 locations of OL-14, the same variability was seen; - We expect high concentrations of Pb and As to be where past orchards are present though this does not occur as all sites. Significance: - XRF is competent for decision making as values fall within ±20% ICP data; - The highest concentrations are not where expected, which may be an issue for sites outside of Hanford that have had more development; - The size of the DU does not affect the number of samples measured. Future Work: - Verification and validation of the XRF Data (QA/QC); - Revise conceptual site model; - Statistical evaluations to investigate: Estimation of variability in surface soils, appropriate size for DU, and sample size per DU; - Coordinating sample results through CORE; - Displaying sample results in PHOENIX (GIS tool)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗