Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “air conditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Lawrence Berkeley National Lab Building 59

The building management system in Building 59 is monitoring and archiving building-level electricity usage, HVAC and lighting system states (e.g., setpoint, temperature, flow rate, pressure), indoor environmental conditions (air temperature, relative humidity, CO2), on-site weather (air temperature, relative humidity), and especially occupant counts as well as other metrics such as Wi-Fi signal. This dataset could support multiple use cases, such as model predictive control and occupant related demand management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Commercial Building Lighting as a Frequency Regulation Resource

This paper evaluates the potential for automated lighting control as a resource for frequency regulation of the electric grid system in the context of current energy policies, economic incentives, and technological trends. The growing prevalence of renewable energy has increased the need for ancillary services to maintain grid frequency and stability. While demand side resources like heating, ventilating, and air-conditioning systems, as well as water treatment plants are already evaluated as regulation service providers, the potential application to electrical lighting systems has largely been ignored. Yet, aggregations of lighting systems that are retrofitted with intelligent controls could conceivably contribute to frequency regulation services with little impact on user comfort. To further explore the feasibility of lighting potential, this paper explores (1) how lighting control systems are limited by visual comfort perception and acceptability, (2) how such limitations impact the performance of the lighting system as an frequency regulation resource, and (3) how the market potential of lighting systems as demand side resources compares in different regional transmission organizations. Finally, the impact of developing technologies on the application of lighting systems for frequency regulation is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Implementation of Fault-Correction Algorithms in Fault Detection and Diagnostics Tools

A fault detection and diagnostics (FDD) tool is a type of energy management and information system that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Building operators on the leading edge of technology adoption use FDD tools to enable median whole-building portfolio savings of 8%. Although FDD tools can inform operators of operational faults, currently an action is always required to correct the faults to generate energy savings. A subset of faults, however, such as biased sensors, can be addressed automatically, eliminating the need for staff intervention. Automating this fault “correction” can significantly increase the savings generated by FDD tools and reduce the reliance on human intervention. Doing so is expected to advance the usability and technical and economic performance of FDD technologies. This paper presents the development of nine innovative fault auto-correction algorithms for Heating, Ventilation, and Air Conditioning pi(HVAC) systems. When the auto-correction routine is triggered, it overwrites control setpoints or other variables to implement the intended changes. It also discusses the implementation of the auto-correction algorithms in commercial FDD software products, the integration of these strategies with building automation systems and their preliminary testing.

field testing↗

Using Residential and Office Building Archetypes for Energy Efficiency Building Solutions in an Urban Scale: A China Case Study

Building energy consumption accounts for 36% of the overall energy end use worldwide and is growing rapidly as developing countries continue to urbanize. Understanding the energy use at urban scale will lay the foundation for identification of energy efficiency opportunities to be deployed at speed. China has almost half of global new constructions and plays an important role in building suitability. However, an open source national building energy consumption database is not available in China. To provide data support for building energy consumptions, this paper used a simulation method to develop an urban building energy consumption database for a pilot city in Wuhan, China. First, residential, small, and large office building archetype energy models were created in EnergyPlus to represent typical building energy consumption in Wuhan. The baseline reference model simulation results were further validated using survey data from the literature. Second, stochastic simulations were conducted to consider different design parameters and occupants’ energy usage intensity scenarios, such as thermal properties of the building envelope, lighting power density, equipment power density, HVAC (heating, ventilation and air conditioning) schedule, etc. A building energy consumption database was generated for typical building archetypes. Third, data-driven regression analysis was conducted to support quick building energy consumption prediction using key high- level building information inputs. Finally, a web-based urban energy platform and an interface were developed to support further third-party application development. The research is expected to provide fast energy efficiency building design solutions for urban planning, new constructions as well as building retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frequency Analysis of Solar PV Power to Enable Optimal Building Load Control

In this paper, we present a flexibility estimation mechanism for buildings’ thermostatically controlled loads (TCLs) to enable the distribution level consumption of the majority of solar photovoltaic (PV) generation by local building TCLs. The local consumption of PV generation provides several advantages to the grid operation as well as the consumers, such as reducing the stress on the distribution network, minimizing voltage fluctuations and two-way power flows in the distribution network, and reducing the required battery storage capacity for PV integration. This would result in increasing the solar PV generation penetration levels. The aims of this study are twofold. First, spectral (frequency) analyses of solar PV power generation together with the power consumption of multiple building TCLs (such as heating, ventilation, and air conditioning (HVAC) systems, water heaters, and refrigerators) are performed. These analyses define the bandwidth over which these TCLs can operate and also describe the PV generation frequency bandwidth. Such spectral analyses, in frequency domain, can help identify the flexible components of PV generation that can be consumed by the various TCLs through optimal building load utilization. Second, a quadratic optimization problem based on model predictive control is formulated to allow consuming most of the low and medium frequency content of the PV power locally by building TCLs, while maintaining occupants’ comfort and TCLs’ physical constraints. The solution to the proposed optimization problem is achieved using optimal control strategies. Numerical results show that most of the low and medium frequency content of the PV generation can be consumed locally by building TCLs. The remaining high-frequency content of the PV generation can then be stored/offset using energy storage systems.

14 SOLAR ENERGY↗

Virtual Pressure Sensor for Electronic Expansion Valve Control in a Vapor Compression Refrigeration System

Virtual sensor technology, which uses simulation models/algorithms to calculate a value to represent an unmeasured variable or replace a directly measured reading, has attracted many studies in the heating, ventilation, air conditioning and refrigeration (HVAC&R) industry. However, most virtual sensor technologies are developed for fault detection and diagnostics (FDD) purposes, which generally compare the virtual sensor values with actual measured values to detect if any fault occurred and identify the causes that led to the fault. It is rare to see studies focus on control performance of virtual sensors after substituting an actual sensor. This is particularly important for the system with no redundant sensor since a virtual sensor is the most effective way to operate the system in the desirable region when any sensor failure occurs. To address this gap, this paper develops a new virtual pressure sensor technology to substitute the actual pressure measurement for electronic expansion valve (EXV) control in a vapor compression refrigeration system by integrating compressor and valve characteristics. The control performance of this proposed virtual pressure sensor technology under various operating conditions is validated with experimental data. Closed loop EXV control simulations with the proposed virtual pressure sensor are conducted, and the results are analyzed.

47 OTHER INSTRUMENTATION↗

Energy Efficiency Package for Tenant Fit-Out: Laboratory Testing and Validation of Energy Savings and Indoor Environmental Quality

Approximately 40% of the total U.S. office floor space of 1.5 billion sq.m (16 billion sq.ft.) is leased space occupied by tenants. Tenant fit-out presents a key opportunity to incorporate energy efficiency within the real estate business cycle. We designed a package of energy efficiency measures tailored to the scope of a tenant fit-out. This tenant fit-out package (TFP) includes advanced lighting and heating, ventilating and air-conditioning (HVAC) controls as core measures, with ceiling fans, automated shading, and plug load controls as additional optional measures. We conducted laboratory testing of six configurations of the package to evaluate energy savings, indoor environmental quality, and identify installation, commissioning, and operational issues. Combined savings for HVAC, lighting, and plug loads ranged from 33–40%. Lighting savings ranged from 69–83%, and HVAC savings from 20–40%. The laboratory testing also revealed some minor but tractable challenges with installation and commissioning of HVAC controls. Overall, the results demonstrate that significant savings can be realized in existing office buildings by incorporating relatively low-risk, proven measures at the time of a tenant fit-out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Evaluation of Occupancy-Aware HVAC Control for Residential Building Energy Efficiency and Occupant Comfort

Occupancy-aware heating, ventilation, and air conditioning (HVAC) control offers the opportunity to reduce energy use without sacrificing thermal comfort. Residential HVAC systems often use manually-adjusted or constant setpoint temperatures, which heat and cool the house regardless of whether it is needed. By incorporating occupancy-awareness into HVAC control, heating and cooling can be used for only those time periods it is needed. Yet, bringing this technology to fruition is dependent on accurately predicting occupancy. Non-probabilistic prediction models offer an opportunity to use collected occupancy data to predict future occupancy profiles. Smart devices, such as a connected thermostat, which already include occupancy sensors, can be used to provide a continually growing collection of data that can then be harnessed for short-term occupancy prediction by compiling and creating a binary occupancy prediction. Real occupancy data from six homes located in Colorado is analyzed and investigated using this occupancy prediction model. Results show that non-probabilistic occupancy models in combination with occupancy sensors can be combined to provide a hybrid HVAC control with savings on average of 5.0% and without degradation of thermal comfort. Model predictive control provides further opportunities, with the ability to adjust the relative importance between thermal comfort and energy savings to achieve savings between 1% and 13.3% depending on the relative weighting between thermal comfort and energy savings. In all cases, occupancy prediction allows the opportunity for a more intelligent and optimized strategy to residential HVAC control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical Estimation of the Energy Impacts of Projects Installed through Residential Property Assessed Clean Energy Financing Programs in California

We examine the energy use impacts of energy efficiency and solar PV projects financed by residential property assessed clean energy (R-PACE) programs in California. We leverage household-level interval meter data to apply normalized metered energy consumption (NMEC) methods at significant scale—more than 25,000 electric meters and more than 15,000 gas meters. We develop a comparison group to account for non-project-related changes in usage. The projects include homes that replaced existing HVAC equipment with higher-efficiency units and homes that installed central heating or air conditioning equipment for the first time. We have limited information on pre-project household equipment stock so we develop a method to infer new installations. We find that projects that installed energy efficiency technologies reduce electricity consumption by approximately 3% and gas consumption by approximately 3.5% on average. When we remove homes that installed new cooling and heating equipment for the first time, savings rise to approximately 5% for electricity and approximately 6% for gas. Given the California climate and the results of an existing study of similar California projects, these results are in line with expectations. Solar PV projects produce electricity that offsets approximately 69% of household electricity consumption on average. We estimate that California R-PACE projects installed through the end of 2019 produce annual reductions in grid-tied electricity consumption of 506 GWh (equivalent to the electricity consumption of approximately 74,000 California households) and gas consumption reductions of 2 million therms (equivalent to the gas consumption of approximately 4700 California households) in a typical weather year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hardware-Based Emulator with Deep Learning Model for Building Energy Control and Prediction Based on Occupancy Sensors’ Data

Heating, ventilation, and air conditioning (HVAC) is the largest source of residential energy consumption. Occupancy sensors’ data can be used for HVAC control since it indicates the number of people in the building. HVAC and sensors form a typical cyber-physical system (CPS). In this paper, we aim to build a hardware-based emulation platform to study the occupancy data’s features, which can be further extracted by using machine learning models. In particular, we propose two hardware-based emulators to investigate the use of wired/wireless communication interfaces for occupancy sensor-based building CPS control, and the use of deep learning to predict the building energy consumption with the sensor data. We hypothesize is that the building energy consumption may be predicted by using the occupancy data collected by the sensors, and question what type of prediction model should be used to accurately predict the energy load. Another hypothesis is that an in-lab hardware/software platform could be built to emulate the occupancy sensing process. The machine learning algorithms can then be used to analyze the energy load based on the sensing data. To test the emulator, the occupancy data from the sensors is used to predict energy consumption. The synchronization scheme between sensors and the HVAC server will be discussed. We have built two hardware/software emulation platforms to investigate the sensor/HVAC integration strategies, and used an enhanced deep learning model—which has sequence-to-sequence long short-term memory (Seq2Seq LSTM)—with an attention model to predict the building energy consumption with the preservation of the intrinsic patterns. Because the long-range temporal dependencies are captured, the Seq2Seq models may provide a higher accuracy by using LSTM architectures with encoder and decoder. Meanwhile, LSTMs can capture the temporal and spatial patterns of time series data. The attention model can highlight the most relevant input information in the energy prediction by allocating the attention weights. The communication overhead between the sensors and the HVAC control server can also be alleviated via the attention mechanism, which can automatically ignore the irrelevant information and amplify the relevant information during CNN training. Our experiments and performance analysis show that, compared with the traditional LSTM neural network, the performance of the proposed method has a 30% higher prediction accuracy.

Ye, Zhijing↗

The Eco-Bio-Social Factors That Modulate Aedes aegypti Abundance in South Texas Border Communities

Aedes aegypti control requires dedicated resources that are usually scarce, limiting the reach and sustainability of vector control programs. This generates a need to focus on areas at risk of disease transmission and also understand the factors that might modulate local mosquito abundance. We evaluated the eco-bio-social factors that modulate indoor and outdoor relative abundance of female Ae. aegypti in communities of South Texas. We conducted housing quality and Knowledge Attitudes and Practices surveys in households that were part of a weekly mosquito surveillance program in November of 2017 and 2018. Our results showed widespread knowledge of mosquitoes and Zika virus by our participants. However, less than 35% considered them as serious problems in this region. The presence of window-mounted air conditioning units increased the risk of female mosquito relative abundance indoors. An increase in outdoor relative abundance was associated with larger properties and a higher number of children between 6 to 17 years of age. Interestingly, we observed that an increasing number of children <5 years of age modulated both indoor and outdoor relative abundance, with a 52% increase indoors and 30% decrease outdoors. The low perception of mosquito and disease risk highlights engagement needs for vector-borne disease prevention in this region. The identified risk factors can help guide public health officials in their efforts to reduce human and vector contact.

54 ENVIRONMENTAL SCIENCES↗

WHISPER: Wireless Home Identification and Sensing Platform for Energy Reduction

Many regions of the world benefit from heating, ventilating, and air-conditioning (HVAC) systems to provide productive, comfortable, and healthy indoor environments, which are enabled by automatic building controls. Due to climate change, population growth, and industrialization, HVAC use is globally on the rise. Unfortunately, these systems often operate in a continuous fashion without regard to actual human presence, leading to unnecessary energy consumption. As a result, the heating, ventilation, and cooling of unoccupied building spaces makes a substantial contribution to the harmful environmental impacts associated with carbon-based electric power generation, which is important to remedy. For our modern electric power system, transitioning to low-carbon renewable energy is facilitated by integration with distributed energy resources. Automatic engagement between the grid and consumers will be necessary to enable a clean yet stable electric grid, when integrating these variable and uncertain renewable energy sources. We present the WHISPER (Wireless Home Identification and Sensing Platform for Energy Reduction) system to address the energy and power demand triggered by human presence in homes. The presented system includes a maintenance-free and privacy-preserving human occupancy detection system wherein a local wireless network of battery-free environmental, acoustic energy, and image sensors are deployed to monitor homes, record empirical data for a range of monitored modalities, and transmit it to a base station. Several machine learning algorithms are implemented at the base station to infer human presence based on the received data, harnessing a hierarchical sensor fusion algorithm. Results from the prototype system demonstrate an accuracy in human presence detection in excess of 95%; ongoing commercialization efforts suggest approximately 99% accuracy. Using machine learning, WHISPER enables various applications based on its binary occupancy prediction, allowing situation-specific controls targeted at both personalized smart home and electric grid modernization opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Resolution PM2.5 Concentrations Estimation Based on Stacked Ensemble Learning Model Using Multi-Source Satellite TOA Data

Nepal has experienced severe fine particulate matter (PM2.5) pollution in recent years. However, few studies have focused on the distribution of PM2.5 and its variations in Nepal. Although many researchers have developed PM2.5 estimation models, these models have mainly focused on the kilometer scale, which cannot provide accurate spatial distribution of PM2.5 pollution. Based on Gaofen-1/6 and Landsat-8/9 satellite data, we developed a stacked ensemble learning model (named XGBLL) combined with meteorological data, ground PM2.5 concentrations, ground elevation, and population data. The model includes two layers: a XGBoost and Light GBM model in the first layer, and a linear regression model in the second layer. The accuracy of XGBLL model is better than that of a single model, and the fusion of multi-source satellite remote sensing data effectively improves the spatial coverage of PM2.5 concentrations. Besides, the spatial distribution of the daily mean PM2.5 concentrations in the Kathmandu region under different air conditions was analyzed. The validation results showed that the monthly averaged dataset was accurate (R2 = 0.80 and root mean square error = 7.07). In addition, compared to previous satellite PM2.5 datasets in Nepal, the dataset produced in this study achieved superior accuracy and spatial resolution.

Environmental Sciences & Ecology↗

Evaluating the Adaptability of Reinforcement Learning Based HVAC Control for Residential Houses

Intelligent Heating, Ventilation, and Air Conditioning (HVAC) control using deep reinforcement learning (DRL) has recently gained a lot of attention due to its ability to optimally control the complex behavior of the HVAC system. However, more exploration is needed on understanding the adaptability challenges that the DRL agent could face during the deployment phase. Using online learning for such applications is not realistic due to the long learning period and likely poor comfort control during the learning process. Alternatively, DRL can be pre-trained using a building model prior to deployment. However, developing an accurate building model for every house and deploying a pre-trained DRL model for HVAC control would not be cost-effective. In this study, we focus on evaluating the ability of DRL-based HVAC control to provide cost savings when pre-trained on one building model and deployed on different house models with varying user comforts. We observed around 30% of cost reduction by pre-trained model over baseline when validated in a simulation environment and achieved up to 21% cost reduction when deployed in the real house. This finding provides experimental evidence that the pre-trained DRL has the potential to adapt to different house environments and comfort settings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical Modeling of Direct Expansion (DX) Cooling System for Multiple Research Use Cases

This study provides a general procedure to generate a direct expansion (DX) cooling coil system for a roof top unit (RTU), which is a typical heating ventilation and air-conditioning (HVAC) system for commercial buildings in the United States. Experimental data from a full-scale unoccupied 2-story commercial building is used for the HVAC modeling. The regression for identifying the model coefficients was carried out with multiple stages, and the results were validated with measured data. The model’s applicability was evaluated with multiple case studies, including a building energy simulation (BES) program validation, model-based predictive control (MPC), and fault diagnostics and detection (FDD).

42 ENGINEERING↗

Co-Simulation of Electric Power Distribution Systems and Buildings including Ultra-Fast HVAC Models and Optimal DER Control

Smart homes and virtual power plant (VPP) controls are growing fields of research with potential for improved electric power grid operation. A novel testbed for the co-simulation of electric power distribution systems and distributed energy resources (DERs) is employed to evaluate VPP scenarios and propose an optimization procedure. DERs of specific interest include behind-the-meter (BTM) solar photovoltaic (PV) systems as well as heating, ventilation, and air-conditioning (HVAC) systems. The simulation of HVAC systems is enabled by a machine learning procedure that produces ultra-fast models for electric power and indoor temperature of associated buildings that are up to 133 times faster than typical white-box implementations. Hundreds of these models, each with different properties, are randomly populated into a modified IEEE 123-bus test system to represent a typical U.S. community. Advanced VPP controls are developed based on the Consumer Technology Association (CTA) 2045 standard to leverage HVAC systems as generalized energy storage (GES) such that BTM solar PV is better utilized locally and occurrences of distribution system power peaks are reduced, while also maintaining occupant thermal comfort. An optimization is performed to determine the best control settings for targeted peak power and total daily energy increase minimization with example peak load reductions of 25+%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Updating the Building Science Advisor (BSA): A Tool to Assist in the Design of Durable Building Envelopes

Predicting the moisture durability of building envelope components remains challenging due to multiple influencing factors, including material selection, assembly positioning, local climate conditions, air tightness, interior environment, and construction quality. Building codes increasingly emphasize energy efficiency through enhanced insulation and tighter envelopes but offer limited guidance on moisture durability considerations. Consequently, builders face uncertainty, particularly as new materials and assemblies enter the market.The Building Science Advisor (BSA) is a free, web-based expert system developed to address these challenges by providing actionable insights into the moisture durability and energy efficiency of both new and retrofit wall designs. Recently updated, we are now providing version 3.0 of the tool. BSA features significant user interface improvements, enhancing navigation and user interaction through a refreshed, intuitive design. Additionally, the tool incorporates a newly developed database containing pre-simulated wall assembly cases, significantly reducing response times and improving the accuracy of moisture durability assessments. Furthermore, the updated BSA includes moisture content as a performance criterion, providing users with a more comprehensive understanding of moisture-related durability risks. These enhancements enable rapid, reliable assessments tailored to specific climate zones and local building practices. BSA continues to offer targeted guidance on wall retrofit scenarios and delivers access to an expanded library of location-specific building science resources.This paper describes these key updates, highlighting the enhanced features, expanded capabilities, and overall improvements to user experience and educational content. The paper includes a demonstration that illustrates how the revised BSA effectively supports practitioners in designing durable, energy-efficient building envelope assemblies.

Salonvaara, Mikael [ORNL] (ORCID:0000000318991554)↗

Advanced Frost Sensor for HVAC Applications

Frost is a common problem in heating, ventilation, and air conditioning (HVAC) systems that can degrade their efficiencies, leading to excessive electricity consumption. Appropriate defrosting is therefore essential for heat pumps and refrigeration systems. However, these systems typically run the defrost cycle based on a predetermined time interval, a method that does not accurately identify the amount of frost and thus consume excessive electricity. To substantially improve defrosting initiation and termination, this paper describes development of a smart sensor based on a capacitive sensing technique that can quantify frost accumulation and difference between frost, ice, and water. The reported sensor adopts interdigitated comb electrodes and can be updated to a potential multifunctional sensor array for the enhancing identification of frost, ice, and water with the integrated measurement of surface temperature, frost capacitance, and resistance. The proposed frost sensor is potentially expected to have widespread applications in HVAC systems, including heat pumps, refrigerators, and commercial refrigeration systems.

Gao, Zhiming↗