Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “agreements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Accurate ab initio potential energy curves and spectroscopic properties of the four lowest singlet states of C 2

The diatomic carbon molecule has a complex electronic structure with a large number of low-lying electronic excited states. In this work, the potential energy curves (PECs) of the four lowest lying singlet states (X-1 Sigma(+)(g), A(1)Pi(u), B-1 Delta(g), and B'(1)Sigma(+)(g)) were obtained by high-level ab initio calculations. Valence electron correlation was accounted for by the correlation energy extrapolation by intrinsic scaling (CEEIS) method. Additional corrections to the PECs included core-valence correlation and relativistic effects. Spin-orbit corrections were found to be insignificant. The impact of using dynamically weighted reference wave functions in conjunction with CEEIS was examined and found to give indistinguishable results from the even weighted method. The PECs showed multiple curve crossings due to the B-1 Delta(g) state as well as an avoided crossing between the two (1)Sigma(+)(g) states. Vibrational energy levels were computed for each of the four electronic states, as well as rotational constants and spectroscopic parameters. Comparison between the theoretical and experimental results showed excellent agreement overall. Equilibrium bond distances are reproduced to within 0.05 %. The dissociation energies of the states agree with experiment to within similar to 0.5 kcal/mol, achieving "chemical accuracy." Vibrational energy levels show average deviations of similar to 20 cm(-1) or less. The B-1 Delta(g) state shows the best agreement with a mean absolute deviation of 2.41 cm(-1). Calculated rotational constants exhibit very good agreement with experiment, as do the spectroscopic constants.

36 MATERIALS SCIENCE↗

Association of qualitative and quantitative imaging features on multiphasic multidetector CT with tumor grade in clear cell renal cell carcinoma

Purpose: The purpose of the study was to determine if enhancement features and qualitative imaging features on multiphasic multidetector computed tomography (MDCT) were associated with tumor grade in patients with clear cell renal cell carcinoma (ccRCC). Methods: In this retrospective, IRB approved, HIPAA-compliant, institutional review board-approved study with waiver of informed consent, 127 consecutive patients with 89 low grade (LG) and 43 high grade (HG) ccRCCs underwent preoperative four-phase MDCT in unenhanced (UN), corticomedullary (CM), nephrographic (NP), and excretory (EX) phases. Previously published quantitative (absolute peak lesion enhancement, absolute peak lesion enhancement relative to normal enhancing renal cortex, 3D whole lesion enhancement and the wash-in/wash-out of enhancement within the 3D whole lesion ROI) and qualitative (enhancement pattern; presence of necrosis; pattern of; tumor margin; tumor–parenchymal interface, tumor–parenchymal interaction; intratumoral vascularity; collecting system infiltration; renal vein invasion; and calcification) assessments were obtained for each lesion independently by two fellowship-trained genitourinary radiologists. Comparisons between variables included χ{sup 2}, ANOVA, and student t test. p values less than 0.05 were considered to be significant. Inter-reader agreement was obtained with the Gwet agreement coefficient (AC1) and standard error (SE) was reported. Results: No significant differences were observed between the LG and HG ccRCC cohorts with respect to absolute peak lesion enhancement and relative lesion enhancement ratio. There was a significant inverse correlation between low and high grade ccRCC and tumor enhancement the NP (71 HU vs. 54 HU, p < 0.001) and EX (52 HU vs. 39 HU, p < 0.001) phases using the 3D whole lesion ROI method. The percent wash-in of 3D enhancement from the UN to the CM phase was also significantly different between LG and HG ccRCCs (352% vs. 255%, p = 0.003). HG lesions showed significantly more calcification, necrosis, collecting system infiltration and ill-defined tumor margins (p < 0.05). Overall agreement between the two readers had a mean AC1 of 0.8172 (SE 0.0235). Conclusions: Quantitatively, high grade ccRCC had significantly lower whole lesion enhancement in the NP and EX phases on MDCT. Qualitatively, high grade ccRCC were significantly more likely to be associated with calcifications, necrosis, collecting system infiltration, and an ill-defined tumor margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic accuracy of MRI with extracellular vs. hepatobiliary contrast material for detection of residual hepatocellular carcinoma after locoregional treatment

Purpose: To compare the diagnostic accuracy of extracellular gadolinium-based contrast-enhanced MRI (Gd-MRI) and gadoxetic acid-enhanced MRI (EOB-MRI) for the assessment of hepatocellular carcinoma (HCC) response to locoregional therapy (LRT) using explant correlation as the reference standard. Methods: Forty-nine subjects with cirrhosis and HCC treated with LRT who underwent liver MRI using either Gd-MRI (n = 26) or EOB-MRI (n = 23) within 90 days of liver transplantation were included. Four radiologists reviewed the MR images blinded to histology to determine the size and percentage of viable residual HCC using a per-lesion explant reference standard. Sensitivities, specificities, accuracies, and agreement with histology for the detection residual HCC were calculated. Results: Gd-MRI had greater agreement with histology (ICC: 0.98 [0.95–0.99] vs. 0.80 [0.63–0.90]) and greater sensitivity for viable HCC (76% [13/17 50–93%] vs. 58% [7/12; 28–85%]) than EOB-MRI; specificities were similar (84% [16/19; 60–97%] vs. 85% [23/27; 66–96%]). Areas under ROC curves for detecting residual viable tumor were 0.80 (0.64–0.92) for Gd-MRI and 0.72 (0.55–0.85) for EOB-MRI. Gd-MRI had greater inter-rater agreement than EOB-MRI for determining the size of residual viable HCC (ICC: 0.96 [0.92–0.98] vs. 0.85 [0.72–0.92]). Conclusion: Gd-MRI may be more accurate and precise than EOB-MRI for the assessment of viable HCC following LRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic performance of MRI- versus MDCT-categorized T3cd/T4 for identifying high-risk stage II or stage III colon cancers: a pilot study

Purpose: The aim of this study was to determine the diagnostic performance of magnetic resonance imaging (MRI)-categorized T3cd/T4 tumors for identifying high-risk stage II or stage III cancer in patients with curatively resectable colon cancer in comparison to that of multidetector computed tomography (MDCT). Materials and Methods: Thirty-eight patients with histopathologically indicated adenocarcinomas prospectively underwent MRI of the colon. Two radiologists independently and retrospectively assessed for T-category, including T3 substage (≤ T3ab vs. ≥ T3cd). The diagnostic accuracies and interreader agreements between assessments using each modality were compared using a pairwise comparison of receiver-operating characteristic curves and a weighted κ statistic, respectively. Results: Twenty-nine patients (76.3%) were histopathologically diagnosed with high-risk stage II or stage III colon cancer. The false-positive rate with MRI was lower than that with MDCT (0% vs. 7.9% for reader 1, 2.6% vs. 10.6% for reader 2). The diagnostic performance of MRI was better than that of MDCT across both readers (AUC: 0.707 vs. 0.506 [P = 0.032] for reader 1, 0.651 vs. 0.485 [P = 0.055] for reader 2). Moreover, MRI interreader agreement for the assessment of T3cd/T4 was significantly better than that of MDCT (κ = 0.821 vs. 0.391 [P = 0.017]). Conclusion: The diagnostic performance of MR imaging of the colon may be better than that of MDCT for identifying high-risk stage II or stage III cases. Particularly, colon MRI reduced the false-positive rate and improved the interreader agreement, although further studies with a larger sample size are required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of SE-EPI-based T2 mapping for characterization of prostate cancer: a new method compared with the traditional CPMG method

Purpose: We aim to compare the results of spin echo–echo planar imaging (SE-EPI)-based T2 mapping with those of the conventional Carr–Purcell–Meiboom–Gill (CPMG) method and to investigate the potential validity of SE-EPI-T2 mapping for the characterization of prostate cancer (PCa). Methods: Our retrospective study included 42 PCa patients and 42 noncancer patients who underwent 3.0T MRI with b values ranging from 0 to 2000 s/mm{sup 2} and echo times (TEs) ranging from 32 to 100 ms before biopsies. Bland–Altman analysis was used to compare the agreement between the two methods. The correlations between CPMG-T2 values and SE-EPI-T2 values at different b values were determined by Spearman’s rho analysis or Pearson analysis. The Mann–Whitney U test and two-sample t tests were used to analyze the differences between the cancerous and noncancerous groups. Results: Substantial agreement regarding the measurements was observed between the two methods. The average correlation between the CPMG-T2 values and SE-EPI-T2 values was moderate and positive, and the best correlations were found at b = 200 s/mm{sup 2} in the noncancer group (r = 0.557, P = 0.000) and at b = 100 s/mm{sup 2} in the cancer group (r = 0.537, P = 0.000). In addition, statistically significant differences were found between the noncancer and cancer groups in T2 values and ADC values (diff TEs) (P = 0.000). Conclusions: Substantial agreement in the measurements was found between the SE-EPI method and CPMG method. SE-EPI-based T2 mapping has potential clinical value for the prostate and can be considered an alternative to the traditional CPMG-T2 mapping method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Society of abdominal radiology gastrointestinal bleeding disease-focused panel consensus recommendations for CTA technical parameters in the evaluation of acute overt gastrointestinal bleeding

Purpose: To formulate consensus recommendations for CT angiography technical parameters used to evaluate overt gastrointestinal (GI) bleeding. Methods: An electronic questionnaire consisting of 17 questions was sent to a panel of 16 radiologists with expertise on the imaging of GI bleeding from the Society of Abdominal Radiology GI Bleeding disease-focused panel to obtain consensus agreement on issues related to CTA technical parameters for imaging overt GI bleeding. A multi-round Delphi method of voting was performed to obtain consensus which was defined as ≥ 80% agreement. Results: Consensus agreement was reached in 15/17 (89%) of the questions including the technique for the administration of IV contrast, the number of phases, scan timing, and image reconstruction. Conclusions: A panel of experts on the imaging of GI bleeding from the Society of Abdominal Radiology was able to reach consensus on the majority of technical parameters used for CTA of overt GI bleeding. These recommendations should improve the quality of patient care by adopting these minimal technical requirements for optimal exam performance and lead to less variation in the performance of these exams which will facilitate collecting and comparing published data from different centers. These recommendations will need revisions as additional scientific data become available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiologic-Pathologic Correlation of Hepatocellular Carcinoma Treated with Chemoembolization

To correlate posttreatment radiologic and pathologic findings in patients who underwent transarterial chemoembolization before transplantation or resection. Thirty-five patients with postchemoembolization follow-up imaging underwent liver transplantation/resection. Pre- and posttreatment contrast-enhanced magnetic resonance imaging were used to evaluate radiologic findings. Imaging characteristics using World Health Organization (WHO) and European Association for the Study of the Liver (EASL) criteria after treatment were evaluated. Treated lesions were examined by pathology (gold standard) for the assessment of necrosis. Radiologic findings on magnetic resonance imaging were correlated to pathologic findings to assess the predictability by imaging of actual necrosis. Kappa ({kappa}) statistics were used to determine intermethod agreement between WHO and EASL criteria. Fourteen (40%) of 35 lesions had biopsy-proven hepatocellular carcinoma. Thirteen (37%) of 35 target lesions showed complete pathologic necrosis. Complete pathologic necrosis was seen in 35% of lesions with pretreatment size <3 cm. Complete pathologic necrosis was seen in 1 (100%) of 1, 6 (67%) of 9, 6 (33%) of 18, and 0 (0%) of 7 of the lesions that exhibited complete response (CR), partial response (PR), stable disease (SD), or progressive disease (PD) by WHO criteria, respectively. Complete pathologic necrosis was seen in 9 (82%) of 11, 4 (36%) of 11, 0 (0%) of 8, and 0 (0%) of 5 of the lesions that showed CR, PR, SD, or PD by EASL criteria, respectively. EASL CR and WHO response were shown to have {>=}85% specificity for predicting complete pathologic necrosis. The {kappa} coefficient for agreement between WHO and EASL was 0.29. EASL and WHO criteria had minimal intermethod agreement. EASL CR and WHO response were able to predict pathologic necrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Determination of the Need for Intravenous Contrast in Musculoskeletal MRI Examinations Using IBM Watson’s Natural Language Processing Algorithm

Magnetic resonance imaging (MRI) protocoling can be time- and resource-intensive, and protocols can often be suboptimal dependent upon the expertise or preferences of the protocoling radiologist. Providing a best-practice recommendation for an MRI protocol has the potential to improve efficiency and decrease the likelihood of a suboptimal or erroneous study. The goal of this study was to develop and validate a machine learning-based natural language classifier that can automatically assign the use of intravenous contrast for musculoskeletal MRI protocols based upon the free-text clinical indication of the study, thereby improving efficiency of the protocoling radiologist and potentially decreasing errors. We utilized a deep learning-based natural language classification system from IBM Watson, a question-answering supercomputer that gained fame after challenging the best human players on Jeopardy! in 2011. We compared this solution to a series of traditional machine learning-based natural language processing techniques that utilize a term-document frequency matrix. Each classifier was trained with 1240 MRI protocols plus their respective clinical indications and validated with a test set of 280. Ground truth of contrast assignment was obtained from the clinical record. For evaluation of inter-reader agreement, a blinded second reader radiologist analyzed all cases and determined contrast assignment based on only the free-text clinical indication. In the test set, Watson demonstrated overall accuracy of 83.2% when compared to the original protocol. This was similar to the overall accuracy of 80.2% achieved by an ensemble of eight traditional machine learning algorithms based on a term-document matrix. When compared to the second reader’s contrast assignment, Watson achieved 88.6% agreement. When evaluating only the subset of cases where the original protocol and second reader were concordant (n = 251), agreement climbed further to 90.0%. The classifier was relatively robust to spelling and grammatical errors, which were frequent. Implementation of this automated MR contrast determination system as a clinical decision support tool may save considerable time and effort of the radiologist while potentially decreasing error rates, and require no change in order entry or workflow.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evolution of anthropogenic and biomass burning emissions of air pollutants at global and regional scales during the 1980-2010 period

Several different inventories of global and regional anthropogenic and biomass burning emissions are assessed for the 1980-2010 period. The species considered in this study are carbon monoxide, nitrogen oxides, sulfur dioxide and black carbon. The inventories considered include the ACCMIP historical emissions developed in support of the simulations for the IPCC AR5 assessment. Emissions for 2005 and 2010 from the Representative Concentration Pathways (RCPs) are also included. Large discrepancies between the global and regional emissions are identified, which shows that there is still no consensus on the best estimates for surface emissions of atmospheric compounds. At the global scale, anthropogenic emissions of CO, NOx and SO2 show the best agreement in most years. The agreement is low for BC emissions, particularly in the period prior to 2000. The best consensus is for NOx emissions for all periods and all regions, except for China where emissions in 1980 and 1990 need to be better defined. Emissions of CO need a better quantification in the USA for all periods; in Central Europe, the evolution of emissions during the past two decades needs to be better determined. The agreement between the different SO2 emissions datasets is rather good for the USA, but better quantification is needed elsewhere, particularly for Central Europe and China. The comparisons performed in this study show that the use of RCP8.5 for the extension of the ACCMIP inventory beyond 2000 is reasonable, until more global or regional estimates become available. Concerning biomass burning emissions, most inventories agree within 50-80%, depending on the year and season. The large differences are due to differences in the estimates of burned areas from the different available products, as well as in the amount of biomass burnt.

09 BIOMASS FUELS↗

Study of Magnetic Entropy Change in Nd{sub 0.67}Ba{sub 0.33}Mn{sub 0.98}Fe{sub 0.02}O{sub 3} by Means of Theoretical Models

Magnetic entropy change (−ΔS{sub M}) of Nd{sub 0.67} Ba{sub 0.33}Mn{sub 0.98}Fe{sub 0.02}O{sub 3} perovskite have been analyzed by means of theoretical models. An excellent agreement has been found between the (ΔS{sub M}) values estimated by Landau theory and those obtained using the classical Maxwell relation. In order to estimate the spontaneous magnetization M{sub spont}(T), we used the mean-field theory to analyses the (ΔS{sub M}) vs. M{sup 2} data. The obtained M{sub spont}(T) values are in good agreement with those found from the classical extrapolation from the Arrott plots(H/M vs. M{sup 2}), confirming that the magnetic entropy is a valid approach to estimate the spontaneous magnetization in our system. At a relatively low magnetic field, a phenomenological model has been used to estimate the values of the magnetic entropy change. The results are in good agreement with those obtained from the experimental data using Maxwell relation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The environmental impact of hydropower: a systematic review of the ecological effects of sub-daily flow variability on riverine fish

Hydropower can help facilitate power grid decarbonization because it can respond to short-term changes in power demand and is comparatively more reliable than intermittent wind and solar. However, flexible hydropower operations can create rapid and abnormal fluctuations in downstream flow conditions, which can negatively impact aquatic ecosystems. Accordingly, we conducted a systematic review on the ecological effects of hydropower-driven sub-daily flow variability (SDFV) on riverine fishes. We reviewed and synthesized 109 articles relevant to fish-SDFV relationships from seven sources, most of which focused on Salmonids in North America and northern and western Europe and were published in the last 15 years. We found strong agreement in the literature that SDFV increases fish stranding risk, destabilizes habitat, and decreases production and diversity. We found moderate agreement that SDFV interrupts fish reproduction, increases or has no impact on condition, and prompts or discourages movement depending on local channel conditions. We found little to no agreement for relationships between SDFV and mortality, physiology, and behavior. The effects of SDFV on riverine fish ecology are intertwined in the complex suite of biotic and abiotic characteristics that structure aquatic ecosystems and are highly site-, species-, and life stage-specific. Assessments of the impact of SDFV on fish ecology should first characterize local habitat and channel quality and fish community composition to identify specific, measurable ecological outcomes to sustain or enhance, and then design mitigation strategies tailored to those ecological objectives.

13 HYDRO ENERGY↗

Computational Modeling of Hydraulic Properties of a Sheared Single Rock Fracture

Flow through a single mechanically sheared Marcellus shale fracture was investigated computationally and experimentally. To provide a better understanding of the variation of hydraulic and geometrical characteristics of a fracture subjected to shearing, coupled shear flow tests on the fracture for four shearing displacement steps under constant normal stress were performed. At the end of each shearing step, computed tomography (CT) scans with resolution 26.8 μm were obtained and the corresponding fracture geometries were evaluated. The CT images were used to generate full aperture maps of the fracture configuration. In addition, average aperture maps were also created by averaging the full-resolution data over 10 × 10 pixels, smoothing out fine structural details. Computational modeling of water flow through the fractures at different shearing steps was performed using a modified local cubic law approach and the 3D full Navier–Stokes equations with the use of the ANSYS-Fluent software. Both the average aperture maps and full maps were used in these simulations. The experimental pressure drops of the fracture at shearing step 1, which has very small apertures, poorly matched the numerical results, quite likely because the fracture structure was inadequately captured by the scanning resolution. Shearing typically increased the aperture height of the fracture, whose features were then better captured by the CT scan. Good agreement between the experimental data and the numerical results of the full map for shearing step 2 was observed. The simulations were performed for both full and average aperture maps, and the effects of scan resolution and surface roughness on the accuracy of the results were studied. The modified local cubic law and full Navier–Stokes simulations of the averaged map fracture were found to be in good agreement. It was conjectured that this was because the nonlinear losses were insignificant for the smoothed out averaged map fracture. Similar comparisons with those of the full map showed agreement in trends, but there were some quantitative differences. The averaged fracture map simulations also predicted lower pressure drops compared to the full map, particularly for high flow rates. These differences were due to the fine-scale geometrical complexity (surface roughness) of fracture geometry that affects the fluid flow in the fracture. In conclusion, an improved cubic law model was also proposed, and its accuracy was verified by comparing its predictions with those of the Navier–Stokes simulations.

58 GEOSCIENCES↗

Cyclic-loading-induced Accumulation of Geometrically Necessary Dislocations Near Grain Boundaries in an Ni-based Superalloy

In this study, the fatigue-induced microstructure produced in a nickel-based polycrystalline superalloy that was subjected to cyclic loading was characterized by polychromatic x-ray microdiffraction (PXM) together with in-situ neutron diffraction and transmission-electron microscopy (TEM). In-situ neutron-diffraction measurements reveal two distinct stages of the fatigue damage: cyclic hardening followed by cyclic softening. Three-dimensional spatially resolved PXM micro-Laue measurements find an increase in the density of geometrically necessary dislocations near the grain boundaries, which is accompanied by lattice rotations and grain subdivisions. The PXM results are in agreement with the in-situ neutron-diffraction and TEM results.

36 MATERIALS SCIENCE↗

Comparison of two software systems for quantification of myocardial blood flow in patients with hypertrophic cardiomyopathy

Backgorund: Quantification of myocardial blood flow (MBF) by positron emission tomography (PET) is important for investigation of angina in hypertrophic cardiomyopathy (HCM). Several software programs exist for MBF quantification, but they have been mostly evaluated in patients (with normal cardiac geometry), referred for evaluation of coronary artery disease (CAD). Software performance has not been evaluated in HCM patients who frequently have hyperdynamic LV function, LV outflow tract (LVOT) obstruction, small LV cavity size, and variation in the degree/location of LV hypertrophy. Aim: We compared results of MBF obtained using PMod, which permits manual segmentation, to those obtained by FDA-approved QPET software which has an automated segmentation algorithm. Methods: {sup 13}N-ammonia PET perfusion data were acquired in list mode at rest and during pharmacologic vasodilation, in 76 HCM patients and 10 non-HCM patients referred for evaluation of CAD (CAD group.) Data were resampled to create static, ECG-gated and 36-frame-dynamic images. Myocardial flow reserve (MFR) and MBF (in ml/min/g) were calculated using QPET and PMod softwares. Results: All HCM patients had asymmetric septal hypertrophy, and 50% had evidence of LVOT obstruction, whereas non-HCM patients (CAD group) had normal wall thickness and ejection fraction. PMod yielded significantly higher values for global and regional stress-MBF and MFR than for QPET in HCM. Reasonably fair correlation was observed for global rest-MBF, stress-MBF, and MFR using these two softwares (rest-MBF: r = 0.78; stress-MBF: r = 0.66.; MFR: r = 0.7) in HCM patients. Agreement between global MBF and MFR values improved when HCM patients with high spillover fractions (> 0.65) were excluded from the analysis (rest-MBF: r = 0.84; stress-MBF: r = 0.72; MFR: r = 0.8.) Regionally, the highest agreement between PMod and QPET was observed in the LAD territory (rest-MBF: r = 0.82, Stress-MBF: r = 0.68) where spillover fraction was the lowest. Unlike HCM patients, the non-HCM patients (CAD group) demonstrated excellent agreement in MBF/MFR values, obtained by the two softwares, when patients with high spillover fractions were excluded (rest-MBF: r = 0.95; stress-MBF: r = 0.92; MFR: r = 0.95). Conclusions: Anatomic characteristics specific to HCM hearts contribute to lower correlations between MBF/MFR values obtained by PMod and QPET, compared with non-HCM patients. These differences indicate that PMod and QPET cannot be used interchangeably for MBF/MFR analyses in HCM patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gated SPECT myocardial perfusion imaging with cadmium-zinc-telluride detectors allows real-time assessment of dobutamine-stress-induced wall motion abnormalities

Background: Left ventricular (LV) ejection fraction (EF) during high dobutamine stress (HD) by real-time gated-SPECT myocardial perfusion imaging (MPI) on a cadmium-zinc-telluride (CZT) gamma camera was validated versus cardiac magnetic resonance imaging (CMR). Methods and results: After injecting 99mTc-tetrofosmin (320 MBq) in 50 patients (mean age 64 +/− 11 years), EF at rest and post-stress as well as relevant changes in EF at HD (ΔEF ≥ 5%) were assessed. CZT and CMR rest EF values yielded an excellent correlation and agreement (r = 0.96; P < 0.001; Bland–Altman limits of agreement (BA): + 0 to 14.8%). HD EF acquisition was feasible using CZT and correlated better to HD CMR EF than did post-stress CZT EF (r = 0.85 vs 0.76, respectively, all P < 0.001). Agreement in ΔEF detection between HD CMR and immediate post-stress CZT (reflecting standard acquisition using conventional SPECT camera unable to scan during stress) was 45%, while this increased to 85% with real-time HD CZT scan. Conclusion: Real-time ultrafast dobutamine gated-SPECT MPI with a CZT device is feasible and provides accurate measurements of HD LV performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A tale of two towers: comparing NEON and AmeriFlux data streams at Bartlett Experimental Forest

Long-term ecological data are essential for detecting impacts of climate change and other global change factors, and for making informed predictions about future change. However, long-term measurements are rarely replicated at the site level, which raises questions about their representativeness. We used a multiscale approach to evaluate the agreement of parallel observations from AmeriFlux and NEON (National Ecological Observatory Network) towers at Bartlett Experimental Forest, New Hampshire, USA. The two towers are separated by a horizontal distance of 93 m. Here, we focused our analysis on standard meteorological variables; fluxes of CO 2 , sensible heat, and latent heat measured by eddy covariance; and phenology derived from PhenoCam imagery. Results suggest excellent agreement between AmeriFlux and NEON in meteorology and phenology, and good agreement in fluxes at the half-hourly scale. However, large disagreements in CO 2 and latent heat fluxes occurred at the annual scale, with implications especially for the forest carbon balance. The AmeriFlux tower measurements indicate a site that is close to carbon-neutral (-8 ± 65 g C m -2 y -1 , mean ± 1 SD), whereas the NEON tower measurements indicate a forest that is a carbon sink (-137 ± 10 g C m -2 y -1 ). Causes of this disagreement may include measurement height (26 m vs. 35 m), which resulted in different flux footprints being measured by the two towers, and differences in the flux measurement systems. Our results suggest the need for caution when attempting to merge long-term flux data from two different measurement platforms, and when using measurements from any one measurement platform to inform decision-making on issues related to carbon accounting or natural climate solutions.

Carbon cycle↗

Development of a Griffin model of the advanced test reactor

In the pursuit of a higher fidelity deterministic simulation capability of the Advanced Test Reactor, it is important to have a fast yet accurate deterministic neutronics model. Here, to achieve this, we employed an advanced two-step method. The first step involves generating homogenized cross sections using OpenMC, a cutting-edge Monte Carlo neutron transport code. OpenMC offers excellent modular capabilities, allowing for easy component integration and flexibility in incorporating new designs into the model. The second step involves deterministic transport calculations, which are performed using Griffin, a reactor physics application based on the Multiphysics Object-Oriented Simulation Environment (MOOSE). To ensure the accurate spatial resolution and assignment of material cross sections, a Cubit-generated mesh for the Advanced Test Reactor is utilized as an intermediate step between the OpenMC and Griffin models; Griffin utilizes the mesh for its finite element solution, while OpenMC material identifications are written to the mesh file to be used in Griffin material assignments. Additionally, a Python-based script converts the cross sections generated by OpenMC into the ISOXML format required by Griffin. Initial comparisons using the Griffin diffusion solver indicated good agreement between the neutron multiplication factors obtained from the standalone OpenMC model and the Griffin model, with differences of less than 10 pcm in the 2D geometry configuration; it was later determined that this agreement was likely due to compensating effect and was more likely on the order of –700 pcm relative to the OpenMC solution. However, in three-dimensional calculations, an unacceptably large error (almost 8,000 pcm) was found in the Griffin solution with the diffusion solver. Subsequent calculations using Griffin’s discrete ordinates solver demonstrated substantially improved agreement, within 116 pcm of the OpenMC solution used to generate the cross sections for Griffin. Building on this capability, future work will seek to perform more detailed validation calculations. The ultimate goal is to evaluate both transient and multiphysics simulations of the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-throughput validation of phase formability and simulation accuracy of Cantor alloys

High-throughput methods enable accelerated discovery of novel materials in complex systems such as high-entropy alloys, which exhibit intricate phase stability across vast compositional spaces. Computational approaches, including Density Functional Theory (DFT) and calculation of phase diagrams (CALPHAD), facilitate screening of phase formability as a function of composition and temperature. However, the integration of computational predictions with experimental validation remains challenging in high-throughput studies. In this work, we introduce a quantitative confidence metric to assess the agreement between predictions and experimental observations, providing a quantitative measure of the confidence of machine learning models trained on either DFT or CALPHAD input in accounting for experimental evidence. The experimental dataset was generated via high-throughput in-situ synchrotron X-ray diffraction on compositionally varied FeNiMnCr alloy libraries, heated from room temperature to ~1000 °C. Agreement between the observed and predicted phases was evaluated using either temperature-independent phase classification or a model that incorporates a temperature-dependent probability of phase formation. This integrated approach demonstrates where strong overall agreement between computation and experiment exists, while also identifying key discrepancies, particularly in FCC/BCC predictions at Mn-rich regions to inform future model refinement.

36 - MATERIALS SCIENCE↗