Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accountability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Valuation Diagramming and Accounting of Transactive Energy Systems

Transactive energy (TE) systems support both economic and technical objectives of a power system including efficiency and reliability. TE systems utilize value-driven mechanisms to coordinate and balance responsive supply and demand in the power system. Economic performance of TE systems cannot be assessed without estimating their value. Estimating the potential value of transactive energy systems requires a systematic valuation methodology that can capture value exchanges among different stakeholders (i.e., actors) and ultimately estimate impact of one TE design and compare it against another one. Such a methodology can help decision makers choose the alternative that results in preferred outcomes. This paper presents a valuation methodology developed to assess value of TE systems. A TE use-case example is discussed, and metrics identified in the valuation process are quantified using a TE simulation program.

Makhmalbaf, Atefe↗

Accounting for herbaceous communities in process‐based models will advance our understanding of “grassy” ecosystems

Abstract Grassland and other herbaceous communities cover significant portions of Earth's terrestrial surface and provide many critical services, such as carbon sequestration, wildlife habitat, and food production. Forecasts of global change impacts on these services will require predictive tools, such as process‐based dynamic vegetation models. Yet, model representation of herbaceous communities and ecosystems lags substantially behind that of tree communities and forests. The limited representation of herbaceous communities within models arises from two important knowledge gaps: first, our empirical understanding of the principles governing herbaceous vegetation dynamics is either incomplete or does not provide mechanistic information necessary to drive herbaceous community processes with models; second, current model structure and parameterization of grass and other herbaceous plant functional types limits the ability of models to predict outcomes of competition and growth for herbaceous vegetation. In this review, we provide direction for addressing these gaps by: (1) presenting a brief history of how vegetation dynamics have been developed and incorporated into earth system models, (2) reporting on a model simulation activity to evaluate current model capability to represent herbaceous vegetation dynamics and ecosystem function, and (3) detailing several ecological properties and phenomena that should be a focus for both empiricists and modelers to improve representation of herbaceous vegetation in models. Together, empiricists and modelers can improve representation of herbaceous ecosystem processes within models. In so doing, we will greatly enhance our ability to forecast future states of the earth system, which is of high importance given the rapid rate of environmental change on our planet.

59 BASIC BIOLOGICAL SCIENCES↗

Terrestrial biosphere models may overestimate Arctic CO 2 assimilation if they do not account for decreased quantum yield and convexity at low temperature

Here, we measured the effect of temperature on the response of photosynthesis to irradiance in six Arctic plant species and determined the quantum yield of CO 2 fixation (Φ CO2 ) and the convexity factor (θ). We also determined leaf absorptance (α) from measured reflectance to calculate Φ CO2 on an absorbed light basis (Φ CO2.a ) and enable comparison with nine TBMs.

54 ENVIRONMENTAL SCIENCES↗

Building a better equation for electron transport estimated from Chl fluorescence: accounting for nonphotosynthetic light absorption

Chlorophyll fluorescence measurements of electron transport rate are an important companion of gas exchange analysis of photosynthesis. Detailed models allow prediction of gas exchange behavior based on fluorescence measurements, critical for converting low–throughput photosynthetic measurements to greater scales. Recently, a problem with using fluorescence–estimated electron transport rates in red vs blue light was discussed. The explanation was that high absorptance of blue light leads to saturation of photosystems near the light–exposed surface, but the red measuring beam may sample deeper in the leaf. In this case, fluorescence will report the quantum yield of photosystem II (ΦII) averaged from different photosystems than those that are important for the carbon–based quantum yield. The photosystems lower in the mesophyll will absorb less light, but will have a higher ΦII than tissues nearer the light–exposed surface, and so electron transport will be overestimated. Here, the overestimation caused by this sampling error will be higher for wavelengths of light that are more strongly absorbed, so it will be highest under blue actinic light and lowest under green actinic light. Based on this effect, some investigators are now choosing to use the minimum amount of blue needed to open stomata to minimize the overestimation of electron transport from blue light during gas exchange measurements.

59 BASIC BIOLOGICAL SCIENCES↗

Co-Optimization of Velocity and Charge-Depletion for Plug-In Hybrid Electric Vehicles: Accounting for Acceleration and Jerk Constraints

Abstract Recent advances in vehicle connectivity and automation technologies promote advanced control algorithms that co-optimize the longitudinal dynamics and powertrain operation of hybrid electric vehicles. Typically, a sequential optimization with the vehicle dynamics optimized followed by powertrain optimization is adopted to manage a number of complexities such as the inherent mixed-integer nature of the hybrid powertrain, the numerous state and control variables, the differing time scales of vehicle and powertrain subsystems, time-varying state constraints, and large horizon lengths. Instead, we solve the offline optimization problem in a centralize manner assuming exact knowledge of the lead vehicle's position over the entire trip by applying a discrete-time single shooting-based numerical approach, Discrete Mixed-Integer Shooting (DMIS), including a linearly increasing computational complexity to the problem horizon. In particular, the hierarchical problem structure is exploited to decompose the computationally intensive Hamiltonian minimization step into a set of low-dimensional optimizations. DMIS allows us to compute the direct fuel minimization problem including the vehicle and powertrain dynamics in a centralized manner to its full horizon while systematically tuning weighting factors that penalize passenger discomfort. For the first time, this study reveals that practically implemented sequential optimization exhibits similar fuel optimality as co-optimization when a certain level of passenger comfort is required.

Automation & Control Systems↗

An easy method to account for light scattering dose dependence in radiochromic films

Purpose: To date no detector can offer the unbeatable characteristics of film dosimetry in terms of spatial resolution and this is why it has been chosen by many institutions for treatment verification and, in that respect, radiochromic films are becoming increasingly popular due to their advantageous properties. It is the aim of this work to suggest an easy method to overcome one of the drawbacks in radiochromic film dosimetry associated with the scanning device, namely, the non-uniform dose dependent response, mainly due to the light scattering effect. Methods: The suggested procedure consists of building four correction matrices by sequentially scanning one, two, three, and four unexposed blank films. The color level of these four matrices is compatible with four points in the calibration curve dose range. Therefore, the dose dependent correction to the scanned irradiated film will be obtained by interpolating between the four correction matrices. Results: The validity of the suggested method is checked against an ion chamber 2D array. The use of the proposed flattening correction improves considerably the dose agreement when compared with the cases in which no correction is applied. Conclusions: The method showed to be fast and easy and practically overcomes the dependence on the dose of light scattering of flatbed scanners.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-G-BRD-05: Is “New Radiobiology” Needed to Account for the Anti-Tumor Efficacy of Hypofractionated Lung SBRT?

Purpose: The radiobiological understanding of SBRT is controversial. In this work, we modeled SBRT outcomes based on a previously published tumor control probability model, that incorporates hypoxia, proliferation and cell-cycle effects, in order to understand if non-traditional factors must be invoked to understand the efficacy of single and multiple fraction SBRT. Methods: We extracted cohorts from Mehta et al. (PRO (2012) 2:288) with easily identifiable fractionation parameters and commensurate outcome and prescription methods (n=2617). Each RT scheme was simulated in the model, and the surviving fraction (SF) of tumor cells was estimated. Another simulation was then carried out with conventional (2Gy/fx, 5fx/wk) fractionation until the same SF was achieved, resulting in model-derived equivalent dose in 2Gy/fx for α/β=10 (EQD2{sub 10}(model)). In the scatter plot of the outcome vs. EQD2{sub 10}(model), logistic regressions were performed for the total group or separate groups (conventional RT, SBRT with 3×10 fxs, and single fx SBRT), assuming the slope of the dose response curve (γ{sub 50}) of 1.5. Chi-squared tests were performed to test the validity of the fit. Results: With unfavorable hypoxic and cell-cycle effects, the effectiveness of typical SBRT regimes were predicted by the model to be significantly less effective than comparable standard fractionation regimes. The single-fraction TD{sub 50} was only 55% of the conventional fractionation TD{sub 50}, in units of EQD2{sub 10}(model). The dose response curves for the separate fractionation groups seems to represent the three different groups, with a high p-value for both SBRT groups. For the lower α/β of 3, the same patterns were observed with smaller differences among the groups. Conclusion: Based on classical radiobiology, the dose response relation of SBRT was evaluated and compared with conventional RT. Observed SBRT outcomes are inconsistent with classical radiobiology principles, suggesting the possible other effects, which increases as the fractional dose increases.

60 APPLIED LIFE SCIENCES↗

SU-D-213-04: Accounting for Volume Averaging and Material Composition Effects in An Ionization Chamber Array for Patient Specific QA

Purpose: This study explores novel methods to address two significant challenges affecting measurement of patient-specific quality assurance (QA) with IBA’s Matrixx Evolution™ ionization chamber array. First, dose calculation algorithms often struggle to accurately determine dose to the chamber array due to CT artifact and algorithm limitations. Second, finite chamber size and volume averaging effects cause additional deviation from the calculated dose. Methods: QA measurements were taken with the Matrixx positioned on the treatment table in a solid-water Multi-Cube™ phantom. To reduce the effect of CT artifact, the Matrixx CT image set was masked with appropriate materials and densities. Individual ionization chambers were masked as air, while the high-z electronic backplane and remaining solid-water material were masked as aluminum and water, respectively. Dose calculation was done using Varian’s Acuros XB™ (V11) algorithm, which is capable of predicting dose more accurately in non-biologic materials due to its consideration of each material’s atomic properties. Finally, the exported TPS dose was processed using an in-house algorithm (MATLAB) to assign the volume averaged TPS dose to each element of a corresponding 2-D matrix. This matrix was used for comparison with the measured dose. Square fields at regularly-spaced gantry angles, as well as selected patient plans were analyzed. Results: Analyzed plans showed improved agreement, with the average gamma passing rate increasing from 94 to 98%. Correction factors necessary for chamber angular dependence were reduced by 67% compared to factors measured previously, indicating that previously measured factors corrected for dose calculation errors in addition to true chamber angular dependence. Conclusion: By comparing volume averaged dose, calculated with a capable dose engine, on a phantom masked with correct materials and densities, QA results obtained with the Matrixx Evolution™ can be significantly improved. In addition, necessary correction factors are reduced, allowing for more reliable and meaningful patient-specific QA measurements.

60 APPLIED LIFE SCIENCES↗

SU-E-T-574: Novel Chance-Constrained Optimization in Intensity-Modulated Proton Therapy Planning to Account for Range and Patient Setup Uncertainties

Purpose: We propose to apply a probabilistic framework, namely chanceconstrained optimization, in the intensity-modulated proton therapy (IMPT) planning subject to range and patient setup uncertainties. The purpose is to hedge against the influence of uncertainties and improve robustness of treatment plans. Methods: IMPT plans were generated for a typical prostate patient. Nine dose distributions are computed — the nominal one and one each for ±5mm setup uncertainties along three cardinal axes and for ±3.5% range uncertainty. These nine dose distributions are supplied to the solver CPLEX as chance constraints to explicitly control plan robustness under these representative uncertainty scenarios with certain probability. This probability is determined by the tolerance level. We make the chance-constrained model tractable by converting it to a mixed integer optimization problem. The quality of plans derived from this method is evaluated using dose-volume histogram (DVH) indices such as tumor dose homogeneity (D5% – D95%) and coverage (D95%) and normal tissue sparing like V70 of rectum, V65, and V40 of bladder. We also compare the results from this novel method with the conventional PTV-based method to further demonstrate its effectiveness Results: Our model can yield clinically acceptable plans within 50 seconds. The chance-constrained optimization produces IMPT plans with comparable target coverage, better target dose homogeneity, and better normal tissue sparing compared to the PTV-based optimization [D95% CTV: 67.9 vs 68.7 (Gy), D5% – D95% CTV: 11.9 vs 18 (Gy), V70 rectum: 0.0 % vs 0.33%, V65 bladder: 2.17% vs 9.33%, V40 bladder: 8.83% vs 21.83%]. It also simultaneously makes the plan more robust [Width of DVH band at D50%: 2.0 vs 10.0 (Gy)]. The tolerance level may be varied to control the tradeoff between plan robustness and quality. Conclusion: The chance-constrained optimization generates superior IMPT plan compared to the PTV-based optimization with explicit control of plan robustness. NIH/NCI K25CA168984, Eagles Cancer Research Career Development, The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, Mayo ASU Seed Grant, and The Kemper Marley Foundation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-337: Accounting for Patient Motion During Volumetric Modulated Ac Therapy (VMAT) Planning for Post Mastectomy Chest Wall Irradiation

Purpose: To evaluate two dose optimization strategies for maintaining target volume coverage of inversely-planned post mastectomy radiotherapy (PMRT) plans during patient motion. Methods: Five patients previously treated with VMAT for PMRT at our clinical were randomly selected for this study. For each patient, two plan optimization strategies were compared. Plan 1 was optimized to a volume that included the physician’s planning target volume (PTV) plus an expansion up to 0.3 cm from the bolus surface. Plan 2 was optimized to the PTV plus an expansion up to 0.3 cm from the patient surface (i.e., not extending into the bolus). VMAT plans were optimized to deliver 95% of the prescription to 95% of the PTV while sparing organs at risk based on clinical dose limits. PTV coverage was then evaluated following the simulation of patient shifts by 1.0 cm in the anterior and posterior directions using the treatment planning system. Results: Posterior patient shifts produced a difference in D95% of around 11% in both planning approaches from the non-shifted dose distributions. Coverage of the medial and lateral borders of the evaluation volume was reduced in both the posteriorly shifted plans (Plan 1 and Plan 2). Anterior patient shifts affected Plan 2 more than Plan 1 with a difference in D95% of 1% for Plan 1 versus 6% for Plan 2 from the non-shifted dose distributions. The least variation in PTV dose homogeneity for both shifts was obtained with Plan 1. However, all posteriorly shifted plans failed to deliver 95% of the prescription to 95% of the PTV. Whereas, only a few anteriorly shifted plans failed this criteria. Conclusion: The results of this study suggest both planning volume methods are sensitive to patient motion, but that a PTV extended into a bolus volume is slightly more robust for anterior patient shifts.

60 APPLIED LIFE SCIENCES↗

TU-H-207A-01: Development of Conversion Factors to Account for Different CTDI Phantom Setups On a Wide-Beam CT Scanner

Purpose: A fundamental measure performed during an annual physics CT evaluation confirms that system displayed CTDIvol nearly matches the independently measured value in phantom. For wide-beam (z-direction) CT scanners, AAPM Report 111 defined an ideal measurement method; however, the method often lacks practicality. The purpose of this preliminary study is to develop a set of conversion factors for a wide-beam CT scanner, relating the CTDIvol measured with a conventional setup (single CTDI phantom) versus the AAPM Report 111 approach (three abutting CTDI phantoms). Methods: For both the body CTDI and head CTDI, two acquisition setups were used: A) conventional single phantom and B) triple phantom. Of primary concern were the larger nominal beam widths for which a standard CTDI phantom setup would not provide adequate scatter conditions. Nominal beam width (160 or 120 mm) and kVp (100, 120, 140) were modulated based on the underlying clinical protocol. Exposure measurements were taken using a CT pencil ion chamber in the center and 12 o’clock position, and CTDIvol was calculated with ‘nT’ limited to 100 mm. A conversion factor (CF) was calculated as the ratio of CTDIvol measured in setup B versus setup A. Results: For body CTDI, the CF ranged from 1.04 up to 1.10, indicating a 4–10% difference between usage of one and three phantoms. For a nominal beam width of 160 mm, the CF did vary with selected kVp. For head CTDI at nominal beam widths of 120 and 160 mm, the CF was 1.00 and 1.05, respectively, independent of the kVp used (100, 120, and 140). Conclusions: A clear understanding of the manufacturer method of estimating the displayed CTDIvol is important when interpreting annual test results, as the acquisition setup may lead to an error of up to 10%. With appropriately defined CF, single phantom use is feasible.

07 ISOTOPE AND RADIATION SOURCES↗

WE-H-202-03: Accounting for Large Geometric Changes During Radiotherapy

Deformable image registration has now been commercially available for several years, with solid performance in a number of sites and for several applications including contour and dose mapping. However, more complex applications have arisen, such as assessing response to radiation therapy over time, registering images pre- and post-surgery, and auto-segmentation from atlases. These applications require innovative registration algorithms to achieve accurate alignment. The goal of this session is to highlight emerging registration technology and these new applications. The state of the art in image registration will be presented from an engineering perspective. Translational clinical applications will also be discussed to tie these new registration approaches together with imaging and radiation therapy applications in specific diseases such as cervical and lung cancers. Learning Objectives: To understand developing techniques and algorithms in deformable image registration that are likely to translate into clinical tools in the near future. To understand emerging imaging and radiation therapy clinical applications that require such new registration algorithms. Research supported in part by the National Institutes of Health under award numbers P01CA059827, R01CA166119, and R01CA166703. Disclosures: Phillips Medical systems (Hugo), Roger Koch (Christensen) support, Varian Medical Systems (Brock), licensing agreements from Raysearch (Brock) and Varian (Hugo).; K. Brock, Licensing Agreement - RaySearch Laboratories. Research Funding - Varian Medical Systems; G. Hugo, Research grant from National Institutes of Health, award number R01CA166119.; G. Christensen, Research support from NIH grants CA166119 and CA166703 and a gift from Roger Koch. There are no conflicts of interest.

60 APPLIED LIFE SCIENCES↗

TH-CD-209-04: Fuzzy Robust Optimization in Intensity-Modulated Proton Therapy Planning to Account for Range and Patient Setup Uncertainties

Purpose: We propose to apply a robust optimization model based on fuzzy-logic constraints in the intensity-modulated proton therapy (IMPT) planning subject to range and patient setup uncertainties. The purpose is to ensure the plan robustness under uncertainty and obtain the best trade-off between tumor dose coverage and organ-at-risk(OAR) sparing. Methods: Two IMPT plans were generated for 3 head-and-neck cancer patients: one used the planning target volume(PTV) method; the other used the fuzzy robust optimization method. In the latter method, nine dose distributions were computed - the nominal one and one each for ±3mm setup uncertainties along three cardinal axes and for ±3.5% range uncertainty. For tumors, these nine dose distributions were explicitly controlled by adding hard constraints with adjustable parameters. For OARs, fuzzy constraints that allow the dose to vary within a certain range were used so that the tumor dose distribution was guaranteed by minimum compromise of that of OARs. We rendered this model tractable by converting the fuzzy constraints to linear constraints. The plan quality was evaluated using dose-volume histogram(DVH) indices such as tumor dose coverage(D95%), homogeneity(D5%-D95%), plan robustness(DVH band at D95%), and OAR sparing like D1% of brain and D1% of brainstem. Results: Our model could yield clinically acceptable plans. The fuzzy-logic robust optimization method produced IMPT plans with comparable target dose coverage and homogeneity compared to the PTV method(unit: Gy[RBE]; average[min, max])(CTV D95%: 59 [52.7, 63.5] vs 53.5[46.4, 60.1], CTV D5% - D95%: 11.1[5.3, 18.6] vs 14.4[9.2, 21.5]). It also generated more robust plans(CTV DVH band at D95%: 3.8[1.2, 5.6] vs 11.5[6.2, 16.7]). The parameters of tumor constraints could be adjusted to control the tradeoff between tumor coverage and OAR sparing. Conclusion: The fuzzy-logic robust optimization generates superior IMPT with minimum compromise of OAR sparing. This research was supported by the National Cancer Institute Career Developmental Award K25CA168984, by the Fraternal Order of Eagles Cancer Research Fund Career Development Award, by The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, by Mayo Arizona State University Seed Grant, and by The Kemper Marley Foundation. eRA Person ID(s) for the Principal Investigator: 11017970 (Research Supported by National Institutes of Health)

60 APPLIED LIFE SCIENCES↗