Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “aberrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Differentiation and Genomic Instability in a Human Mammary Cell Model

Harvest of prophylactic mastectomy specimens from an obligate heterozygote for ataxia-telangiectasia provided autologous fibroblasts as well epithelial cells (HMEC). The routine availability of these autologous cells has provided an opportunity to study cell-cell interactions in coculture and monoculture, and in 3-dimensional cultures grown in the NASA rotating bioreactor. HMEC and stromal fibroblasts grown in 2-dimensional monoculture were both observed to produce extracellular matrix. Similar matrix was encountered in 3-dimensional cultures containing HMEC. Metaphases were analyzed. For stromal fibroblasts, genomic aberrations were found in 18% of metaphase spreads. For HMEC, aberrations were greater such that a majority were found to be abnormal. The level of genomic instability determined for these noncancerous cells in 2-dimensional monoculture should be useful for generating a human cell model that can correlate the effects of differentiation in 3-dimensional coculture on the level of genomic instability.

Richmond, R.↗

Adjustable Focus Optical Correction Lens (AFOCL)

This report describes the activities and accomplishments along with the status of the characterization of a PLZT-based Adjustable Focus Optical Correction Lens (AFOCL) test device. The activities described in this report were undertaken by members of the Center for Applied Optics (CAO) at the University of Alabama in Huntsville (UAH) under NASA Contract NAS8-00188. The effort was led by Dr. Bruce Peters as the Principal Investigator and supported by Dr. Patrick Reardon, Ms. Deborah Bailey, and graduate student Mr. Jeremy Wong. The activities outlined for the first year of the contract were to identify vendors and procure a test device along with performing the initial optical characterization of the test device. This activity has been successfully executed and test results are available and preliminary information was published at the SPIE Photonics West Conference in San Jose, January 2001. The paper, "Preliminary investigation of an active PLZT lens," was well received and generated response with several questions from the audience. A PLZT test device has been commercially procured from an outside vendor: The University of California in San Diego (UCSD) in partnership with New Interconnect Packaging Technologies (NIPT) Inc. The device has been subjected to several tests to characterize the optical performance of the device at wavelengths of interest. The goal was to evaluate the AFOCL similar to a conventional lens and measure any optical aberrations present due to the PLZT material as a deviation in the size of the diffraction limited spot (blur), the presence of diffracted energy into higher orders surrounding the focused spot (a variation in Strehl), and/or a variation or spread in the location of the focused energy away from the optical axis (a bias towards optical wedge, spherical, comma, or other higher order aberrations). While data has been collected indicative of the imaging quality of the AFOCL test device, it was not possible to fully characterize the optical performance of the AFOCL alone because there were significant optical distortions due to fabrication related issues.

Peters, Bruce R.↗

Human Peripheral Blood Mononuclear Cells Cultured in Normal and Hyperglycemic Media in Simulated Microgravity Using NASA Bioreactors

We sought answers to several questions this summer at NASA Johnson Space Center. Initial studies involved the in vitro culture of human peripheral blood mononuclear in cells in different conditioned culture media. Several human cancer clones were similarly studied to determine responses to aberrant glycosylation by the argon laser. The cells were grown at unit gravity in flasks and in simulated microgravity using NASA bioreactors. The cells in each instance were analyzed by flow cytometry. Cell cycle analysis was acquired by staining nuclear DNA with propidium iodide. Responses to the laser stimulation was measured by observing autofluorescence emitted in the green and red spectra after stimulation. Extent of glycosylation correlated with the intensity of the laser stimulated auto-fluorescence. Our particular study was to detect and monitor aberrant glycosylation and its role in etiopathogenesis. Comparisons were made between cells known to be neoplastic and normal cell controls using the same Laser Induced Autofluorescence technique. Studies were begun after extensive literature searches on using the antigen presenting potential of dendritic cells to induce proliferation of antigen specific cytotoxic T-cells. The Sendai virus served as the antigen. Our goal is to generate sufficient numbers of such cells in the simulated microgravity environment for use in autologous transplants of virally infected individuals including those positive for hepatitis and HIV.

Lawless, DeSales↗

Induction of genomic instability in TK6 human lymphoblasts exposed to 137Cs gamma radiation: comparison to the induction by exposure to accelerated 56Fe particles

The induction of genomic instability in TK6 human lymphoblasts by exposure to (137)Cs gamma radiation was investigated by measuring the frequency and characteristics of unstable clones isolated approximately 36 generations after exposure. Clones surviving irradiation and control clones were analyzed for 17 characteristics including chromosomal aberrations, growth defects, alterations in response to a second irradiation, and mutant frequencies at the thymidine kinase and Na(+)/K(+) ATPase loci. Putative unstable clones were defined as those that exhibited a significant alteration in one or more characteristics compared to the controls. The frequency and characteristics of the unstable clones were compared in clones exposed to (137)Cs gamma rays or (56)Fe particles. The majority of the unstable clones isolated after exposure to either gamma rays or (56)Fe particles exhibited chromosomal instability. Alterations in growth characteristics, radiation response and mutant frequencies occurred much less often than cytogenetic alterations in these unstable clones. The frequency and complexity of the unstable clones were greater after exposure to (56)Fe particles than to gamma rays. Unstable clones that survived 36 generations after exposure to gamma rays exhibited increases in the incidence of dicentric chromosomes but not of chromatid breaks, whereas unstable clones that survived 36 generations after exposure to (56)Fe particles exhibited increases in both chromatid and chromosome aberrations.

Non-NASA Center↗

On the Fringe Field of Wide Angle LC Optical Phased Array

For free space laser communication, light weighted large deployable optics is a critical component for the transmitter. However, such an optical element will introduce large aberrations due to the fact that the surface figure of the large optics is susceptable to deformation in the space environment. We propose to use a high-resolution liquid crystal spatial light modulator to correct for wavefront aberrations introduced by the primary optical element, and to achieve very fine beam steering and shaping at the same time. A 2-D optical phased array (OPA) antenna based on a Liquid Crystal on Silicon (LCOS) spatial light modulator is described. This device offers a combination of low cost, high resolution, high accuracy, high diffraction efficiency at video speed. To quantitatively understand the influence factor of the different design parameters, a computer simulation of the device is given by the 2-D director simulation and the Finite Difference Time domain (FDTD) simulation. For the 1-D OPA, we define the maximum steering angle to have a grating period of 8 pixel/reset scheme; as for larger steering angles than this criterion, the diffraction efficiency drops dramatically. In this case, the diffraction efficiency of 0.86 and the Strehl ratio of 0.9 are obtained in the simulation. The performance of the device in achieving high resolution wavefront correction and beam steering is also characterized experimentally.

Wang, Xighua↗

Effects of Optical Artifacts in a Laser-Based Spacecraft Navigation Sensor

Testing of the Advanced Video Guidance Sensor (AVGS) used for proximity operations navigation on the Orbital Express ASTRO spacecraft exposed several unanticipated imaging system artifacts and aberrations that required correction to meet critical navigation performance requirements. Mitigation actions are described for a number of system error sources, including lens aberration, optical train misalignment, laser speckle, target image defects, and detector nonlinearity/noise characteristics. Sensor test requirements and protocols are described, along with a summary of test results from sensor confidence tests and system performance testing.

LeCroy, Jerry E.↗

Metrology system for the Terrestrial Planet Finder Coronagraph

The Terrestrial Planet Finder (TPF) employs an aggressive coronagraph designed to obtain better than 1e-10 contrast inside the third Airy ring. Minute changes in low-order aberration content scatter significant light at this position. One implication is the requirement to control low-order aberrations induced by motion of the secondary mirror relative to the primary mirror; sub-nanometer relative positional stability is required. We propose a 6-beam laser truss to monitor the relative positions of the two mirrors. The truss is based on laser metrology developed for the Space Interferometry Mission.

Terrestrial Planet Finder (TPF)↗

Effects of Optical Artifacts in a Laser-Based Spacecraft Navigation Sensor

Testing of the Advanced Video Guidance Sensor (AVGS) used for proximity operations navigation on the Orbital Express ASTRO spacecraft exposed several unanticipated imaging system artifacts and aberrations that required correction to meet critical navigation performance requirements. Mitigation actions are described for a number of system error sources, including lens aberration, optical train misalignment, laser speckle, target image defects, and detector nonlinearity/noise characteristics. Sensor test requirements and protocols are described, along with a summary of test results from sensor confidence tests and system performance testing.

LeCroy, Jerry E.↗

Zernike-like Orthogonal Basis Functions for Wavefront Characterization over Sampled, Irregular Apertures

For optical systems with circular apertures, wavefronts are often analyzed using Zernike polynomials, and individual Zernike functions are associated with familiar optical aberrations. For systems with noncircular apertures, or in practical situations in which wavefronts are measured at a limited number of points in the aperture, the Zernike polynomials are no longer an orthogonal basis for the measured data. Although there are an endless number of ways to create a basis for such measured data, a "Zernike-like" basis is useful to connect with our experience with the usual optical aberrations. In this paper, the steps required to identify a Zernike-like basis for wavefronts over sampled, irregular apertures are presented, based on the Gram-Schmidt orthogonalization technique. The benefits of analyzing optical wavefronts using an orthogonal basis specific to an optical system's aperture shape and wavefront sampling, instead of using the traditional Zernike polynomials, are detailed in two examples, from image-based wavefront sensing on a segmented-aperture telescope (the James Webb Space Telescope Testbed Telescope at Ball Aerospace) and from interferometer characterization for surface metrology of a hexagonal mirror segment.

Aronstein, David L.↗

Effects of Optical Artifacts in a Laser-Based Spacecraft Navigation Sensor

Testing Of the Advanced Video Guidance Sensor (AVGS) used for proximity operations navigation on the Orbital Express ASTRO spacecraft exposed several unanticipated imaging system artifacts and aberrations that required correction, to meet critical navigation performance requirements. Mitigation actions are described for a number of system error sources, including lens aberration, optical train misalignment, laser speckle, target image defects, and detector nonlinearity/noise characteristics. Sensor test requirements and protocols are described, along with a summary ,of test results from sensor confidence tests and system performance testing.

LeCroy, Jerry E.↗

Testing Prospects for Reliable Diatom Nanotechnology in Microgravity

The worldwide effort to grow nanotechnology, rather than use lithography, focuses on diatoms, single cell eukaryotic algae with ornate silica shells, which can be replaced by oxides and ceramics, or reduced to elemental silicon, to create complex nanostructures with compositions of industrial and electronics importance. Diatoms produce an enormous variety of structures, some of which are microtubule dependent and perhaps sensitive to microgravity. The NASA Single Loop for Cell Culture (SLCC) for culturing and observing microorganisms permits inexpensive, low labor in-space experiments. We propose to send up to the International Space Station diatom cultures of the three diatom species whose genomes are being sequenced, plus the giant diatoms of Antarctica (up to 2 mm diameter for a single cell) and the unique colonial diatom, Bacillaria paradoxa. Bacillaria cells move against each other in partial synchrony, like a sliding deck of cards, by a microfluidics mechanism. Will normal diatoms have aberrant pattern and shape or motility compared to ground controls? The generation time is typically one day, so that many generations may be examined from one flight. Rapid, directed evolution may be possible running the SLCC as a compustat. The shell shapes and patterns are preserved in hard silica, so that the progress of normal and aberrant morphogenesis may be followed by drying samples on a moving filter paper "diatom tape recorder". With a biodiversity of 100,000 distinct species, diatom nanotechnology may offer a compact and portable nanotechnology toolkit for exploration anywhere.

Gordon, Richard↗

Spherical mirror grazing incidence x-ray optics

An optical system for x-rays combines at least two spherical or near spherical mirrors for each dimension in grazing incidence orientation to provide the functions of a lens in the x-ray region. To focus x-ray radiation in both the X and the Y dimensions, one of the mirrors focusses the X dimension, a second mirror focusses the Y direction, a third mirror corrects the X dimension by removing comatic aberration and a fourth mirror corrects the Y dimension. Spherical aberration may also be removed for an even better focus. The order of the mirrors is unimportant.

Cash, Jr., Webster C.↗

Real-time analysis keratometer

A computer assisted keratometer in which a fiducial line pattern reticle illuminated by CW or pulsed laser light is projected on a corneal surface through lenses, a prismoidal beamsplitter quarterwave plate, and objective optics. The reticle surface is curved as a conjugate of an ideal corneal curvature. The fiducial image reflected from the cornea undergoes a polarization shift through the quarterwave plate and beamsplitter whereby the projected and reflected beams are separated and directed orthogonally. The reflected beam fiducial pattern forms a moire pattern with a replica of the first recticle. This moire pattern contains transverse aberration due to differences in curvature between the cornea and the ideal corneal curvature. The moire pattern is analyzed in real time by computer which displays either the CW moire pattern or a pulsed mode analysis of the transverse aberration of the cornea under observation, in real time. With the eye focused on a plurality of fixation points in succession, a survey of the entire corneal topography is made and a contour map or three dimensional plot of the cornea can be made as a computer readout in addition to corneal radius and refractive power analysis.

Adachi, Iwao P.↗

Non-DBS DNA Repair Genes Regulate Radiation-induced Cytogenetic Damage Repair and Cell Cycle Progression

Changes of gene expression profile are one of the most important biological responses in living cells after ionizing radiation (IR) exposure. Although some studies have shown that genes up-regulated by IR may play important roles in DNA damage repair, the relationship between the regulation of gene expression by IR, particularly genes not known for their roles in DSB repair, and its impact on cytogenetic responses has not been systematically studied. In the present study, the expression of 25 genes selected on the basis of their transcriptional changes in response to IR was individually knocked down by transfection with small interfering RNA in human fibroblast cells. The purpose of this study is to identify new roles of these selected genes on regulating DSB repair and cell cycle progression , as measured in the micronuclei formation and chromosome aberration. In response to IR, the formation of MN was significantly increased by suppressed expression of 5 genes: Ku70 in the DSB repair pathway, XPA in the NER pathway, RPA1 in the MMR pathway, and RAD17 and RBBP8 in cell cycle control. Knocked-down expression of 4 genes (MRE11A, RAD51 in the DSB pathway, SESN1, and SUMO1) significantly inhibited cell cycle progression, possibly because of severe impairment of DNA damage repair. Furthermore, loss of XPA, P21, or MLH1 expression resulted in both significantly enhanced cell cycle progression and increased yields of chromosome aberrations, indicating that these gene products modulate both cell cycle control and DNA damage repair. Most of the 11 genes that affected cytogenetic responses are not known to have clear roles influencing DBS repair. Nine of these 11 genes were up-regulated in cells exposed to gamma radiation, suggesting that genes transcriptionally modulated by IR were critical to regulate the biological consequences after IR.

Zhang, Ye↗

Loss of Telomeres in the Progeny of Human Lymphocytes Exposed to Energetic Heavy Ions

We have used cross-species multi-color banding (RxFISH) combined with telomere FISH probes, to measure chromosomal aberrations in the progeny of human peripheral blood lymphocytes exposed to ionizing radiation. Accelerated iron particles (energy 1 GeV/nucleon) induced many more terminal deletions than the same dose of gamma-rays. We found that truncated chromosomes without telomeres could be transmitted for at least three cell cycles following exposure, and represented about 10% of all aberrations observed in the progeny of cells exposed to iron ions. High energy heavy ions generate the most significant health risk for human space exploration and the results suggest that telomere loss may be the leading mechanism for their high efficiency in the induction of late effects.

Cucinotta, F.A.↗

The Influence of Shielding on the Biological Effectiveness of Accelerated Particles for the Induction of Chromosome Damages

Chromosome damage was assessed in human peripheral blood lymphocytes after in vitro exposure to the either Si-28 (490 or 600 MeV/n), Ti-48 (1000 MeV/n), or Fe-56 (600, 1000, or 5000 MeV/n). LET values for these ions ranged from approximately 50 to 174 keV/micrometers and doses ranged from 10 to 200 cGy. The effect of either aluminum or polyethylene shielding on the induction of chromosome aberrations was investigated for each ion. Chromosome exchanges were measured using fluorescence in situ hybridization (FISH) with whole chromosome probes in cells collected 48-56 hours after irradiation using a chemical-induced premature chromosome condensation (PCC) technique. The yield of chromosomal aberrations increased linearly with dose and the relative biological effectiveness (RBE) for the primary beams, estimated from the initial slope of the dose response curve for total chromosomal exchanges with respect to gamma-rays, ranged from 14 to 35. The RBE values increased with LET, reaching a maximum for the 1 GeV/n Fe ions with LET of 150 keV/micrometers, and decreased with further increases in LET. When LET of the primary beam was in the region of increasing RBE (i.e. below approximately 100 keV/micrometers), the addition of shielding material increased the effectiveness per unit dose. Whereas shielding decreased the effectiveness per unit dose when the LET of the primary particle beam was higher than 150 keV/micrometers.

George, K.↗

The Effect of a Mars Mission on Chromosome Damage in the Blood Lymphocytes of Astronauts

The radiation environment encountered during a manned mission to Mars will lead to significant elevation of biological damage in astronauts. Here we present estimates of the increased frequencies of chromosome aberrations in the peripheral blood lymphocytes of astronauts after a hypothetical Mars mission using radiation dose estimations and lymphocyte biology. Results will incorporate previously published data on in vivo induced chromosome damage in the blood lymphocytes of crewmembers after ISS and Mir missions, along with recent findings on the time dependant decay of chromosome aberrations after space flight.

George, Kerry A.↗

The Effects of Instrumental Elliptical Polarization on Stellar Point Spread Function Fine Structure

We present procedures and preliminary results from a study on the effects of instrumental polarization on the fine structure of the stellar point spread function (PSF). These effects are important to understand because the the aberration caused by instrumental polarization on an otherwise diffraction-limited will likely have have severe consequences for extreme high contrast imaging systems such as NASA's planned Terrestrial Planet Finder (TPF) mission and the proposed NASA Eclipse mission. The report here, describing our efforts to examine these effects, includes two parts: 1) a numerical analysis of the effect of metallic reflection, with some polarization-specific retardation, on a spherical wavefront; 2) an experimental approach for observing this effect, along with some preliminary laboratory results. While the experimental phase of this study requires more fine-tuning to produce meaningful results, the numerical analysis indicates that the inclusion of polarization-specific phase effects (retardation) results in a point spread function (PSF) aberration more severe than the amplitude (reflectivity) effects previously recorded in the literature.

high angular resolution↗