Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Wind Farm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

A time‐varying formulation of the curled wake model within the FAST.Farm framework

Abstract In this article, we present a time‐varying formulation of the curled wake model that we implemented in FAST.Farm. The curled wake model, originally developed for steady‐state conditions, is used to produce realistic wake profiles behind a wind turbine in yawed (or skewed) conditions. We begin by introducing the key elements of the FAST.Farm framework. Then, after briefly summarizing the original wake dynamics formulation of FAST.Farm based on a polar wake profile, we present the new time‐varying formulation of the curled wake model, compare the two, and highlight the differences with the original curled wake model. After discussing some implementation details, we present different applications with increasing levels of complexity: single turbine with uniform and turbulent inflow, fixed and transient yaw, and multiple turbines. We verify our results using the original FAST.Farm implementation and large‐eddy simulations. The results with the new curled wake model are improved compared to the original implementation, as they include cross‐flow velocities and wake asymmetry. Yet, large‐eddy simulation results show a more pronounced lateral convection of the wake and a stronger concentration of vorticity at the top vortex. The new curled wake implementation in FAST.Farm should enable the calculation of not only generator power but also wind turbine structural loads for applications involving intentional or unintentional skewed flow and wind‐farm control involving wake steering.

17 WIND ENERGY↗

Sensitivity Analysis of Modal Parameters of a Jacket Offshore Wind Turbine to Operational Conditions

Accurate estimation of offshore wind turbine (OWT) modal parameters has a prominent effect on the design loads, lifetime prediction, and dynamic response of the system. Modal parameters can vary during the operation of OWTs. This paper studies the variation and sensitivity analysis of an OWT’s modal parameters with respect to operational and environmental conditions. Three finite element models of a jacket-supported OWT at the Block Island Wind Farm are created within the OpenSees, SAP2000, and OpenFAST platforms and validated using experimental measurements. The OpenFAST model is used to simulate the modal parameters of the turbine under various wind speed, rotor speed, power, yaw angle, mean sea level, blade pitch angle, and soil spring values. The model-predicted modal parameters of the first fore–aft (FA) and side–side (SS) modes are compared to those identified from experimental measurements. Results from the simulations show that the first FA natural frequency and damping ratio mostly depend on the rotor speed and wind speed, respectively, while yaw angle and mean sea level do not have a visible effect. It is observed that there is about 8% stiffening in the first FA frequency and an aerodynamic damping of 7.5% during the operation of the OWT.

17 WIND ENERGY↗

Effect of Wind Gusts on Local Run-of-River Hydro Plants

In this work, we focus on the integration of wind farms in a hydro dominated power system, and analyze the challenges and solutions associated with this integration. Due to sudden increase in wind power, the system frequency can increase, causing excessive reduction in the run-of-river (ROR) system’s power. This can result in damage to the physical structure due to water level violations and cause issues for downstream customers. To prevent excessive and prolonged ROR power deviations, and to prevent tie-line deviations, we are proposing a wind-hydro centralized coordination scheme, which is not existing currently. The controller showed promising results by reducing the system frequency extrema by 0.8Hz.

13 HYDRO ENERGY↗

Large-eddy simulations of turbulent flows in arrays of helical- and straight-bladed vertical-axis wind turbines

Effects of helical-shaped blades on the flow characteristics and power production of finite-length wind farms composed of vertical-axis wind turbines (VAWTs) are studied numerically using large-eddy simulation (LES). Two helical-bladed VAWTs (with opposite blade twist angles) are studied against one straight-bladed VAWT in different array configurations with coarse, intermediate, and tight spacings. Statistical analysis of the LES data shows that the helical-bladed VAWTs can improve the mean power production in the fully developed region of the array by about 4.94%–7.33% compared with the corresponding straight-bladed VAWT cases. The helical-bladed VAWTs also cover the azimuth angle more smoothly during the rotation, resulting in about 47.6%–60.1% reduction in the temporal fluctuation of the VAWT power output. Using the helical-bladed VAWTs also reduces the fatigue load on the structure by significantly reducing the spanwise bending moment (relative to the bottom base), which may improve the longevity of the VAWT system to reduce the long-term maintenance cost.

17 WIND ENERGY↗

Wind Electrolysis: Hydrogen Cost Optimization

This report describes a hydrogen production cost analysis of a collection of optimized central wind based water electrolysis production facilities. The basic modeled wind electrolysis facility includes a number of low temperature electrolyzers and a co-located wind farm encompassing a number of 3MW wind turbines that provide electricity for the electrolyzer units.

08 HYDROGEN↗

U.S. Virgin Islands Wind Resources Update 2014

This report summarized the data collected from two 60-meter (m) meteorological towers (met masts or met towers) and three sonic detection and ranging (SODAR) units on St. Thomas and St. Croix in 2012 and 2013. These results are an update to the previous feasibility study; the collected data are critical to the successful development of a wind project at either site (Lantz et al. 2012). The wind maps for the territory were updated based on these improved data. The National Renewable Energy Laboratory (NREL) conducted measurements from met towers and SODAR units for several locations in the U.S. Virgin Islands (USVI). Both met masts were deployed for more than a year and produced high-quality data (standard industry practice in the wind industry). The Longford (St. Croix) and Bovoni (St. Thomas) sites are estimated to have long-term corrected wind speeds that exceed 7 meters per second (m/s), which may produce financially viable wind projects for both sites. The levelized cost of energy for both sites was estimated at $\$$0.08–$\$$0.14 per kilowatt-hour for typical utility-scale wind turbine with the uncertainty in the estimate driven by uncertainty in the installed capital costs of the proposed wind farms. These estimates assume that the wind production tax credit is not reinstated, but that accelerated depreciation is in place.

17 WIND ENERGY↗

Executive Summary for the SNL SWIFT V27 Wind Turbine Dynamic Characterization

This final report summarizes ATA Engineering Inc.'s experimental dynamic characterization of the Sandia National Laboratories (SNL) Scaled Wind Farm Technology (SWIFT) Vestas 27 (V27) wind turbine components and fully assembled turbines. Testing was performed at SNL's SWIFT facility in Lubbock, Texas, from October 2012 through June 2013.Dynamic testing consisted of modal testing of the individual blades, the towers in a free-free boundary condition, the towers bolted to the foundations, and the fully assembled wind turbines. Additionally, modal testing was performed on a hub and two nacelles to determine the mass and inertia properties of these components. Details on these tests can be found in their respective reports.

17 WIND ENERGY↗

Wind Development on Tribal Lands

Background: The Rosebud Sioux Tribe (RST) is located in south central South Dakota near the Nebraska border. The nearest community of size is Valentine, Nebraska. The RST is a recipient of several Department of Energy grants, written by Distributed Generation Systems, Inc. (Disgen), for the purposes of assessing the feasibility of its wind resource and subsequently to fund the development of the project. Disgen, as the contracting entity to the RST for this project, has completed all the pre-construction activities, with the exception of the power purchase agreement and interconnection agreement, to commence financing and construction of the project. The focus of this financing is to maximize the economic benefits to the RST while achieving commercially reasonable rates of return and fees for the other parties involved. Each of the development activities required and its status is discussed below. Land Resource: The Owl Feather War Bonnet 30 MW Wind Project is located on RST Tribal Trust Land of approximately 680 acres adjacent to the community of St. Francis, South Dakota. The RST Tribal Council has voted on several occasions for the development of this land for wind energy purposes, as has the District of St. Francis. Actual footprint of wind farm will be approx. 50 acres. Wind Resource Assessment: The wind data has been collected from the site since May 1, 2001 and continues to be collected and analyzed. The latest projections indicate a net capacity factor of 42% at a hub height of 80 meters. The data has been collected utilizing an NRG 9300 Data logger System with instrumentation installed at 30, 40 and 65 meters on an existing KINI radio tower. The long-term annual average wind speed at 65-meters above ground level is 18.2 mph (8.1 mps) and 18.7 mph (8.4 mps) at 80-meters agl. The wind resource is excellent and supports project financing.

17 WIND ENERGY↗