Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WIRING SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Implementation of Ada protocols on Mil-STD-1553 B data bus

Standardization activity of data communication in avionic systems started in 1968 for the purpose of total system integration and the elimination of heavy wire bundles carrying signals between various subassemblies. The growing complexity of avionic systems is straining the capabilities of MIL-STD-1553 B (first issued in 1973), but a much greater challenge to it is posed by Ada, the standard language adopted for real-time, computer embedded-systems. Hardware implementation of Ada communication protocols in a contention/token bus or token ring network is proposed. However, during the transition period when the current command/response multiplex data bus is still flourishing and the development environment for distributed multi-computer Ada systems is as yet lacking, a temporary accomodation of the standard language with the standard bus could be very useful and even highly desirable. By concentrating all status informtion and decisions at the bus controller, it was found to be possible to construct an elegant and efficient harware impelementation of the Ada protocols at the bus interface. This solution is discussed.

Ruhman, Smil↗

Practical aspects of instrumentation system installation, volume 13

A review of factors influencing installation of aircraft flight test instrumentation is presented. Requirements, including such factors as environment, reliability, maintainability, and system safety are discussed. The assessment of the mission profile is followed by an overview of electrical and mechanical installation factors with emphasis on shock/vibration isolation systems and standardization of the electric wiring installation, two factors often overlooked by instrumentation engineers. A discussion of installation hardware reviews the performance capabilities of wiring, connectors, fuses and circuit breakers, and a guide to proper selections is provided. The discussion of the installation is primarily concerned with the electrical wire routing, shield terminations and grounding. Also inclued are some examples of installation mistakes that could affect system accuracy. System verification procedures and special considerations such as sneak circuits, pyrotechnics, aircraft antenna patterns, and lightning strikes are discussed.

Borek, R. W.↗

Remote Diagnosis of the International Space Station Utilizing Telemetry Data

Modern systems such as fly-by-wire aircraft, nuclear power plants, manufacturing facilities, battlefields, etc., are all examples of highly connected network enabled systems. Many of these systems are also mission critical and need to be monitored round the clock. Such systems typically consist of embedded sensors in networked subsystems that can transmit data to central (or remote) monitoring stations. Moreover, many legacy are safety systems were originally not designed for real-time onboard diagnosis, but a critical and would benefit from such a solution. Embedding additional software or hardware in such systems is often considered too intrusive and introduces flight safety and validation concerns. Such systems can be equipped to transmit the sensor data to a remote-processing center for continuous health monitoring. At Qualtech Systems, we are developing a Remote Diagnosis Server (RDS) that can support multiple simultaneous diagnostic sessions from a variety of remote subsystems.

Deb, Somnath↗

The enhanced ASDEX Upgrade pellet centrifuge launcher

Pellets played an important role in the program of ASDEX Upgrade serving both for investigations on efficient particle fuelling and high density scenarios but also for pioneering work on Edge Localised Mode (ELM) pacing and mitigation. Initially designed for launching fuelling pellets from the magnetic low field side, the system was converted already some time ago to inject pellets from the magnetic high field side as much higher fuelling efficiency was found using this configuration. In operation for more than 20 years, the pellet launching system had to undergo a major revision and upgrading, in particular of its control system. Furthermore, the control system installed adjacent to the launcher had to be transferred to a more distant location enforcing a complete galvanic separation from torus potential and a fully remote control solution. Changing from a hybrid system consisting of PLC S5/S7 and some hard wired relay control to a state of the art PLC system allowed the introduction of several new operational options enabling more flexibility in the pellet experiments. This article describes the new system architecture of control hardware and software, the operating procedure, and the extended operational window. First successful applications for ELM pacing and triggering studies are presented as well as utilization for the development of high density scenarios.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Communication engine for hybrid interconnect technologies

Systems, apparatuses, and methods for dynamically selecting between wired and wireless interconnects for sending packets are disclosed. A system includes at least a hybrid communication engine and a plurality of interconnects for connecting to various end-points. The communication engine dynamically discovers and utilizes the best interconnect technology available in between given end-points. The communication engine dynamically chooses the physical interconnect that is best suited at any given time to send data from one source to one or multiple destinations. This communication can be either on-chip or across nodes. The communication engine makes a decision based on a set of predetermined parameters that can be re-adjusted by the application layer, such as latency of the transmission, message data size, physical distance from source to destination, the energy cost, and the current congestion on the alternative interconnects.

Blagodurov, Sergey↗

Nuclear Science Symposium, 23rd, Scintillation and Semiconductor Counter Symposium, 15th, and Nuclear Power Systems Symposium, 8th, New Orleans, La., October 20-22, 1976, Proceedings

The volume includes papers on semiconductor radiation detectors of various types, components of radiation detection and dosimetric systems, digital and microprocessor equipment in nuclear industry and science, and a wide variety of applications of nuclear radiation detectors. Semiconductor detectors of X-rays, gamma radiation, heavy ions, neutrons, and other nuclear particles, plastic scintillator arrays, drift chambers, spark wire chambers, and radiation dosimeter systems are reported on. Digital and analog conversion systems, digital data and control systems, microprocessors, and their uses in scientific research and nuclear power plants are discussed. Large-area imaging and biomedical nucleonic instrumentation, nuclear power plant safeguards, reactor instrumentation, nuclear power plant instrumentation, space instrumentation, and environmental instrumentation are dealt with. Individual items are announced in this issue.

Wagner, L. J.↗

Instrumentation systems for the Langley Research Center 8-foot high temperature tunnel

A description is presented of the 8-foot high-temperature tunnel, a Mach 7 blowdown-type facility in which methane is burned in air under pressure, with the resulting combustion products utilized as the test medium. The instrumentation environment and requirements are identified, and instrumentation design, including wiring, sensors, and data acquisition system are described. The design and installation of a fast oxygen monitoring system to maintain the partial pressure of oxygen at 21 percent in the tunnel test section is included. Also, the new data acquisition system hardware details and data-reduction capabilities are defined.

Walsh, James J., Jr.↗

CHERENKOV CONVERTER FOR LARGE DYNAMIC RANGE, HIGH SENSITIVITY DETECTORS FOR USE ON WIRE-SCANNERS

We are developing a wire-scanner with a dynamic range of 1e+6 or larger. In addition to the large dynamic range (LDR), high sensitivity is very desirable so that measurements can be made with a small amount of beam or small duty cycle beam. This high sensitivity requirement makes photo multiplier tubes (PMT) with low background levels, the preferred detector. Low dark current PMTs have maximum quantum efficiency in the visible wavelength range. We describe a converter where Cherenkov radiation (CR) is used to generate visible photons from electrons and positrons that are present due to wire-beam interaction. An optical system used to collect and couple the CR into an optical fiber is also described. The high directivity of the CR is used in such a way that, when CR in the radiating medium is generated by particles not directed from the wire-beam interaction point to the converter, the CR is not coupled into the optical fiber and therefore does not create background for the wire-scanner measurements. It is envisioned that the optical fiber will be used to deliver the visible photons to the PMT located outside of the accelerator tunnel to further reduce the background level. Sensitivities to the refractive index of the radiating medium, alignment and mechanical fabrication tolerances are also presented. *Work supported by US DOE office of Basic Energy Sciences under the early career program; DOE award number FWP#JLAB-BES11-05

Gubeli, Joseph↗

A governing parameter for the melting phenomenon at nanocontacts by Joule heating and its application to joining together two thin metallic wires

For cutting and joining extremely thin metallic wires, the issue of Joule heating in the wires is considered. The middle of a section of a thin Pt wire with a diameter of about 800 nm was melted locally by a direct current supply, and the wire was cut at a predetermined point by applying a force to shear the molten part of the wire. Furthermore, a constant current was applied to a system in which the free ends of two Pt wires were contacted, and the wires were joined together. A parameter, which governs the melting phenomenon at the point of contact of very thin wires, is proposed. It was verified that the conditions required for joining thin wires were able to be determined by the parameter that depends on the applied current, the length and cross sectional area of the wires, and a function of the geometrical quantities for calibrating the thermal conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitive gaseous hydrogen detection system

System utilizing new type hydrogen sensor has overall detection sensitivity and response speed higher than conventional hot-wire or hot-thermistor detectors. System measures concentrations of from 2 parts per million to 30 percent and is adaptable as leak detector and hazard alarm wherever hydrogen is used.

Macintyre, J. R.↗

AC/DC Power Systems with Applications for future Lunar/Mars base and Crew Exploration Vehicle

ABSTRACT The Power Systems branch at JSC faces a number of complex issues as it readies itself for the President's initiative on future space exploration beyond low earth orbit. Some of these preliminary issues - those dealing with electric power generation and distribution on board Mars-bound vehicle and that on Lunar and Martian surface may be summarized as follows: Type of prime mover - Because solar power may not be readily available on parts of the Lunar/Mars surface and also during the long duration flight to Mars, the primary source of power will most likely be nuclear power (Uranium fuel rods) with a secondary source of fuel cell (Hydrogen supply). The electric power generation source - With nuclear power being the main prime mover, the electric power generation source will most likely be an ac generator at a yet to be determined frequency. Thus, a critical issue is whether the generator should generate at constant or variable frequency. This will decide what type of generator to use - whether it is a synchronous machine, an asynchronous induction machine or a switched reluctance machine. The type of power distribution system - the distribution frequency, number of wires (3- wire, 4-wire or higher), and ac/dc hybridization. Building redundancy and fault tolerance in the generation and distribution sub-systems so that the system is safe; provides 100% availability to critical loads; continues to operate even with faulted sub-systems; and requires minimal maintenance. This report descril_es results of a summer faculty fellowship spent in the Power Systems Branch with the specific aim of investigating some of the lessons learned in electric power generation and usage from the terrestrial power systems industry, the aerospace industry as well as NASA's on-going missions so as to recommend novel surface and vehicle-based power systems architectures in support of future space exploration initiatives. A hybrid ac/dc architecture with source side and load side redundancies and including emergency generators on both ac and dc sides is proposed. The generation frequency is 400 Hz mostly because of the technology maturity at this frequency in the aerospace industry. Power will be distributed to several ac load distribution buses through solid state variable speed, constant frequency converters on the ac side. A segmented dc ring bus supplied from ac/dc converters and with the capability of connecting/disconnecting the segments will supply power to multiple de load distribution buses. The system will have the capability of reverse flow from dc to ac side in the case of an extreme emergency on the main ac generation side.

Chowdhury, Badrul H.↗

Situational Awareness from a Low-Cost Camera System

A method gathers scene information from a low-cost camera system. Existing surveillance systems using sufficient cameras for continuous coverage of a large field necessarily generate enormous amounts of raw data. Digitizing and channeling that data to a central computer and processing it in real time is difficult when using low-cost, commercially available components. A newly developed system is located on a combined power and data wire to form a string-of-lights camera system. Each camera is accessible through this network interface using standard TCP/IP networking protocols. The cameras more closely resemble cell-phone cameras than traditional security camera systems. Processing capabilities are built directly onto the camera backplane, which helps maintain a low cost. The low power requirements of each camera allow the creation of a single imaging system comprising over 100 cameras. Each camera has built-in processing capabilities to detect events and cooperatively share this information with neighboring cameras. The location of the event is reported to the host computer in Cartesian coordinates computed from data correlation across multiple cameras. In this way, events in the field of view can present low-bandwidth information to the host rather than high-bandwidth bitmap data constantly being generated by the cameras. This approach offers greater flexibility than conventional systems, without compromising performance through using many small, low-cost cameras with overlapping fields of view. This means significant increased viewing without ignoring surveillance areas, which can occur when pan, tilt, and zoom cameras look away. Additionally, due to the sharing of a single cable for power and data, the installation costs are lower. The technology is targeted toward 3D scene extraction and automatic target tracking for military and commercial applications. Security systems and environmental/ vehicular monitoring systems are also potential applications.

Freudinger, Lawrence C.↗

Advanced Diagnosis and Accelerated Testing of Balance of System Components for Utility Scale PV Installations: October 1, 2022-September 30, 2024

A study of the durability of PV Balance of System components was performed. Specifically, wire cable jackets and cable connectors were examined within the direct current (DC) PV Power Transmission Chain (PTC). Degraded and failed samples have been obtained from utility PV installations to provide feedback on the degradation modes and the related damage-enabling considerations in today's PV systems. An industry interface group (including system owners, system inspectors, component manufacturers, and test labs) was used to help identify and obtain field-failed samples, for feedback (including samples and experimental design), and to facilitate the subsequent dissemination of the results of this study. Samples were empirically studied using accelerated stress testing with steady-state conditions (cable jackets) in addition to combined-accelerated stress testing (cable jackets, connectors and uncapped connectors). Steady-state accelerated testing has been performed using at least one applied stressor (e.g. UV light) to aid understanding of jacket durability relative to its application. Component- and material-focused failure analysis was conducted to develop an understanding and advise the PV industry. In-depth characterization will be applied selectively to field- and artificially aged-samples, to gain scientific understanding of the structural, chemical, electrical, mechanical, and thermal properties enabling degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technology for Transportation Safety

Boston Insulated Wire & Cable developed a new polyimide foam material, commercially known as Solimide, which resists ignition. It chars and decomposes when exposed to open flames. Used in the space shuttle, the material does not "outgas" until it begins to char making it safer than current materials with respect to toxic fumes. The polyimide can be made in two forms: a resilient foam and a rigid foam. Used in commercial transport interiors for such soft components as seat cushions to door, wall, floor, and ceiling panels. Material's flame resistance could lengthen from two minutes to five minutes, the time needed for passenger evacuation in a ground emergency. Could help reduce airline fuel consumption, since the foam is 50% lighter than current materials. Low-smoke cable assemblies used in rapid transit systems consists of an advanced wire and cable jacketing material with superior flame resistance and smoke retardation characteristics. Being supplied to mass transit systems in the U.S. and abroad.

Source record↗

A&L Annual Report: GRM-MAPS

Exploding Bridge Wire (EBW) is an important design for initiating detonators relevant to several LLNL systems. In such designs, a metal bridge wire is in direct contact with a porous secondary high explosive (HE), typically pressed to around 50% of its crystalline density. Initiation is believed to occur through shock waves generated when the bridge wire is made to explode via the rapid passing of a strong current pulse. Permeametry is an important characterization tool for the porous powdered HE (PETN, HMX, etc.) component in such devices. Such powders are well known to coarsen with age, with an accompanying deterioration in performance, which includes increased function time and sensitivity. Among various material characteristics, one that has been shown to correlate the most with such performance parameters is the flow-permeable surface area (FSSA), measured using air-permeametry. Commercially available permeametry apparatuses, such as that from Fisher Scientific or a more modern version from Micromeritics suffer from a few drawbacks, most notably as related to monitoring age-related changes in FSSA. This is because it requires re-compaction of the aged powder into the permeametry tube, which in most cases leads to an unwanted increase in FSSA. To address this and a few other shortcomings, we have been developing a modern version of the permeameter, Gee-Reinstein-Maiti Modern Air-Permeametry System (GRM-MAPS). In this report, we summarize progress made in FY25 toward perfecting and calibrating the instrument, which we aim at deploying within surveillance in FY26.

36 MATERIALS SCIENCE↗

A wire calorimeter for the SPIDER beam: Experimental tests and feasibility study

To study and optimize negative ion production and acceleration, in view of the use of neutral beam injectors in the ITER project, the SPIDER test facility (particle energy 100keV; beam current 50A, distributed over 1280 beamlets) is under construction in Padova, with the aim of testing beam characteristics and to verify the source proper operation, by means of several diagnostic systems. An array of tungsten wires, directly exposed to the beam and consequently heated to high temperature, is used in similar experiments at IPP-Garching to study the beam optics, which is one of the most important issues, in a qualitative way. The present contribution gives a description of an experimental investigation of the behavior of tungsten wires under high heat loads in vacuum. Samples of tungsten wires are heated by electrical currents and the emitted light is measured by a camera in the 400-1100nm wavelength range, which is proposed as a calibration tool. Simultaneously, the voltage applied to the wire is measured to study the dependency of emissivity on temperature. The feasibility study of a wire calorimeter for SPIDER is finally proposed; to this purpose, the expected behaviour of tungsten with the two-dimensional beam profile in SPIDER is numerically addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low Frequency Electromagnetic Pulse and Explosions

This paper reviews and summarizes prior work related to low frequency (< 100 Hz) EMP (ElectroMagnetic Pulse) observed from explosions. It focuses on how EMP signals might, or might not, be useful in monitoring underground nuclear tests, based on the limits of detection, and physical understanding of these signals. In summary: (1) Both chemical and nuclear explosions produce an EMP. (2) The amplitude of the EMP from underground explosions is at least two orders of magnitude lower than from above ground explosions and higher frequency components of the signal are rapidly attenuated due to ground conductivity. (3) In general, in the near field, that is distances (r) of less than 10s of kilometers from the source, the amplitude of the EMP decays approximately as 1/r{sup 3}, which practically limits EMP applications to very close (<{approx}1km) distances. (4) One computational model suggests that the EMP from a decoupled nuclear explosion may be enhanced over the fully coupled case. This has not been validated with laboratory or field data. (5) The magnitude of the EMP from an underground nuclear explosion is about two orders of magnitude larger than that from a chemical explosion, and has a larger component of higher frequencies. In principle these differences might be used to discriminate a nuclear from a chemical explosion using sensors at very close (<{approx}1 km) distances. (6) Arming and firing systems (e.g. detonators, exploding bridge wires) can also produce an EMP from any type of explosion. (7) To develop the understanding needed to apply low frequency EMP to nuclear explosion monitoring, it is recommended to carry out a series of controlled underground chemical explosions with a variety of sizes, emplacements (e.g. fully coupled and decoupled), and arming and firing systems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗