Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VALLEYS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Hydrologic Impacts of a Strike-Slip Fault Zone: Insights from Joint 3D Body-Wave Tomography of Rock Valley

The Rock Valley fault zone (RVFZ), an intraplate strike-slip fault zone in the southern Nevada National Security Site (NNSS), hosted a series of very shallow (<3 km) earthquakes in 1993. The RVFZ may also have hydrological significance within the NNSS, potentially playing a role in regional groundwater flow, but there is a lack of local hydrological data. In the Spring of 2021, we collected active-source accelerated weight drop seismic data over part of the RVFZ to better characterize the shallow subsurface. Here, we manually picked ~17,000 P-wave travel times and over 14,000 S-wave travel times, which were inverted for P-wave velocity (V P ), S-wave velocity (V S ), and V P /V S ratio in a 3D joint tomographic inversion scheme. Seismic velocities are imaged as deep as ~700 m in areas and generally align with geologic and structural expectations. V P and V S are relatively reduced near mapped and inferred faults, with the most prominent lower V P and V S zone around the densest collection of faults. We image V P /V S ratios ranging from ~1.5 to ~2.4, the extremes of which occur at a depth of ~100 m and are juxtaposed across a fault. One possible interpretation of the imaged seismic velocities is enhanced fault damage near the densest collection of faults with relatively higher porosity and/or crack density at ~100 m depth, with patches of semiperched groundwater present in the sedimentary rock in higher V P /V S areas and drier rock in lower V P /V S areas. A relatively higher V P /V S area beneath the densest faults persists at depth, which suggests percolation of groundwater via the fault damage zone to the regionally connected lower carbonate aquifer. Potentially, the presence and movement of groundwater may have played a role in the 1993 earthquake aftershocks.

58 GEOSCIENCES↗

Determining Stress Orientation in Rock Valley, Nevada, Using Ambient Seismic Noise

The stress field and the mechanical properties of rocks are important to consider for nuclear explosion monitoring due to their effect on seismic wave radiation from earthquakes and explosions. At the Rock Valley Direct Comparison site, the regional orientation of the maximum horizontal compressive stress (SH max ) is well constrained, but it is unknown whether there are local heterogeneities. Here, I show that stress-induced anisotropy in nonlinear elasticity can be used to estimate the orientation of SH max . Rocks have compliant internal contacts, such as fractures and mineral grain boundaries, that respond to applied strains more strongly than individual mineral crystals. This strain response is asymmetric between compressive and dilatational strains and is affected by anisotropy in the ambient stress field. Traditional seismic velocity measurements are of strain-averaged velocity, which is less sensitive than nonlinear elasticity to the behavior of compliant internal contacts and therefore the stress field and fracture behavior. My results show that the orientation of SH max measured using ambient seismic noise aligns with regional estimates, with some heterogeneity that can also be explained by the limitations of the seismic array. I demonstrate the potential of a passive technique for monitoring the stress field in places that currently lack local measurements.

58 GEOSCIENCES↗

Humidity Bias and Effect on Simulated Aerosol Optical Properties during the Ganges Valley Experiment

The radiosonde humidity profiles available during the Ganges Valley Experiment were compared to those simulated from the regional Weather Research and Forecasting (WRF) model coupled with a chemistry module (WRF -Chern) and the global reanalysis datasets. Large biases were revealed. On a monthly mean basis at Nainital, located in northern India, the WRFChern model simulates a large moist bias in the free troposphere (up to +20%) as well as a large dry bias in the boundary layer (up to -30%). While the overall pattern of the biases is similar, the magnitude of the biases varies from time to time and from one location to another. At Thiruvananthapuram, the magnitude of the dry bias is smaller, and in contrast to Nainital, the higher-resolution regional WRF -Chern model generates larger moist biases in the upper troposphere than the global reanalysis data. Furthermore, the humidity biases in the upper troposphere, while significant, have little impact on the model estimation of column aerosol optical depth (AOD). The frequent occurrences of the dry boundary-layer bias simulated by the large-scale models tend to lead to the underestimation of AOD. It is thus important to quantify the humidity vertical profiles for aerosol simulations over South Asia.

aerosol extinction↗

California GAMA Special Study: An isotopic and dissolved gas investigation of nitrate source and transport to a public supply well in California's Central Valley

This study investigates nitrate contamination of a deep municipal drinking water production well in Ripon, CA to demonstrate the utility of natural groundwater tracers in constraining the sources and transport of nitrate to deep aquifers in the Central Valley. The goal of the study was to investigate the origin (source) of elevated nitrate and the potential for the deep aquifer to attenuate anthropogenic nitrate. The site is ideal for such an investigation. The production well is screened from 165-325 feet below ground surface and a number of nearby shallow and deep monitoring wells were available for sampling. Furthermore, potential sources of nitrate contamination to the well had been identified, including a fertilizer supply plant located approximately 1000 feet to the east and local almond groves. A variety of natural isotopic and dissolved gas tracers including {sup 3}H-{sup 3}He groundwater age and the isotopic composition of nitrate are applied to identify nitrate sources and to characterize nitrate transport. An advanced method for sampling production wells is employed to help identify contaminant contributions from specific screen intervals. Nitrate transport: Groundwater nitrate at this field site is not being actively denitrified. Groundwater parameters indicate oxic conditions, the dissolved gas data shows no evidence for excess nitrogen as the result of denitrification, and nitrate-N and -O isotope compositions do not display patterns typical of denitrification. Contaminant nitrate source: The ambient nitrate concentration in shallow groundwater at the Ripon site ({approx}12 mg/L as nitrate) is typical of shallow groundwaters affected by recharge from agricultural and urban areas. Nitrate concentrations in Ripon City Well 12 (50-58 mg/L as nitrate) are significantly higher than these ambient concentrations, indicating an additional source of anthropogenic nitrate is affecting groundwater in the capture zone of this municipal drinking water well. This study provides two new pieces of evidence that the Ripon Farm Services Plant is the source of elevated nitrate in Ripon City Well 12. (1) Chemical mass balance calculations using nitrate concentration, nitrate isotopic composition, and initial tritium activity all indicate that that the source water for elevated nitrate to Ripon City Well 12 is a very small component of the water produced by City Well 12 and thus must have extremely high nitrate concentration. The high source water nitrate concentration ({approx}1500 mg/L as nitrate) required by these mass balance calculations precludes common sources of nitrate such as irrigated agriculture, dairy wastewater, and septic discharge. Shallow groundwater under the Ripon Farm Services RFS plant does contain extremely high concentrations of nitrate (>1700 mg/L as nitrate). (2) Nitrogen and oxygen isotope compositions of nitrate indicate that the additional anthropogenic nitrate source to Ripon City Well 12 is significantly enriched in {delta}{sup 18}O-NO{sub 3}, an isotopic signature consistent with synthetic nitrate fertilizer, and not with human or animal wastewater discharge (i.e. dairy operations, septic system discharge, or municipal wastewater discharge), or with organic fertilizer. Monitoring wells on and near the RFS plant also have high {delta}{sup 18}O-NO{sub 3}, and the plant has handled and stored synthetic nitrate fertilizer that will have this isotopic signature. The results described here highlight the complexity of attributing nitrate found in long screened, high capacity wells to specific sources. In this case, the presence of a very high concentration source near the well site combined with sampling using multiple isotopic tracer techniques and specialized depth-specific techniques allowed fingerprinting of the source in the mixed-age samples drawn from the production well.

54 ENVIRONMENTAL SCIENCES↗

Phase 1 Characterization sampling and analysis plan West Valley demonstration project.

The Phase 1 Characterization Sampling and Analysis Plan (CSAP) provides details about environmental data collection that will be taking place to support Phase 1 decommissioning activities described in the Phase 1 Decommissioning Plan for the West Valley Demonstration Project, Revision 2 (Phase I DP; DOE 2009). The four primary purposes of CSAP data collection are: (1) pre-design data collection, (2) remedial support, (3) post-remediation status documentation, and (4) Phase 2 decision-making support. Data collection to support these four main objectives is organized into two distinct data collection efforts. The first is data collection that will take place prior to the initiation of significant Phase 1 decommissioning activities (e.g., the Waste Management Area [WMA] 1 and WMA 2 excavations). The second is data collection that will occur during and immediately after environmental remediation in support of remediation activities. Both data collection efforts have a set of well-defined objectives that encompass the data needs of the four main CSAP data collection purposes detailed in the CSAP. The main body of the CSAP describes the overall data collection strategies that will be used to satisfy data collection objectives. The details of pre-remediation data collection are organized by WMA. The CSAP contains an appendix for each WMA that describes the details of WMA-specific pre-remediation data collection activities. The CSAP is intended to expand upon the data collection requirements identified in the Phase 1 Decommissioning Plan. The CSAP is intended to tightly integrate with the Phase 1 Final Status Survey Plan (FSSP). Data collection described by the CSAP is consistent with the FSSP where appropriate and to the extent possible.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Phase 1 Final status survey plan for the West Valley demonstration project.

This plan provides the technical basis and associated protocols to support Phase 1 final status survey (FSS) data collection and interpretation as part of the West Valley Demonstration Project Phase 1 Decommissioning Plan process. This plan is consistent with the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM). The Phase 1 Decommissioning Plan provides the relevant derived concentration guideline levels (DCGLs) for the Phase 1 radionuclides of interest. This plan includes protocols that will be applied to the deep excavations planned for Waste Management Area (WMA) 1 and WMA 2, for surface soils outside the WMA 1 and WMA 2 excavations that do not have contamination impacts at depths greater than one meter, and for areas that are used for Phase 1 contaminated soil lay-down purposes. All excavated and lay-down areas will be classified as MARSSIM Class 1 areas. Surface soils that have not been excavated, are not expected to exceed DCGLs, and do not have contamination impacts at depths greater than one meter will be divided into either Class 1 or Class 2 areas depending on the expected potential for surface soil contamination in those areas. The plan uses gamma scans combined with biased soil samples to address DCGLemc concerns. The plan uses systematic soil sampling combined with area factors to address DCGLw and DCGLemc concerns. The Sign test will be used to statistically evaluate DCGLw compliance. If the results from the characterization sampling and analysis plan (CSAP) data collection indicate that background may be a significant issue for Sign test implementation, the Wilcoxon rank sum (WRS) test will be used instead to demonstrate DCGLw compliance. A reference area will be selected on the basis of CSAP data results if the WRS test becomes a necessity. The WMA 1 excavation footprint includes approximately 476 foundation pilings that will be trimmed and left in place. Piling-specific systematic and biased sampling will be conducted to address concerns that these pilings may have served as preferential flow pathways into the underlying Lavery till. Phase 1 FSS data collection results will be summarized, presented, and interpreted in one or more FSS reports.

54 ENVIRONMENTAL SCIENCES↗

Tennessee Valley and Eastern Kentucky Wind Working Group

In December 2009, the Southern Alliance for Clean Energy (SACE), through a partnership with the Appalachian Regional Commission, EKPC, Kentucky's Department for Energy Development and Independence, SACE, Tennessee's Department of Environment and Conservation, and TVA, and through a contract with the Department of Energy, established the Tennessee Valley and Eastern Kentucky Wind Working Group (TVEKWWG). TVEKWWG consists of a strong network of people and organizations. Working together, they provide information to various organizations and stakeholders regarding the responsible development of wind power in the state. Members include representatives from utility interests, state and federal agencies, economic development organizations, non-government organizations, local decision makers, educational institutions, and wind industry representatives. The working group is facilitated by the Southern Alliance for Clean Energy. TVEKWWG supports the Department of Energy by helping educate and inform key stakeholders about wind energy in the state of Tennessee.

17 WIND ENERGY↗

Interim Report on SNP analysis and forensic microarray probe design for South American hemorrhagic fever viruses, tick-borne encephalitis virus, henipaviruses, Old World Arenaviruses, filoviruses, Crimean-Congo hemorrhagic fever viruses, Rift Valley fever

The goal of this project is to develop forensic genotyping assays for select agent viruses, enhancing the current capabilities for the viral bioforensics and law enforcement community. We used a multipronged approach combining bioinformatics analysis, PCR-enriched samples, microarrays and TaqMan assays to develop high resolution and cost effective genotyping methods for strain level forensic discrimination of viruses. We have leveraged substantial experience and efficiency gained through year 1 on software development, SNP discovery, TaqMan signature design and phylogenetic signature mapping to scale up the development of forensics signatures in year 2. In this report, we have summarized the whole genome wide SNP analysis and microarray probe design for forensics characterization of South American hemorrhagic fever viruses, tick-borne encephalitis viruses and henipaviruses, Old World Arenaviruses, filoviruses, Crimean-Congo hemorrhagic fever virus, Rift Valley fever virus and Japanese encephalitis virus.

59 BASIC BIOLOGICAL SCIENCES↗

NNSS Soils Monitoring: Plutonium Valley (CAU366) FY2012

The U.S. Department of Energy (DOE) National Nuclear Security Administration (NNSA), Nevada Site Office (NSO), Environmental Restoration Soils Activity has authorized the Desert Research Institute (DRI) to conduct field assessments of potential sediment transport of contaminated soil from Corrective Action Unit (CAU) 366, Area 11 Plutonium Valley Dispersion Sites Contamination Area (CA) during precipitation runoff events.

54 ENVIRONMENTAL SCIENCES↗

Corrective Action Plan for Corrective Action Unit 366: Area 11 Plutonium Valley Dispersion Sites, Nevada National Security Site, Nevada

This Corrective Action Plan has been prepared for Corrective Action Unit (CAU) 366, Area 11 Plutonium Valley Dispersion Sites, in accordance with the Federal Facility Agreement and Consent Order (FFACO, 1996 as amended). CAU 366 consists of the following six Corrective Action Sites (CASs) located in Area 11 of the Nevada National Security Site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Closure Report for Corrective Action Unit 366: Area 11 Plutonium Valley Dispersion Sites, Nevada National Security Site, Nevada

This Closure Report (CR) presents information supporting closure of Corrective Action Unit (CAU) 366, Area 11 Plutonium Valley Dispersion Sites, and provides documentation supporting the completed corrective actions and confirmation that closure objectives for CAU 366 were met. This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; the U.S. Department of Energy (DOE), Environmental Management; the U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996 as amended).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

California GAMA Special Study: Interpretation of Isotopic Data in the Sonoma Valley, California

A shallow aquifer system near the city of El Verano in Sonoma Valley, California, supplies urban and rural water users. The source of recharge to this aquifer and its connection to Sonoma Creek are not well known, making its susceptibility and sustainability under different scenarios of land and water use difficult to assess. Under the State Water Resources Control Board Groundwater Ambient Monitoring and Assessment (GAMA) program, Lawrence Livermore National Laboratory carries out groundwater studies that focus on specific constituents of concern, or specific geographic areas where recharge and transport are not well determined. In this study, ten wells were sampled for tritium, helium isotopic composition, dissolved gas concentrations, concentrations of major anions and nitrate, and stable isotopes of water and of nitrate in order to examine sources of recharge, groundwater residence time, and water quality in the El Verano area.

54 ENVIRONMENTAL SCIENCES↗

Potential Visual Impacts of Utility-Scale Solar Energy Development within Solar Energy Zones on Selected Viewpoints in Death Valley and Joshua Tree National Parks, and El Camino Real De Tierra Adentro National Historic Trail

In connection with the Bureau of Land Management’s (BLM’s) Solar Programmatic Environmental Impact Statement (Solar PEIS), Argonne National Laboratory (Argonne) has conducted an extended visual impact analysis for selected key observation points (KOPs) within three National Park Service (NPS) units located within the 25-mi (40-km) viewshed of four solar energy zones (SEZs) identified in the Solar PEIS. The analysis includes only those NPS units that the Solar PEIS identified as potentially subject to moderate or strong visual contrasts associated with solar development within the SEZs. The NPS units included in the analysis are Death Valley and Joshua Tree National Parks and El Camino Real De Tierra Adentro National Historic Trail. The analysis showed that certain KOPs in each of these NPS units could potentially be subject to major visual contrast and impacts from solar development within the SEZs, but many of the KOPs would likely be subject to moderate, minor, or negligible contrasts and impacts, generally because they were relatively distant from the relevant SEZ, had views of the SEZ partially blocked by intervening terrain, and/or had very low vertical angles of view toward the SEZ. For all three NPS units, power tower facilities were found to be major contributors to potential visual contrasts, primarily because of the long-distance visibility of intensely bright reflection of light from the receivers on the central towers, but also because of the height and strong vertical line of the tower structures and the potential for night-sky impacts from FAA-mandated hazard navigation lighting.

14 SOLAR ENERGY↗

Final Review of the Campbell Creek Demonstrations Showcased by Tennessee Valley Authority

The Tennessee Valley Authority (TVA) Technology Innovation, Energy Efficiency, Power Delivery and Utilization Office funded and managed a showcase demonstration located in the suburbs of west Knox county, Tennessee. Work started March 2008 with the goal of documenting best practices for retrofitting existing homes and for building new high-efficiency homes. The Oak Ridge National Laboratory and the Electric Power Research Institute (EPRI) provided technical support. An analytical base was developed for helping homeowners, homebuyers, builders, practitioners and the TVA make informed economic decisions for the materials and incentives necessary to build a new high-efficiency home or retrofit an existing home. New approaches to more efficiently control active energy subsystems and information for selecting or upgrading to Energy Star appliances, changing all lights to 100% CFL s and upgrading windows to low-E gas filled glazing yields a 40% energy savings with neutral cash flow for the homeowner. Passive designs were reviewed and recommendations made for envelope construction that is durable and energy efficient. The Campbell Creek project complements the DOE Building Technologies Program strategic goal. Results of the project created technologies and design approaches that will yield affordable energy efficient homes. The 2010 DOE retrofit goals are to find retrofit packages that attain 30% whole house energy savings as documented by pre and post Home Energy rating scores (HERS). Campbell Creek met these goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the Costs and Benefits of Resilience Investments: Tennessee Valley Authority Case Study

This report describes a general approach for assessing climate change vulnerabilities of an electricity system and evaluating the costs and benefits of certain investments that would increase system resilience. It uses Tennessee Valley Authority (TVA) as a case study, concentrating on the Cumberland River basin area on the northern side of the TVA region. The study focuses in particular on evaluating risks associated with extreme heat wave and drought conditions that could be expected to affect the region by mid-century. Extreme climate event scenarios were developed using a combination of dynamically downscaled output from the Community Earth System Model and historical heat wave and drought conditions in 1993 and 2007, respectively.

54 ENVIRONMENTAL SCIENCES↗

San Luis Valley - Taos Plateau Landscape-Level Cultural Heritage Values and Risk Assessment

The San Luis Valley – Taos Plateau Landscape-Level Cultural Heritage Values and Risk Assessment (hereafter referred to as cultural assessment) is a BLM pilot project designed to see whether the Rapid Ecoregional Assessment (REA) framework (already established and implemented throughout many ecoregions in the West) can be applied to the cultural environment.

99 GENERAL AND MISCELLANEOUS↗

Christmas Valley Renewable Energy Assessment

In partnership with the Oregon Military Department, the Department of Energy used the award to assess and evaluate renewable resources in a 2,622-acre location in Lake County, central Oregon, leading to future development of up to 200 MW of solar electricity. In partnership with the Oregon Military Department, the Department of Energy used the award to assess and evaluate renewable resources in a 2,622-acre location in Lake County, central Oregon, leading to future development of up to 200 MW of solar electricity. The Oregon Military Department (Military) acquired a large parcel of land located in south central Oregon. The land was previously owned by the US Air Force and developed for an Over-the-Horizon Backscatter Radar Transmitter Facility, located about 10 miles east of the town of Christmas Valley. The Military is investigating a number of uses for the site, including Research and Development (R&D) laboratory, emergency response, military operations, developing renewable energy and related educational programs. One of the key potential uses would be for a large scale solar photovoltaic power plant. This is an attractive use because the site has excellent solar exposure; an existing strong electrical interconnection to the power grid; and a secure location at a moderate cost per acre. The project objectives include: 1. Site evaluation 2. Research and Development (R&D) facility analysis 3. Utility interconnection studies and agreements 4. Additional on-site renewable energy resources analysis 5. Community education, outreach and mitigation 6. Renewable energy and emergency readiness training program for veterans

14 SOLAR ENERGY↗

Unreviewed Disposal Question Evaluation: Disposal of the West Valley Demonstration Project Contaminated Concrete and General Debris at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nye County, Nevada

This Unreviewed Disposal Question Evaluation (UDQE) assesses whether the West Valley Demonstration Project (WVDP) Contaminated Concrete and General Debris (WVDP000000013, Revision 12 [WVDP 2017]) is suitable for shallow land burial (SLB) at the Area 5 Radioactive Waste Management Site (RWMS) on the Nevada National Security Site (NNSS). Disposal of the WVDP Contaminated Concrete and General Debris waste stream meets all U.S. Department of Energy (DOE) Manual DOE M 435.1-1, Radioactive Waste Management Manual, Chapter IV, Section P performance objectives (DOE 1999). The WVDP Contaminated Concrete and General Debris is recommended for acceptance with the condition that the total radium-226 (226Ra) activity not exceed 8.1E9 becquerels (Bq).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗