Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ULTRASONIC WAVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Ultrasonic Inspection During Autoclave Cure of Reflowable-Interface Composite Joints

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making the interface susceptible to minute quantities of contamination, which can cause weak bonds. Regulatory organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded primary-structures due to uncertainty in bond performance. To address this issue, the NASA Convergent Aeronautics Solutions (CAS): Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy-matrix resins to enable reflow and diffusion of the resin at the joint interface during a secondary bonding and cure process that can eliminate the material discontinuity at the interface. Implementing in-situ process monitoring enables assessing the bond quality during processing rather than waiting for post-fabrication mechanical testing to be completed. In this paper, an in-situ ultrasonic inspection system is used to monitor the joining of three composite laminates assembled using the AERoBOND technique. For each panel, the amplitude of the wave reflection at the joint was measured throughout the cure cycle. The results indicate the timing and extent of reflow and cure of the epoxy resin at the joint. Factors indicating end of cure were ascertained and a metric was developed to qualitatively predict acceptable mode-II fracture toughness based on the ultrasonic amplitude at the joint line during cure. In addition, since the inspection system scans an area of the joint, high-resolution localized results can be obtained across the joint.

Tyler B Hudson↗

Ultrasonic Monitor To Determine Crack-Opening Load

New ultrasonic monitor to determine crack-opening load in compact tension specimen uses transducers to pass acoustic wave across crack region. Definite improvement in signal-to-noise ratio. Process possesses substantial immunity from noise caused by operation of load frame and associated parts. In addition to applications for aerospace community, this monitor and concept clearly have general utility in testing of materials and potentially in nondestructive evaluation of solid parts.

Yost, William T.↗

Ultrasonic and micromechanical study of damage and elastic properties of SiC/RBSN ceramic composites

Ultrasonic techniques are employed to develop methods for nondestructive evaluation of elastic properties and damage in SiC/RBSN composites. To incorporate imperfect boundary conditions between fibers and matrix into a micromechanical model, a model of fibers having effective anisotropic properties is introduced. By inverting Hashin's (1979) microstructural model for a composite material with microscopic constituents the effective fiber properties were found from ultrasonic measurements. Ultrasonic measurements indicate that damage due to thermal shock is located near the surface, so the surface wave is most appropriate for estimation of the ultimate strength reduction and critical temperature of thermal shock. It is concluded that bonding between laminates of SiC/RBSN composites is severely weakened by thermal oxidation. Generally, nondestructive evaluation of thermal oxidation effects and thermal shock shows good correlation with measurements previously performed by destructive methods.

Chu, Y. C.↗

Delaminations Investigated With Ultrasonic Spectroscopy

A previous study suggested that the ultrasonic spectroscopy technique identified possible disbonds or delaminations in polymer matrix composite (PMC) rings sectioned from flywheel rotors (ref. 1). These results went unsubstantiated by other nondestructive evaluation (NDE) methods. To explain the results, PMC rings were further investigated with ultrasonic spectroscopy (ref. 2). The ultrasonic spectroscopy system utilizes a continuous-swept sine waveform as the input. After the swept sine wave traverses the material, the captured waveform is subjected to two fast Fourier transforms. The second fast Fourier transform along with equalization of the frequency spectrum, allows for evaluation of the fundamental resonant frequency. The full-thickness resonance, the resonance corresponding to the location of the intentional disbond, and the frequency spectrum were examined in an effort to characterize the sensitivity of the NDE method to various delamination conditions.

Cosgriff, Laura M.↗

Classification of Ultrasonic Weld Quality using Acoustic Signatures Acquired During Manufacture

Ultrasonic welding is a process is based on generating a solid-state bond between two metals by applying moderate pressure and high intensity sound waves (20-70 kHz frequencies) at their interface. During the solid-state process numerous material, surface, instrument, and environmental factors contribute to bond formation, strength, and durability. The inherent difficulty of measuring and controlling each of these factors has, to date, made predicting bond quality elusive. In this work, a Sonics model MWB20 ultrasonic spot welder with integral base, was used to produce a variety of welds of different metal foils under varying weld conditions. Acoustic measurements were recorded throughout the measurement process. Subsequent analysis of the signals using metrics that approximate the energy dispersed during the weld proved to successfully predict weld quality. Two metrics based on normalized energy differential and Renyi entropy were developed into Python and C++ scripts for direct analysis of weld acoustic data.

36 MATERIALS SCIENCE↗

PSIDD3: Post-Scan Ultrasonic Data Display System for the Windows-Based PC Including Fuzzy Logic Analysis

Post-Scan Interactive Data Display (PSIDD) III is a user-oriented Windows-based system that facilitates the display and comparison of ultrasonic contact data. The system is optimized to compare ultrasonic measurements made at different locations within a material or at different stages of material degradation. PSIDD III provides complete analysis of the primary wave forms in the time and frequency domains along with the calculation of several frequency dependent properties including Phase Velocity and Attenuation Coefficient and several frequency independent properties, like the Cross Correlation Velocity. The system allows image generation on all of the frequency dependent properties at any available frequency (limited by the bandwidth used in the scans) and on any of the frequency independent properties. From ultrasonic contact scans, areas of interest on an image can be studied with regard to underlying raw waveforms and derived ultrasonic properties by simply selecting the point on the image. The system offers various modes of in-depth comparison between scan points. Up to five scan points can be selected for comparative analysis at once. The system was developed with Borland Delphi software (Visual Pascal) and is based on a SQL database. It is ideal for classification of material properties, or location of microstructure variations in materials.

Lovelace, Jeffrey J.↗

Lamb Wave Stiffness Characterization of Composites Undergoing Thermal-Mechanical Aging

The introduction of new, advanced composite materials into aviation systems requires a thorough understanding of the long term effects of combined thermal and mechanical loading upon those materials. Analytical methods investigating the effects of intense thermal heating combined with mechanical loading have been investigated. The damage mechanisms and fatigue lives were dependent on test parameters as well as stress levels. Castelli, et al. identified matrix dominated failure modes for out-of-phase cycling and fiber dominated damage modes for in-phase cycling. In recent years, ultrasonic methods have been developed that can measure the mechanical stiffness of composites. To help evaluate the effect of aging, a suitably designed Lamb wave measurement system is being used to obtain bending and out-of-plane stiffness coefficients of composite laminates undergoing thermal-mechanical loading. The system works by exciting an antisymmetric Lamb wave and calculating the velocity at each frequency from the known transducer separation and the measured time-of-flight. The same peak in the waveforms received at various distances is used to measure the time difference between the signals. The velocity measurements are accurate and repeatable to within 1% resulting in reconstructed stiffness values repeatable to within 4%. Given the material density and plate thickness, the bending and out-of-plane shear stiffnesses are calculated from a reconstruction of the dispersion curve. A mechanical scanner is used to move the sensors over the surface to map the time-of-flight, velocity, or stiffnesses of the entire specimen. Access to only one side of the material is required and no immersion or couplants are required because the sensors are dry coupled to the surface of the plate. In this study, the elastic stiffnesses D(sub 11), D(sub 22), A(sub 44), and A(sub 55) as well as time-of-flight measurements for composite samples that have undergone combined thermal and mechanical aging for a duration of 10,000 hours are reported.

Seale, Michael D.↗

Material Characterization of Grade 91 Steel Welds using, Micro-resolution Ultrasonic Imaging System

Grade 91 (9Cr-1Mo-V) steel is a common structural material for fossil-fuel fired and nuclear power plants because of its creep strength and oxidation resistance at high temperatures. In this research, we studied the feasibility of correlating the high-resolution images obtained from the immersion ultrasonic imaging technique to microstructure regions in Grade 91 steel plate weldments. The high-resolution ultrasonic images presented in this paper were generated using a 20-MHz focused transducer as the transmitter, and a laser vibrometer as the receiver in the through transmission configuration to produce longitudinal and shear waves. This nondestructive evaluation (NDE) method was used to identify the Fusion Zone (FZ), Heat-Affected Zone (HAZ), and Base Metal (BM) regions of Grade 91 cold metal transfer (CMT) and flux core arc welds (FCAW). The ultrasonic imaging results were analyzed using beam propagation amplitudes and homogeneity, which in turn were used to relate the different microstructure regions of the FCAW and CMT welded samples. With this study, we were able to identify highly susceptible microstructures in the weld that could potentially promote creep type failures.

20 FOSSIL-FUELED POWER PLANTS↗

Ultrasonics used to measure residual stress

Ultrasonic method is used to measure residual stress in metal structures. By using this method, various forms of wave propagation in metals are possible, and more thorough analysis of complex geometric structures may be had.

Source record↗

Tracking Polymer Cure Via Embedded Optical Fibers

Fourier-transform infrared spectroscopy applied in interior of specimen of material by bringing infrared light through specimen in optical fiber. Light interacts with material via evanescent-wave effect. Spectra obtained in this way at various times during curing process also combined with data from ultrasonic, thermographic, and dielectric-impedance monitoring, and other measurement techniques to obtain more complete characterization of progress of curing process.

Dean, David L.↗

Ten-fold augmentation of endothelial uptake of vascular endothelial growth factor with ultrasound after systemic administration

OBJECTIVES: In this study, the feasibility of delivering and enhancing the uptake of vascular endothelial growth factor (VEGF) into the intact endothelium by using ultrasound (US) facilitation was determined. BACKGROUND: A limitation of tissue-targeted drug delivery is the need for direct arterial cannulation. We postulate a mechanism by which agents injected intravenously may be targeted to a tissue using US and ultrasonic contrast agents. METHODS: We used a rat model to test the ability of US and an ultrasonic contrast agent perflurocarbon exposed sonicated dextrose albumin (PESDA) to increase uptake of VEGF in the myocardium. Continuous wave Doppler US (0.6 W/cm2 at 1 MHz for 15 min) was applied to the chest wall overlying the myocardium during intravenous injection with either VEGF (100 microg/kg) alone or a combination of VEGF and PESDA (0.1%). Control rats had VEGF infused without US or PESDA. The VEGF uptake was measured quantitatively in the heart, lung, liver and kidneys by enzyme-linked immunosorbent assay (ng/g of tissue) and morphologically by fluorescence microscopy. RESULTS: There was an eight-fold increase in VEGF uptake in the heart by US alone (16.86 +/- 1.56 vs. 2.11 +/- 0.953 ng/g of tissue, p < 0.0001) and a 13-fold increase with US + PESDA (26.78 +/- 2.88 vs. 2.11 +/- 0.953 ng/g of tissue, p < 0.0001) compared with control rats. Fluorescence microscopy revealed deposition of VEGF in the endothelium of small intramyocardial arterioles. CONCLUSIONS: These results show a marked increase in endothelial VEGF uptake with US and US + PESDA. Thus, US may be used to augment endothelial VEGF uptake 10-fold to 13-fold.

Non-NASA Center↗

Defects Detection and Characterization Using Leaky Lamb Wave (LLW) Dispersion Data

Composite materials are being used at a significant level of usage for flaw critical structures and they are taking a growing percentage of the makeup of aircraft and spacecraft. Composite structues are now reaching service duration, for which the issue of aging is requiring adquate attention.

Leaky Lamb Wave LLW Polar Backscattering Composite↗

Acousto-ultrasonic evaluation of ceramic matrix composite materials

Acousto-ultrasonic nondestructive evaluation of ceramic composite specimens with a lithium-alumino-silicate glass matrix reinforced with unidirectional silicon carbide (NICALON) fibers was conducted to evaluate their reserve of strength. Ceramic composite specimens with different amount of damage were prepared by four-point cyclic fatigue loading of the specimens at 500 C for a different number of cycles. The reserve of strength of the specimens was measured as the maximum bending stress recorded during four-pointed bending test with the load monotonically increased until failure occurs. It was observed that the reserve of strength did not correlate with the number of fatigue cycles. However, it was also observed that higher values of the stress wave factor measurements correspond to higher values of the reserve of strength test data. Therefore, these results show that the acousto-ultrasonic approach has the potential of being used to monitor damage and to estimate the reserve of strength of ceramic composites.

Dosreis, Henrique L. M.↗

Acousto-ultrasonic nondestructive evaluation of materials using laser beam generation and detection

The acousto-ultrasonic method has proven to be a most interesting technique for nondestructive evaluation of the mechanical properties of a variety of materials. Use of the technique or a modification thereof, has led to correlation of the associated stress wave factor with mechanical properties of both metals and composite materials. The method is applied to the nondestructive evaluation of selected fiber reinforced structural composites. For the first time, conventional piezoelectric transducers were replaced with laser beam ultrasonic generators and detectors. This modification permitted true non-contact acousto-ultrasonic measurements to be made, which yielded new information about the basic mechanisms involved as well as proved the feasibility of making such non-contact measurements on terrestrial and space structures and heat engine components. A state-of-the-art laser based acousto-ultrasonic system, incorporating a compact pulsed laser and a fiber-optic heterodyne interferometer, was delivered to the NASA Lewis Research Center.

Huber, Robert D.↗

Field-angle dependence of sound velocity in the Weyl semimetal TaAs

The elastic modulus c 44 of a single crystal of the Weyl semimetal TaAs was investigated by measuring relative changes in the sound velocity under application of a magnetic field up to 10 T. Using an ultrasonic pulsed-echo technique, we studied the shear response of the crystal when the angle between the sound wave propagation and the magnetic field is changed. We observe a broken tetragonal symmetry at fields above 6 T, an anisotropy that is likely related to a longitudinal negative magnetoresistance and therefore might provide evidence of the chiral anomaly, one of the main topological signatures of this class of materials. Furthermore, we also observe quantum oscillations in the sound velocity whose frequencies vary with magnetic field orientation. A fan diagram of Landau level indices reveals topological and trivial Berry phases, depending on the field orientation, indicating a sensitivity to different Fermi surface pockets that do or do not enclose Weyl nodes, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural integrity test and assessment.

The feasibility of using an ultrasonic system on board the Space Shuttle Orbiter to facilitate structural evaluation and assessment was studied. Two factors are considered that could limit the capability of an ultrasonic system: (1) the effect of structure configuration and (2) the noise generated during vehicle launch. Results of the study indicate that although the structural configuration has direct bearing on sound propagation, strategic location of transducers will still permit flaw detection. The ultrasonic response data show that a severe acoustic environment does not interfere significantly with either propagation and reflection of surface waves or detection of crack-like flaws in the structure.

Suggs, F.↗

Overview of Nondestructive Evaluation Capabilities at NASA MSFC

Nondestructive evaluation (NDE) methods examine material integrity without impairing its usefulness. The NDE team at NASA Marshall Space Flight Center (MSFC) in Huntsville, Alabama is responsible for applying existing methods to new hardware designs and material systems, probability of detection studies to quantify detection capabilities, overseeing NDE requirements for flight hardware, inspecting development articles and flight hardware, engineering support for failure investigations, and investigating emerging NDE methods. NASA MSFC has been on the cutting edge of developing new NDE techniques, first for the space shuttle, then for composite structures, and most recently for additive manufacturing (AM). Standard in-house inspection capabilities include eddy current, magnetic particle, liquid penetrant, ultrasonic, and radiographic testing (including computed tomography). Other advanced inspection capabilities include infrared flash thermography, shearography, acoustic emission, and microwave/millimeter wave testing. Some recent research studies include AM probability of detection testing, investigating in-situ process monitoring methods for AM, and correlating the NDE response of true fatigue cracks with artificial notches.

nondestructive evaluation↗

Software-Defined Ultrasonic Communication System Based on Time-reversal Signal Processing

Ultrasonic communication through solid channels suffers from channel dispersion, attenuation, and multipath effect. For example, in elbow shape pipes or complex structures, the elastic waves are reflected and reverberated in multipath resulting in a major dispersion of the signals. In solid channels such as flat bar, multipath propagation is the main reason for bit-wavelet spreading and intersymbol interference (ISI). The conventional modulation method like OOK (on-off-keying) or PSK (phase-shift-keying) fails to provide a useful Signal-to-Noise Ratio (SNR). Time-reversal (TR) signal processing method is a promising technique that can compress the spreading of the bit-wavelet and strengthen the peak signal energy on the receiver. In this study, Finite Element Analysis (FEA) using ABAQUS software tools is used to characterize the bit-wavelet spreading effect caused by dispersive communication channels. Also, this study presents the impact of TR ultrasonic communication as a function of excitation pulse width, channel length, and carrier frequency through a flat-bar channel. A Software-Defined System-on-Chip (SD-SoC) platform is examined as a viable solution for the low-complexity and energy-efficient ultrasonic communication system. The proposed TR based SD-SoC ultrasonic communication system can make full use of signal dispersion for peak performance by minimizing the ISI within a dispersive and reverberant metal channel.

FEM simulation↗