Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Probabilistic Analysis of Long-Term Degradation of Microwave Cavity Flow Sensor

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. We have performed a proof-of-concept experiment of flow sensing with the transducer in liquid sodium at 340°C in impinging liquid jet geometry. The transducer remained in liquid sodium for 70 days. After removal, no structural damage was observed, and the expected transducer response was verified in a water test. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance. Since a yellowish residue was observed on the transducer surface after 70 days of immersion in liquid sodium, we have investigated possible evidence of corrosion. Chromium depletion is a typical indicator of the corrosion process in stainless steel. Scraping off a residue from the transducer and performing scanning electron microscopy (SEM) with energy dispersive analysis (EDS) did not find any chromium in the residue. Approximately 60% of the residue consisted of copper, which can be attributed to contamination of sodium due to powder residue from machining of copper and brass components of the transducer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis and Comparison of Surface Roughness Effects on Pressure Data from SLS Wind Tunnel Test

Unsteady flows are becoming a more characterized field of study as advancements in technology is allowing for more high-speed, time-resolved data acquisition. It is important to understand these flows as the shock-wave boundary-layer interactions and separation they are involved with can generate extreme loads caused by high pressure and temperature on the body of a flight vehicle. It is vital to characterize these loads, as they can impede upon the structural integrity of a high-speed system. A common instrument utilized today to characterize pressure distributions caused by unsteady flows are unsteady pressure transducers. Set flush with the surface of a flight vehicle or wind tunnel model, these transducers can provide a pressure distribution, capturing the frequency of unsteady loads that could impinge upon the test article. A couple negative aspects of this instrumentation is that they are expensive, have long lead times, and a pressure distribution can only be determined in one discrete location where the transducer is installed. An optical diagnostic known as unsteady pressure-sensitive paint (uPSP) can help to satisfy these deficiencies. This is a spray paint that can be applied to a surface of a model to provide a global pressure distribution across the whole painted region.2 A complete picture of the fluid dynamic pressures occurring on the surface of a test article can be analyzed, especially in locations where it may have been impossible to install a transducer. Pressure-sensitive paint is also less expensive than traditional pressure transducers, which are, on average, about $2,000 each including the cost of installation.3 Unsteady PSP will not replace unsteady pressure transducers, but the transducers can be used to validate the PSP response to the flow and measure frequencies higher than the frequency response of the paint. One issue that can arise using these tools simultaneously, is that the surface roughness of the uPSP can affect the pressure readings of the transducers. Applying the uPSP to the surface of the model is going to affect the flow in some way as the topography of the model is now different than if it was not painted. One study with steady PSP conducted by Amer, Obara, and Liu at NASA Langley concluded that the PSP surface roughness was minimally intrusive at different test conditions with various lift, drag, etc., however, it was noted that data from some pressure transducers had decreased, likely due to the uneven application of the PSP in the localized region of the transducers.9 Sugioka et. al. tested various formulations of uPSP to study surface roughness effects on a Common Research Model (CRM) in transonic flow. The influence of uPSP on the surface of the model, depending on how it was formulated, was noted to have the possibility of relocating the shock wave present in the flow. This study was conducted to examine and compare transducer data acquired in December 2017 of a 4% scale model of the Space Launch System (SLS) performed at NASA Ames Research Center (ARC) Unitary Plan Wind Tunnel (UPWT). One goal of the test was to demonstrate to the customer the potential of the uPSP system developed at NASA ARC. The effect of uPSP on transducer signals also became an interest in this experiment and is the reason for this data analysis. The results of this study were discussed with the SLS team to help them make decisions regarding the next test on an SLS model with the PSP and Unitary Plan Wind Tunnel teams.

pressure-sensitive paint↗

Pressure-Application Device for Testing Pressure Sensors

A portable pressure-application device has been designed and built for use in testing and calibrating piezoelectric pressure transducers in the field. The device generates pressure pulses of known amplitude. A pressure pulse (in contradistinction to a steady pressure) is needed because in the presence of a steady pressure, the electrical output of a piezoelectric pressure transducer decays rapidly with time. The device includes a stainless- steel compressed-air-storage cylinder of 500 cu cm volume. A manual hand pump with check valves and a pressure gauge are located at one end of the cylinder. A three-way solenoid valve that controls the release of pressurized air is located at the other end of the cylinder. Power for the device is provided by a 3.7-V cordless-telephone battery. The valve is controlled by means of a pushbutton switch, which activates a 5 V to +/-15 V DC-to-DC converter that powers the solenoid. The outlet of the solenoid valve is connected to the pressure transducer to be tested. Before the solenoid is energized, the transducer to be tested is at atmospheric pressure. When the solenoid is actuated by the push button, pressurized air from inside the cylinder is applied to the transducer. Once the pushbutton is released, the cylinder pressure is removed from the transducer and the pressurized air applied to the transducer is vented, bringing the transducer back to atmospheric pressure. Before this device was used for actual calibration, its accuracy was checked with a NIST (National Institute of Standards and Technology) traceable calibrator and commercially calibrated pressure transducers. This work was done by Wanda Solano of Stennis Space Center and Greg Richardson of Lockheed Martin Corp.

Source record↗

Cantilever with a collocated piezoelectric actuator-sensor pair

Illustrative embodiments provide an apparatus comprising a substrate comprising a cantilever, a bottom electrode on the substrate, a bottom piezoelectric transducer on the bottom electrode such that the bottom electrode is between the substrate and the bottom piezoelectric transducer, a middle electrode on the bottom piezoelectric transducer such that the bottom piezoelectric transducer is between the bottom electrode and the middle electrode, a top piezoelectric transducer on the middle electrode such that the middle electrode is between the bottom piezoelectric transducer and the top piezoelectric transducer, and a top electrode on the top piezoelectric transducer, such that the top piezoelectric transducer is between the middle electrode and the top electrode. Illustrative embodiments also provide a method of making the apparatus and a method of using the apparatus for atomic force microscopy.

Moheimani, Seyed Omid Reza↗

High performance miniature hygrometer and method thereof

An uncoated interdigitated transducer is cooled from a temperature above the dew point to a temperature below the dew point, while a parameter of a signal of the transducer is measured. The reduction in temperature causes a monotonic change in transducer signal because that signal is sensitive primarily to the water loading of the transducer surface as water forms on that surface due to the reduction in temperature. As the dew point is approached with temperature reduction, the slope of the curve of transducer signal with respect to temperature, remains relatively constant. However, as the dew point is reached the slope of that curve increases and because of changes in the structure of the water layer on the surface of the transducer, at the dew point the transducer responds with a clear shift in the rate at which the transducer signal changes. The temperature at which the second derivative of signal vs. temperature peaks can be readily used to identify with extreme accuracy, the precise dew point. The measurement technique employed by the present invention is relatively immune to surface contamination which remains significantly unchanged during the brief measurement period.

VanZandt, Thomas R.↗

Micro-Horn Arrays for Ultrasonic Impedance Matching

Thin-layered structures containing arrays of micromachined horns, denoted solid micro-horn arrays (SMIHAs), have been conceived as improved means of matching acoustic impedances between ultrasonic transducers and the media with which the transducers are required to exchange acoustic energy. Typically, ultrasonic transducers (e.g., those used in medical imaging) are piezoelectric or similar devices, which produce small displacements at large stresses. However, larger displacements at smaller stresses are required in the target media (e.g., human tissues) with which acoustic energy is to be exchanged. Heretofore, efficiencies in transmission of acoustic energy between ultrasonic transducers and target media have been severely limited because substantial mismatches of acoustic impedances have remained, even when coupling material layers have been interposed between the transducers and the target media. In contrast, SMIHAs can, in principle, be designed to effect more nearly complete acoustic impedance matching, leading to power transmission efficiencies of 90 percent or even greater. The SMIHA concept is based on extension, into the higher-frequency/ lower-wavelength ultrasonic range, of the use of horns to match acoustic impedances in the audible and lower-frequency ultrasonic ranges. In matching acoustic impedance in transmission from a higher-impedance acoustic source (e.g., a piezoelectric transducer) and a lowerimpedance target medium (e.g., air or human tissue), a horn acts as a mechanical amplifier. The shape and size of the horn can be optimized for matching acoustic impedance in a specified frequency range. A typical SMIHA would consist of a base plate, a face plate, and an array of horns that would constitute pillars that connect the two plates (see figure). In use, the base plate would be connected to an ultrasonic transducer and the face plate would be placed in contact with the target medium. As at lower frequencies, the sizes and shapes of the pillars could be tailored for impedance matching in a specified ultrasonic frequency range. In a design that would be simplest to implement by micromachining, the horns would have constant cross-sectional areas as shown in the upper part of the figure. In this case, the dimensions of the horns could be chosen on the basis of a Mason equivalent-circuit model (a simplified model, well-known in the piezoelectric-transducer art, in which the electrical and mechanical dynamics, including electromechanical couplings, are expressed as electrical circuit elements that can include inductors, capacitors, and lumped-parameter complex impedances.) In a more complex, more nearly optimum design, the cross-sectional area of each horn would be either stepped or made to vary as a continuous function of through-the thickness position, as shown in the lower part of the figure.

Rao, Shanti↗

Frequency coded sensors incorporating tapers

A surface acoustic wave device includes a piezoelectric substrate on which is formed a transducer that generates acoustic waves on the surface of the substrate from electrical waves received by the transducer. The waves are carried along an acoustic track to either a second transducer or a reflector. The transducers or transducer and reflector are formed of subsections that are constructed to operate at mutually different frequencies. The subsections of at least one of the transducers or transducer and reflector are out of alignment with respect to one another relative to the transverse of the propagation direction. The out of aligned subsections provide not only a frequency component but also a time to the signal output signal. Frequency response characteristics are improved. An alternative embodiment provides that the transducers and/or reflectors are continuously tapered instead of having discrete frequency subsections.

Hines, Jacqueline H.↗

Effect of Surface Pressure Integration Methodology on Launch Vehicle Buffet Forcing Functions

The 2014 test of the Space Launch System (SLS) Rigid Buffet Model conducted at the NASA Langley Transonic Dynamics Tunnel employed an extremely high number of unsteady pressure transducers. The high channel count provided an opportunity to examine the effect of transducer placement on the resulting buffet forcing functions (BFFs). Rings of transducers on the forward half of the model were employed to simulate a single-body vehicle. The impact of transducer density, circumferential distribution, and loss of a single transducer on the resulting BFFs were examined. Rings of transducers on the aft half of the SLS model were employed to examine the effect of transducer density and circumferential distribution on BFFs for a multi-body configuration. Transducer placement considerations with respect to model size, facility infrastructure, and data acquisition system capabilities, which affect the integration process, are also discussed.

Sekula, Martin K.↗

Systems and methods for increasing efficiency of ultrasound waveform tomography

Ultrasound tomography imaging methods for imaging a tissue medium with one or more ultrasound transducer arrays comprising a plurality of transducers, wherein said transducers comprise source transducers, receiving transducers. The methods include assigning a phase value or time delay to source transducers, exciting the transducers and calculating a search direction based on data relating to the excited transducers.

Huang, Lianjie↗

Pressure measurement at low temperatures

The present discussion centers on the following topics: (1) what types of pressure transducers show good potential for cryogenic use; (2) what are the output characteristics (stability, sensitivity, etc.) of a transducer when subjected to low temperature environments; and (3) are methods or apparatus available to calibrate cryogenically pressure transducers under static and dynamic conditions. Some information is available on the low-temperature performance of relatively few pressure transducer types; however, the information is either in the form of manufacturing specifications or unpublished reports. The results of this study clearly indicate that individual transducers, even from the same manufacturer, can exhibit totally different characteristics when subjected to identical cryogenic test procedures. This indicates the necessity of calibrating each transducer for use at low temperature. Also included in the discussion is the description of a static/dynamic low-temperature pressure transducer calibration facility, which is currently being developed.

Arvidson, J. M.↗

Experimental measurement of structural power flow on an aircraft fuselage

An experimental technique is used to measure the structural power flow through an aircraft fuselage with the excitation near the wing attachment location. Because of the large number of measurements required to analyze the whole of an aircraft fuselage, it is necessary that a balance be achieved between the number of measurement transducers, the mounting of these transducers, and the accuracy of the measurements. Using four transducers mounted on a bakelite platform, the structural intensity vectors at locations distributed throughout the fuselage are measured. To minimize the errors associated with using a four transducers technique the measurement positions are selected away from bulkheads and stiffeners. Because four separate transducers are used, with each transducer having its own drive and conditioning amplifiers, phase errors are introduced in the measurements that can be much greater than the phase differences associated with the measurements. To minimize these phase errors two sets of measurements are taken for each position with the orientation of the transducers rotated by 180 deg and an average taken between the two sets of measurements. Results are presented and discussed.

Cuschieri, J. M.↗

Low Differential Pressure Generator

A method and apparatus for evaluating low differential pressure transducers includes a pressure generator in the form of a piston-cylinder assembly having a piston that may be manually positioned precisely within the cylinder to change the volume and thus the pressure at respective sides of the piston. At one side of the piston the cylinder communicates with a first chamber and at the other side of the piston the cylinder communicates with a second chamber, the first and second chambers being formed within a common tank by a partition wall. The chambers each communicate with the transducer to be evaluated and a standard pre-calibrated transducer the transducers being connected fluidly in parallel so that a pressure differential between air in the two chambers resulting from movement of the piston within the cylinder is communicated to both the transducer to be evaluated and the standard transducer, and the outputs of the transducers is observed and recorded.

Stout, Stephen J.↗

Sensor Applications at Kennedy Space Center (KSC)

Transducers used at KSC (Kennedy Space Center), in support of processing and launch of flight vehicles and payloads, are designed and tested to meet specific program requirements. Any equipment, transducer or support instrumentation in direct contact or in support to flight vehicle operations is considered ground support equipment (GSE) and required to meet strict program requirements (i.e. Space Shuttle Program, Space Station Program, Evolved Expendable Launch Vehicles, etc.) Transducers used in KSC applications are based on commercial off-the-shelf (COTS) transducers and sensors. In order to fully meet KSC requirements, these transducers evolve from standard COTS to modified COTS. The Transducer and Data Acquisition Group of the Instrumentation Branch at Kennedy Space Center is responsible for providing the technical expertise as well as qualification-testing capability to transform these COTS transducers in modified COTS suitable for use around flight hardware.

Perotti, Jose M.↗

Compliance and Functional Testing of IEEE 1451.1 for NCAP-to-NCAP Communications in a Sensor Network

Distributed control in a networked environment is an irreplaceable feature in systems with remote sensors and actuators. Although distributed control was not originally designed to be networked, usage of off-the-shelf networking technologies has become so prevalent that control systems are desired to have access mechanisms similar to computer networks. However, proprietary transducer interfaces for network communications and distributed control overwhelmingly dominate this industry. Unless the lack of compatibility and interoperability among transducers is resolved, the mature level of access (that computer networking can deliver) will not be achieved in such networked distributed control systems. Standardization of networked transducer interfaces will enable devices from different manufacturers to talk to each other and ensure their plug-and-play capability. One such standard is the suite of IEEE 1451 for sensor network communication and transducer interfaces. The suite not only provides a standard interface for smart transducers, but also outlines the connection of an NCAP (network capable application processor) and transducers (through a transducer interface module TIM). This paper presents the design of the compliance testing of IEEE 1451.1 (referred to as Dot1) compatible NCAP-to-NCAP communications on a link-layer independent medium. The paper also represents the first demonstration of NCAP-to-NCAP communications with Dot1 compatibility: a tester NCAP and an NCAP under test (NUT).

Figueroa, Jorge↗

Ultrasonic bone densitometer

A device, for measuring the density of a bone structure so as to monitor the calcium content, is described. A pair of opposed spaced ultrasonic transducers are held within a clamping apparatus closely adjacent the bone being analyzed. These ultrasonic transducers incude piezoelectric crystals shaped to direct signals through the bone encompassed in the heel and finger of the subject being tested. A pulse generator is coupled to one of the transducers and generates an electric pulse for causing the transducers to generate an ultrasonic sound wave which is directed through the bone structure to the other transducer. An electric circuit, including an amplifier and a bandpass filter couples the signals from the receiver transducer back to the pulse generator for retriggering the pulse generator at a frequency proportional to the duration that the ultrasonic wave takes to travel through the bone structure being examined.

Hoop, J. M.↗

Surface acoustic wave stabilized oscillators: Additional aging results

Updated aging data for SAW oscillators with aluminum transducers on ST-cut quartz, for gold transducers on ST-cut quartz, and for aluminum transducers on SiO2/LiTaO3. Devices with gold transducers age differently (both and shape of curve) from those having a aluminum transducers indicating the transducer metallization can represent an important aging mechanism.

Source record↗

Effects of material inhomogeneities on ultrasonic measurements - The problem and a solution

Most ultrasonic measurements of materials involve the generation of an acoustic wave and the propagation of that wave from a transducer through a coupling medium to a specimen under test. After interacting with the specimen, the wave propagates through the coupling medium to a receiving transducer and is converted to an electrical signal. The information presented to the observer by the electrical signal depends on each element of the system. In this paper, the role that the receiving transducer plays in ultrasonic measurements is examined. The phase-sensitive nature of conventional receiving transducers has, for the most part, been neglected in nondestructive evaluations. This is shown to lead to significant data misinterpretation. A new acoustoelectric transducer (AET) has been developed which is phase insensitive. Comparative data obtained with both conventional and AET transducers are presented and discussed. The AET is shown to produce more accurate measurements for the cases investigated.

Heyman, J. S.↗