Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Title”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

592 records · Page 33

Dover CoreGuard Ⓡ Cybersecurity Protections for Critical Energy Infrastructure Final Report

This report documents the status of technical objectives and activities for the Department of Energy (DOE) Small Business Innovation Research (SBIR) Phase I project, titled “Dover CoreGuard Ⓡ Cybersecurity Protections for Critical Energy Infrastructure” (Award No. DE-SC0023743), undertaken by Dover Microsystems, Inc., Wayland, MA. The Principal Investigator for this project was Dr. Stephen Papa, Dover’s Chief Technology Officer (CTO). The contract PoP (Period of Performance) is scheduled for completion by February 9, 2024.

99 GENERAL AND MISCELLANEOUS↗

New Report Highlights LAMP's Role as a Robust and Reliable System for Wave Energy Converter Testing

Harnessing the power of waves requires more than just putting devices in the ocean - it takes tools that can refine and accelerate innovation before the first deployment. That's where NLR's largeamplitude motion platform, or LAMP, comes in. LAMP is a six-degree-of-freedom motion system designed to replicate the response of a wave energy converter (WEC) device in realistic ocean conditions. By letting researchers evaluate WEC performance in a safe, controlled lab environment before moving offshore, LAMP helps accelerate innovation while reducing risk. An NLR report, titled Initial Characterization of the NLR LargeAmplitude Motion Platform (https://www.nrel.gov/docs/fy26osti/93733.pdf), provides a deeper understanding of LAMP's capabilities and also lays the groundwork for future advancements in WEC testing methodologies. Researchers studied LAMP's amplitude and frequency limits across different payloads and collected data from 16 test profiles. Testing demonstrated that platform accuracy remained consistent across all payloads evaluated; researchers expect similar accuracy up to LAMP's 10,000-kilogram capacity limit. The measured position limits for single degrees of freedom experienced by WECs, including surge, sway, heave, roll, pitch, and yaw, also exceeded the original manufacturer specifications, providing new insight into the true boundaries of the system.

16 TIDAL AND WAVE POWER↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Idaho National Laboratory’s Mobile Hot Cell Transportation: Engineering Solutions for Global Disused Sealed Radioactive Sources.

Title: Idaho National Laboratory’s Mobile Hot Cell Transportation: Engineering Solutions for Global Disused Sealed Radioactive Sources. Abstract: The Mobile Hot Cell (MHC), currently under development by Idaho National Laboratory (INL) for the Off-Site Source Recovery Project (OSRP), is designed to help international partners meet the unique challenges of end-of-life radioactive material management. The MHC will provide a critical resource for countries that require assistance securing and disposing of Disused Sealed Radioactive Sources (DSRS) and orphaned sources in challenging environments, allowing these sources to be secured against misuse and nefarious activities. The MHC is a rapidly deployable system for conditioning and preparing end-of-life radioactive sources for transportation or storage. It is designed to handle sources of up to 1,000 Ci Co-60 equivalent while maintaining full radiological and biological containment. It will be deployable within 48 hours of an alert, making it ideal for emergency situations. The MHC features an operational suite for control, support racks for electronics, pneumatics, and welding systems, and a modular robust steel structure providing radiological shielding and internal robotic support. This design allows configurations for multiple device types to be conditioned and the ability to safely manage routine issues such as leaking or damaged sources. The MHC has been designed with the transportation challenges of rapid deployment to difficult environments in mind. The system weighs approximately 150,000 pounds, with individual systems breaking down into pieces not exceeding 20,000 pounds. Components are to be transportable on standard 20ft ISO containers, with shielding shells on 20ft flat racks. It is estimated that a total of eight containers and flat racks will be required. The use of 20ft containers, as opposed to 40ft containers, minimizes the impact on less developed road infrastructures, enabling the MHC to be positioned in constrained environments such as hospital parking lots. The system’s modularity also allows for deployment using smaller equipment, such as a 10-ton boom truck or forklift, which is crucial given the potential logistical challenges in different countries. This transportation strategy, evaluated in collaboration with Utah State University, ensures the MHC can be deployed via ground, rail, sea, or air, addressing the primary concern of international transport logistics.

99 - GENERAL AND MISCELLANEOUS↗

2025 ASMS Investigation of the Collision-Induced Dissociation Mechanism of Protonated TODGA with IRIS

Title (20 words): Investigation of the Collision-Induced Dissociation Mechanism of Protonated TODGA with IRIS Introduction (120 words): One of the challenges facing wide-spread adoption of nuclear power is the development of efficient separation processes for used nuclear fuel. The molecules in separation processes are subjected to an extreme environment due to the high radiation fields from the used fuel and highly acidic media used for fuel dissolution, which results in significant molecular degradation, leading to reduced process efficiency. These degradation products must be identified and studied so mitigation strategies can be developed to maintain process efficiency. However, complex systems can have many degradation products, complicating identification. Untargeted analysis tools could be used to understand radiation chemistry in complex systems. However, this would necessitate improved understanding of the gas-phase fragmentation mechanisms of fuel cycle molecules like tetraoctyldiglycolamide (TODGA). Methods (120 words): The gas-phase fragmentation of protonated TODGA was investigated using collision-induced dissociation (CID), resonance ejection, and infrared ion spectroscopy (IRIS). CID and resonance ejection experiments were conducted using a Bruker Daltonics (Bremen, Gemany) SolariX XR fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. IRIS spectra of protonated TODGA and its two CID fragmentation products were measured using a modified Bruker amaZon Speed ETD 3D quadrupole ion trap mass spectrometer coupled to the Free Electron Lasers for Infrared eXperiments (FELIX) free electron laser. Measured spectra were compared with density functional theory (DFT) calculations using the Gaussian 16, Revision C.02 software package with the ?B97X-D functional and def2-TZVPP basis sets. Candidate structures were generated using the CREST 3.0 conformational sampling software tool. Preliminary Data (300 words): Collision-induced dissociation of protonated TODGA ([C36H73N2O3]+, m/z=581.562) results two fragment ions, one at m/z=340.285 assigned as [C20H38NO3]+ and the other at m/z=312.290, assigned as [C19H38NO2]+. Based on the assigned formula and the structure of protonated TODGA, the fragment at m/z=340.285 is likely formed from elimination of neutral dioctylamine. Comparison of the IRIS spectrum of m/z=340.285 with DFT predictions suggests it contains a ring structure, and is assigned as N-octyl-N-(6-oxo-1,4-dioxan-2-ylidene)octan-1-aminium. Based on this structure and the structure of protonated TODGA, we hypothesize this fragment formed from elimination of neutral dioctylamine followed by a ring closure mechanism. Comparison of the IRIS spectrum of the fragment at m/z=312.290 with DFT predictions also indicated the presence of a ring structure, assigned as N-(1,3-dioxolan-4-ylidene)-N-octyloctan-1-aminium. This product could be formed from elimination of carbon monoxide from the ring of m/z=340.285 as a sequential fragmentation or formed directly from protonated TODGA via elimination of neutral N,N-dioctylformamide followed by a ring closure. Resonance ejection experiments where m/z=340 was continuously ejected from the IRC cell showed no decrease in intensity of m/z=312.290 across several collision energies, suggesting that the later, direct formation mechanism, dominates. The location of the ionizing proton in protonated TODGA is important for modeling the fragmentation mechanisms. DFT calculations suggested that the position of bands involving the coupled vibrations of the amide C—N and C=O bonds in TODGA are the most sensitive to proton location. Evaluation of the IRIS spectrum of protonated TODGA suggests that the ionizing proton is located between the two amid oxygens. This protonation location was calculated to lie approximately 30 kJ/mol lower in energy than the next lowest energy location, with the proton located solely on one of the amide oxygens. Novel aspect (20 words): Infrared ion spectroscopy combined with resonance ejection experiments and density functional theory to probe the collision-induced dissociation mechanism of tetraoctyldiglycolamide.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Nuclear Modeling and Simulation Using MOOSE-based Tools

Overview presentation of the variety of modeling and simulation activities for nuclear applications to be presented to visitors (professors and their students) from the United Kingdom. Presentation compiled by listed author with contributions from others at the laboratory. Others are listed within the acknowledgements of the presentation rather than a long list of authors on the title slide.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final Scientific and Technical Report

Final Scientific and Technical Report for the DOE AI grant funded under title "AI for a more precise future of the top quark"

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photovoltaic Reliability Workshop (PVRW) 2026 Oral Presentation Proceedings

Each year, the Photovoltaics Reliability Workshop (PVRW) brings together solar technology experts to discuss current and future issues in PV reliability. This document collects oral presentations that were part of PVRW 2026. Click the presentation titles in the following agenda to jump to each file. Not all talks listed in the agenda can be found in this document, as not all presentation files were provided to PVRW for inclusion in these proceedings.

14 SOLAR ENERGY↗

Golden Tide Opportunities

There is no abstract for this document. I have been invited to present my project progress to the Schmidt Sciences VIFF SaBRe team at their annual project meeting. This is work funded by DOE AFFO. The project title is Algal Feedstock Logistics

09 - BIOMASS FUELS↗

Occupational Radiation Exposure Report for Calendar Year 2023

The U.S. Department of Energy Occupational Radiation Exposure Report for Calendar 2023 presents the results of analyses of occupational radiation exposures at the U.S. Department of Energy (DOE), including the National Nuclear Security Administration (NNSA) operations, during calendar year 2023. This report includes occupational radiation exposure data for over 80,000 DOE Federal employees, contractors, and subcontractors as well as members of the public who have worked in or entered controlled areas monitored for exposure to radiation. DOE publishes this annual report to provide DOE Management, Program Offices, workers, health physicists, and other stakeholders an evaluation of DOE-wide performance regarding compliance with Title 10 of the Code of Federal Regulations (CFR) Part 835, Occupational Radiation Protection (10 CFR 835) radiation exposure limits and adherence to as low as reasonably achievable principles. This report provides a discussion regarding radiation protection and exposure reporting requirements. It also includes calendar year (CY) 2023 information and analyses regarding aggregate, individual, site, DOE Program, transient individuals’ dose, as well as a historical review of DOE exposure data. DOE continues to be diligent in protecting its workers and the public from exposure to radiation from DOE operations as illustrated by the results contained in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrated Methane Monitoring Platform Extension, Volume I: Final Technical Report

The IMMPE project, DE-FE0032284, was to enhance methane monitoring technologies and their applications across various natural gas asset classes. The scope included deploying advanced methane detection and monitoring technologies to identify and mitigate fugitive methane emissions, measuring emission rates, and assessing impacts. The findings included the successful mitigation of identified emissions and quantification of emission rates. A key outcome was the development of a comprehensive template and summary of recommendations for methane emissions monitoring, which is replicable for both upstream and downstream applications. Furthermore, the project emphasized the importance of education by providing training opportunities for technicians and regulators, thereby fostering awareness and promoting the adoption of cost-effective methane emissions monitoring and management techniques.

02 PETROLEUM↗

Environmental Performance Report 2025: Annual Site Environmental Report per the U.S. Department of Energy Order 231.1B Chg 1

The National Laboratory of the Rockies (NLR) Environmental Performance Report provides a description of the laboratory's environmental management activities in calendar year 2025, including information on environmental performance, environmental compliance activities and status, and environmental protection programs, highlights, and successes. The purpose of this report is to ensure that the U.S. Department of Energy (DOE) and the public receive timely, accurate information about events that have positively affected or could adversely affect the health and safety of the public or workers, the environment, or the operations of DOE facilities. This report meets the DOE requirements of the Annual Site Environmental Report (ASER) and has been prepared in accordance with DOE Order 231.1B Chg 1, Environment, Safety and Health Reporting.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗