Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tipping points”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Peridynamic modeling of fracture in elastomers and composites.

The peridynamic model of solid mechanics is a mathematical theory designed to provide consistent mathematical treatment of deformations involving discontinuities, especially cracks. Unlike the partial differential equations (PDEs) of the standard theory, the fundamental equations of the peridynamic theory remain applicable on singularities such as crack surfaces and tips. These basic relations are integro-differential equations that do not require the existence of spatial derivatives of the deformation, or even continuity of the deformation. In the peridynamic theory, material points in a continuous body separated from each other by finite distances can interact directly through force densities. The interaction between each pair of points is called a bond. The dependence of the force density in a bond on the deformation provides the constitutive model for a material. By allowing the force density in a bond to depend on the deformation of other nearby bonds, as well as its own deformation, a wide spectrum of material response can be modelled. Damage is included in the constitutive model through the irreversible breakage of bonds according to some criterion. This criterion determines the critical energy release rate for a peridynamic material. In this talk, we present a general discussion of the peridynamic method and recent progress in its application to penetration and fracture in nonlinearly elastic solids. Constitutive models are presented for rubbery materials, including damage evolution laws. The deformation near a crack tip is discussed and compared with results from the standard theory. Examples demonstrating the spontaneous nucleation and growth of cracks are presented. It is also shown how the method can be applied to anisotropic media, including fiber reinforced composites. Examples show prediction of impact damage in composites and comparison against experimental measurements of damage and delamination.

36 MATERIALS SCIENCE↗

A miniaturized, high frequency mechanical scanner for high speed atomic force microscope using suspension on dynamically determined points

One of the major limitations in the speed of the atomic force microscope (AFM) is the bandwidth of the mechanical scanning stage, especially in the vertical (z) direction. According to the design principles of “light and stiff” and “static determinacy,” the bandwidth of the mechanical scanner is limited by the first eigenfrequency of the AFM head in case of tip scanning and by the sample stage in terms of sample scanning. Due to stringent requirements of the system, simply pushing the first eigenfrequency to an ever higher value has reached its limitation. We have developed a miniaturized, high speed AFM scanner in which the dynamics of the z-scanning stage are made insensitive to its surrounding dynamics via suspension of it on specific dynamically determined points. This resulted in a mechanical bandwidth as high as that of the z-actuator (50 kHz) while remaining insensitive to the dynamics of its base and surroundings. The scanner allows a practical z scan range of 2.1 μm. We have demonstrated the applicability of the scanner to the high speed scanning of nanostructures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Southeast Regional Carbon Sequestration Partnership (SECARB) Collect Repeat 3-D Survey

The baseline 3-D survey of Cranfield was collected by Denbury Onshore LLC. in 2007 and data provided to the SECARB Early team at the BEG as a major cost share contribution for Phase II. The baseline 3-D survey covered the entire Cranfield Field as well into the surrounding brine-saturated water leg. This data remains extremely valuable in characterization for Phase III, and has been analyzed extensively. Bureau researchers Hongliu Zeng and Tip Meckel have analyzed the baseline 3-D to develop reservoir models. For example, Zeng enhanced seismic data to extract textures suggestive of high sinuosity aggradational point bar from the lower Tuscaloosa interval. Meckel assessed the logs and seismically imaged structure to better define the oil-water contact to assure that the DAS experiment was set in the water leg, and mapped the graben-edge fault that separates the Phase II and the Phase III areas. Additional characterization work continues by a number of students under funding from SECARB (Kordi dissertation) as well as additional efforts under BES funding though the CFSES project.

01 COAL, LIGNITE, AND PEAT↗

Pattern selection in a boundary-layer model of dendritic growth in the presence of impurities

Presently analyzed, in the context of a boundary-layer model, is the problem of pattern selection in dendritic growth in a situation where impurities are present in the undercooled liquid. It is found that the tip-velocity selection criterion that has been proposed recently for the geometrical model and the boundary-layer model of a pure substance can be extended, in a nontrivial way, to this more complex situation where two coupled diffusion fields (temperature and solute) determine the interface dynamics. This model predicts a sharp enhancement of tip velocity in good qualitative agreement with experiment. This agreement is consistent with the conjecture that a solvability condition can be used to determine the operating point of the dendrite in the full nonlocal problem.

Karma, A.↗

Winglets on low aspect ratio wings

The drag reduction potentially available from the use of winglets at the tips of low aspect ratio (1.75-2.67) wings with pronounced (45-60 deg) leading edge sweep is assessed numerically for the case of a cruise design point at Mach of 0.8 and a lift coefficient of 0.3. Both wing-winglet and wing-alone design geometries are derived from a linear-theory, minimum induced drag design methodology. Relative performance is evaluated with a nonlinear extended small disturbance potential flow analysis code. Predicted lift coefficient/pressure drag coefficient increases at equal lift for the wing-winglet configurations over the wing-alone planform are of the order of 14.6-15.8, when boundary layer interaction is included.

Kuhlman, John M.↗

Level Indicator On A Tubular Inside Micrometer

Leveling helps to ensure accurate measurements. Attachment helpful because in some situations that involve measurement of large, tight-tolerance inside dimensions, inside micrometers not held level between contact point give inaccurate readings. User adjusts position and orientation of micrometer and verifies level by observing bubble in level indicator. Upon feeling correct drag between micrometer tips and workpiece, user confident that tool used correctly and accurate measurement obtained.

Malinzak, R. Michael↗

Carbon Nanofibers Synthesized on Selective Substrates for Nonvolatile Memory and 3D Electronics

A plasma-enhanced chemical vapor deposition (PECVD) growth technique has been developed where the choice of starting substrate was found to influence the electrical characteristics of the resulting carbon nanofiber (CNF) tubes. It has been determined that, if the tubes are grown on refractory metallic nitride substrates, then the resulting tubes formed with dc PECVD are also electrically conducting. Individual CNFs were formed by first patterning Ni catalyst islands using ebeam evaporation and liftoff. The CNFs were then synthesized using dc PECVD with C2H2:NH3 = [1:4] at 5 Torr and 700 C, and approximately equal to 200-W plasma power. Tubes were grown directly on degenerately doped silicon <100> substrates with resistivity rho approximately equal to 1-5 meterohm-centimeter, as well as NbTiN. The approximately equal to 200-nanometer thick refractory NbTiN deposited using magnetron sputtering had rho approximately equal to 113 microohm-centimeter and was also chemically compatible with CNF synthesis. The sample was then mounted on a 45 beveled Al holder, and placed inside a SEM (scanning electron microscope). A nanomanipulator probe stage was placed inside the SEM equipped with an electrical feed-through, where tungsten probes were used to make two-terminal electrical measurements with an HP 4156C parameter analyzer. The positive terminal nanoprobe was mechanically manipulated to physically contact an individual CNF grown directly on NbTiN as shown by the SEM image in the inset of figure (a), while the negative terminal was grounded to the substrate. This revealed the tube was electrically conductive, although measureable currents could not be detected until approximately equal to 6 V, after which point current increased sharply until compliance (approximately equal to 50 nA) was reached at approximately equal to 9.5 V. A native oxide on the tungsten probe tips may contribute to a tunnel barrier, which could be the reason for the suppressed transport at low biases. Currents up to approximately 100 nA could be cycled, which are likely to propagate via the tube surface, or sidewalls, rather than the body, which is shown by the I-V in figure (a). Electrical conduction via the sidewalls is a necessity for dc NEMS (nanoelectromechanical system) applications, more so than for the field emission applications of such tubes. During the tests, high conductivity was expected, because both probes were shorted to the substrate, as shown by curve 1 in the I-V characteristic in figure (b). When a tube grown on NbTiN was probed, the response was similar to the approximately equal to 100 nA and is represented by curve 2 in figure (b), which could be cycled and propagated via the tube surface or the sidewalls. However, no measureable currents for the tube grown directly on Si were observed as shown by curve 3 in figure (b), even after testing over a range of samples. This could arise from a dielectric coating on the sidewalls for tubes on Si. As a result of the directional nature of ion bombardment during dc PECVD, Si from the substrate is likely re-sputtered and possibly coats the sidewalls.

Kaul, Anupama B.↗

Method for polishing the end of an optical fiber

A method of polishing a roof-shaped, or bevelled, tip having a predetermined angle on the end of an optical fiber is disclosed. The method comprises placing an optical fiber in contact with an abrasive tape at an angle corresponding to the desired predetermined angle. The fiber is moved towards the tape beyond the point of contact so as to cause a bend in the fiber. Upon moving the abrasive tape, the compliance of the fiber, by virtue of the bend, provides a pressure of the fiber against the tape to enable polishing to occur. As polishing continues the pressure decreases until enough material is removed so as to eliminate the bend and impart the predetermined angle to the fiber tip. The fiber may be rotated to polish the other side in a similar manner, if so desired.

Dholakia, Anil R.↗

A vision-based end-point control for a two-link flexible manipulator

The measurement and control of the end-effector position of a large two-link flexible manipulator are investigated. The system implementation is described and an initial algorithm for static end-point positioning is discussed. Most existing robots are controlled through independent joint controllers, while the end-effector position is estimated from the joint positions using a kinematic relation. End-point position feedback can be used to compensate for uncertainty and structural deflections. Such feedback is especially important for flexible robots. Computer vision is utilized to obtain end-point position measurements. A look-and-move control structure alleviates the disadvantages of the slow and variable computer vision sampling frequency. This control structure consists of an inner joint-based loop and an outer vision-based loop. A static positioning algorithm was implemented and experimentally verified. This algorithm utilizes the manipulator Jacobian to transform a tip position error to a joint error. The joint error is then used to give a new reference input to the joint controller. The convergence of the algorithm is demonstrated experimentally under payload variation. A Landmark Tracking System (Dickerson, et al 1990) is used for vision-based end-point measurements. This system was modified and tested. A real-time control system was implemented on a PC and interfaced with the vision system and the robot.

Obergfell, Klaus↗

The evolutionary rate dynamically tracks changes in HIV-1 epidemics

Large-sequence datasets provide an opportunity to investigate the dynamics of pathogen epidemics. Thus, a fast method to estimate the evolutionary rate from large and numerous phylogenetic trees becomes necessary. Based on minimizing tip height variances, we optimize the root in a given phylogenetic tree to estimate the most homogenous evolutionary rate between samples from at least two different time points. Simulations showed that the method had no bias in the estimation of evolutionary rates and that it was robust to tree rooting and topological errors. We show that the evolutionary rates of HIV-1 subtype B and C epidemics have changed over time, with the rate of evolution inversely correlated to the rate of virus spread. For subtype B, the evolutionary rate slowed down and tracked the start of the HAART era in 1996. Subtype C in Ethiopia showed an increase in the evolutionary rate when the prevalence increase markedly slowed down in 1995. Thus, we show that the evolutionary rate of HIV-1 on the population level dynamically tracks epidemic events.

59 BASIC BIOLOGICAL SCIENCES↗

Small axial compressor technology, volume 1

A scaled single-stage, highly-loaded, axial-flow transonic compressor was tested at speeds from 70 to 110% design equivalent speed to evaluate the effects of scaling compromises and the individual and combined effects of rotor tip running clearance and rotor shroud casing treatment on the overall and blade element performance. At design speed and 1% tip clearance the stage demonstrated an efficiency of 83.2% at 96.4% design flow and a pressure ratio of 1.865. Casing treatment increased design speed surge margin 2.0 points to 12.8%. Overall performance was essentially unchanged. An increase in rotor running clearance to 2.2%, with smooth casing, reduced design speed peak efficiency 5.7 points, flow by 7.4%, pressure ratio to 1.740, and surge margin to 5.4%. Reinstalling casing treatment regained 3.5 points in design speed peak efficiency, 4.7% flow, increased pressure ratio to 1.800 and surge margin to 8.7%.

Holman, F. F.↗

Topology of vortices in conical flow

The possibility of the existence of a viscous vortex in a conical flow is discussed. Existence of a viscous vortex is shown to be consistent with a flow-field model where only the velocity components and the total enthalpy behave conically. Existence of a viscous vortex is not consistent with the fully conical, flow-field model; however, far from the nose tip, the physical flow quantities tend to behave asymptotically as a full conical flow. Such a viscous vortex, when it exists, must spiral inwards to the focal point. It can be used as a reasonable model to start numerical solutions of various kinds.

Almosnino, D.↗

Tests of the NACA 0025 and 0035 Airfoils in the Full-Scale Wind Tunnel

This report presents the results of an investigation conducted in the NACA full-scale wind tunnel to determine the aerodynamic characteristics of the 6 by 36-foot rectangular NACA 0025 and 0035 airfoils. The aerodynamic characteristics of the plain airfoils with rounded and square tips were determined by force tests through a complete angle-of-attack range, in addition, the profile drag was determined by the momentum method. The transition points on the airfoils were located by boundary-layer determinations with small total-head and static tubes. Each airfoil was also tested with a 0.20c full-span split flap. Tuft surveys were included to show the progressive breakdown of flow with increasing angles of attack. Previously published data from tests of the NACA 0009, 0012, and 0018 airfoils in the full-scale tunnel have been included in the summary curves.

Bullivant, W Kenneth↗

An "Inefficient Fin" Non-Dimensional Parameter to Measure Gas Temperatures Efficiently

A gas containment vessel that is not in thermal equilibrium with the bulk gas can affect its temperature measurement. The physical nature of many gas dynamics experiments often makes the accurate measurement of temperature a challenge. The environment itself typically requires that the thermocouple be sheathed, both to protect the wires and hot junction of the instrument from their environment, and to provide a smooth, rigid surface for pressure sealing of the enclosure. However, that enclosure may also be much colder than the gas to be sensed, or vice-versa. Either way, the effect of such gradients is to potentially skew the temperature measurements themselves, since heat may then be conducted by the instrument. Thermocouple designers traditionally address this problem by insulating the sheath from the thermocouple leads and hot junction as much as possible. The thermocouple leads are typically packed in a ceramic powder inside the sheath, protecting them somewhat from temperature gradients along the sheath, but there is no effective mechanism to shield the sheath from the enclosure body itself. Standard practice dictates that thermocouples be used in installations that do not present large thermal gradients along the probe. If this conduction dominates heat transfer near the tip of the probe, then temperature measurements may be expected to be skewed. While the same problem may be experienced in the measurement of temperature at various points within a solid in a gradient, it tends to be aggravated in the measurements of gas temperature, since heat transfer dependent on convection is often less efficient than conduction along the thermocouple. The proposed solution is an inefficient fin thermocouple probe. Conventional wisdom suggests that in many experiments where gas flows through an enclosure (e.g., flow in pipe, manifold, nozzle, etc.), the thermocouple be introduced flush to the surface, so as not to interfere with the flow. In practice, however, many such experiments take place where the flow is already turbulent, so that a protruding thermocouple probe has a negligible effect on the flow characteristics. The key question then becomes just how far into the flow should a thermocouple protrude in order to properly sense the gas temperature at that point. Modeling the thermocouple as an "inefficient fin" directly addresses this question. The appropriate assumptions in this case are: one-dimensional conduction along the fin; steady-state, constant, and homogeneous thermal conductivity; negligible radiation; and a uniform, constant heat transfer coefficient over the probe surface. It is noted that the nature of the ceramic-filled probe makes the key assumption of homogeneous thermal conductivity that much more conservative.

Lemieux, Patrick↗

Application of a Metal Artifact Reduction Algorithm for C-Arm Cone-Beam CT: Impact on Image Quality and Diagnostic Confidence for Bronchial Artery Embolization

Objective: The objective of this study was to evaluate the potential benefit of a dedicated cone-beam-CT streak metal artifact removal technique (SMART) in terms of both image quality and diagnostic confidence in patients undergoing bronchial artery embolization. Methods: A total of 17 patients were included in this retrospective study. The SMART algorithm was applied to images containing streak artifacts generated by a radiopaque intra-arterial catheter tip. Quantitative evaluation of artifact severity was performed via measurement of the Hounsfield units along a closed loop surrounding the catheter tip and was conducted in the frequency domain following the application of the discrete Fourier transform to the measured data. A high proportion of power in the low frequencies of the resulting spectrum indicated a high level of streak artifacts. Qualitative evaluation of diagnostic confidence was performed using a 4-point Likert scale. Results: Both quantitative and qualitative evaluation demonstrated a significant reduction in artifact severity using the SMART algorithm. Quantitative evaluation demonstrated a mean artifact reduction of 22.5% using SMART compared to non-SMART images (p < 0.001). Qualitative evaluation demonstrated the greatest artifact reduction at the inner and outer aortic curvature, as well as immediately surrounding the tip of the catheter. In 6 of 17 cases, the use of the SMART algorithm yielded additional clinical information, increasing mean diagnostic confidence from 3.17 to 3.78 (p < 0.001). Conclusion: The SMART algorithm allows for efficient reduction of metal artifacts introduced by radiopaque catheter tips during cone-beam CT. Using this algorithm, diagnostic images of the aortic arch were significantly improved both quantitatively and qualitatively, yielding clinically relevant levels of enhanced diagnostic confidence. These results demonstrate that the SMART algorithm improves diagnostic and clinical characterization of the course of bronchial arteries on CBCT images, potentially improving the accuracy and clinical efficacy of bronchial artery embolization. Level of Evidence: 3.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RITE Gen5 KHPS Levelized Cost of Energy

Levelized Cost of Energy analysis for Verdant Power Gen5 KHPS utilizing annualized AEP based on actual energy generation at the RITE Project during 2020-21. The WEC devices analyzed include attenuator, point absorber, oscillating wave surge converter, oscillating water column, overtopping/terminator device, submerged pressure differential, bulge wave, and rotating mass type wave energy converter devices. The CEC devices analyzed include horizontal axis turbine, vertical axis turbine, oscillating hydrofoil, enclosed tips (Venturi), Archimedes screw, and tidal kite type current energy converter devices.

16 TIDAL AND WAVE POWER↗

Some observed effects of part-span dampers on rotating blade row performance near design point

Detailed measured radial distributions of flow parameters for eight rotors with part-span dampers are used to study the effects of dampers on rotor performance and flow parameters at near design operation. All rotors had a blade tip diameter of about 20 in. and operated at a blade tip speed of about 1400 ft/sec. Several examples demonstrate that, when the local loss variations in the damper flow region are included in an aerodynamic design or analysis procedure, the computed spanwise distributions of flow parameters compare closely with measured distributions.

Esgar, G. M.↗

Standardization of Head and Neck Contouring Using the Acanthiomeatal Line

The purpose of this study was to determine the perceived and actual chin position(s) used for radiotherapy of head-and-neck cancers in a variety of clinical settings. Dosimetrists were asked to describe the external landmarks used to set the chin position. The lateral treatment planning radiographic figures in Ang's textbook, Radiotherapy for Head and Neck Cancers: Indications and Techniques, were analyzed for chin position by drawing a horizontal line from the tip of the chin to the cervical spine. The physicians at 7 departments were asked to rate the chin positions used in their departments for head-and-neck simulations. Choices included: (1) mildly flexed, (2) neutral, (3) mildly extended, and (4) hyperextended. In addition, each center was asked to select 2 representative cases to show routine chin position. The dosimetrists fixed the chin in neutral position by placing a virtual plane defined by 3 points (the base of the nasal septum [acanthus] and the external auditory canals) perpendicular to the table top. The type of head holder was irrelevant. Eighty-two percent (31/38) of the figures in Ang's text showed positioning in the neutral position (tip of the chin intersected the cervical spine between C2-3/C3-4). Most (71.4%) of the radiotherapists thought their patients were treated in the hyperextended neck position but, in fact, 85.7% (12/14) of the simulations showed a neural neck position. Reproducible chin positioning can be obtained by using the acanthiomeatal line. Consistent use of this technique will create a uniformly positioned set of axial co-images that have consistent appearance of avoidance and lymphatic areas. This will simplify contouring on axial computed tomography (CT) images of the neck. Standardizing the chin position is an important step to developing a standardized atlas and developing an information tool for automated contouring.

61 RADIATION PROTECTION AND DOSIMETRY↗