Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Structural Analysis of the Redesigned Ice/Frost Ramp Bracket

This paper describes the interim structural analysis of a redesigned Ice/Frost Ramp bracket for the Space Shuttle External Tank (ET). The proposed redesigned bracket consists of mounts for attachment to the ET wall, supports for the electronic/instrument cables and propellant repressurization lines that run along the ET, an upper plate, a lower plate, and complex bolted connections. The eight nominal bolted connections are considered critical in the summarized structural analysis. Each bolted connection contains a bolt, a nut, four washers, and a non-metallic spacer and block that are designed for thermal insulation. A three-dimensional (3D) finite element model of the bracket is developed using solid 10-node tetrahedral elements. The loading provided by the ET Project is used in the analysis. Because of the complexities associated with accurately modeling the bolted connections in the bracket, the analysis is performed using a global/local analysis procedure. The finite element analysis of the bracket identifies one of the eight bolted connections as having high stress concentrations. A local area of the bracket surrounding this bolted connection is extracted from the global model and used as a local model. Within the local model, the various components of the bolted connection are refined, and contact is introduced along the appropriate interfaces determined by the analysts. The deformations from the global model are applied as boundary conditions to the local model. The results from the global/local analysis show that while the stresses in the bolts are well within yield, the spacers fail due to compression. The primary objective of the interim structural analysis is to show concept viability for static thermal testing. The proposed design concept would undergo continued design optimization to address the identified analytical assumptions and concept shortcomings, assuming successful thermal testing.

Phillips, D. R.↗

Methane Lunar Surface Thermal Control Test

NASA is considering propulsion system concepts for future missions including human return to the lunar surface. Studies have identified cryogenic methane (LCH4) and oxygen (LO2) as a desirable propellant combination for the lunar surface ascent propulsion system, and they point to a surface stay requirement of 180 days. To meet this requirement, a test article was prepared with state-of-the-art insulation and tested in simulated lunar mission environments at NASA GRC. The primary goals were to validate design and models of the key thermal control technologies to store unvented methane for long durations, with a low-density high-performing Multi-layer Insulation (MLI) system to protect the propellant tanks from the environmental heat of low Earth orbit (LEO), Earth to Moon transit, lunar surface, and with the LCH4 initially densified. The data and accompanying analysis shows this storage design would have fallen well short of the unvented 180 day storage requirement, due to the MLI density being much higher than intended, its substructure collapse, and blanket separation during depressurization. Despite the performance issue, insight into analytical models and MLI construction was gained. Such modeling is important for the effective design of flight vehicle concepts, such as in-space cryogenic depots or in-space cryogenic propulsion stages.

Plachta, David W.↗

An Assessment of MELCOR 2.1: Containment Thermal-Hydraulic Tests in the Heissdampfreaktor (HDR) Facility

MELCOR is being developed at Sandia National Laboratories for the U.S. Nuclear Regulatory Commission. MELCOR is a fully integrated code (encompassing the reactor coolant system and the containment building) that models the progression of postulated accidents in light water reactor power plants. It provides a capability for independently auditing analyses submitted by reactor manufacturers and utilities. In order to assess the adequacy of containment thermal - hydraulic modeling incorporated in the MELCOR code, a key containment test facility was analyzed. This report documents MELCOR code calculations for simulating steam - water blowdown tests performed in the Heissdampfreaktor ( HDR) de-commissioned containment facility located near Frankfurt , Germany . These tests are a series of blowdown experiments in a large scaled test facility ; including some tests with the addition of hydrogen release which are intended to simulate a variety of postulated break s inside large containment buildings. The key objectives of this MELCOR assessment are to study: (1) the expansion and transport of high energy steam - water releases, (2) heat and mass transfer to structural passive heat sinks, and (3) containment gas mixing and stratification. Moreover, MELCOR results are compared to the CONTAIN code for the same tests.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Computational Methodology for Simulating Thermal Loss Testing of the Advanced Stirling Convertor

The U.S. Department of Energy (DOE) and Lockheed Martin Space Systems Company (LMSSC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. This generator would use two highefficiency Advanced Stirling Convertors (ASCs), developed by Sunpower Inc. and NASA Glenn Research Center (GRC). The ASCs convert thermal energy from a radioisotope heat source into electricity. As part of ground testing of these ASCs, different operating conditions are used to simulate expected mission conditions. These conditions require achieving a particular operating frequency, hot end and cold end temperatures, and specified electrical power output for a given net heat input. In an effort to improve net heat input predictions, numerous tasks have been performed which provided a more accurate value for net heat input into the ASCs, including the use of multidimensional numerical models. Validation test hardware has also been used to provide a direct comparison of numerical results and validate the multi-dimensional numerical models used to predict convertor net heat input and efficiency. These validation tests were designed to simulate the temperature profile of an operating Stirling convertor and resulted in a measured net heat input of 244.4 W. The methodology was applied to the multi-dimensional numerical model which resulted in a net heat input of 240.3 W. The computational methodology resulted in a value of net heat input that was 1.7 percent less than that measured during laboratory testing. The resulting computational methodology and results are discussed.

Reid, Terry V.↗

Modeling the Extremely Lightweight Zerodur Mirror (ELZM) Thermal Soak Test

Exoplanet science requires extreme wavefront stability (10 pm change/10 minutes), so every source of wavefront error (WFE) must be characterized in detail. This work illustrates the testing and characterization process that will be used to determine how much surface figure error (SFE) is produced by mirror substrate materials' CTE distributions. Schott's extremely lightweight Zerodur mirror (ELZM) was polished to a sphere, mounted, and tested at Marshall Space Flight Center (MSFC) in the X-Ray and Cryogenic Test Facility (XRCF). The test transitioned the mirror's temperature from an isothermal state at 292K to isothermal states at 275K, 250K and 230K to isolate the effects of the mirror's CTE distribution. The SFE was measured interferometrically at each temperature state and finite element analysis (FEA) has been completed to assess the predictability of the change in the mirror's surface due to a change in the mirror's temperature. The coefficient of thermal expansion (CTE) distribution in the ELZM is unknown, so the analysis has been correlated to the test data. The correlation process requires finding the sensitivity of SFE to a given CTE distribution in the mirror. A novel hand calculation is proposed to use these sensitivities to estimate thermally induced SFE. The correlation process was successful and is documented in this paper. The CTE map that produces the measured SFE is in line with the measured data of typical boules of Schott's Zerodur glass.

Brooks, Thomas E.↗

Thermal Analysis and Test Program to Evaluate Passenger Compartment Thermal Load Reduction and Improve: Cooperative Research and Development Final Report, CRADA number CRD-07-00231

This activity supported a GM and NREL collaborative exploration of strategies to minimize and alleviate the temperature rise in the passenger compartment of an automobile during prolonged exposure to solar radiation in hot climates. It developed and exercised math-based models to simulate the air flow and thermal environment in the passenger compartment in order to compare the effectiveness ofthe strategies. This activity also assessed the strategies using vehicle tests.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Permeation testing of thermal power plant cooling water impacts of Graphite Oxide (GO)/polymer membranes

The purpose of this project was to investigate how thermoelectric power plant cooling water impacts the energy demands, permeance, and ion rejection of GO/polymer membranes using extended permeation testing. Treatment of cooling tower blowdown water is challenging since this water contains scalants (e.g.: silica, calcium sulfate, calcium carbonate) which can precipitate on membranes, decreasing membrane efficiency and lifetime. In this collaboration with EPRI and a Southwestern US utility, the performance of GO/polymer membranes in desalinating cooling tower blowdown water from three natural-gas fueled power plants was evaluated. Results of cross-flow desalination test durations of three to four weeks demonstrated the long-term stability of the membranes. GO/polymer desalination membranes were shown to tolerate drinking-water level chlorination, which could reduce capital and operational costs. Biofouling and scale formation were minimal on the GO surface, suggesting that industry standard intensive cleaning steps could be reduced. Results also demonstrated pressure-tunable rejection which would allow treat-to-need water recycling, thus likely reducing energy costs for these membranes. Further development of biofouling and scaling resistant desalination membranes could lead to reduced cost for water treatment, potentially allowing for greater use of non-traditional water supplies for thermoelectric power plants.

Biedermann, Laura↗

Characterization of space station multilayer insulation damage due to hypervelocity space debris impact

Four main tasks were accomplished. The first three tasks were related to the goal of measuring the degradation of the insulating capabilities of Space Station multilayer insulation (MLI) due to simulated space debris impacts at hypervelocities. The last task was associated with critically reviewing a Boeing document on the fracture characteristics of the Space Station pressure wall when subjected to a simulated hypervelocity space debris impact. In Task 1, a thermal test procedure for impact damaged MLI specimens was written. In Task 2, damaged MLI specimens were prepared. In Task 3, a computer program was written to simulate MLI thermal tests. In Task 4, the author reviewed a Boeing document describing hypervelocity impact testing on biaxially stressed plates.

Rule, William Keith↗

Coefficient of Thermal Expansion Test Report

A scale-up version of a fused deposition modeling (FDM) machine known as Big Area Additive Manufacturing (BAAM) has been developed in the Manufacturing Demonstration Facility (MDF) at the Oak Ridge National Laboratory. In this report, we present the coefficient of thermal expansion (CTE) of specimens manufactured with the BAAM system in directions parallel and perpendicular to the deposition direction. The CTE describes how the length of a material changes with a change in temperature at a constant pressure and it is computed as where ΔL denotes the change in length, $$CTE = \frac{^{\Delta L}/_{L_0}}{\Delta T}$$ L 0 the initial length, and ΔT is the change in temperature. The CTE values shown here were measured in a Thermo-Mechanical Analyzer (TMA). The tests were performed according the adaptation of the ASTM E831 provided by TA company instruments technical service using the TMAQ400.

36 MATERIALS SCIENCE↗

Main characteristics of the Large Space Simulation (LSS)

The European Space Agency (ESA) has started the implementation of a Large Space Simulator at its European Space Research and Technology Centre (ESTEC) located at Noordwijk, The Netherlands. After its completion in early 1986 this facility will enable mechanical and thermal tests on large satellites. The chamber will be equipped with a collimated solar beam of 6 Meter diameter. In addition Infrared equipment is available as alternative or complementary source of thermal radiation. Also controlled variation of shroud temperatures can be utilised for thermal testing or temperature cycling of hardware. The "Design and Definition Phase" of the project has been successfully completed by the end of 1983. The paper presents the basic concept and major design aspects of this facility. At the time of the conference, the large chamber is already under construction on site.

Peter W. Brinkmann↗

The Langley thermal protection system test facility: A description including design operating boundaries

A description of the Langley thermal protection system test facility is presented. This facility was designed to provide realistic environments and times for testing thermal protection systems proposed for use on high speed vehicles such as the space shuttle. Products from the combustion of methane-air-oxygen mixtures, having a maximum total enthalpy of 10.3 MJ/kg, are used as a test medium. Test panels with maximum dimensions of 61 cm x 91.4 cm are mounted in the side wall of the test region. Static pressures in the test region can range from .005 to .1 atm and calculated equilibrium temperatures of test panels range from 700 K to 1700 K. Test times can be as long as 1800 sec. Some experimental data obtained while using combustion products of methane-air mixtures are compared with theory, and calibration of the facility is being continued to verify calculated values of parameters which are within the design operating boundaries.

Klich, G. F.↗

Quality concerns caused by quality control — deformation of silicon strip detector modules in thermal cycling tests

The ATLAS experiment at the Large Hadron Collider (LHC) is currently preparing to replace its present Inner Detector (ID) with the upgraded, all-silicon Inner Tracker (ITk) for its High-Luminosity upgrade (HL-LHC). The ITk will consist of a central pixel tracker and the outer strip tracker, consisting of about 19,000 strip detector modules. Each strip module is assembled from up to two sensors, and up to five flexes (depending on its geometry) in a series of gluing, wirebonding and quality control steps. During detector operation, modules will be cooled down to temperatures of about -35 °C (corresponding to the temperature of the support structures on which they will be mounted) after being initially assembled and stored at room temperature. In order to ensure compatibility with the detector's operating temperature range, modules are subjected to thermal cycling as part of their quality control process. Ten cycles between -35 °C and +40 °C are performed for each module, with full electrical characterisation tests at each high and low temperature point. As part of an investigation into the stress experienced by modules during cooling, it was observed that modules generally showed a change in module shape before and after thermal cycling. This paper presents a summary of the discovery and understanding of the observed changes, connecting them with excess module stress, as well as the resulting modifications to the module thermal cycling procedure.

47 OTHER INSTRUMENTATION↗

Thermal Modeling and Testing of High-Temperature Refractory Ceramic Insulation Felts

Heat transfer in high-temperature, high-porosity, flexible refractory ceramic fibrous insulation felts is investigated. Heat transfer in these insulation materials consists of combined gas conduction, solid conduction, and radiation modes, with the precise theoretical modeling of the latter two modes being formidable. A semi-empirical model that requires inverse methods and steady-state thermal test data to infer some of the required model parameters is further developed in this study, and applied to five insulation materials for temperatures between 300 K and 1900 K. The steady-state thermal test setup at NASA Langley Research Center with recent modifications to increase its testing capability to 1900 K is discussed. Design considerations to ensure one-dimensional heat transfer in the test setup are described. Test data and corresponding thermal models for alumina and zirconia-based fibrous insulation felts are presented. Furthermore, test data and thermal models on two fibrous insulation samples containing additives to further suppress either radiation or gas conduction modes of heat transfer are presented. Previously published alumina-based insulation data are also re-processed using the updated modeling methodology. The significance of various heat transfer modes in typical insulation samples is discussed and used to provide general guidance on optimum insulation layups.

Kamran Daryabeigi↗

Phenomena associated with bench and thermal-vacuum testing of super conductors - Heat pipes.

Test failures of heat pipes occur when the functional performance is unable to match the expected design limits or when the power applied to the heat pipe (in the form of heat) is distributed unevenly through the system, yielding a large thermal gradient. When a thermal gradient larger than expected is measured, it normally occurs in the evaporator or condenser sections of the pipe. Common causes include evaporator overheating, condenser dropout, noncondensable gas formation, surge and partial recovery of evaporator temperatures, masking of thermal profiles, and simple malfunctions due to leaks and mechanical failures or flaws. Examples of each of these phenomena are described along with corresponding failure analyses and corrective measures.

Marshburn, J. P.↗

Cyclic Cryogenic Thermal-Mechanical Testing of an X-33/RLV Liquid Oxygen Tank Concept

An important step in developing a cost-effective, reusable, launch vehicle is the development of durable, lightweight, insulated, cryogenic propellant tanks. Current cryogenic tanks are expendable so most of the existing technology is not directly applicable to future launch vehicles. As part of the X-33/Reusable Launch Vehicle (RLV) Program, an experimental apparatus developed at the NASA Langley Research Center for evaluating the effects of combined, cyclic, thermal and mechanical loading on cryogenic tank concepts was used to evaluate cryogenic propellant tank concepts for Lockheed-Martin Michoud Space Systems. An aluminum-lithium (Al 2195) liquid oxygen tank concept, insulated with SS-1171 and PDL-1034 cryogenic insulation, is tested under simulated mission conditions, and the results of those tests are reported. The tests consists of twenty-five simulated Launch/Abort missions and twenty-five simulated flight missions with temperatures ranging from -320 F to 350 F and a maximum mechanical load of 71,300 lb. in tension.

Rivers, H. Kevin↗

Developmental and Cryogenic Thermal Vacuum (TVAC) Testing Lessons Learned

Developmental thermal vacuum (TVAC) testing is a critical step in maturing hardware designs and validating performance prior to flight qualification. Unlike qualification or acceptance testing, developmental testing provides flexibility to explore design margins, uncover integration challenges, and refine test approaches before formal verification activities begin. This presentation highlights the value of developmental testing while sharing common pitfalls encountered during developmental TVAC campaigns. Lessons learned from hands-on testing experience, including extensive developmental testing at cryogenic temperatures, will be shared in this presentation. Topics include test planning and preparation, instrumentation strategies, contamination control considerations, troubleshooting unexpected anomalies, and approaches for staying on schedule while meeting test objectives. The audience will gain practical insights and best practices that can improve test efficiency, reduce risk, and enhance the overall success of future developmental TVAC efforts.

Mackenzie Byrnes↗

Environmental Testing of the NEXT PM1R Ion Engine

The NEXT propulsion system is an advanced ion propulsion system presently under development that is oriented towards robotic exploration of the solar system using solar electric power. The subsystem includes an ion engine, power processing unit, feed system components, and thruster gimbal. The Prototype Model engine PM1 was subjected to qualification-level environmental testing in 2006 to demonstrate compatibility with environments representative of anticipated mission requirements. Although the testing was largely successful, several issues were identified including the fragmentation of potting cement on the discharge and neutralizer cathode heater terminations during vibration which led to abbreviated thermal testing, and generation of particulate contamination from manufacturing processes and engine materials. The engine was reworked to address most of these findings, renamed PM1R, and the environmental test sequence was repeated. Thruster functional testing was performed before and after the vibration and thermal-vacuum tests. Random vibration testing, conducted with the thruster mated to the breadboard gimbal, was executed at 10.0 Grms for 2 min in each of three axes. Thermal-vacuum testing included three thermal cycles from 120 to 215 C with hot engine re-starts. Thruster performance was nominal throughout the test program, with minor variations in a few engine operating parameters likely caused by facility effects. There were no significant changes in engine performance as characterized by engine operating parameters, ion optics performance measurements, and beam current density measurements, indicating no significant changes to the hardware as a result of the environmental testing. The NEXT PM1R engine and the breadboard gimbal were found to be well-designed against environmental requirements based on the results reported herein. The redesigned cathode heater terminations successfully survived the vibration environments. Based on the results of this test program and confidence in the engineering solutions available for the remaining findings of the first test program, specifically the particulate contamination, the hardware environmental qualification program can proceed with confidence

Snyder, John S.↗