Thermal Control Materials on MISSE-6 with Comparison to Earlier Flight Data

This slide presentation reviews the results of exposing thermal control materials as studied during Materials International Space Station Experiment-6 (MISSE-6). It discusses the location of the materials, and the type of environmental exposure. It then reviews the effect on the various types of coatings, showing the results with graphs and photos of the samples after the experimental exposure to the low earth orbital environment for comparison with the control sample and with earlier flights.

Finckenor, Miria M.

The International Space Station (ISS) Port 1 (P1) External Active Thermal Control System (EATCS) Ammonia Leak

Ammonia is used in the Starboard 1 (S1) and Port 1 (P1) External Active Thermal Control System (EATCS) to cool the pressurized modules, and some of the external electrical power distribution hardware. Leaks that develop in these critical cooling systems that deplete in-line tanks can ultimately result in loss of cooling, which can have devastating impacts to the mission, science and crew onboard the ISS. A slow ammonia leak was initially observed from the P1 EATCS in 2011, but later in 2013 the leak rate began to accelerate. The ammonia inventory eventually began to decay exponentially, raising concerns that the inventory could drop to levels where the system would not be operational.The Robotic External Leak Locator (RELL) was built and launched to the ISS to detect and help locate ammonia leaks using the ISS Robotic Arm and remote ground operator control without constant crew involvement. RELL pinpointed the ammonia leak to the two flexible jumper hose assemblies connecting one of two fluid loops in one of the three deployable radiators to the P1 EATCS. The ammonia inside the two hose assemblies and that radiator fluid loop was isolated and vented to space in 2017. This stopped the leak and an Extravehicular Activity was conducted to remove the two hose assemblies so they could be returned to ground for further Test, Teardown and Evaluation (TT&E). The purpose of this presentation is to discuss this leakage scenario and the TT&E efforts.

Cowan, Darnell T.

University role in astronaut life support systems: Portable thermal control systems

One of the most vital life support systems is that used to provide the astronaut with an adequate thermal environment. State-of-the-art techniques are reviewed for collecting and rejecting excess heat loads from the suited astronaut. Emphasis is placed on problem areas which exist and which may be suitable topics for university research. Areas covered include thermal control requirements and restrictions, methods of heat absorption and rejection or storage, and comparison between existing methods and possible future techniques.

Ephrath, A. R.

Space shuttle environmental and thermal control life support system computer program

A computer program for the design and operation of the space shuttle environmental and thermal control life support system is presented. The subjects discussed are: (1) basic optimization program, (2) off design performance, (3) radiator/evaporator expendable usage, (4) component weights, and (5) computer program operating procedures.

Source record

Space tug thermal control

It was determined that space tug will require the capability to perform its mission within a broad range of thermal environments with currently planned mission durations of up to seven days, so an investigation was conducted to define a thermal design for the forward and intertank compartments and fuel cell heat rejection system that satisfies tug requirements for low inclination geosynchronous deploy and retrieve missions. Passive concepts were demonstrated analytically for both the forward and intertank compartments, and a worst case external heating environment was determined for use during the study. The thermal control system specifications and designs which resulted from the research are shown.

Source record

Radiation Induced Degradation of the White Thermal Control Paints Z-93 and Z-93P

This paper details a comparison analysis of the zinc oxide pigmented white thermal control paints Z-93 and Z-93P. Both paints were simultaneously exposed to combined space environmental effects and analyzed using an in-vacuo reflectance technique. The dose applied to the paints was approximately equivalent to 5 years in a geosynchronous orbit. This comparison analysis showed that Z-93P is an acceptable substitute for Z-93. Irradiated samples of Z-93 and Z-93P were subjected to additional exposures of ultraviolet (UV) radiation and analyzed using the in-vacuo reflectance technique to investigate UV activated reflectance recovery. Both samples showed minimal UV activated reflectance recovery after an additional 190 equivalent sun hour (ESH) exposure. Reflectance response utilizing nitrogen as a repressurizing gas instead of air was also investigated. This investigation found the rates of reflectance recovery when repressurized with nitrogen are slower than when repressurized with air.

Edwards, D. L.

CO2 Insulation for Thermal Control of the Mars Science Laboratory

The National Aeronautics and Space Administration (NASA) is sending a large (>850 kg) rover as part of the Mars Science Laboratory (MSL) mission to Mars in 2011. The rover's primary power source is a Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) that generates roughly 2000 W of heat, which is converted to approximately 110 W of electrical power for use by the rover electronics, science instruments, and mechanism-actuators. The large rover size and extreme thermal environments (cold and hot) for which the rover is designed for led to a sophisticated thermal control system to keep it within allowable temperature limits. The pre-existing Martian atmosphere of low thermal conductivity CO2 gas (8 Torr) is used to thermally protect the rover and its components from the extremely cold Martian environment (temperatures as low as -130 deg C). Conventional vacuum based insulation like Multi Layer Insulation (MLI) is not effective in a gaseous atmosphere, so engineered gaps between the warm rover internal components and the cold rover external structure were employed to implement this thermal isolation. Large gaps would lead to more thermal isolation, but would also require more of the precious volume available within the rover. Therefore, a balance of the degree of thermal isolation achieved vs. the volume of rover utilized is required to reach an acceptable design. The temperature differences between the controlled components and the rover structure vary from location to location so each gap has to be evaluated on a case-by-case basis to arrive at an optimal thickness. For every configuration and temperature difference, there is a critical thickness below which the heat transfer mechanism is dominated by simple gaseous thermal conduction. For larger gaps, the mechanism is dominated by natural convection. In general, convection leads to a poorer level of thermal isolation as compared to conduction. All these considerations play important roles in the optimization process. A three-step process was utilized to design this insulation. The first step is to come up with a simple, textbook based, closed-form equation assessment of gap thickness vs. resultant thermal isolation achieved. The second step is a more sophisticated numerical assessment using Computational Fluid Dynamics (CFD) software to investigate the effect of complicated geometries and temperature contours along them to arrive at the effective thermal isolation in a CO2 atmosphere. The third step is to test samples of representative geometries in a CO2 filled chamber to measure the thermal isolation achieved. The results of these assessments along with the consistency checks across these methods leads to the formulation of design-guidelines for gap implementation within the rover geometry. Finally, based on the geometric and functional constraints within the real rover system, a detailed design that accommodates all these factors is arrived at. This paper will describe in detail this entire process, the results of these assessments and the final design that was implemented.

CO2

Development of a thermal control coating for space suits

Past space suits and the current Shuttle suit, which are constructed primarily from fabric, use the Integrated Thermal and Micrometeoroid Garment, which insulates the astronaut from his environment. The new generation of hard suits affords designers the opportunity to incorporate thermal control into the suit structure. Environmental influence on the suit temperature and heat flux can then be minimized with a high reflectance coating. Candidate coatings have been identified and ranked on the basis of thermophysical properties; wear, corrosion and atomic oxygen degradation resistance; and coating process and cost. Laboratory determination of properties, thermal cycling and wear resistance tests are underway to identify the optimum coating. A computer model is being developed to evaluate various environmental configurations. Preliminary results are presented here.

Squire, Bernadette

Optical properties of thermal control coatings contaminated by MMH/N2O4 5-pound thruster in a vacuum environment with solar simulation.

Cat-a-lac Black and S13G thermal control coatings were exposed to the exhaust of a thrustor in a simulated space environment. Vacuum was maintained at less than 10 microtorr during thrustor firing in the liquid helium cooled facility. The thrustor was fired in a 50-millisecond pulse mode, and the accumulated firing time was 224 seconds. Solar absorptance and thermal emittance of the coatings were measured in-situ at intervals of 300 pulses, using a calorimetric technique. The Cat-a-lac Black coatings showed no change in solar absorptance or thermal emittance. The S13G showed up to 25% increase in solar absorptance but no change in thermal emittance.

Sommers, R. D.

Verification of an analytic modeler for capillary pump loop thermal control systems

A number of computer programs have been written to model two-phase heat transfer systems for space use. These programs support the design of thermal control systems and provide a method of predicting their performance in the wide range of thermal environments of space. Predicting the performance of one such system known as the capillary pump loop (CPL) is the intent of the CPL Modeler. By modeling two developed CPL systems and comparing the results with actual test data, the CPL Modeler has proven useful in simulating CPL operation. Results of the modeling effort are discussed, together with plans for refinements to the modeler.

Schweickart, R. B.

MEMS device for spacecraft thermal control applications

A micro-electromechanical device that comprises miniaturized mechanical louvers, referred to as Micro Electro-Mechanical Systems (MEMS) louvers are employed to achieve a thermal control function for spacecraft and instruments. The MEMS louvers are another form of a variable emittance control coating and employ micro-electromechanical technology. In a function similar to traditional, macroscopic thermal louvers, the MEMS louvers of the present invention change the emissivity of a surface. With the MEMS louvers, as with the traditional macroscopic louvers, a mechanical vane or window is opened and closed to allow an alterable radiative view to space.

Swanson, Theordore D.

Optical properties of thermal control coating contaminated by MMH/N2O4 5-pound thruster in a vacuum environment with solar simulation

Cat-a-lac Black, and S13G thermal control coatings were exposed to the exhaust of a thruster in a simulated space environment. Vacuum was maintained at less than 10 to the minus 5th power torr during thruster firing in the liquid helium cooled facility. The thruster was fired in a 50-millisecond pulse mode and the accumulated firing time was 224 seconds. Solar absorptance (alpha sub s) and thermal emittance (sigma) of the coatings were measured in-situ at intervals of 300 pulses. A calorimetric technique was used to measure alpha sub s and sigma. The tests, technique, and test results are presented. The Cat-a-lac Black coatings showed no change in alpha sub s or sigma. The S13G showed up to 25 percent increase in alpha sub s but no change in sigma.

Sommers, R. D.