At least 595 records · Page 33

Accelerated Creep Testing of Inconel 718 Using the Stepped Isostress Method (SSM)

This paper demonstrates the stepped isostress method (SSM); an accelerated creep test (ACT) for the rapid assessment of metallic materials. The SSM test is based on the time-temperature-stress superposition principle (TTSSP) where temperature and/or stress are step increased to accelerate the time-to-rupture. The SSM test has proven successful for the ACT of polymers and polymeric composites but has yet to be proven for metallic materials. In this study, new test matrix design rules for the SSM of metals are established based on deformation mechanism, time-temperature transformation, and time-temperature precipitation maps. A test matrix of SSM and conventional creep tests (CCTs) are executed for alloy Inconel 718 at 750°C (1382°F) with stress levels ranging from 100 to 350 MPa. Validation CCT data is gathered from the Japan National Institute of Material Science (NIMS). Material constants for the Sine-hyperbolic (Sinh) constitutive model are calibrated using the SSM data and employed to predict the conventional creep response. Here, when blindly compared to the CCT data, the SSM calibrated Sinh model can accurately predict the conventional creep response across logarithmic decades and thus accelerate the capture of conventional creep data. Fractography indicates ductile fracture by transgranular microvoid coalescence (TMVC) with the same fracture mode observed in both SSM and CCT specimens. Creep cavitation is indicated by the population, smoothness, and size of microvoids.

36 MATERIALS SCIENCE↗

Tidal Turbine Test, Downeast Turbines, July 12, 2021

Downeast Turbines tested a tidal turbine prototype with novel rotor/channel system and lateral effluent discharge apparatus (LEDA), during five days of testing in the flume at Alden Lab. Three days of testing (July 12-14, 2021) focused on turbine power metrics of torque and rpm, which were low, and then two days of follow-up testing (July 27-28, 2021) focused on LEDA performance metrics of pressure differential and rates of volumetric flow, with encouraging results. Next step is to to characterize, and even optimize, configurations of the LEDA, using 3D-CFD as a helpful tool, to refine its shape and explore its limits of performance as a means of effluent discharge that augments performance of an instream turbine. An improved configuration of the LEDA will be re-combined with the rotor/channel system of the turbine prototype, and ultimately, the rotor will be re-sized (enlarged), to better match the LEDA's performance capabilities in drawing through a rate of volumetric flow. This submission is Downeast Turbines' Post Access Report for the test event. It includes the files described here (next below), and several reference links. "Downeast TEAMER-Post-Access-Report...docx" is a document file containing the report. "Appendices A, B, and C" are included in this file, and so are "Figures #1-7." "Appendix D - Test Data Workbooks.zip" is an archive file containing all post access data (raw data tables, calculating tables, and graphs), presented in fourteen Excel workbooks as described in the report. "Appendix E - Post Access Figures.zip" is an archive file containing "Figures #8-52," of the report.

16 TIDAL AND WAVE POWER↗

Bench Testing Data and Report for an Early Prototype Pitch Resonator WEC

This dataset encompasses data and documentation from bench tests conducted on an early prototype of a "pitch resonator" wave energy converter (WEC). The testing aimed to validate numerical models and reduce risks associated with the pitch resonator concept, which is designed to convert the pitching and rolling motions of a buoy into electrical power. The project's goal is to provide supplementary power, in the range of 10-100 watts, to the National Science Foundation's Ocean Observatories Initiative Pioneer Array. Two distinct testing phases are documented: one using a single degree of freedom (1DOF) test rig, and another employing a six degree of freedom (6DOF) Stewart platform, known as the Large Amplitude Motion Platform (LAMP). These tests assessed various factors, such as system performance in different motion scenarios, the torque exerted by wave forces, and the impact of mounting configurations. The dataset includes raw test data in MATLAB (.mat) format, detailed metadata, and a report describing the experimental procedures and preliminary findings.

16 TIDAL AND WAVE POWER↗

An Accelerated Creep Testing (ACT) Program for Advanced Creep Resistant Alloys for High Temperature Fossil Energy (FE) Applications (Final Report)

The research objective of this study is to develop an accelerated creep testing (ACT) program for advanced creep resistant alloys for high temperature FE applications. This research produced a new ACT for metallic materials based on Time-Temperature-Stress Superposition (TTSSP). In TTSSP, there exists a fundamental relationship between creep resistance, time, temperature, and stress that can be manipulated to reduce test durations. In our study, the stepped isostress method was employed where step increases of load during creep testing accelerated the time-to-rupture. Well-posed constitutive models including sin-hyperbolic and Wilshire-Cano-Stewart where calibrated using the SSM data and employed to predict the conventional creep response of the material. In our best experiments, <100-hour tests on lnconel 718 at 750 deg C produced over a 64x acceleration of data when compared to conventional data from Japan's National Institute of Materials Science. The ACTs enable the rapid screening of candidate materials, where a small test matrix of short duration tests can be employed to determine the creep resistance (minimum-creep-strain-rate, stress-rupture, and creep deformation) of a material across decades.

20 FOSSIL-FUELED POWER PLANTS↗

Nodal Capacity Expansion Modeling with ReEDS: A Case Study of the RTS-GMLC Test System

Test systems play an important role in power systems analysis and are used extensively for a wide range of purposes like reliability analysis, production cost modeling, studying the impacts of load shifting, and many more. These test systems have continued to evolve over the years to keep pace with changing system compositions due to technology and policy changes. In this work, we apply the Regional Energy Deployment System (ReEDS) model, a large-scale capacity expansion model (CEM), on the nodal RTS-GMLC system to perform capacity expansion of the bus-level test system. This work both demonstrates that a large-scale CEM can successfully be applied to nodal systems, and that the CEM can allow a test system to be evolved to meet desired criteria. The process allowed the coupling of CEM data not available in the test system (such as capital costs) with test system data to provide plausible system evolutions in line with scenario specifications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling of HTTF test PG-26 using RELAP5-3D and SAM

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors (HTGR) with prismatic fuel and reflector blocks [1]. Several tests have been completed at the HTTF including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This summary reports on the analysis of test PG-26 using the INL system code REALP5-3D [2] as well as the ANL system code SAM [3]. Test PG-26 is a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC [4]. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heater banks. The DCC transient was initiated during the 50th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test.

97 MATHEMATICS AND COMPUTING↗

Development of Mission Profiles for Humidity Models in the Reliability Testing of PV Inverters: Preprint

To understand the impacts of humidity on PV inverters, mission profiles were developed to accurately describe the different processes and rates based on the environmental factors of temperature, relative humidity, and irradiance. The operating environment of the device introduces stress factors dependent on component temperature, relative humidity, and component voltage. The development of profiles started from looking at historical climate conditions at Cocoa, Florida, a hot and humid location. The profile developed from field location was compared with existing humidity test profiles in industrial and military standards to determine acceleration factors. Prior to the evaluation of the mission profiles, critical components in the PV inverter were identified based on vendor discussions along with failure modes of interest. The profiles considered in this study was demonstrated using a 4-kVA string inverter. The measurements from the devices were substituted in device manufacturer specified equation to determine the severity of each test. The severity of each test was compared against the severity of the 24-hour result to determine the acceleration factor of each test. The acceleration factors were determined to be over a range of 1.2-6 for the existing humidity tests from standards, when compared against the mission profile developed from field data. This optimal humidity/thermal profile will be passed to the IEC standards development for inverter qualification testing.

humidity models↗

Dynamic System Scaling Application to Accelerated Nuclear Fuel Testing

The development of nuclear fuel and materials requires a continuous effort to investigate the acute and prolonged effects of irradiation, thermal-material stress, chemical change, or other conceivable damage mechanics acquired during normal operation or accident scenarios throughout its lifetime. As in-core fuel property measurement techniques advance to support in the real-time, non-invasive, and enhanced accuracy realm, it is the future of fuel development to pursue to higher degrees of control, predictability of integral test behavior via separate effects test (SET), and shorter test time intervals. The fuel development life cycle from initial concept to commercial licensing is approximated to be 20 years and current literature suggests by optimizing fuel performance codes with SETs, the process could possibly be compressed to 5 to 10 years. Recently, a research group in the Idaho National Laboratory (INL) is testing reduced scale fuel rods and increased power density to accelerate evolution of fuel phenomena in metallic fuels. In support of nuclear fuel rod development, compressing fuel test process, and accelerating fuel phenomena, it was the purpose of this study to investigate nuclear fuel performance phenomena via literature review and effectively scale the initial conditions, boundary conditions, and geometric properties to describe the time-dependent response including to fuel burnup, thermal and mechanical stress, transmutations and inter-diffusion, and other relevant observed phenomena. The study was based on BISON simulations of historic EBR-II metallic fuel experiments and Dynamical System Scaling (DSS) method are utilized to assess effects of scaling activity including fuel phenomena acceleration and calculations of time-dependent distortions. The research successfully scaled metallic fuel phenomena, accelerated fuel testing, and assessed the distortions for each scaled case derived.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-Cell Thermal Creep Frame Capability: Out-of-Cell Construction and Subsized Sample Testing

This report describes the activities related to the construction of an in-cell thermal creep test facility for small-scale specimens in the irradiation-assisted stress-corrosion cracking (IASCC) hotcell located at the Fuels and Applied Science Building (FASB) at INL. The whole project includes three stages: (i) conceptual design; (ii) out-of-cell demonstration tests; and (iii) in-cell demonstration testing. During the current fiscal year (FY)-2022, materials and equipment required to construct the conceptual design outlined in a previous report were procured. Frames for conducting out-of-cell testing have been constructed, and testing plans have been developed to assess the operation of the newly constructed frames. Preliminary testing of flat subsized tensile specimens on ASTM creep frames has also been completed for two sample thicknesses: 0.75 mm and 1.0 mm.

36 MATERIALS SCIENCE↗

Initial Testing of Alkaline Earth Metal Ion Absorption on Crystalline Silicotitanate - 20440

The Tank Closure Cesium Removal process at the Savannah River Site (SRS) has processed aqueous tank waste using the inorganic ion exchange media IONSIV{sup TM} R9120-Ba (which is also known as Crystalline Silicotitanate (CST)). Salt-cake in Tank 10H at SRS was dissolved and processed through filters and ion exchange columns. The primary purpose of the process is to remove Cs-137 from the aqueous waste so that it can be disposed as low level waste. It is known that this inorganic media also absorbs strontium from solution, and that strontium competes with cesium ions for absorption sites. The strontium ion is actually more strongly absorbed than the cesium ion from typical tank waste. However, strontium is typically present in low concentrations so does not normally cause a significant impact. Strontium is present as both non-radioactive isotopes and the radioactive Sr-90 isotope; with the non-radioactive isotopes being much more abundant. Although the total strontium solubility is usually much lower than cesium, some tank waste compositions can have a high enough soluble strontium concentration to decrease the cesium absorption. Relatedly, some testing at SRS suggested that another alkaline earth metal, calcium, may also absorb onto CST and may decrease cesium absorption. Barium is also an important species in treatment of tank waste, but is also usually present at low concentrations. However, after the Cs-137 is absorbed onto CST, it emits a beta particle and converts to Ba-137m, which then decays to non-radioactive Ba-137 by emission of a gamma ray. If the Ba-137m were to desorb quickly, it could impact the dose rate in down-stream equipment. In order to understand the impact of these alkaline earth metals on CST, SRNL performed testing using simulants of SRS tank waste that contain soluble barium, strontium, and calcium. Testing examined both removal of the alkaline earth metals and their impact on removal of cesium. Testing involved first developing realistic waste simulant formulations and dissolving the alkaline earth metals to high enough concentrations to potentially impact the Cs absorption. Once the formulations were developed and prepared, computer modeling was used to calculate the expected Cs absorption behavior to determine if the alkaline earth metals impact the performance. Measurements of the alkaline earth metals absorption by the media is also important for disposition of spent media because of the added radionuclide inventory from the Sr-90. These initial tests are examining the general impact and will be used to determine if further testing or measurements are needed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of a Soil Flushing Treatability Test for Hanford Site Hexavalent Chromium Removal - 20446

U.S. Department of Energy contractor CH2M Hill Plateau Remediation Company has made significant progress remediating hexavalent chromium in groundwater near the Columbia River through the operation of pump and treat facilities and source removal activities. To mitigate risks associated with hexavalent chromium contamination, which was identified in a CERCLA interim action record of decision as the primary groundwater contaminant of concern for the 100-KR-4 Operable Unit from discharging to the Columbia River, three ion-exchange pump and treat systems were installed between 1997 and 2009. Between 2010 and 2016, operation of the K West pump and treat system, located near the former 105K West plutonium production reactor, reduced concentrations below the groundwater remediation target for hexavalent chromium. In 2016, a rebound study was performed to evaluate the effectiveness of the pump and treat remedy and assess the potential for any residual hexavalent chromium sources continuing to contribute to groundwater contamination. As a result of the rebound study, a source of continued groundwater contamination was identified. To address this condition, a soil flushing treatability test was written and approved by the U.S. Department of Energy and the U.S. Environmental Protection Agency. The test included saturating about a 1-acre area of soil with treated water with the goal of forcing the residual hexavalent chromium to groundwater where existing extraction wells could remove it for treatment, accelerating the cleanup process. In spring and summer 2019, CH2M Hill Plateau Remediation Company installed and began operating a shallow underground leach system to support the treatability test. Preliminary sampling data show the test was effective in removing the residual contamination. Following further evaluation and analysis from the initial test, the process will be considered for implementation elsewhere on the Hanford Site, particularly at locations where there is a known or suspected continuing contamination source in the soil column. The paper will cover the goals of the study, as well as more details about the following: - Overview of pump and treat exit strategy (using U.S. Environmental Protection Agency guidance); - The design and installation of the soil flushing technology in the 100-K Area; - The testing process and results of sampling data; - Post-study evaluation and potential for implementation in other locations at the Hanford Site. Innovative solutions for cleanup, such as the soil flushing technology, have resulted in substantial progress in the removal of groundwater contaminants at the Hanford Site, potentially shortening the time frame required to meet cleanup goals and resulting in significant cost savings. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Local Power Impact Experiment Design for a New Fuel Type for use in the Advanced Test Reactor

The Advanced Test Reactor (ATR), and complimentary zero-power ATR Critical (ATRC) reactor, located at Idaho National Labs (INL), are undergoing conversion from Highly Enriched Uranium (HEU) to Low Enriched Uranium (LEU). Both have a variety of testing locations that can receive large variations in flux due to its unique serpentine design, consisting of five lobes (see Figure 1). Initial criticality and power distribution throughout the core are controlled by core-external outer shim control cylinders (OSCCs). Distinct test loops allow for testing at specific temperatures, pressures, and irradiation conditions. The ATR is one of the key nuclear engineering research and testing facilities within the DOE National Laboratory Complex, and the ATRC supports its operation [1]. Currently, the Office of Material Management and Minimization (M3) within the National Nuclear Security Administration of the DOE is working to convert the remaining research reactors, including the ATR, from 93% HEU fuel to 19.75% LEU fuel (LEU) to support non-proliferation [2]. Extensive materials testing at INL and internationally has demonstrated that a high-density uranium molybdenum (U 10Mo) alloy can meet the performance requirements of the remaining high powered research reactors. However, there are many technical challenges to address before the conversion to LEU can be successful, including the accurate characterization of the reactor core physics with LEU fuel. Reactor physics safety evaluations currently use Monte Carlo for the 21st Century (MC21), a continuous-energy Monte Carlo radiation transport code [3]. Existing MC21 models of the ATR and ATRC cores have a validation basis for use in neutronics analyses with HEU fuel. The models are used to support safety analyses that include comparisons to the safety requirements for the reactors. However, the use of the LOWE element in the ATR and ATRC is not currently covered by the current model validation basis. To deploy the new fuel type, extensive computational reactor physics support is necessary to support the use of LOWE in the ATR and ATRC. Therefore, LOWE requires a rigorous validation basis, aligned with that of HEU fuel, that takes advantage of the existing software tools and processes currently used for the ATR and ATRC. The experiment to validate of the MC21 models for determining power, the Power Impact Validation Experiment, will consist of two flux runs in the ATRC, one with fully HEU loading and one with a single LOWE element. Both flux runs will be instrumented with 20 sets of azimuthal fission wires and 3 sets of axial fission wires, as shown in Figure 4. Standard flux run methodology will be used [4]. Power Impact Validation Experiment data will be compared against MC21 calculated data, both for absolute fission rate accuracy and to determine the relative change in fission rates between the two runs. The results of the Power Impact Validation Experiment and subsequent evaluations will provide the validation basis for MC21 for use with LOWE elements. Key features of the Power Impact Validation Experiment include: (1) Two flux runs to allow for LOWE perturbed measurements to be compared to already validated measurements taken from a full core of HEU fuel, (2) Optimization of instrumentation to balance analytical needs with practical considerations (e.g., limited time window to count beta particles from fission products), and (3) Standard ATRC core loading, including both driver positions and flux traps, to minimize cost while remaining representative of typical ATR core loading.

42 ENGINEERING↗

Laboratory Evaluation of Commercial Utility Microgrid Controller Test Results

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) distributed energy resources (DER). In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. This second edition update also includes results from applying the tests to a commercial utility microgrid controller. These results evaluate the performance and reliability of the controller under various operational scenarios. It identifies specific areas where the controller excels and highlights gaps that need to be addressed for future enhancements. The application of these test plans on real-world system behavior provides insights on commercial equipment readiness for field deployment. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MODEL DEVELOPMENT AND VERIFICATION OF A 1,350°C AIR RECEIVER TEST SYSTEM

Open-loop volumetric receivers work with air at atmospheric pressure and are suitable for single-cycle or multicycle power plants. A novel additively manufactured (AM) silicon carbide (SiC), ceramic matrix composite (CMC) volumetric receiver was developed that consisted of a lattice structure, which absorbs solar radiation and converts it into heat energy. Heat energy from the porous receiver was transferred to heated ambient air. The receiver acted as a convective heat exchanger, transferring heat to the fluid through convection. Engineering was facilitated to develop a high-temperature air receiver test bed at Sandia national Laboratories (SNL) capable of demonstrating a 50kWth open-loop volumetric SiC air receiver module developed by General Electric Aerospace Research (GE Aerospace). This paper presents the development of the high temperature AM SiC-CMC air receiver, the test bed, and the first testing operations of this device, which was experimentally demonstrated to achieve 1,350°C for over 3.5 hours of operation, based on input flux levels of 67–91 W/cm2 0.5-2.5 kg/s flow rates. From the test campaign results, based on the measured convective heat transfer to the airflow and bounded radiative-loss assumptions, the solar-thermal efficiency of HOTSSTAR test module was estimated to be approximately as high as 74% for representative test conditions.

14 SOLAR ENERGY↗

Transient testing of uranium silicide fuel in zircaloy and silicon carbide cladding

Using the newly restarted Transient Reactor Test (TREAT) facility at Idaho National Laboratories, fresh (unirradiated) U 3 Si 2 fuel pellets were tested under reactivity-initiated accident conditions in dry helium capsules. These tests were performed with total energy depositions sufficient to induce melting of the U 3 Si 2 fuel pellets based on available thermophysical property data. The instrumented experiments utilized in-pile thermocouples and infrared pyrometers to measure the cladding temperature during the transient, which are in reasonable agreement with predicted peak cladding temperatures using a simple BISON fuel performance model. This same model is then used to predict expected cladding stresses during the transients in areas where pellet cladding interaction is expected. It was shown that for transient energy depositions up to 528J/g rod like geometry of the test articles was maintained. While it is acknowledged that more confirmatory testing is required in more prototypic environments, these first of their kind experiments have demonstrated that unirradiated U 3 Si 2 fuel and unirradiated SiC-SiC claddings can likely retain a “rod like” geometry for transient energy depositions up to 528J/g.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development and testing of a performance evaluation methodology to assess the reliability of occupancy sensor systems in residential buildings

With the emergence of advanced occupancy sensor technologies to better detect occupancy in buildings, a universal methodology and metrics are required to evaluate and report sensor systems’ reliability and compare the performance across multiple sensor systems. Herein this research presents a methodology to assess the reliability of occupancy sensor systems in residential buildings in a controlled laboratory environment, including both “typical” and “failure” testing scenarios. The developed methodology was then implemented to evaluate a novel occupancy detection sensor system’s reliability. “Typical” testing evaluates the overall accuracy of the sensor system, which suggest how reliable the occupancy sensor system is over time. Results show that on average, the precision and recall are 0.75 and 0.70, indicating similar numbers of false positives and false negatives across the dataset. The overall accuracy of the tested sensor system was 62.4% to 76.4%. Failure testing results indicate whether there are influential variables impacting the sensor performance. For the tested sensor system, the number of occupants, presence of large objects, presence of interior light sources, and number of doors are not influential, while lighting level, location of occupants, additional door in the entry/exit area, and having the TV on are variables determined to impact the sensor system performance.

47 OTHER INSTRUMENTATION↗

Accelerated reliability tests of n + and p + poly-Si passivated contacts

We report on the stability of encapsulated, low-pressure chemical vapor-deposited phosphorus (n + poly-Si) doped and boron (p + poly-Si) doped poly-Si/SiO x passivated contacts by exposing the samples to three different accelerated tests: damp heat test, thermal cycling and ultraviolet exposure, adhering closely to the IEC 61215 standard. Outdoor testing was also performed by exposing the samples in the outdoor testing field at the National Renewable Energy Laboratory, and preliminary data accumulated for 1000 h from February to April of 2021 is reported. We studied non-metallized, thermally-metallized, and screen-printed n + and p + poly-Si by monitoring the effective minority carrier lifetime at the implied maximum power point using a Sinton lifetime tester, and recorded photoluminescence images before and after the exposure. Furthermore, the samples were found to be stable under all test conditions, which is encouraging for incorporation of these contacts in next-generation industrial silicon solar cells.

14 SOLAR ENERGY↗

Lost Circulation Materials in Geothermal Drilling: Thermal Degradation, Viscosity, Compression, and Flow Loop Tests

This dataset provides a set of experimental data on the performance of lost circulation materials (LCMs) used in geothermal drilling operations. It includes results from four distinct tests: thermal degradation, viscosity measurements, compression tests, and high-temperature flow loop experiments. The materials tested, such as cedar fiber, cotton seed hulls, magma fiber, microcellulose, and sawdust, were analyzed under a range of conditions to assess their effectiveness in mitigating fluid losses in geothermal wells. Data on thermal degradation explores mass loss, water loss, and gas release for each material when subjected to temperatures between 90C and 250C. Viscosity measurements capture the behavior of LCM mixtures under different temperatures, while compression tests investigate the structural integrity of both undegraded and thermally degraded materials. The high-temperature flow loop experiments simulate geothermal well conditions, analyzing how different materials and mixtures affect fluid flow and sealing performance in a fractured reservoir environment. In addition to the experimental data, the dataset includes photos documenting the materials, schematics of test setups, and several published manuscripts that provide detailed insights into the experimental methods and findings.