Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature modelling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Computational Fluid Dynamics Modeling of Low Temperature Ignition Processes From a Nanosecond Pulsed Discharge at Quiescent Conditions

Recent interest in nonequilibrium plasma discharges as sources of ignition for the automotive industry has not yet been accompanied by the availability of dedicated models to perform this task in computational fluid dynamics (CFD) engine simulations. The need for a low-temperature plasma (LTP) ignition model has motivated much work in simulating these discharges from first principles. Most ignition models assume that an equilibrium plasma comprises the bulk of discharge kernels. LTP discharges, however, exhibit highly nonequilibrium behavior. In this work, a method to determine a consistent initialization of LTP discharge kernels for use in engine CFD codes like CONVERGE is proposed. The method utilizes first principles discharge simulations. Such an LTP kernel is introduced in a flammable mixture of air and fuel, and the subsequent plasma expansion and ignition simulation is carried out using a reacting flow solver with detailed chemistry. Finally, the proposed numerical approach is shown to produce results that agree with experimental observations regarding the ignitability of methane-air and ethylene-air mixtures by LTP discharges.

33 ADVANCED PROPULSION SYSTEMS↗

Stochastic mean-field theory: Method and application to the disordered Bose-Hubbard model at finite temperature and speckle disorder

We discuss the stochastic mean-field theory (SMFT) method, which is a new approach for describing disordered Bose systems in the thermodynamic limit including localization and dimensional effects. We explicate the method in detail and apply it to the disordered Bose-Hubbard model at finite temperature, with on-site box disorder, as well as experimentally relevant unbounded speckle disorder. We find that disorder-induced condensation and re-entrant behavior at constant filling are only possible at low temperatures, beyond the reach of current experiments [M. Pasienski, D. McKay, M. White, and B. DeMarco, e-print arXiv:0908.1182]. Including off-diagonal hopping disorder as well, we investigate its effect on the phase diagram in addition to pure on-site disorder. To make connection to present experiments on a quantitative level, we also combine SMFT with an LDA approach and obtain the condensate fraction in the presence of an external trapping potential.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A DATA-DRIVEN, TWO-TEMPERATURE SOLAR WIND MODEL WITH ALFVEN WAVES

We have developed a new three-dimensional magnetohydrodynamic (MHD) solar wind model coupled to the Space Weather Modeling Framework (SWMF) that solves for the different electron and proton temperatures. The collisions between the electrons and protons are taken into account as well as the anisotropic thermal heat conduction of the electrons. The solar wind is assumed to be accelerated by the Alfven waves. In this paper, we do not consider the heating of closed magnetic loops and helmet streamers but do address the heating of the protons by the Kolmogorov dissipation of the Alfven waves in open field-line regions. The inner boundary conditions for this solar wind model are obtained from observations and an empirical model. The Wang-Sheeley-Arge model is used to determine the Alfven wave energy density at the inner boundary. The electron density and temperature at the inner boundary are obtained from the differential emission measure tomography applied to the extreme-ultraviolet images of the STEREO A and B spacecraft. This new solar wind model is validated for solar minimum Carrington rotation 2077 (2008 November 20 through December 17). Due to the very low activity during this rotation, this time period is suitable for comparing the simulated corotating interaction regions (CIRs) with in situ ACE/WIND data. Although we do not capture all MHD variables perfectly, we do find that the time of occurrence and the density of CIRs are better predicted than by our previous semi-empirical wind model in the SWMF that was based on a spatially reduced adiabatic index to account for the plasma heating.

79 ASTRONOMY AND ASTROPHYSICS↗

The Quasi-Biennial Oscillation in Model-Simulated and Observed Equatorial Temperature of the Lower Stratosphere

In an otherwise thorough survey of metrics for models that simulate the Quasi-Biennial Oscillation, Schenzinger et al. say “there is no comparable observational dataset” to compare with model-simulated stratospheric temperatures (Geosci. Model Dev. 10, 2157-2168, 2017). They compare model temperatures only with reanalysis datasets, which come from numerical weather prediction models and therefore are not direct observations. But stratospheric brightness temperatures have been directly observed by microwave radiometers on board a series of satellites since 1979. Christy and Drouilhet (J. Climate 7, 106-120, 1994) found a QBO signal in 1979-1992 data from the Microwave Sounding Unit’s lower stratospheric Channel 4 (with peak weighting function at the 75hPa pressure level and half-power values at 120 and 40hPa, about 20±5 km altitude). To detect the QBO signal, Christy and Drouilhet used a latitude weighting that matches the QBO’s anti-correlation between the Equator and ±15°. Fernandez et al. also found a QBO signal in 1979-2000 MSU data, using EOF analysis (J. Climate 17, 3934-3946, 2004). Recently, Christy and Covey extended Christy and Drouilhet’s analysis through 2017 (“Stratospheric Temperature,” Section 2b5 in State of the Climate in 2017. Bull. Amer. Meteor. Soc. 99, S150–S152; Figure 2.10c). The QBO signal was again clearly visible. Although temperature trends for the lower atmosphere are sensitive to inter-satellite calibration and other processing details, giving rise to some controversy, data for the lower stratosphere are more robust. Christy and Covey’s Figure 2.9 shows that data processed separately by the National Oceanic and Atmospheric Administration (NOAA) and by Remote Sensing Systems (RSS) gives a QBO index that is virtually identical to that of Christy’s group at the University of Alabama at Huntsville (UAH).

58 GEOSCIENCES↗

Nuclear matter properties in the non-linear Walecka model at finite temperature with interaction between the σ - ω mesons

In this work in contrast to the usual Walecka model [1] we include the interaction between the σ – ω mesons [2,3] with the aim of studying the nuclear matter properties in the relativistic mean-field theory in the regime of high temperatures. Therefore in our work we use the non-linear Walecka model. We investigate whether the phase transition characteristic of other models without these interactions vanishes for a given value of chemical potential μ and baryon density ρ{sub N}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature-Dependent Characterization, Modeling, and Switching Speed-Limitation Analysis of Third-Generation 10-kV SiC MOSFET

The temperature-dependent characteristics of the third-generation 10-kV/20-A SiC MOSFET including the static characteristics and switching performance are carried out in this paper. The steady-state characteristics, including saturation current, output characteristics, antiparallel diode, and parasitic capacitance, are tested. Here, a double pulse test platform is constructed including a circuit breaker and gate drive with >10-kV insulation and also a hotplate under the device under test for temperature-dependent characterization during switching transients. The switching performance is tested under various load currents and gate resistances at a 7-kV dc-link voltage from 25 to 125 C and compared with previous 10-kV MOSFETs. A simple behavioral model with its parameter extraction method is proposed to predict the temperature-dependent characteristics of the 10-kV SiC MOSFET. The switching speed limitations, including the reverse recovery of SiC MOSFET's body diode, overvoltage caused by stray inductance, crosstalk, heat sink, and electromagnetic interference to the control are discussed based on simulations and experimental results.

10-kV silicon carbide (SiC) metal–oxide–semiconduc↗

Comprehensive Modeling of Temperature-Dependent Degradation Mechanisms in Lithium Iron Phosphate Batteries

For reliable lifetime predictions of lithium-ion batteries, models for cell degradation are required. A comprehensive semi-empirical model based on a reduced set of internal cell parameters and physically justified degradation functions for the capacity loss is developed and presented for a commercial lithium iron phosphate/graphite cell. One calendar and several cycle aging effects are modeled separately. Emphasis is placed on the varying degradation at different temperatures. Degradation mechanisms for cycle aging at high and low temperatures as well as the increased cycling degradation at high state of charge are calculated separately.For parameterization, a lifetime test study is conducted including storage and cycle tests. Additionally, the model is validated through a dynamic current profile based on real-world application in a stationary energy storage system revealing the accuracy. The model error for the cell capacity loss in the application-based tests is at the end of testing below 1 % of the original cell capacity.

25 ENERGY STORAGE↗

Comprehensive Modeling of Temperature-Dependent Degradation Mechanisms in Lithium Iron Phosphate Batteries

For reliable lifetime predictions of lithium-ion batteries, models for cell degradation are required. A comprehensive semi-empirical model based on a reduced set of internal cell parameters and physically justified degradation functions for the capacity loss is developed and presented for a commercial lithium iron phosphate/graphite cell. One calendar and several cycle aging effects are modeled separately. Emphasis is placed on the varying degradation at different temperatures. Degradation mechanisms for cycle aging at high and low temperatures as well as the increased cycling degradation at high state of charge are calculated separately. For parameterization, a lifetime test study is conducted including storage and cycle tests. Additionally, the model is validated through a dynamic current profile based on real-world application in a stationary energy storage system revealing the accuracy. Tests for validation are continued for up to 114 days after the longest parametrization tests. In conclusion, the model error for the cell capacity loss in the application-based tests is at the end of testing below 1% of the original cell capacity and the maximum relative model error is below 21%.

25 ENERGY STORAGE↗

Regional climates in the GISS general circulation model: Surface air temperature

One of the more viable research techniques into global climate change for the purpose of understanding the consequent environmental impacts is based on the use of general circulation models (GCMs). However, GCMs are currently unable to reliably predict the regional climate change resulting from global warming, and it is at the regional scale that predictions are required for understanding human and environmental responses. Regional climates in the extratropics are in large part governed by the synoptic-scale circulation and the feasibility of using this interscale relationship is explored to provide a way of moving to grid cell and sub-grid cell scales in the model. The relationships between the daily circulation systems and surface air temperature for points across the continental United States are first developed in a quantitative form using a multivariate index based on principal components analysis (PCA) of the surface circulation. These relationships are then validated by predicting daily temperature using observed circulation and comparing the predicted values with the observed temperatures. The relationships predict surface temperature accurately over the major portion of the country in winter, and for half the country in summer. These relationships are then applied to the surface synoptic circulation of the Goddard Institute for Space Studies (GISS) GCM control run, and a set of surface grid cell temperatures are generated. These temperatures, based on the larger-scale validated circulation, may now be used with greater confidence at the regional scale. The generated temperatures are compared to those of the model and show that the model has regional errors of up to 10 C in individual grid cells.

Hewitson, Bruce↗

Empirical models of the electron temperature and density in the Venus ionosphere

The electron temperature and density of the Venus ionosphere is characterized using data from the Pioneer Venus orbiter electron temperature probe experiment for the full range of solar zenith angles and local times. Values for the electron density are nearly uniform across the day side with a sharp decrease in the vicinity of the terminator. The model shows a substantial night side ionosphere which can be accounted for by a combination of several transport processes, and by local production by precipitating particles. The electron temperature model demonstrates the high temperatures seen on both the day side and night side. It is found that the night side is much more variable than the day side, and that there is no obvious north-south asymmetry in either the temperature or the density.

Theis, R. F.↗

Measurement and Modeling of Electron Temperature in Laboratory Photoionized Plasmas Relevant to Astrophysics

The electron temperature of photoionized plasmas characterizes the thermalization of photoelectrons, impacts the charge-state distribution, emissivity, and opacity through atomic recombination processes, and is needed to perform detailed comparisons with theory predictions. We discuss temperature measurements in laboratory photoionized plasmas and a comparison with model calculations done with several theory approximations and codes. These include a radiation-hydrodynamics simulation and two nonequilibrium heating and ionization models that tracked the evolution of the internal energy of the electrons. Furthermore, for the same physics model and X-ray flux time history, calculations were performed assuming steady-state or time-dependent conditions. The time history of steady-state results correlates with that of the X-ray flux, while that of the time-dependent cases does not, and it is qualitatively and quantitatively different from the steady-state case. Steady-state results significantly overestimated temperature measurements, while time-dependent results produced better approximations, which suggests the importance of transient effects in the experiment and also the need for time-resolved measurements.

Laboratory astrophysics↗

SU-E-T-267: Development of the Compact Graphite Calorimetry System for the High Energy Photon Beam

Purpose: Graphite calorimeter systems are used for the absolute photon dosimetry. But many electronics are demanded in order to measure the tiny temperature changes. Minimizing the control system is needed to make a portable graphite calorimeter. Methods: A Domen-type graphite calorimetry system is constructing to measure the absorbed dose of the high energy photon beam. The graphite calorimeter divided into three parts, Core, Jacket, and Shield. In order to measure the temperature rising of the core due to the radiation accurately, the temperatures of the jacket and the shield should be controlled properly. A commercial temperature controller (Model 350, Lake Shore Cryogenics) was used to minimize the size of control system for making a portable graphite calorimetry system at the cost of the measurement uncertainty. The PID control of the jacket is conducted by the software (LabView) and Model 350 maintain the temperature of shield. Results: Our design value of the heat deposition power in the core is 0.04 mW for the dose rate of 3 Gy/min where the temperature sensitivity of the graphite is 1.4 mK/Gy. While the residuals of the Steinhart-hart equation fitting for the core thermistor were less than 0.1 mK, the temperature resolution of Model 350 is 1 mK. The temperature of the shield was kept within the 5 mK when the room temperature variation was about 0.5 K. Conclusion: The resolution of Model 350 for the temperature measurement and control is not good enough as the control system for the compact graphite calorimetry system. But The performance of Model 350 is good enough to maintain the temperature of the shield constantly. The Model 350 will be replaced by the AC resistance bridge (Model 372, Lake Shore Cryogenics) for the core temperature measurement and the jacket control.

07 ISOTOPE AND RADIATION SOURCES↗

Model wall and recovery temperature effects on experimental heat transfer data analysis

Basic analytical procedures are used to illustrate, both qualitatively and quantitatively, the relative impact upon heat transfer data analysis of certain factors which may affect the accuracy of experimental heat transfer data. Inaccurate knowledge of adiabatic wall conditions results in a corresponding inaccuracy in the measured heat transfer coefficient. The magnitude of the resulting error is extreme for data obtained at wall temperatures approaching the adiabatic condition. High model wall temperatures and wall temperature gradients affect the level and distribution of heat transfer to an experimental model. The significance of each of these factors is examined and its impact upon heat transfer data analysis is assessed.

Throckmorton, D. A.↗

Validation Studies of RELAP5-3D for High-Temperature Gas-Cooled Reactor Analysis Using a Refined RELAP5-3D Model of the High Temperature Test Facility

RELAP5-3D has been used extensively for high-temperature gas-cooled reactor (HTGR) analysis, but such analysis lies outside the validation basis for the code. Oregon State University (OSU) and the United States Department of Energy’s (DOE) Advanced Reactor Technologies (ART) – Gas-cooled reactor campaign worked together to design and operate the High Temperature Test Facility (HTTF) at OSU to provide validation data for prismatic HTGR thermal hydraulics analysis. Work using a previous RELAP5-3D model of HTTF demonstrated the ability to reproduce trends in HTTF data but an inability to reproduce the values measured in multiple experiments within the uncertainty. It was hypothesized that a new model with a finer radial nodalization would perform better for HTTF analysis. In this paper, we present the development of that more refined model and analyze HTTF experiments PG-27 and PG-29, a pressurized (PCC) and depressurized conduction cooldown (DCC) transient. Comparing PG-27 results to experimental data shows a better prediction of steady state and transient temperatures; however, a deeper dive reveals that better transient temperature predictions are a result of better initial conditions. The transient temperature rise in the core is comparable between the two models, but the legacy model predicts temperatures in the reflectors better. The new model demonstrates the ability to predict unique temperatures in each sector of the core during PG-29, capturing the azimuthal asymmetry; however, the temperature predictions still differ from measured temperatures. One hypothesis is that differences between the assumed and actual power distribution leads to the underprediction of the individual block temperatures. These results suggest that gaps and uncertainties in the measured boundary conditions for the HTTF tests do not allow to fully validate RELAP5-3D for prismatic HTGR analyses. The authors suspect that some of the differences between predicted and measured temperatures may be a result of uncertainties associated with HTTF itself rather than RELAP5-3D. We demonstrated improved validation for steady-state analysis, but significantly improved transient performance has yet to be recognized.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Interactive initialization of heat flux parameters for numerical models using satellite temperature measurements

Efforts were made (1) to bring the image processing and boundary layer model operation into a completely interactive mode and (2) to test a method for determining the surface energy budget and surface moisture availability and thermal inertia on a scale appreciably larger than that of the city. A region a few hundred kilometers on a side centered over southern Indiana was examined.

Carlson, T. N.↗

Effects of Material Degradation on the Structural Integrity of Composite Materials: Experimental Investigation and Modeling of High Temperature Degradation Mechanisms

It has previously been demonstrated that simple coupled reaction-diffusion models can approximate the aging behavior of PMR-15 resin subjected to different oxidative environments. Based on empirically observed phenomena, a model coupling chemical reactions, both thermal and oxidative, with diffusion of oxygen into the material bulk should allow simulation of the aging process. Through preliminary modeling techniques such as this it has become apparent that accurate analytical models cannot be created until the phenomena which cause the aging of these materials are quantified. An experimental program is currently underway to quantify all of the reaction/diffusion related mechanisms involved. The following contains a summary of the experimental data which has been collected through thermogravimetric analyses of neat PMR-15 resin, along with analytical predictions from models based on the empirical data. Thermogravimetric analyses were carried out in a number of different environments - nitrogen, air and oxygen. The nitrogen provides data for the purely thermal degradation mechanisms while those in air provide data for the coupled oxidative-thermal process. The intent here is to effectively subtract the nitrogen atmosphere data (assumed to represent only thermal reactions) from the air and oxygen atmosphere data to back-figure the purely oxidative reactions. Once purely oxidative (concentration dependent) reactions have been quantified it should then be possible to quantify the diffusion of oxygen into the material bulk.

Cunningham, Ronan A.↗

Thermodynamic and Diffusion Model Estimates on Metamorphic Temperatures and Timescales for Basaltic Eucrite GRA 98098

Introduction: HED meteorites are thought to rep-resent igneous rocks from Vesta’s basaltic crust and preserve evidence of early crustal metamorphism. Determining the temperatures and timescales of thermal metamorphism is important for reconstructing crustal evolution in the early solar system. Here, we study basaltic eucrite Graves Nunataks (GRA) 98098, which has been identified as a highly metamorphosed eucrite [1]. We present new estimates on metamorphic temperatures determined via thermodynamic modeling as well as the initial results from diffusion models constraining timescales of thermal metamorphism. Sample Description: GRA 98098 is an unbrecciated eucrite with a granoblastic plagioclase and pyroxene mineralogy. Millimeter to cm-long lathes of tridymite cross-cut and poikilitically enclose plagioclase and pyroxene [1,this work]. Pyroxene grains have exsolved into Ca-rich (~Wo38En29Fs33) and Ca-poor (~Wo4.5En36Fs59.5) lamellae. Both unzoned and zoned plagioclase grains are observed. Unzoned plagioclase grains are found solely with tridymite laths. These grains have ~An92 compositions. The cores of the zoned plagioclase grains have the same composition and thin, relatively sodic rims (~An67), (Fig. 1). The bulk sample is unusually enriched in highly in-compatible elements and has one of the most fractionated REE patterns reported [1]. Maximum metamorphic temperatures of 985±78°C have been estimated using two-pyroxene thermometry [2]. Methods: Thermodynamic modeling. Thermodynamic models were constructed using the software Perple_X, which employs a Gibbs free energy minimization in order to determine the most stable phase assemblage for a given bulk rock composition [3]. Bulk composition was calculated using mineral com-positions acquired via EMPA (this study) and the observed abundancies present in the thin section. Two bulk compositions were estimated; 1) includes all phases present in the thin section, (assumes that all phases are present during metamorphism), 2) excludes tridymite from the bulk calculation (assumes that tridymite was not present during metamorphism). In order to determine whether metamorphic equilibria was achieved and estimate temperatures of metamorphism, we compared measured pyroxene compositions with thermodynamically predicted compositions [4, Fig. 2]. Diffusion Modeling. Several time-temperature de-pendent diffusion profiles were calculated in order to determine the best match for XAn chemical profiles observed at the edges of the zoned plagioclase (Fig. 3). We assumed that the start condition was a stepwise gradient at the plagioclase/pyroxene interface. We also assumed an average diffusion coefficient (D) and a constant temperature using the equation in [5]. D was determined for two temperatures (T = 1060ºC; near eucrite solidus [6] and T = 985ºC; metamorphism reported in [4]) and then XAn was calculated as a function of distance from plagioclase core to rim using an error function solution to Fick’s second law. Results: Thermodynamic model results are summarized in Fig. 2. For a bulk composition that includes all phases in the thin section, pyroxene endmember compositions plot in the following temperature ranges: Fs ~660-860ºC, En~1000ºC & 1150ºC, and Wo~760-900ºC (Fig. 2a). For a bulk composition that excludes tridymite from the peak metamorphic assemblage (i.e., the bulk composition minus the contribution from tridymite), a temperature range could not be determined for the Fs component of pyroxene. For Wo, T~760-900ºC and En, T~1000ºC & 1150ºC (Fig. 2b). Fig. 3 summarizes the diffusion model results. For T = 1060°C & 985°C, the most appropriate time interval was estimated based on which diffusion curve most matched (solid lines, Fig. 3) the EMPA data. For T = 1060°C, the best looking match was t = 500 ka. For T = 985°C, the best match was t = 7 Ma. Discussion and future work: Temperature estimates from thermodynamic models are not conclusive because the temperature ranges determined for pyroxene endmember stability do not overlap (colored fields in Fig. 2), thus implying that there is disequilibrium between pyroxene crystals and the bulk composition considered [4]. Thus, additional exploration is needed to define a metamorphically equilibrated do-main that accurately records peak temperature. The utility of defining metamorphically equilibrated do-mains to improve the accuracy and level of detail elucidated regarding the petrogenetic history of metamorphose samples has been demonstrated previously [4,7]. We suggest that in the case of Fig. 2a, the thin section composition is not representative of the length scales over which metamorphic equilibrium was achieve and in the case of Fig. 2b, the assumption that tridymite was not present during metamorphism was incorrect. However, results from thermodynamic models can provide insight into the relative timing of mineral and compositional textures. For example from texture alone, it is unclear whether tridymite was igneous in origin and represents the last bits of melt in a crystallizing magma chamber, or if it formed during (and possibly initiated) open system thermal metamorphism. The latter could be consistent with a partial melt hypothesis [8,9] while the former implies that simple fractional crystallization can yield the textures present in GRA 98098. The lack of coincidence be-tween pyroxene endmember compositions in Fig. 2b suggest that the bulk composition minus tridymite was not the assemblage in equilibrium with the pyroxene, suggesting that tridymite was present during metamorphism and formed during igneous crystallization. We conclude that the development of the Na-rich plagioclase rims likely occurred during or immediately after peak thermal metamorphism, because eucrites of similar metamorphic grade and texture have unzoned plagioclase (~An92) [2,4,8], and Na zoning is only observed in the plagioclase not included in the tridymite. This suggests that the zoning formed after tridymite formation, and therefore after igneous crystallization. Thus, the timescales calculated via diffusion modeling possibly represent the time interval over which thermal metamorphism occurred. Cooling rates approximated for the Vestan crust predict that the crust cooled below 300°C around 35-40 Ma after formation[10]. This is consistent with our modeling results that predict formation of the Na rich plagioclase rims occurring at higher temperatures over a period of 0.5 to 7 Ma years. Future work. Additional thermodynamic modeling work will focus on selecting an equilibrated bulk rock domain in which to elucidate metamorphic conditions. Diffusion models currently provide a minimum time-scale, since diffusion slows down as the system cools. Future work with will focus on integrating cooling into the diffusion models and constraining the depth at which thermal metamorphism occurs because it could be used to determine whether the range of time-scales calculated for thermal metamorphism are consistent with the geologic environment.

J S Gorce↗