Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Dual-Line Detection Rayleigh Scattering Measurements of Density and Temperature

Measurements of the laser Rayleigh scattering signal in a flow to determine density and temperature have been commonly employed in open flames and in wind tunnel environments. In these measurements, the density or reciprocal temperature is correlated with the Rayleigh scattering signal intensity. A major advantage of Rayleigh scattering for these applications is the simple experimental arrangement allowed by this technique. Intensity-based Rayleigh scattering measurements of density and temperature have been limited to relatively clean flows in open environments so that interference from particle scattering and laser scattering is minimal. A new approach, using dual-line detection Rayleigh (DLDR) scattering extends the applicability of Rayleigh scattering measurements of density and temperature to enclosed environments where surface scattering interference is high. Depending on particle size and optical properties, this approach may also reduce interference from particle scattering.

Annen, Kurt↗

Containerless High Temperature Property Measurements by Atomic Fluorescence

Laser induced fluorescence (LIF) provides a noncontact method for measuring high temperature properties. It is used with aerodynamic and/or electromagnetic levitation, and electromagnetic and/or CW CO2 laser heating to develop new methods for containerless high temperature property measurements and process control. The capabilities and limitations of Earth-based experiments are demonstrated and the information necessary to design improved experiments in space is obtained. The LIF methods were developed to measure temperature and component activities, which will be applied to containerless property measurements on liquids and to process control in synthesis experiments. Component activities will be obtained from relative LIF intensities over a compound and its components at the same temperature.

Nordine, P. C.↗

Remote measurement of atmospheric temperatures by Raman lidar

The Raman shifted return of a lidar system has been utilized to make atmospheric temperature measurements. The measurements were made along a horizontal path at temperatures ranging from -30 C to +30 C and at ranges of about 100 meters. The temperature data were acquired by recording the intensity ratio of two portions of the rotational Raman spectrum which were simultaneously sampled from a preset range. A temperature measurement accuracy of plus or minus 4 C and a temporal resolution of one minute were realized with this system. The combined results of the theoretical analysis and the experimentation indicate that system improvements will significantly increase both accuracy and range.

Coney, T. A.↗

Comparison of fiber-optic distributed temperature sensing and high-sensitivity sensor spatial surveying of stream temperature

Measuring surface water temperature spatial variability is needed to estimate the interaction between surface water and groundwater, evaluate fish habitat and thermal inertia, and to estimate streamflow frequency and duration. Fiber optic distributed temperature sensing (FO-DTS) has been used in rivers and lakes, providing high-resolution and sensitive temperature monitoring over large temporal and spatial scales. However, in streams with cobbly or bedrock-lined streambeds and variable bathymetry, use of FO-DTS to measure temperature close to the surface water and groundwater interface can be challenging if even feasible. FO-DTS can also be costly, involve difficult installations, and require an advanced understanding of the technology, calibration, and data processing. In this study, we compared FO-DTS stream temperature survey results to an alternative temperature survey method employing a towed transect of high-resolution temperature loggers spaced at 1-m and transported in the stream along the study reach, to measure the spatial distribution of stream-water temperature in East Fork Poplar Creek near Oak Ridge, Tennessee, USA. We assessed the applicability and limitations of the two methods, and quantitatively compared in-situ temperature survey results measured simultaneously with each method. Regression results showed strong temporal and spatial correlation between the two methods. Differences were only elevated near the stream banks in areas that were coincident with correlation slope deviations from unity, which was attributed to shallower water and lower data density. Kriging standard errors were also low at channel center with minor increases near the stream banks. Furthermore, the results suggested that the array of the individual temperature sensors can provide a practical alternative to FO-DTS for thermal characterization of surface water, providing slightly lower spatial and temporal resolution, but with higher accuracy of temperature measurement, with greater simplicity, and with a broader range of conditions where it may be applied.

54 ENVIRONMENTAL SCIENCES↗

Measurements of Temperature Variations in the Atmosphere near the Tropopause with Reference to Airspeed Calibration by the Temperature Method

Measurements of temperature variations in the atmosphere near the tropopause over land in the vicinity of Langley Field, Va., are presented. This investigation was made for the purpose of obtaining information on the accuracy of the temperature method(NACA TN 2046) of airspeed calibration over the range of Mach number from 0.6 to .08. The temperature surveys and the description of a specially designed thermometer are also presented.

INSTRUMENTS, METEOROLOGICAL↗

Noncontact measurement of high temperature using optical fiber sensors

The primary goal of this research program was the investigation and application of noncontact temperature measurement techniques using optical techniques and optical fiber methods. In particular, a pyrometer utilizing an infrared optical light pipe and a multiwavelength filtering approach was designed, revised, and tested. This work was motivated by the need to measure the temperatures of small metallic pellets (approximately 3 mm diameter) in free fall at the Microgravity Materials Processing Drop Tube at NASA Marshall Space Flight Center. In addition, research under this program investigated the adaptation of holography technology to optical fiber sensors, and also examined the use of rare-earth dopants in optical fibers for use in measuring temperature. The pyrometer development effort involved both theoretical analysis and experimental tests. For the analysis, a mathematical model based on radiative transfer principles was derived. Key parameter values representative of the drop tube system, such as particle size, tube diameter and length, and particle temperature, were used to determine an estimate of the radiant flux that will be incident on the face of an optical fiber or light pipe used to collect radiation from the incandescent falling particle. An extension of this work examined the advantage of inclining or tilting the collecting fiber to increase the time that the falling particle remains in the fiber field-of-view. Those results indicate that increases in total power collected of about 15 percent may be realized by tilting the fiber. In order to determine the suitability of alternative light pipes and optical fibers, and experimental set-up for measuring the transmittance and insertion loss of infrared fibers considered for use in the pyrometer was assembled. A zirconium fluoride optical fiber and several bundles of hollow core fiber of varying diameters were tested. A prototype two-color pyrometer was assembled and tested at Virginia Tech, and then tested on the Drop Tube at Marshall Space Flight Center. Radiation from 5 mm diameter niobium drops falling in the Drop Tube was successfully detected, and recorded for later analysis. Subsequent analysis indicated that the imaging of light output from the light pipe onto the detector active areas was not identical for both detectors.

Claus, R. O.↗

High-Temperature Sprayable Phosphor Coating Developed for Measuring Surface Temperatures

The use of phosphor thermography for noncontact temperature measurements in harsh environments has been proven over the last decade, but it has suffered from difficult application procedures such as vapor deposition or sputtering techniques. We have developed a high-temperature-sensitive paint that is easily applied with commercially available paint-spraying equipment and have successfully demonstrated it to temperatures up to 1500 C. Selected phosphors have also shown measurable signals to 1700 C, thus allowing a combination of phosphors to be used in high-temperature binders to make surface temperature measurements from ambient to over 1500 C. Phosphor thermography is an optical technique that measures the time response of fluorescence light, which is a function of the phosphor temperature. The phosphors are excited with short wavelength light (ultraviolet or blue), and they emit light at a longer wavelength. This technique has a benefit over other temperature measurements, such as thermocouples and infrared thermography, in difficult environments such as high blackbody backgrounds, vibration, flames, high electromagnetic noise, or where special windows may be needed. In addition, the sprayable phosphor paints easily cover large or complicated structures, providing full-surface information with a single measurement. Oak Ridge National Laboratories developed and tested the high-temperature binders and phosphors under the direction of the NASA Glenn Research Center. Refractory materials doped with rare earth metals were selected for their performance at high temperature. Survivability, adhesion, and material compatibility tests were conducted at high temperatures in a small furnace while the fluorescent response from the phosphors was being measured. A painted sample in a furnace with a clearly visible fluorescing dot excited by a pulsed laser is shown. Measuring the decay time of this fluorescence yields the surface temperature. One new paint was recently tested in a rocket test stand at Glenn. The floor of a square duct nozzle was painted, and full-field lifetime decay measurements were acquired for multiple firings of the rocket. Good agreement with predicted results was obtained, matching temperature gradients along the length of the nozzle and clearly showing shock structures. These good results were very satisfactory given that the measurements were made looking through the combustion plume. Infrared pyrometry was incapable of making the surface measurements because of the interference from the rocket exhaust, which contaminated the infrared signature.

Bencic, Timothy J.↗

Remote Sensing of Earth's Surface and Atmosphere: Interdisciplinary Scientific Commission A of the COSPAR Plenary Meeting, 29th, Washington, DC, 28 Aug. - 5 Sep., 1992

This conference reviewed the recent developments in remote monitoring of surface temperatures, which will be significant in future global change studies. Various techniques to derive surface temperature from existing and future remote sensing systems such as earth observing system (EOS) are discussed. Five sessions were held: (1) The nature of the problem of remote sensing of surface temperatures; (2) Surface temperature measurements from current satellites; (3) Modeling and surface observations of various techniques to measure temperature and/or emissivity, modeling of vegetation; (4) The effects of variable spectral emissivity from the determination of surface kinetic temperature using multispectral thermal infrared measurements; and (5) Future satellite systems including EOS/ASTER, EOS/MODIS-N, and EOS/AIRS.

Kahle, A. B.↗

Measuring the Surface Temperature of the Cryosphere using Remote Sensing

A general description of the remote sensing of cryosphere surface temperatures from satellites will be provided. This will give historical information on surface-temperature measurements from space. There will also be a detailed description of measuring the surface temperature of the Greenland Ice Sheet using Moderate-Resolution Imaging Spectroradiometer (MODIS) data which will be the focus of the presentation. Enhanced melting of the Greenland Ice Sheet has been documented in recent literature along with surface-temperature increases measured using infrared satellite data since 1981. Using a recently-developed climate data record, trends in the clear-sky ice-surface temperature (IST) of the Greenland Ice Sheet have been studied using the MODIS IST product. Daily and monthly MODIS ISTs of the Greenland Ice Sheet beginning on 1 March 2000 and continuing through 31 December 2010 are now freely available to download at 6.25-km spatial resolution on a polar stereographic grid. Maps showing the maximum extent of melt for the entire ice sheet and for the six major drainage basins have been developed from the MODIS IST dataset. Twelve-year trends of the duration of the melt season on the ice sheet vary in different drainage basins with some basins melting progressively earlier over the course of the study period. Some (but not all) of the basins also show a progressively-longer duration of melt. The consistency of this IST record, with temperature and melt records from other sources will be discussed.

Hall, Dorothy K.↗

Simultaneous Temperature and Velocity Measurements in a Large-Scale, Supersonic, Heated Jet

Two laser-based measurement techniques have been used to characterize an axisymmetric, combustion-heated supersonic jet issuing into static room air. The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) measurement technique measured temperature and concentration while the interferometric Rayleigh scattering (IRS) method simultaneously measured two components of velocity. This paper reports a preliminary analysis of CARS-IRS temperature and velocity measurements from selected measurement locations. The temperature measurements show that the temperature along the jet axis remains constant while dropping off radially. The velocity measurements show that the nozzle exit velocity fluctuations are about 3% of the maximum velocity in the flow.

Danehy, P. M.↗

Simulation of the PBX 9501 Self-Ignited Heavily Confined Cookoff Test

The PBX 9501 self-ignited thermally damaged explosive (SITX) test was carried out by Holmes et al. A 6-inch diameter sphere made of the PBX 9501 was heated inside a steel confinement vessel until it underwent a thermal explosion. This test provided measured temperature data that was used to define a boundary condition to carry out post-experiment finite element (FE) thermal simulations and comparisons of the FE thermal response with the experimental time to thermal ignition and internal temperature measurements at the center of the PBX 9501 sphere. Finite element models of this experiment were constructed using the heat transfer code Aria. A cookoff model for PBX 9501 was used to simulate the thermal decomposition of PBX 9501 and to predict the time to thermal ignition. An inverse heat conduction scheme was designed and applied to estimate a 1D temperature boundary condition.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Remote Measurement of Atmospheric Temperatures By Raman Lidar

The Raman shifted return of a lidar, or optical radar, system has been utilized to make atmospheric temperature measurements. These measurements were made along a horizontal path at temperatures between -20 C and +30 C and at ranges of about 100 meters. The temperature data were acquired by recording the intensity ratio of two portions of the Raman spectrum which were simultaneously sampled from a preset range. The lidar unit employed in this testing consisted of a 4 joule-10ppm laser operating at 694.3 nm, a 10-inch Schmidt-Cassegrain telescope, and a system of time-gated detection and signal processing electronics. The detection system processed three return signal wavelength intervals - two intervals along the rotational Raman scattered spectrum and one interval centered at the Rayleigh-Mie scattered wavelength. The wavelength intervals were resolved by using a pellicle beam splitter and three optical interference filters. Raman return samples were taken from one discrete range segment during each test shot and the signal intensities were displayed in digital format. The Rayleigh-Mie techniques. The test site utilized to evaluate this measurement technique encompassed a total path length of 200 meters. Major components of the test site included a trailer-van housing the lidar unit, a controlled environment test zone, and a beam terminator. The control zone which was located about 100 meters from the trailer was 12 meters in length, 2.4 meters in diameter, and was equipped with hinged doors at each end. The temperature of the air inside the zone could be either raised or lowered with respect to ambient air through the use of infrared heaters or a liquid-nitrogen cooling system. Conditions inside the zone were continuously monitored with a thermocouple rake assembly. The test path length was terminated by a 1.2 meter square array of energy absorbing cones and a flat black screen. Tests were initially conducted at strictly ambient conditions utilizing the normal outside air temperatures as a test parameter. These tests provided a calibration of the Raman intensity ratio as a function of' temperature for the particular optical-filter arrangement used in this system while also providing a test of' the theoretical prediction formulated in the design of the system. Later tests utilized zone temperatures above and below ambient to provide temperature gradient data. These tests indicate that ten shots, or one minute of' data acquisition, from a 100 meter range can provide absolute temperature measurements with an accuracy of + 30 C and a range resolution of about 5 meters. Because this measurement accuracy compares well with that predicted for this particular unit, it is suggested that a field-application system could be built with signif'icant improvements in both absolute accuracy and range.

Salzman, Jack A.↗

Thermal conductance of interfaces between titanium nitride and group IV semiconductors at high temperatures

Measuring the temperature dependence of material properties is a standard method for better understanding the microscopic origins for that property. Surprisingly, only a few experimental studies of thermal boundary conductance at high temperatures exist. This lack of high temperature data makes it difficult to evaluate competing theories for how inelastic processes contribute to thermal conductance. To address this, we report time domain thermoreflectance measurements of the thermal boundary conductance for TiN on diamond, silicon-carbide, silicon, and germanium between 120 and 1000 K. In all systems, the interface conductance increases monotonically without stagnating at higher temperatures. For TiN/SiC interfaces, G ranges from 330 to 1000 MW/m2-K, with a room temperature conductance of 750 MW/m2-K. The interface conductance for TiN/diamond ranges from 140 to 950 MW/m2-K. Notably, for all four interfacial systems, the conductance continues to increase with temperature even after all phonon modes in the vibrationally soft material are thermally excited. This observation suggests that inelastic processes are significant contributors to the thermal conductance in all four interfacial systems, regardless of whether the materials forming the interface are vibrationally similar or dissimilar. Our study fills a notable gap in the literature for how interfacial conductance evolves at high temperatures and tests burgeoning theories for the role of inelastic processes in interfacial thermal transport.

Physics↗

Evaluation of a surface/vegetation parameterization using satellite measurements of surface temperature

Ground measurements of surface-sensible heat flux and soil moisture for a wheat-growing area of Beauce in France were compared with the values derived by inverting two boundary layer models with a surface/vegetation formulation using surface temperature measurements made from NOAA-AVHRR. The results indicated that the trends in the surface heat fluxes and soil moisture observed during the 5 days of the field experiment were effectively captured by the inversion method using the remotely measured radiative temperatures and either of the two boundary layer methods, both of which contain nearly identical vegetation parameterizations described by Taconet et al. (1986). The sensitivity of the results to errors in the initial sounding values or measured surface temperature was tested by varying the initial sounding temperature, dewpoint, and wind speed and the measured surface temperature by amounts corresponding to typical measurement error. In general, the vegetation component was more sensitive to error than the bare soil model.

Taconet, O.↗