Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Technology Performance Exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Assessment of exchange-correlation functionals on oxygen vacancy formation energies of metal oxides

Oxygen vacancies are a common defect in oxides and play vital roles in many technological applications such as oxygen separation, catalytic reactors, solid oxide fuel cells, and solar thermochemical water splitting. The oxygen vacancy formation energy is directly related to the oxide reduction enthalpy and the vacancy concentration and, therefore, is a key quantity underlying these applications. The complexity of measuring oxygen vacancy formation energies experimentally suggests the utility of calculations based on density functional theory (DFT). However, the calculated results are strongly dependent on the exchange-correlation functionals and other parameters such as the Hubbard U . In this work, we compare the performance of the meta-GGA strongly constrained and appropriately normed (SCAN) functional and the commonly used semilocal generalized gradient approximation (GGA) functionals with experimental values of structural parameters, band gaps, magnetic structures, and oxygen vacancy formation energies for six representative oxides, i.e., CaMnO 3 , SrMnO 3 , LaMnO 3 , YMnO 3 , LaFeO 3 , and CeO 2 . Further, our results show that SCAN usually has better agreement with the experimental lattice constants and band gaps and larger magnetic moments than the commonly used GGA functionals. Although SCAN overestimates the oxygen vacancy formation energies of transition metal oxides and therefore requires unusually large Hubbard U values to reproduce the experimental reduction enthalpies, it does predict the correct oxygen vacancy formation energy of CeO 2 , which challenges the commonly used GGA and hybrid functionals. Our results underscore the challenges that exist in describing these complex oxides by DFT and may shed light on developing more accurate exchange-correlation functionals for oxygen vacancy formation energy calculations.

36 MATERIALS SCIENCE↗

High Efficiency Nuclear Power Plants Using Liquid Fluoride Thorium Reactor Technology

An overall system analysis approach is used to propose potential conceptual designs of advanced terrestrial nuclear power plants based on Oak Ridge National Laboratory (ORNL) Molten Salt Reactor (MSR) experience and utilizing Closed Cycle Gas Turbine (CCGT) thermal-to-electric energy conversion technology. In particular conceptual designs for an advanced 1 GWe power plant with turbine reheat and compressor intercooling at a 950 K turbine inlet temperature (TIT), as well as near term 100 MWe demonstration plants with TITs of 950 and 1200 K are presented. Power plant performance data were obtained for TITs ranging from 650 to 1300 K by use of a Closed Brayton Cycle (CBC) systems code which considered the interaction between major sub-systems, including the Liquid Fluoride Thorium Reactor (LFTR), heat source and heat sink heat exchangers, turbo-generator machinery, and an electric power generation and transmission system. Optional off-shore submarine installation of the power plant is a major consideration.

Juhasz, Albert J.↗

Increasing the efficiency of a carbon dioxide refrigeration system using a pressure exchanger

Natural refrigerants such as carbon dioxide (R744) are gaining increased interest as industry searches for alternatives with minimal environmental impacts. However, R744-based systems have lower operating efficiencies as compared to hydrofluorocarbon-based systems, particularly in hot climates. Implementing pressure exchanger (PX) technology may enable R744 systems to operate over a broader range of operating temperatures. A PX consists of narrow longitudinal channels positioned radially around a rotating cylinder. High- and low-pressure fluids flow into the PX and exchange pressure, creating an intermediate-pressure flow. In this paper, the design of the PX will be discussed, and a model of the PX will be developed. Refrigeration system designs implementing the PX will be presented. It will be shown that the PX has the potential to boost the coefficient of performance (COP) of R744 systems by over 25% compared to standard transcritical R744 booster systems.

Fricke, Brian↗

Multimodal In Situ Characterization Uncovers Unexpected Stability of a Cobalt Electrocatalyst for Acidic Sustainable Energy Technologies

An accelerated development of durable and affordable sustainable energy technologies is often hindered by a limited understanding of how non-precious materials within these systems degrade. In acidic proton exchange membrane fuel cells and water electrolyzers, metallic cobalt (Co) is considered an unstable component that is often combined with precious metals or other stabilizers. To understand the mechanisms behind Co instability, we employ an experimental platform that quantifies dissolution with on-line inductively coupled plasma mass spectrometry and product formation with electrochemical mass spectrometry during electrochemical testing, along with ex- situ characterization. Under varied conditions (electrocatalysis, time, gas-type saturation, and ion concentration), windows of Co stability are observed that are different than predicted with classical chemical thermodynamics, suggesting new stabilization and degradation mechanisms than previously understood. Notably, Co is active for the hydrogen evolution reaction (HER), with prolonged stability that is ~300 mV different than thermodynamically projected. Additionally, in an oxygenated environment, Co concurrently performs the HER and oxygen reduction reaction (ORR) yet undergoes different morphology changes and dissolution mechanisms. Interestingly, in the absence of electrocatalysis, there is a 22x decrease in dissolution in an oxygen-free environment, proposing a route to decrease Co losses during device shutdown protocols. Lastly, under more extreme operating conditions, Co becomes stable after a substantial amount of dissolution, suggesting that high concentrations of Co 2+ ions in the microenvironment induce the formation of a stable CoHO 2 surface. Altogether, these results can be leveraged to improve the design and development of more robust and cost-effective sustainable energy technologies, as well as promote strategic strategies for prolonged material utilization.

Dissolution↗

Technology-enabled Airborne Spacing and Merging

Over the last several decades, advances in airborne and groundside technologies have allowed the Air Traffic Service Provider (ATSP) to give safer and more efficient service, reduce workload and frequency congestion, and help accommodate a critically escalating traffic volume. These new technologies have included advanced radar displays, and data and communication automation to name a few. In step with such advances, NASA Langley is developing a precision spacing concept designed to increase runway throughput by enabling the flight crews to manage their inter-arrival spacing from TRACON entry to the runway threshold. This concept is being developed as part of NASA s Distributed Air/Ground Traffic Management (DAG-TM) project under the Advanced Air Transportation Technologies Program. Precision spacing is enabled by Automatic Dependent Surveillance-Broadcast (ADS-B), which provides air-to-air data exchange including position and velocity reports; real-time wind information and other necessary data. On the flight deck, a research prototype system called Airborne Merging and Spacing for Terminal Arrivals (AMSTAR) processes this information and provides speed guidance to the flight crew to achieve the desired inter-arrival spacing. AMSTAR is designed to support current ATC operations, provide operationally acceptable system-wide increases in approach spacing performance and increase runway throughput through system stability, predictability and precision spacing. This paper describes problems and costs associated with an imprecise arrival flow. It also discusses methods by which Air Traffic Controllers achieve and maintain an optimum interarrival interval, and explores means by which AMSTAR can assist in this pursuit. AMSTAR is an extension of NASA s previous work on in-trail spacing that was successfully demonstrated in a flight evaluation at Chicago O Hare International Airport in September 2002. In addition to providing for precision inter-arrival spacing, AMSTAR provides speed guidance for aircraft on converging routes to safely and smoothly merge onto a common approach. Much consideration has been given to working with operational conditions such as imperfect ADS-B data, wind prediction errors, changing winds, differing aircraft types and wake vortex separation requirements. A series of Monte Carlo simulations are planned for the spring and summer of 2004 at NASA Langley to further study the system behavior and performance under more operationally extreme and varying conditions. This will coincide with a human-in-the-loop study to investigate the flight crew interface, workload and acceptability.

Hull, James↗

Sensitivity of Hollow Fiber Spacesuit Water Membrane Evaporator Systems to Potable Water Constituents, Contaminants and Air Bubbles

The Spacesuit Water Membrane Evaporator (SWME) is the baseline heat rejection technology selected for development for the Constellation lunar suit. The first SWME prototype, designed, built, and tested at Johnson Space Center in 1999 used a Teflon hydrophobic porous membrane sheet shaped into an annulus to provide cooling to the coolant loop through water evaporation to the vacuum of space. This present study describes the test methodology and planning and compares the test performance of three commercially available hollow fiber materials as alternatives to the sheet membrane prototype for SWME, in particular, a porous hydrophobic polypropylene, and two variants that employ ion exchange through non-porous hydrophilic modified Nafion. Contamination tests will be performed to probe for sensitivities of the candidate SWME elements to ordinary constituents that are expected to be found in the potable water provided by the vehicle, the target feedwater source. Some of the impurities in potable water are volatile, such as the organics, while others, such as the metals and inorganic ions are nonvolatile. The non-volatile constituents will concentrate in the SWME as evaporated water from the loop is replaced by the feedwater. At some point in the SWME mission lifecycle as the concentrations of the non-volatiles increase, the solubility limits of one or more of the constituents may be reached. The resulting presence of precipitate in the coolant water may begin to plug pores and tube channels and affect the SWME performance. Sensitivity to macroparticles, lunar dust simulant, and air bubbles will also be investigated.

Bue, Grant C.↗

High Efficiency Nuclear Power Plants using Liquid Fluoride Thorium Reactor Technology

An overall system analysis approach is used to propose potential conceptual designs of advanced terrestrial nuclear power plants based on Oak Ridge National Laboratory (ORNL) Molten Salt Reactor (MSR) experience and utilizing Closed Cycle Gas Turbine (CCGT) thermal-to-electric energy conversion technology. In particular conceptual designs for an advanced 1 GWe power plant with turbine reheat and compressor intercooling at a 950 K turbine inlet temperature (TIT), as well as near term 100 MWe demonstration plants with TITS of 950 K and 1200 K are presented. Power plant performance data were obtained for TITS ranging from 650 to 1300 K by use of a Closed Brayton Cycle (CBC) systems code which considered the interaction between major sub-systems, including the Liquid Fluoride Thorium Reactor (LFTR), heat source and heat sink heat exchangers, turbo -generator machinery, and an electric power generation and transmission system. Optional off-shore submarine installation of the power plant is a major consideration.

Juhasz, Albert J.↗

Solvation Properties of Silver and Copper Ions in a Room Temperature Ionic Liquid: A First-Principles Study

Understanding the behavior of metal ions in room temperature ionic liquids (ILs) is essential for predicting and optimizing performance for technologies like metal electrodeposition; however, many mechanistic details remain enigmatic, including the solvation properties of the ions in ILs and how they are governed by the intrinsic interaction between the ions and the liquid species. Here, we utilize first-principles molecular dynamics simulations to unravel and compare the key structural properties of Ag + and Cu + ions in a common room temperature IL, 1-ethyl-3-methylimidazolium trifluoromethanesulfonate. We find that, when compared to Cu + , the larger Ag + shows a more disordered and flexible solvation structure with a more frequent exchange of the IL species between its solvation shells. In addition, our simulations reveal an interesting analog in the solvation behavior of the ions in the IL and aqueous environments, particularly in the effect of the ion electronic structures on their solvation properties. As a result, this work provides fundamental understanding of the intrinsic properties of the metal ions in the IL, while offering mechanistic understanding and strategy for future selection of ILs for metal electrodeposition processes.

36 MATERIALS SCIENCE↗

Anion Exchange Membrane Electrolyzers as Alternative for Upgrading of Biomass-Derived Molecules

Upgrading biomass derived platform molecules to fuels or chemicals provides a unique alternative for the substitution of fossil sources with renewables. Electrochemical reduction (ECR) is one of the upgrading technologies, alternative to catalytic reduction, which only requires electricity as the energy input, which can be derived from carbon free energy sources. Moreover, ECR does not require external addition of hydrogen, as this can be generated in-situ. In this work an anion exchange membrane (AEM) electrolyte assembly (MEA) has been tested for the efficient reduction of biomass derived molecules, and compared with a cation exchange membrane (CEM) MEA. The cathode electrocatalyst has been modified with the addition of hydrophobicity and anion exchange ionomers, and incorporated onto an anion exchange membrane. Electrochemical experiments were performed with a metal free electrocatalyst in the presence and absence of surrogate compounds. The results showed that changes in the catalyst formulation can increase the overpotential for the competing hydrogen evolution reaction (HER), while significantly enhancing the reduction of the organic molecules. Bulk electrolysis experiments demonstrated higher efficiencies for furfural ECR in an AEM-MEA vs. AEM-CEM, reaching conversions up to 94% at 50 mA cm 2 and in the absence of supporting electrolyte. Moreover, AEM-MEA was able to facilitate water management during the reduction process and contribute to the separation of small carboxylic acids.

09 BIOMASS FUELS↗

Indoor air quality in 24 California residences designed as high-performance homes

Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California. Although the mechanically vented homes were six times as airtight as non-mechanically ventilated homes (medians of 1.1 and 6.1 ACH 50 , n=11 and n=8, respectively), their use of mechanical ventilation systems and possibly window operation meant their median air exchange rates were almost the same (0.30 versus 0.32 hr -1 , n=8 and n=8, respectively). Pollutant levels were also similar in vented and unvented homes. In addition, these similarities were achieved despite numerous observed faults in complex mechanical ventilation systems. More rigorous commissioning is still recommended. Cooking exhaust systems were used inconsistently and several suffered from design flaws. Failure to follow best practices led to IAQ problems in some cases. Ambient nitrogen dioxide standards were exceeded or nearly so in four homes that either used gas ranges with standing pilots, or in Passive House-style homes that used gas cooking burners without venting range hoods. Homes without active particle filtration had particle count concentrations approximately double those in homes with enhanced filtration. The majority of homes reported using low-emitting materials; consistent with this, formaldehyde levels were approximately half those in conventional, new CA homes built before 2008. Emissions of ultrafine particles (with diameters <100 nm) were dramatically lower on induction electric cooktops, compared with either gas or resistance electric models. These results indicate that high performance homes can achieve acceptable and even exceptional IAQ by providing adequate general mechanical ventilation, using low-emitting materials, providing mechanical particle filtration, incorporating well-designed exhaust ventilation for kitchens and bathrooms, and educating occupants to use the kitchen and bath ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LCOE*: Re-Thinking LCOE for Photovoltaic Systems

Solar industry is working towards reducing the levelized cost of energy (LCOE). The LCOE formulation includes various implicitly connected cost and physical design parameters. This entails complex cost analyses by economists, and electrical analysis and energy yield calculations of solar farms by device physicists/technologists. The standard formulation requires a constant exchange of information to optimize the design of a specific farm. In this paper, we present a fundamental reformulation of LCOE (in terms of LCOE*) to deconvolve the cost vs. energy yield analysis so that economists and technologists can work independently towards minimizing LCOE. We validate our LCOE* formulation by comparing LCOE calculated by the traditional vs. new method. We further provide a global analysis of LCOE* as an illustrative example. This LCOE* will accelerate new technology development (e.g. bifacial PV) by allowing a rapid and transparent analysis of its cost-performance trade-off.

14 SOLAR ENERGY↗

End-to-end Analytics for Grid Arch Design & All-hazard Assessment

Resiliency, reliability, and security of the next-generation smart grid depend upon leveraging advanced communication and computing technologies, integrating them with physical power systems, and developing real-time, fast, data-based applications to help in wide-area monitoring and control of the grid. Using a high sampling data rate from phasor measurement units (PMUs) to develop applications has opened the door to achieving the next-generation grid requirements. The North American Synchrophasor Initiative Network (NASPlnet) was developed in 2007-09 to create a standard and guide for PMU data exchanges. With the advancement in both networking and grid requirements, it is necessary to evaluate the performance of different NASPInet versions and their impact on applications. Therefore, we need a cyber-power cosimulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents a cyber-physical co-simulation testbed using NS3 to model the communication network, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application based on PMU data in an Institute of Electrical and Electronics Engineers 39-bus test system is presented using this co-simulation testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computational Fluid Dynamics (CFD) Analysis Of Optical Payload For Lasercomm Science (OPALS) sealed enclosure module

Computational Fluid Dynamics (CFD) using the commercial CFD package CFDesign has been performed at NASA Jet Propulsion Laboratory (JPL) California Institute of Technology (Caltech) in support of the Phaeton Early Career Hire Program's Optical Payload for Lasercomm Science (OPALS) mission. The OPALS project is one which involves an International Space Station payload that will be using forced convection cooling in a hermetically sealed enclosure at 1 atm of air to cool "off-the-shelf" vendor electronics. The CFD analysis was used to characterize the thermal and fluid flow environment within a complicated labyrinth of electronics boards, fans, instrumentation, harnessing, ductwork and heat exchanger fins. The paradigm of iteratively using CAD/CAE tools and CFD was followed in order to determine the optimum flow geometry and heat sink configuration to yield operational convective film coefficients and temperature survivability limits for the electronics payload. Results from this current CFD analysis and correlation of the CFD model against thermal test data will be presented. Lessons learned and coupled thermal / flow modeling strategies will be shared in this paper.

Computational Fluid Dynamics (CFD)↗

Baseline Testing of Ultracapacitors for the Next Generation Launch Technology (NGLT) Project

The NASA John H. Glenn Research Center initiated baseline testing of ultracapacitors for the Next Generation Launch Transportation (NGLT) project to obtain empirical data for determining the feasibility of using ultracapacitors for the project. There are large transient loads associated with NGLT that require either a very large primary energy source or an energy storage system. The primary power source used for these tests is a proton exchange membrane (PEM) fuel cell. The energy storage system can consist of devices such as batteries, flywheels, or ultracapacitors. Ultracapacitors were used for these tests. Ultracapacitors are ideal for applications such as NGLT where long life, maintenance-free operation, and excellent low-temperature performance is essential. State-of-the-art symmetric ultracapacitors were used for these tests. The ultracapacitors were interconnected in an innovative configuration to minimize interconnection impedance. PEM fuel cells provide excellent energy density, but not good power density. Ultracapacitors provide excellent power density, but not good energy density. The combination of PEM fuel cells and ultracapacitors provides a power source with excellent energy density and power density. The life of PEM fuel cells is shortened significantly by large transient loads. Ultracapacitors used in conjunction with PEM fuel cells reduce the transient loads applied to the fuel cell, and thus appreciably improves its life. PEM fuel cells were tested with and without ultracapacitors, to determine the benefits of ultracapacitors. The report concludes that the implementation of symmetric ultracapacitors in the NGLT power system can provide significant improvements in power system performance and reliability.

Eichenberg, Dennis J.↗

Baseline Testing of Ultracapacitors for the Next Generation Launch Technology (NGLT) Project

The NASA John H. Glenn Research Center initiated baseline testing of ultracapacitors for the Next Generation Launch Transportation (NGLT) project to obtain empirical data for determining the feasibility of using ultracapacitors for the project. There are large transient loads associated with NGLT that require either a very large primary energy source or an energy storage system. The primary power source used for these tests is a proton exchange membrane (PEM) fuel cell. The energy storage system can consist of devices such as batteries, flywheels, or ultracapacitors. Ultracapacitors were used for these tests. Ultracapacitors are ideal for applications such as NGLT where long life, maintenance-free operation, and excellent low-temperature performance is essential. State-of-the-art symmetric ultracapacitors were used for these tests. The ultracapacitors were interconnected in an innovative configuration to minimize interconnection impedance. PEM fuel cells provide excellent energy density, but not good power density. Ultracapacitors provide excellent power density, but not good energy density. The combination of PEM fuel cells and ultracapacitors provides a power source with excellent energy density and power density. The life of PEM fuel cells is shortened significantly by large transient loads. Ultracapacitors used in conjunction with PEM fuel cells reduce the transient loads applied to the fuel cell, and thus appreciably improves its life. PEM fuel cells were tested with and without ultracapacitors, to determine the benefits of ultracapacitors. The report concludes that the implementation of symmetric ultracapacitors in the NGLT power system can provide significant improvements in power system performance and reliability.

Eichenberg, Dennis J.↗

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗

Xerogel-Derived Ni Electrocatalysts for the Hydrogen Evolution Reaction in Alkaline Media

Anion exchange membrane water electrolyzers (AEMWEs) represent a promising technology for hydrogen production. The big advantage of the technology is that it allows for the use of platinum group metal-free (PGM-free) electrocatalysts at both electrodes, including catalysts for the hydrogen evolution reaction (HER) at the cathode. In addition to fulfilling the cost requirement, PGM-free HER catalysts need to meet the activity and durability targets of the AEMWEs. Here, in this work, we developed several carbon-supported, xerogel-derived nickel (Ni) HER electrocatalysts and evaluated the effect of various synthesis conditions, such as the type of carbon support, Ni-to-carbon ratio, and heat-treatment temperature and time, on their performance. Scanning transmission electron microscopy combined with energy-dispersive X-ray spectroscopy (STEM-EDS), X-ray diffraction spectroscopy (XRD), and X-ray photoelectron spectroscopy (XPS) revealed the formation of Ni nanoparticles with an oxygen-rich layer on the outside. Durability of the best-performing catalyst was assessed via a constant-current hold at 10 mA cm –2 over 100 h. This catalyst was found to be more active and durable than the reference PGM-free material, a commercial Ni catalyst supported on a Vulcan XC-72. The catalyst was also tested in the cathode of a fully PGM-free AEMWE, allowing to reach 1.90 V (1.84 V HFR-free) at 1 A cm –2 at 80 °C.

08 HYDROGEN↗