Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEST METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

ASTM E399 Standard Development - KIsi Analysis Method

The ASTM E399 test method is used to determine the plane‐strain fracture toughness, K (sub IC), for metallic materials. The test consists of monotonically loading a pre-cracked test specimen to failure while recording the applied load and the crack mouth opening displacement. Several test specimen types are allowable per ASTM E399; two common geometries are the compact tension (C(T)) and the single-edge bend (SE(B)) geometries. The test result is an estimate of the plane‐strain fracture toughness, K (sub q), determined by the intercept of the test record with a 95 percent secant-offset construction line. The 95 percent offset represents crack extension corresponding to approximately 2 percent of the original specimen ligament (assuming that all compliance change is the result of crack extension). If the test meets certain validity requirements based on specimen size and test behavior, the result is valid, and K (sub q) equals K (sub IC).

Tilson, William G.↗

HOST GALAXY IDENTIFICATION FOR SUPERNOVA SURVEYS

Host galaxy identification is a crucial step for modern supernova (SN) surveys such as the Dark Energy Survey and the Large Synoptic Survey Telescope, which will discover SNe by the thousands. Spectroscopic resources are limited, and so in the absence of real-time SN spectra these surveys must rely on host galaxy spectra to obtain accurate redshifts for the Hubble diagram and to improve photometric classification of SNe. In addition, SN luminosities are known to correlate with host-galaxy properties. Therefore, reliable identification of host galaxies is essential for cosmology and SN science. We simulate SN events and their locations within their host galaxies to develop and test methods for matching SNe to their hosts. We use both real and simulated galaxy catalog data from the Advanced Camera for Surveys General Catalog and MICECATv2.0, respectively. We also incorporate “hostless” SNe residing in undetected faint hosts into our analysis, with an assumed hostless rate of 5%. Our fully automated algorithm is run on catalog data and matches SNe to their hosts with 91% accuracy. We find that including a machine learning component, run after the initial matching algorithm, improves the accuracy (purity) of the matching to 97% with a 2% cost in efficiency (true positive rate). Although the exact results are dependent on the details of the survey and the galaxy catalogs used, the method of identifying host galaxies we outline here can be applied to any transient survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Uptakes of Cs and Sr on San Joaquin soil measured following ASTM method C1733

Series of tests were conducted following ASTM Standard Procedure C1733 to evaluate the repeatability of the test and the effects of several test parameters, including the solution-to-soil mass ratio, test duration, pH, and the concentrations of contaminants in the solution. This standard procedure is recommended for measuring the distribution coefficient (K d ) of a contaminant in a specific soil/groundwater system. One objective of the current tests was to identify experimental conditions that can be used in future interlaboratory studies to determine the reproducibility of the test method. This includes the recommendation of a standard soil, the range of contaminant concentrations and solution matrix, and various test parameters. Quantifying the uncertainty in the distribution coefficient that can be attributed to the test procedure itself allows the differences in measured values to be associated with differences in the natural systems being studied.

54 ENVIRONMENTAL SCIENCES↗

Specification of pyro shock tests

Specifications of pyro shock tests are treated as the interconnection between raw measurements (or estimates) of the environment and the various test methods available. After a definition of the environment, various aspects of test method specification are discussed including one-sided pulses, test simulation parameters, and the effects of Q. Different test configurations are considered including rigid fixture tests, pseudo-real structure, and real structure.

Trummel, M.↗

DROP DURABILITY ASSESSMENT OF ELECTRONIC ASSEMBLIES UNDER OFF-AXIS LOADING WITH SKEWED FIXTURES

This thesis studies drop durability of electronic assemblies when the acceleration vector is oriented at 45° to the out-of-plane direction of the circuit card. The off-axis drop tests are accomplished with a skewed fixture and are conducted as a proxy for multiaxial drop testing. Advanced shock testing and vibration test methods have been developed over the last few decades to better represent real-world field environments during ground-based laboratory testing. However, many of these test methods require expensive and specialized equipment not available in most laboratories. An alternative approach for approximating simultaneous loading along multiple axes on conventional equipment utilizes skewed fixtures which have seen use in off-axis random vibration and drop impact testing. These methods generally rely on the conversion of a uniaxial input load from the test equipment (using a uniaxial drop tower or shaker) into a multiaxial load when resolved in the reference frame of the test article (mounted on a skewed fixture). Skewed fixture design is presented and recommendations for conducting skewed angle drop testing are introduced based on local measurements along the skewed face of the fixture to accurately monitor the impact event. Characterization tests were performed with a skewed fixture, at simultaneous acceleration loads from 500 to 3,000 g in two (in-plane and out-of-plane) directions, while meeting standard time domain tolerances. Upon experimental characterization, drop shock durability tests were conducted on a printed circuit assembly (PCA). Mean drops-to-failure were measured and quantified with Weibull statistics. Dominant solder joint failure modes were identified via failure analysis. Prior work on inclined angle impact testing is limited, and the majority of solder joint interconnect level fatigue studies are conducted considering perpendicular loading normal the circuit card. Low-cycle fatigue curves are generated based on plastic strain and plastic work density within the solder joint. A multiscale nonlinear finite element model is used to relate board-level flexure to solder joint interconnect level plastic strain. A high strain rate solder constitutive model allows for accurate modeling of solder plasticity resulting from high-impact drop shock. Fatigue parameters are computed from the Coffin-Manson relation and Palmgren-Miner damage accumulation. This work serves to apply established low-cycle fatigue methods for conventional drop shock loading (impact normal to circuit card) to non-perpendicular loading with a skewed fixture.

Hower, Jonathan [Kansas City National Security Cam↗

Preliminary study of nuclear fuel element testing based on coded source neutron imaging

Neutron radiography (NR) is one of the most important nondestructive testing methods, which is sensitive to low density materials. Especially, Neutron transfer imaging method could be used to test radioactivity materials refraining from γ effect, but it is difficult to realize tomography. Coded source neutron imaging (CSNI) is a newly NR method developed fast in the last several years. The distance between object and detector is much longer than traditional NR, which could be used to test radioactivity materials. With pre-reconstruction process from fold-cover projections, CSNI could easily realize tomography. This thesis carries out preliminary study on the nuclear fuel element testing by coded source neutron imaging. We calculate different enrichment, flaws and activity in nuclear fuel elements tested by CSNI with Monte-Carlo simulation. The results show that CSNI could be a useful testing method for nuclear fuel element testing. (authors)

42 ENGINEERING↗

Battery Test Manual For 48 Volt Mild Hybrid Electric Vehicles

This manual details the U.S. Advanced Battery Consortium and U.S. Department of Energy Vehicle Technologies Program goals, test methods, and analysis techniques for a 48 Volt Mild Hybrid Electric Vehicle system. The test methods are outlined stating with characterization tests, followed by life tests. The final section details standardized analysis techniques for 48 V systems that allow for the comparison of different programs that use this manual. An example test plan is included, along with guidance to filling in gap table numbers.

33 ADVANCED PROPULSION SYSTEMS↗

Directly Probing the Fracture Behavior of Ultrathin Polymeric Films

Understanding fracture mechanics of ultrathin polymeric films is crucial for modern technologies, including semiconductor and coating industries. However, up to now, the fracture behavior of sub-100 nm polymeric thin films is rarely explored due to challenges in handling samples and limited testing methods available. In this work, we report a new testing methodology that can not only visualize the evolution of the local stress distribution through wrinkling patterns and crack propagation during the deformation of ultrathin films but also directly measure their fracture energies. Using ultrathin polystyrene films as a model system, we both experimentally and computationally investigate the effect of the film thickness and molecular weight on their fracture behavior, both of which show a ductile-to-brittle transition. Furthermore, we demonstrate the broad applicability of this testing method in semicrystalline semiconducting polymers. We anticipate our methodology described here could provide new ways of studying the fracture behavior of ultrathin films under confinement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NASA Electronic Parts and Packaging (NEPP) Program

Recent Findings from Audits, New Technology Data Reviews a) Disabled Chip Burn-ins A recent audit for a QML device discovered that the chip was disabled during the static burn-in, thus it was not drawing any current. Recommendation: For new SMDs add a statement within the burn-in paragraphs stating that the parts shall be kept in their enabled state during the burn-in. b) Class Q 160-hr/125oC Burn-in This is being interpreted as a static burn-in (even for CMOS technology). Recommendation: Provide clarification in MIL-STD-883, Test Method 5004. c) At Frequency (Dynamic) Burn-ins Test equipment limitation is being cited for not doing burn-ins at the application frequency. Recommendation: The burn-in task group to discuss and provide guidance. When the SMD says that the part can be used at 200 MHz, then doing burn-in at 6 MHz (cited as burn-in equipment limitation frequency) is not going to be meaningful! d) Two Static Burn-ins Some manufacturers are doing electrical testing between the two static burn-ins, whereas others do electricals after completing both static burn-ins. Recommendation: Provide clarification in MIL-STD-883, Test Method 5004. e) Thermal Imaging For a device with hot spots, the thermal resistance, junction-to-case, would be much higher than the guidelines given in MIL-STD-1835. One of the suppliers used thermal imaging to find hot spots on the die. Recommendation: Assign a task group to evaluate the effectiveness of thermal imaging at the product development stage.

Class Y↗

Impact of Biodiesel Impurities on the Performance and Durability of DOC, DPF and SCR Technologies

It is estimated that operating continuously on a B20 fuel containing the current allowable ASTM specification limits for metal impurities in biodiesel could result in a doubling of ash exposure relative to lube-oil derived ash. The purpose of this study was to determine if a fuel containing metals at the ASTM limits could cause adverse impacts on the performance and durability of diesel emission control systems. An accelerated durability test method was developed to determine the potential impact of these biodiesel impurities. The test program included engine testing with multiple DPF substrate types as well as DOC and SCR catalysts. The results showed no significant degradation in the thermo-mechanical properties of cordierite, aluminum titanate, or silicon carbide DPFs after exposure to 150,000 mile equivalent biodiesel ash and thermal aging. However, exposure of a cordierite DPF to 435,000 mile equivalent aging resulted in a 69% decrease in the thermal shock resistance parameter. It is estimated that the additional ash from 150,000 miles of biodiesel use would also result in a moderate increases in exhaust backpressure for a DPF. A decrease in DOC activity was seen after exposure to 150,000 mile equivalent aging, resulting in higher HC slip and a reduction in NO{sub 2} formation. The metal-zeolite SCR catalyst experienced a slight loss in activity after exposure to 435,000 mile equivalent aging. This catalyst, placed downstream of the DPF, showed a 5% reduction in overall NOx conversion activity over the HDDT test cycle.

09 BIOMASS FUELS↗

Board Level Proton Testing Book of Knowledge for NASA Electronic Parts and Packaging Program

This book of knowledge (BoK) provides a critical review of the benefits and difficulties associated with using proton irradiation as a means of exploring the radiation hardness of commercial-off-the-shelf (COTS) systems. This work was developed for the NASA Electronic Parts and Packaging (NEPP) Board Level Testing for the COTS task. The fundamental findings of this BoK are the following. The board-level test method can reduce the worst case estimate for a board's single-event effect (SEE) sensitivity compared to the case of no test data, but only by a factor of ten. The estimated worst case rate of failure for untested boards is about 0.1 SEE/board-day. By employing the use of protons with energies near or above 200 MeV, this rate can be safely reduced to 0.01 SEE/board-day, with only those SEEs with deep charge collection mechanisms rising this high. For general SEEs, such as static random-access memory (SRAM) upsets, single-event transients (SETs), single-event gate ruptures (SEGRs), and similar cases where the relevant charge collection depth is less than 10 μm, the worst case rate for SEE is below 0.001 SEE/board-day. Note that these bounds assume that no SEEs are observed during testing. When SEEs are observed during testing, the board-level test method can establish a reliable event rate in some orbits, though all established rates will be at or above 0.001 SEE/board-day. The board-level test approach we explore has picked up support as a radiation hardness assurance technique over the last twenty years. The approach originally was used to provide a very limited verification of the suitability of low cost assemblies to be used in the very benign environment of the International Space Station (ISS), in limited reliability applications. Recently the method has been gaining popularity as a way to establish a minimum level of SEE performance of systems that require somewhat higher reliability performance than previous applications. This sort of application of the method suggests a critical analysis of the method is in order. This is also of current consideration because the primary facility used for this type of work, the Indiana University Cyclotron Facility (IUCF) (also known as the Integrated Science and Technology (ISAT) hall), has closed permanently, and the future selection of alternate test facilities is critically important. This document reviews the main theoretical work on proton testing of assemblies over the last twenty years. It augments this with review of reported data generated from the method and other data that applies to the limitations of the proton board-level test approach. When protons are incident on a system for test they can produce spallation reactions. From these reactions, secondary particles with linear energy transfers (LETs) significantly higher than the incident protons can be produced. These secondary particles, together with the protons, can simulate a subset of the space environment for particles capable of inducing single event effects (SEEs). The proton board-level test approach has been used to bound SEE rates, establishing a maximum possible SEE rate that a test article may exhibit in space. This bound is not particularly useful in many cases because the bound is quite loose. We discuss the established limit that the proton board-level test approach leaves us with. The remaining possible SEE rates may be as high as one per ten years for most devices. The situation is actually more problematic for many SEE types with deep charge collection. In cases with these SEEs, the limits set by the proton board-level test can be on the order of one per 100 days. Because of the limited nature of the bounds established by proton testing alone, it is possible that tested devices will have actual SEE sensitivity that is very low (e.g., fewer than one event in 1 × 10(exp 4) years), but the test method will only be able to establish the limits indicated above. This BoK further examines other benefits of proton board-level testing besides hardness assurance. The primary alternate use is the injection of errors. Error injection, or fault injection, is something that is often done in a simulation environment. But the proton beam has the benefit of injecting the majority of actual SEEs without risk of something being missed, and without the risk of simulation artifacts misleading the SEE investigation.

Guertin, Steven M.↗

Methodology for Mechanical Property Testing of Fuel Cladding Using a Expanded Plug Wedge Test

An expanded plug method was developed earlier for determining the tensile properties of irradiated fuel cladding. This method tests fuel rod cladding ductility by utilizing an expandable plug to radially stretch a small ring of irradiated cladding material. The circumferential or hoop strain is determined from the measured diametrical expansion of the ring. A developed procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves, from which material properties of the cladding can be extracted. However, several deficiencies existed in this expanded-plug test that can impact the accuracy of test results, such as that the large axial compressive stress resulted from the expansion plug test can potentially induce the shear failure mode of the tested specimen. Moreover, highly nonuniform stress and strain distribution in the deformed clad gage section and significant compressive stresses, induced by bending deformation due to clad bulging effect, will further result in highly nonconservative estimates of the mechanical properties for both strength and ductility of the tested clad. To overcome the aforementioned deficiencies associated with the current expansion plug test, systematic studies have been conducted. By optimizing the specific geometry designs, selecting the appropriate material for the expansion plug, and adding new components into the testing system, a modified expansion plug testing protocol has been developed. A general procedure was also developed to determine the hoop stress in the tested ring specimen. A scaling factor, -factor, was used to convert the ring load Fring into hoop stress , and is written as _ = F_ring/tl , where t is the clad thickness and l is the clad length. The generated stress-strain curve agrees well with the associated tensile test data in both elastic and plastic deformation regions.

expansion plug test↗

Good Enough for the X-38, but Made for Commercial Aircraft

Aircraft Belts, Inc. (ABI), of Kemah, Texas, was looking for a way to ensure the safety of its customers by developing a thorough test system for aviation restraint systems. Previous safety restraint test methods did not properly measure the load distribution placed on the restraints, leaving an unknown factor in meeting safety standards. ABI needed to improve its testing methods and update its test equipment. Through a partnership with NASA's Johnson Space Center Technical Outreach Program, the need was met. With the assistance of NASA engineers, ABI developed a hydraulic test system that provides the consumer with in-depth data about the load placed on the restraint system throughout the duration of the test. The old systems were only able to detect if the belts could sustain the applied force and could not target the problem of providing load data. In comparison, the new system modeled after the one used by NASA, can collect data that tells exactly what went wrong with belts that break and why. Depending on the test requirements of various restraint components, the system can exert a subjected force ranging from merely a few pounds to thousands. The test force can be applied to an entire safety restraint system or to its individual parts, including, stitching, webbing, and hardware.

Source record↗

Investigating {sup 13}C+{sup 12}C reaction by the activation method. Sensitivity tests

We have performed experiments to check the limits of sensitivity of the activation method using the new 3 MV Tandetron accelerator and the low and ultra-low background laboratories of the “Horia Hulubei” National Institute of Physics and Nuclear Engineering (IFIN-HH). We have used the {sup 12}C+{sup 13}C reaction at beam energies E{sub lab}= 6, 7 and 8 MeV. The knowledge of this fusion cross section at deep sub-barrier energies is of interest for astrophysical applications, as it provides an upper limit for the fusion cross section of {sup 12}C+{sup 12}C over a wide energy range. A {sup 13}C beam with intensities 0.5–2 particleμA was provided by the accelerator and used to bombard graphite targets, resulting in activation with {sup 24}Na from the {sup 12}C({sup 13}C,p) reaction. The 1369 and 2754 keV gamma-rays from {sup 24}Na de-activation were clearly observed in the spectra obtained in two different laboratories used for measurements at low and ultralow background: one at the surface and one located underground in the Unirea salt mine from Slanic Prahova, Romania. In the underground laboratory, for E{sub lab} = 6 MeV we have measured an activity of 0.085 ± 0.011 Bq, corresponding to cross sections of 1–3 nb. This demonstrates that it is possible to measure {sup 12}C targets irradiated at lower energies for at least 10 times lower cross sections than before β–γ coincidences will lead us another factor of 10 lower, proving that this installations can be successfully used for nuclear astrophysics measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of Water Content in Bio-Oils by Volumetric Karl Fischer Titration: Laboratory Analytical Procedure (LAP)

The water content of bio-oils is a key metric for several reasons. Water is typically the most concentrated single component of fast pyrolysis oils, though this will be much lower in catalytic fast pyrolysis and upgraded products. Reduced water content is preferable in bio-oil as water can contribute to phase separation, corrosivity, and instability. Additionally, lower water is beneficial for physical properties such as energy density. The percentage of water can also be used to correct the calculation for organic oxygen when determining total oxygen content of bio-oils via combustion-based ultimate analysis. The procedure described here is specifically written for the analysis of bio-oils, and is based on ASTM E203, Standard Test Method for Water Using Volumetric Karl Fischer Titration. This standard test method is specified for measuring the mass % water in pyrolysis liquid biofuels in ASTM D7544, Standard Specification for Pyrolysis Liquid Biofuel. Although the standard method is prescribed for the analysis of pyrolysis liquids for use in industrial and commercial burners, the method is not specifically written for this product. The method described with this Laboratory Analytical Procedure (LAP) provides specific guidance for the analysis of bio-oils. Both organic and aqueous phases can be measured with this technique.

09 BIOMASS FUELS↗

A novel method of testing the shear strength of thick honeycomb composites

Sandwich composites of aluminum and glass/phenolic honeycomb core were tested for shear strength before and after impact damage. The assessment of shear strength was performed in two ways; by four point bend testing of sandwich beams and by a novel double lap shear (DLS) test. This testing technique was developed so smaller specimens could be used, thus making the use of common lab scale fabrication and testing possible. The two techniques yielded similar data. The DLS test gave slightly lower shear strength values of the two methods but were closer to the supplier's values for shear strength.

Hodge, A. J.↗

A practical method to test the validity of the standard Gumbel distribution in logit-based multinomial choice models of travel behavior

Most multinomial choice models (e.g., the multinomial logit model) adopted in practice assume an extreme-value Gumbel distribution for the random components (error terms) of utility functions. This distributional assumption offers a closed-form likelihood expression when the utility maximization principle is applied to model choice behaviors. As a result, model coefficients can be easily estimated using the standard maximum likelihood estimation method. However, maximum likelihood estimators are consistent and efficient only if distributional assumptions on the random error terms are valid. It is therefore critical to test the validity of underlying distributional assumptions on the error terms that form the basis of parameter estimation and policy evaluation. In this paper, a practical yet statistically rigorous method is proposed to test the validity of the distributional assumption on the random components of utility functions in both the multinomial logit (MNL) model and multiple discrete-continuous extreme value (MDCEV) model. Based on a semi-nonparametric approach, a closed-form likelihood function that nests the MNL or MDCEV model being tested is derived. The proposed method allows traditional likelihood ratio tests to be used to test violations of the standard Gumbel distribution assumption. Simulation experiments are conducted to demonstrate that the proposed test yields acceptable Type-I and Type-II error probabilities at commonly available sample sizes. The test is then applied to three real-world discrete and discrete-continuous choice models. For all three models, the proposed test rejects the validity of the standard Gumbel distribution in most utility functions, calling for the development of robust choice models that overcome adverse effects of violations of distributional assumptions on the error terms in random utility functions.

30 DIRECT ENERGY CONVERSION↗

Relative toxicity of products of pyrolysis and combustion of polymeric materials using various test conditions

Relative toxicity data for a large number of natural and synthetic polymeric materials are presented which were obtained by 11 pyrolysis and three flaming-combustion test methods. The materials tested include flexible and rigid polyurethane foams, different kinds of fabrics and woods, and a variety of commodity polymers such as polyethylene. Animal exposure chambers of different volumes containing mice, rats, or rabbits were used in the tests, which were performed over the temperature range from ambient to 800 C with and without air flow or recirculation. The test results are found to be sensitive to such variables as exposure mode, temperature, air flow and dilution, material concentration, and animal species, but relative toxicity rankings appear to be similar for many methods and materials. It is concluded that times to incapacitance and to death provide a more suitable basis for relative toxicity rankings than percent mortality alone, that temperature is the most important variable in the tests reported, and that variables such as chamber volume and animal species may not significantly affect the rankings.

Hilado, C. J.↗