Tank Applied Testing of Load-Bearing Multilayer Insulation (LB-MLI)

The development of long duration orbital cryogenic storage systems will require the reduction of heat loads into the storage tank. In the case of liquid hydrogen, complete elimination of the heat load at 20 K is currently impractical due to the limitations in lift available on flight cryocoolers. In order to reduce the heat load, without having to remove heat at 20 K, the concept of Reduced Boil-Off uses cooled shields within the insulation system at approximately 90 K. The development of Load-Bearing Multilayer Insulation (LB-MLI) allowed the 90 K shield with tubing and cryocooler attachments to be suspended within the MLI and still be structurally stable. Coupon testing, both thermal and structural was performed to verify that the LB-MLI should work at the tank applied level. Then tank applied thermal and structural (acoustic) testing was performed to demonstrate the functionality of the LB-MLI as a structural insulation system. The LB-MLI showed no degradation of thermal performance due to the acoustic testing and showed excellent thermal performance when integrated with a 90 K class cryocooler on a liquid hydrogen tank.

Thermal Insulation↗

Tank Applied Testing of Load-Bearing Multilayer Insulation (LB-MLI)

The development of long duration orbital cryogenic storage systems will require the reduction of heat loads into the storage tank. In the case of liquid hydrogen, complete elimination of the heat load at 20 K is currently impractical due to the limitations in lift available on flight cryocoolers. In order to reduce the heat load, without having to remove heat at 20 K, the concept of Reduced Boil-Off uses cooled shields within the insulation system at approximately 90 K. The development of Load-Bearing Multilayer Insulation (LB-MLI) allowed the 90 K shield with tubing and cryocooler attachments to be suspended within the MLI and still be structurally stable. Coupon testing both thermally and structurally were performed to verify that the LB-MLI should work at the tank applied level. Then tank applied thermal and structural (acoustic) testing was performed to demonstrate the functionality of the LB-MLI as a structural insulation system. The LB-MLI showed no degradation of thermal performance due to the acoustic testing and showed excellent thermal performance when integrated with a 90 K class cryocooler on a liquid hydrogen tank.

Space Environment Simulation↗

Validation of a Computational Model for the SLS Core Stage Oxygen Tank Diffuser Concept and the Low Profile Diffuser - An Advanced Development Design for the SLS

The Low Profile Diffuser (LPD) project originated as an award from the Marshall Space Flight Center (MSFC) Advanced Development (ADO) office to the Main Propulsion Systems Branch (ER22). The task was created to develop and test an LPD concept that could produce comparable performance to a larger, traditionally designed, ullage gas diffuser while occupying a smaller volume envelope. Historically, ullage gas diffusers have been large, bulky devices that occupy a significant portion of the propellant tank, decreasing the tank volume available for propellant. Ullage pressurization of spacecraft propellant tanks is required to prevent boil-off of cryogenic propellants and to provide a positive pressure for propellant extraction. To achieve this, ullage gas diffusers must slow hot, high-pressure gas entering a propellant tank from supersonic speeds to only a few meters per second. Decreasing the incoming gas velocity is typically accomplished through expansion to larger areas within the diffuser which has traditionally led to large diffuser lengths. The Fluid Dynamics Branch (ER42) developed and applied advanced Computational Fluid Dynamics (CFD) analysis methods in order to mature the LPD design from and initial concept to an optimized test prototype and to provide extremely accurate pre-test predictions of diffuser performance. Additionally, the diffuser concept for the Core Stage of the Space Launch System (SLS) was analyzed in a short amount of time to guide test data collection efforts of the qualification of the device. CFD analysis of the SLS diffuser design provided new insights into the functioning of the device and was qualitatively validated against hot wire anemometry of the exterior flow field. Rigorous data analysis of the measurements was performed on static and dynamic pressure data, data from two microphones, accelerometers and hot wire anemometry with automated traverse. Feasibility of the LPD concept and validation of the computational model were demonstrated by the test data.

Brodnick, Jacob↗

The Safe Removal of Frozen Air from the Annulus of an LH2 Storage Tank

Large Liquid Hydrogen (LH2) storage tanks are vital infrastructure for NASA. Eventually, air may leak into the evacuated and perlite filled annular region of these tanks. Although the vacuum level is monitored in this region, the extremely cold temperature causes all but the helium and neon constituents of air to freeze. A small, often unnoticeable pressure rise is the result. As the leak persists, the quantity of frozen air increases, as does the thermal conductivity of the insulation system. Consequently, a notable increase in commodity boil-off is often the first indicator of an air leak. Severe damage can result from normal draining of the tank. The warming air will sublimate which will cause a pressure rise in the annulus. When the pressure increases above the triple point, the frozen air will begin to melt and migrate downward. Collection of liquid air on the carbon steel outer shell may chill it below its ductility range, resulting in fracture. In order to avoid a structural failure, as described above, a method for the safe removal of frozen air is needed. A thermal model of the storage tank has been created using SINDA/FLUINT modeling software. Experimental work is progressing in an attempt to characterize the thermal conductivity of a perlite/frozen nitrogen mixture. A statistical mechanics model is being developed in parallel for comparison to experimental work. The thermal model will be updated using the experimental/statistical mechanical data, and used to simulate potential removal scenarios. This paper will address methodologies and analysis techniques for evaluation of two proposed air removal methods.

cryogenic insulation↗

Determination of Liquid/Gas Interface and Liquid Center of Gravity for GPM Tank with PMD Using Surface Evolver

Many spacecraft, such as the Global Precipitation Mission (GPM) spacecraft, use propellant management devices (PMDs) to control liquid propellant within propellant tanks. Surface Evolver, an energy minimization routine, is used to find liquid-gas interface shapes due to surface tension and propellant center of mass locations for varying initial liquid positions, contact angles, and fill fractions for the GPM tank with a PMD. This study shows that Surface Evolver can accurately model the liquid-gas interface and liquid center of mass location for a complicated tank and PMD. The Surface Evolver results show that the initial position of the propellant, the contact angle between the propellant and solid surfaces, and the fill fraction of the propellant can drastically affect the liquid-gas interface in the tank and thus the center of mass of the propellant.

Benson, David J.↗

Numerical Modeling of Pressurization of Cryogenic Propellant Tank for Integrated Vehicle Fluid System

This paper presents a numerical model of pressurization of a cryogenic propellant tank for the Integrated Vehicle Fluid (IVF) system using the Generalized Fluid System Simulation Program (GFSSP). The IVF propulsion system, being developed by United Launch Alliance, uses boiloff propellants to drive thrusters for the reaction control system as well as to run internal combustion engines to develop power and drive compressors to pressurize propellant tanks. NASA Marshall Space Flight Center (MSFC) has been running tests to verify the functioning of the IVF system using a flight tank. GFSSP, a finite volume based flow network analysis software developed at MSFC, has been used to develop an integrated model of the tank and the pressurization system. This paper presents an iterative algorithm for converging the interface boundary conditions between different component models of a large system model. The model results have been compared with test data.

Majumdar, Alok K.↗

The Zero Boil-Off Tank Experiment Ground Testing and Verification of Fluid and Thermal Performance

The Zero Boil-Off Technology (ZBOT) Experiment involves performing a small scale International Space Station (ISS) experiment to study tank pressurization and pressure control in microgravity. The ZBOT experiment consists of a vacuum jacketed test tank filled with an inert fluorocarbon simulant liquid. Heaters and thermo-electric coolers are used in conjunction with an axial jet mixer flow loop to study a range of thermal conditions within the tank. The objective is to provide a high quality database of low gravity fluid motions and thermal transients which will be used to validate Computational Fluid Dynamic (CFD) modeling. This CFD can then be used in turn to predict behavior in larger systems with cryogens. This paper will discuss the work that has been done to demonstrate that the ZBOT experiment is capable of performing the functions required to produce a meaningful and accurate results, prior to its launch to the International Space Station. Main systems discussed are expected to include the thermal control system, the optical imaging system, and the tank filling system.This work is sponsored by NASAs Human Exploration Mission Directorates Physical Sciences Research program.

Fluid management↗

Modeling of Gaseous Oxygen Liquefaction Inside Mars Ascent Vehicle Propellant Tank

The In-Situ production of propellants for Mars missions has been considered to utilize the Carbon dioxide (CO2) in Mars atmosphere to produce Oxygen using a high temperature solid oxide electrolyzer. The oxygen then needs to be cooled, liquefied, and stored to be available for propulsion and other end users. The storage period could be up to two years either in the actual Mars ascent propulsion tanks or in a separate tank. Recent investigations have demonstrated the feasibility of both achieving zero-boil-off and controlling the pressure of oxygen within a tank using high efficiency cryocoolers. A representative configuration of tube on tank liquefaction using cryocooler is shown in Fig. 1.

Cryogenic fluids↗

Zero Boil-Off Methods for Large Scale Liquid Hydrogen Tanks Using Integrated Refrigeration and Storage

NASA has completed a series of tests at the Kennedy Space Center to demonstrate the capability of using integrated refrigeration and storage (IRAS) to remove energy from a liquid hydrogen (LH2) tank and control the state of the propellant. A primary test objective was the keeping and storing of the liquid in a zero boil-off state, so that the total heat leak entering the tank is removed by a cryogenic refrigerator with an internal heat exchanger. The LH2 is therefore stored and kept with zero losses for an indefinite period of time. The LH2 tank is a horizontal cylindrical geometry with a vacuum-jacketed, multi-layer insulation system and a capacity of 125,000 liters. The closed-loop helium refrigeration system was a Linde LR1620 capable of 390W cooling at 20K (without any liquid nitrogen pre-cooling). Three different control methods were used to obtain zero boil-off: temperature control of the helium refrigerant, refrigerator control using the tank pressure sensor, and duty cycling (on/off) of the refrigerator as needed. Summarized are the IRAS design approach, zero boil-off control methods, and results of the series of zero boil-off tests.

ZBO↗

Annular Air Leaks in a Liquid Hydrogen Storage Tank

Large liquid hydrogen (LH2) storage tanks are vital infrastructure for NASA, the DOD, and industrial users. Over time, air may leak into the evacuated, perlite filled annular region of these tanks. Once inside, the extremely low temperatures will cause most of the air to freeze. If a significant mass of air is allowed to accumulate, severe damage can result from nominal draining operations. Collection of liquid air on the outer shell may chill it below its ductility range, resulting in fracture. Testing and analysis to quantify the thermal conductivity of perlite that has nitrogen frozen into its interstitial spaces and to determine the void fraction of frozen nitrogen within a perlite-frozen nitrogen mixture is presented. General equations to evaluate methods for removing frozen air, while avoiding fracture, are developed. A hypothetical leak is imposed on an existing tank and a full analysis of that leak is detailed. This analysis includes a thermal model of the tank and a time-to-failure calculation. Approaches to safely remove the frozen air are analyzed, leading to the conclusion that the optimal approach is to allow the frozen air to melt and use a water stream to prevent the outer shell from chilling.

Krenn, A. G.↗

Multi-Node Modeling of Cryogenic Tank Pressurization System using Generalized Fluid System Simulation Program

This paper presents a multi-node model of autogenous pressurization of cryogenic propellant in a flight tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code developed at NASA/Marshall Space Flight Center. Tests were conducted to measure the pressure and temperatures at the various axial locations of the stratified ullage at 75% and 45% fill level. Liquid nitrogen was pressurized by gaseous nitrogen from a supply tank while the drain valve from the tank remained closed during the pressurization process. The ullage was discretized into 25 uniformly distributed nodes: 5 in the radial direction and 5 in the axial direction assuming the flow to be axisymmetric. Heat and mass transfer between the liquid and vapor has been modeled at the liquid vapor interface. Heat transfer between wall and vapor at the ullage has been accounted for by assuming heat transfer occurs by natural convection. The model also accounts for heat leak to the tank through the insulation and metal wall by heat conduction. The predicted pressures and temperatures are compared with the measured data.

Bandyopadhyay, Alak↗

CFD Jet Mixing Model Validation Against Zero-Boil-Off Tank (ZBOT) Microgravity Experiment

The Zero-Boil-Off Tank (ZBOT) experiments are a series of small scale two-phase fluids physics experiments conducted aboard the International Space Station (ISS) in 2017. A goal of these experiments is to study various fundamental fluid flow, heat and mass transport, and phase change phenomena that control storage tank pressurization and pressure control in microgravity. In this paper, results of a state-of-the-art two-phase CFD (Computational Fluid Dynamics) storage tank model are presented and validated against jet mixing data provided by microgravity ZBOT experiments. Jet-ullage interaction was studied in the experiment for different jet speeds representing different flow regimes, and tank fill levels. Effects of various physical parameters, such as, jet angle, gravitational acceleration and surface tension value were investigated. Computational parameters, such as turbulence and surface tension models and interface capturing scheme, affecting jet-ullage interaction were also studied. Computational results were compared to experimental results for model validation.

Turbulence↗

CFD Jet Mixing Model Validation against Zero-Boil-Off Tank (ZBOT) Microgravity Experiment

The Zero-Boil-Off Tank (ZBOT) experiments are a series of small scale two-phase fluids physics experiments conducted aboard the International Space Station (ISS) in 2017. A goal of these experiments is to study various fundamental fluid flow, heat and mass transport, and phase change phenomena that control storage tank pressurization and pressure control in microgravity. In this paper, results of a state-of-the-art two-phase CFD storage tank model are presented and validated against jet mixing data provided by microgravity ZBOT experiments. Jet-ullage interaction was studied in the experiment for different jet speeds representing different flow regimes, and tank fill levels. Effects of various physical parameters, such as, jet angle, gravitational acceleration and surface tension value were investigated. Computational parameters, such as turbulence and surface tension models and interface capturing scheme, affecting jet-ullage interaction were also studied. Computational results were compared to experimental results for model validation.

Mixing↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Autogenous Pressurization of a Cryogenic Tank Using Computational Fluid Dynamics

Well-validated simulation tools can be used to predict long-term storage and transfer of cryogenic propellants, which are essential to NASA’s mission plan to return to the Moon and continue to Mars. Autogenous pressurization of propellant tanks is used to supply rocket engine turbopumps with pressurized liquid fuel and oxidizer, preventing cavitation. Additionally, autogenous pressurization can be used to pressurize propellant tanks to support on-orbit propellant transfer. In lieu of expensive tests conducted on-orbit, accurate predictive computational models of these processes can be used to reduce system and propellant mass as well as mission risk. Using simulation tools also reduces the cost of analyzing and developing this technology. This study presents a multiphase computational fluid dynamics model capable of simulating autogenous pressurization of a large cryogenic tank using the commercial code STAR-CCM+. Experimental data from a full-scale tank pressurization test under terrestrial gravity is compared to simulation results using transient error metrics. Comparisons show good agreement and give confidence in using these and other validated simulation tools to develop cryogenic pressurization systems.

Cryogenics↗

Autogenous Pressurization of a Cryogenic Tank using Computational Fluid Dynamics

Well-validated simulation tools can be used to predict long-term storage and transfer of cryogenic propellants, which are essential to NASA’s mission plan to return to the Moon and continue to Mars. Autogenous pressurization of propellant tanks is used to supply rocket engine turbopumps with pressurized liquid fuel and oxidizer, preventing cavitation. Additionally, autogenous pressurization can be used to pressurize propellant tanks to support on-orbit propellant transfer. In lieu of expensive tests conducted on-orbit, accurate predictive computational models of these processes can be used to reduce system and propellant mass as well as mission risk. Using simulation tools also reduces the cost of analyzing and developing this technology. This study presents a multiphase computational fluid dynamics model capable of simulating autogenous pressurization of a large cryogenic tank using the commercial code STAR-CCM+. Experimental data from a full-scale tank pressurization test under terrestrial gravity is compared to simulation results using transient error metrics. Comparisons show good agreement and give confidence in using these and other validated simulation tools to develop cryogenic pressurization systems. Note: There is no audio file included or available for this presentation.

cryogenics↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

ABSTRACT: Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Validation of Cryogenic Propellant Tank Self-Pressurization by Leveraging Reduced Order Modeling within Computational Fluid Dynamics Simulation

Validation of cryogenic propellant tank self-pressurization was performed using a hybrid Computational Fluid Dynamics (CFD) and reduced order modeling methodology. Data from a liquid hydrogen ground test conducted at the K-site facility at the National Aeronautics and Space Administration (NASA) Glenn Research Center was used for the validation effort. Liquid phase dynamics were explicitly resolved with a CFD tool. Vapor phase dynamics were modeled as a point mass that communicated heat from the tank wall to the liquid phase via a boundary condition used at the gas-liquid interface. The method proved to be more accurate, robust, and efficient than explicit resolution of the dynamics using a standard Volume of Fluid (VOF) methodology. The subject pressurization process was found to be heavily dependent upon both the relatively high liquid temperature gradient near the gas-liquid interface and the natural convection flow path. Modeling the gas-liquid interface as an immovable surface eliminated temperature gradient destroying gas-liquid interface velocities observed in VOF simulations, and correspondingly enabled more rapid simulation since interface advection was not allowed. The single phase computational domain also facilitated the ability to demonstrate spatial resolution convergence of natural convection cells within the liquid which significantly impacted the tank pressurization rate. This work was used to demonstrate the critical physics for tank self-pressurization and numerical methodologies that may be used to best resolve those physics. The findings informed development and operation of production level CFD tools used in the Fluid Dynamics Branch at NASA Marshall Space Flight Center.

J. M. Brodnick↗