Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Synchrotrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Fibroma induction in rat skin following single or multiple doses of 1.0 GeV/nucleon 56Fe ions from the Brookhaven Alternating Gradient Synchrotron (AGS)

Rat skin was exposed to the plateau region of the 1.0 GeV/nucleon 56Fe beam at the Brookhaven AGS. Rats were irradiated or not with single of split doses of 56Fe or argon; some 56Fe-exposed rats were fed 250 ppm retinyl acetate continuously in the lab chow beginning 1 week before irradiation. All lesions were noted, photographed and identified for eventual histological diagnosis. The preponderance of the tumors so far are fibromas. The data show that single doses of 56Fe ions are 2 or 3 fold more effective than argon in producing tumors at 4.5 Gy but are about equally effective at 3.0 Gy and 9.0 Gy. The presence of 250 ppm retinyl acetate in the lab chow reduced the incidence of tumors by about 50-60% in comparison to groups exposed only to the radiation. These are preliminary findings based on only about one-fourth the eventual number of tumors expected.

NASA Discipline Radiation Health↗

Pixel-Registered Multimodal Synchrotron XRF and FTIR Microscopies Reveal Salinity Stress Response Mechanisms in Pistachio

Background: Salinity is a major abiotic stress that negatively affects nearly all plant species at all stages of growth. Drought and poor-quality irrigation cause high soil salinity and salt accumulation via evaporation, reducing crop productivity. Despite its critical importance, the spatial localization of salt ions and associated biochemical changes within plants experiencing high salinity remains largely unknown. In this study, we developed a multimodal imaging pipeline to understand the impact of salinity on the pistachio rootstock UCB-1 (Pistacia atlantica x Pistacia integerrima). We directly link biochemical fingerprints in stem tissue architecture with salt ion localization to provide insights into the strategies pistachio uses to tolerate salinity. Results: We observed that Pistacia spp. exposed to high salt conditions accumulated Ca, Si, Cl, Al and Mg as hotspots within the pith, compared to the control (of which only Ca and Al co-locate). In contrast, there was a decrease in K between the control and salinity treatment. Hotspots of amide I and II were present in the cortex and pith of the salinity treated sample. Additionally, the salinity treatment resulted in an increased abundance of pectin and carbohydrates within the pith compared to the control, and the abundance of esters/carboxylic acid was greater in the salinity treatment. Conclusions: We determined that Cl and K, S and P, and biochemical components polysaccharide and pectin, esters and carboxylic acid, amide I and cellulose are the strongest drivers of salinity- treatment induced variability. In the cortex and phloem/xylem, a negative K-Ca correlation decreases in the salinity treatment. Several hotspots of elements and amide I (proteins) appear under salinity treatment, particularly in the cortex, suggesting an increase in the production of stress-related proteins (in response to high Cl) and/or structural proteins (i.e. Ca). Together, these results indicate that pistachio responds to salinity through ion compartmentalization coupled with a targeted biochemical adjustment, rather than a broadscale tissue-wide response. Overall, these novel, spatially resolved pixel-registered multimodal imaging data provide an enabling platform to understand the mechanisms of salinity tolerance in Pistacia spp and can be broadly applied to studying stress-related phenotype response in various plant tissues.

FTIR spectromicroscopy↗

Cationic and Anionic Redox of Battery Cathodes Investigated by Advanced Synchrotron‐Based Mapping of Resonant Inelastic X‐ray Scattering

Abstract Redox reaction builds the foundation stone for the energy density of rechargeable battery cathodes. Probing and understanding the redox reaction behavior is crucial, but also extremely formidable, which requires individual and reliable detection of cationic and anionic redox states. Fortunately, the recently developed ultra‐high‐efficiency mapping of resonant inelastic X‐ray scattering (mRIXS) has emerged as a powerful tool to probe the battery chemistry states. Here, the latest advances of employing advanced mRIXS is summarized to investigate the cationic and anionic redox mechanism of battery cathodes during electrochemical operation. Owing to the new dimension of information along the emission energy and high sensitivity to valence 3d states, 3d transition‐metal L ‐edge (TM‐ L ) mRIXS can eliminate the lineshape distortion in conventional 3d TM‐ L fluorescence X‐ray absorption spectra and investigate the cationic redox quantitatively. Moreover, O‐ K mRIXS could fingerprint the intrinsic oxidized lattice oxygen states and quantify the oxygen redox (OR) reversibility, thus demystifying the controversy in traditional wisdom. In addition, different modification strategies coupled with underlying mechanisms for regulating the activity and reversibility of OR utilizing mRIXS are also summarized. This review provides valuable guidance for further exploration of underlying reaction mechanisms of battery cathodes by mRIXS, along with both technological and scientific improvements.

Cheng, Chen↗

Toward Real-Time Analysis of Synchrotron Micro-Tomography Data: Accelerating Experimental Workflows with AI and HPC

ynchrotron light sources are routinely used to perform imaging experiments. In this paper, we review the relevant computational stages, identify bottlenecks, and highlight future opportunities to streamline data acquisition for experimental microscopy workflows. We demonstrate our preliminary exploration with an end-to-end scientific workflow on Summit based on micro-computed tomography data. Computational elements include: 1) reconstruction of volumetric image data; 2) denoising with deep neural networks; and 3) non-local means based segmentation and quantitative analysis.

Mcclure, James↗