Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Suite”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

The ezSpectra suite: An easy‐to‐use toolkit for spectroscopy modeling

Abstract A molecule's spectrum encodes information about its structure and electronic properties. It is a unique fingerprint that can serve as a molecular ID. Quantum chemistry calculations provide key ingredients for interpreting spectra, but modeling the spectra rarely ends there; it requires additional steps that entail combined treatments of electronic and nuclear degrees of freedom and account for specifics of the experimental setup (light energy, polarization, averaging over molecular orientations, temperature, etc.). This Software Focus article describes the ezSpectra suite, which currently comprises two stand‐alone open‐source codes: ezFCF and ezDyson . ezFCF calculates Franck–Condon factors, which yield vibrational progressions for polyatomic molecules, within the double‐harmonic approximation. ezDyson calculates absolute cross‐sections for photodetachment/photoionization processes and photoelectron angular distributions using Dyson orbitals computed by a quantum chemistry program. This article is categorized under: Electronic Structure Theory > Ab Initio Electronic Structure Methods Theoretical and Physical Chemistry > Spectroscopy Software > Simulation Methods

Gozem, Samer↗

Using Hybrid Model OpenSHMEM + CUDA to Implement the SHOC Benchmark Suite

This work describes the process of porting the Scalable HeterOgeneous Computing (SHOC) benchmark suite from the hybrid MPI + CUDA implementation to OpenSHMEM + CUDA. SHOC includes a wide variety of benchmark kernels used to measure accelerator performance in both single node and cluster configurations. The hybrid model implementation attempts to place all major computation on accelerator devices, and uses MPI to synchronize and aggregate results. In some cases, MPI Groups are used to gradually reduce the number of accelerators used for computation as the problem size drops. Porting this behavior to OpenSHMEM required implementing several synchronizing collective operations, and using SHMEM teams to replace MPI Group functionality. Benchmark results on a Cray XK7 system with one GPU per compute node show that SHMEM performance is equal to MPI performance in these hybrid tasks. These results and porting experience show that using OpenSHMEM for accelerator devices benefits from adding functionality for synchronization and teams, and would further benefit from adding support for communication within accelerator kernels.

97 MATHEMATICS AND COMPUTING↗

Patient Radiation Dose Reduction Considerations in a Contemporary Interventional Radiology Suite

PurposeWe sought to evaluate patient radiation exposure during complex liver interventional procedures performed with newer angiography equipment.Materials and MethodsWe conducted a retrospective study of transjugular intrahepatic portosystemic shunt (TIPS) creations and liver tumor embolizations performed in our new angiography suite (Discovery IGS740, GE Healthcare). T tests were used to compare air kerma-area product (P{sub KA}) and reference plane air kerma (K{sub a,r}) in the new room versus data from historical rooms and previous studies (including the RAD IR study). Results were expressed as medians [interquartile ranges (Q1, Q3)].ResultsFrom February 2015 to June 2016, 134 complex liver interventional procedures were performed in the new room, including 14 TIPS creations, 60 hepatic tumor arterial embolizations (HAEs), 26 Y90 mappings (Y90m), and 34 Y90 radioembolizations (Y90). K{sub a,r} (Gy) values were as follows: TIPS, 0.65 (0.24, 1.15); HAE, 0.89 (0.49, 1.49); Y90m, 0.54 (0.38, 0.94); Y90, 0.46 (0.21, 1.06). P{sub KA} (Gy·cm{sup 2}) values were as follows: TIPS, 148.2 (66.7, 326.5); HAE, 142.6 (88, 217.8); Y90m, 148.3 (98.2, 247); Y90, 90.8 (43.9, 161.5). K{sub a,r} and P{sub KA} were lower in the new room than in historical rooms [K{sub a,r} and P{sub KA} reductions: TIPS, 58 and 49%; HAE, 31 and 39%; Y90m, 58 and 52%; Y90, 49 and 56% (p < 0.05)] and versus the RAD IR study [K{sub a,r} and P{sub KA} reductions: TIPS, 64 and 43%; HAE, 26 and 40% (p < 0.05)].ConclusionsUsing the latest technology and image processing tools enables significant reduction in radiation exposure during complex liver interventional procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of precipitation indices in suites of dynamically and statistically downscaled regional climate models over Florida

Abstract The present work evaluates historical precipitation and its indices defined by the Expert Team on Climate Change Detection and Indices (ETCCDI) in suites of dynamically and statistically downscaled regional climate models (RCMs) against NOAA’s Global Historical Climatology Network Daily (GHCN-Daily) dataset over Florida. The models examined here are: (1) nested RCMs involved in the North American CORDEX (NA-CORDEX) program, (2) variable resolution Community Earth System Models (VR-CESM), (3) Coupled Model Intercomparison Project phase 5 (CMIP5) models statistically downscaled using localized constructed analogs (LOCA) technique. To quantify observational uncertainty, three in situ-based (PRISM, Livneh, CPC) and three reanalysis (ERA5, MERRA2, NARR) datasets are also evaluated against the station data. The reanalyses and dynamically downscaled RCMs generally underestimate the magnitude of the monthly precipitation and the frequency of the extreme rainfall in summer. The models forced with CanESM2 miss the phase of the seasonality of extreme precipitation. All models and reanalyses severely underestimate both the mean and interannual variability of mean wet-day precipitation (SDII), consecutive dry days (CDD), and overestimate consecutive wet days (CWD). Metric analysis suggests large uncertainty across NA-CORDEX models. Both the LOCA and VR-CESM models perform better than the majority of models. Overall, RegCM4 and WRF models perform poorer than the median model performance. The performance uncertainty across models is comparable to that in the reanalyses. Specifically, NARR performs poorer than the median model performance in simulating the mean indices and MERRA2 performs worse than the majority of models in capturing the interannual variability of the indices.

54 ENVIRONMENTAL SCIENCES↗

The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

47 OTHER INSTRUMENTATION↗

The SuperCam Instrument Suite on the Mars 2020 Rover: Science Objectives and Mast-Unit Description

On the NASA 2020 rover mission to Jezero crater, the remote determination of the texture, mineralogy and chemistry of rocks is essential to quickly and thoroughly characterize an area and to optimize the selection of samples for return to Earth. As part of the Perseverance payload, SuperCam is a suite of five techniques that provide critical and complementary observations via Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), visible and near-infrared spectroscopy (VISIR), high-resolution color imaging (RMI), and acoustic recording (MIC). SuperCam operates at remote distances, primarily 2–7 m, while providing data at sub-mm to mm scales. We report on SuperCam’s science objectives in the context of the Mars 2020 mission goals and ways the different techniques can address these questions. The instrument is made up of three separate subsystems: the Mast Unit is designed and built in France; the Body Unit is provided by the United States; the calibration target holder is contributed by Spain, and the targets themselves by the entire science team. This publication focuses on the design, development, and tests of the Mast Unit; companion papers describe the other units. The goal of this work is to provide an understanding of the technical choices made, the constraints that were imposed, and ultimately the validated performance of the flight model as it leaves Earth, and it will serve as the foundation for Mars operations and future processing of the data.

47 OTHER INSTRUMENTATION↗

TOUGH3: A new efficient version of the TOUGH suite of multiphase flow and transport simulators

The TOUGH suite of nonisothermal multiphase flow and transport simulators has been updated by various developers over many years to address a vast range of challenging subsurface problems. The increasing complexity of the simulated processes as well as the growing size of model domains that need to be handled call for an improvement in the simulator's computational robustness and efficiency. Moreover, modifications have been frequently introduced independently, resulting in multiple versions of TOUGH that (1) led to inconsistencies in feature implementation and usage, (2) made code maintenance and development inefficient, and (3) caused confusion to users and developers. TOUGH3—a new base version of TOUGH—addresses these issues. It consolidates both the serial (TOUGH2 V2.1) and parallel (TOUGH2-MP V2.0) implementations, enabling simulations to be performed on desktop computers and supercomputers using a single code. New PETSc parallel linear solvers are added to the existing serial solvers of TOUGH2 and the Aztec solver used in TOUGH2-MP. The PETSc solvers generally perform better than the Aztec solvers in parallel and the internal TOUGH3 linear solver in serial. TOUGH3 also incorporates many new features, addresses bugs, and improves the flexibility of data handling. So due to the improved capabilities and usability, TOUGH3 is more robust and efficient for solving tough and computationally demanding problems in diverse scientific and practical applications related to subsurface flow modeling.

97 MATHEMATICS AND COMPUTING↗

The NETL MFiX Suite of multiphase flow models: A brief review and recent applications of MFiX-TFM to fossil energy technologies

Here, the MFiX suite of multiphase computational fluid dynamics (CFD) codes is being developed at U.S. Department of Energy's National Energy Technology Laboratory (NETL). It includes several different approaches to multiphase simulation: MFiX-TFM, a two-fluid (Eulerian–Eulerian) model; MFiX-DEM, an Eulerian fluid model with a Lagrangian Discrete Element Model for the solids phase; and MFiX-PIC, Eulerian fluid model with Lagrangian particle ‘parcels’ representing particle groups. These models are undergoing continuous development and application, with verification, validation, and uncertainty quantification (VV&UQ) as integrated activities. After a brief summary of recent progress in the verification, validation and uncertainty quantification (VV&UQ), this article highlights two recent accomplishments in the application of MFiX-TFM to fossil energy technology development. First, recent application of MFiX to the pilot-scale KBR TRIG™ Transport Gasifier located at DOE's National Carbon Capture Center (NCCC) is described. Gasifier performance over a range of operating conditions was modeled and compared to NCCC operational data to validate the ability of the model to predict parametric behavior. Second, comparison of code predictions at a detailed fundamental scale is presented studying solid sorbents for the post-combustion capture of CO 2 from flue gas. Specifically designed NETL experiments are being used to validate hydrodynamics and chemical kinetics for the sorbent-based carbon capture process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Northwest Africa 8159 martian meteorite: Expanding the martian sample suite to the early Amazonian

Northwest Africa (NWA) 8159 is an augite-rich shergottite, with a mineralogy dominated by Ca-, Fe-rich pyroxene, plagioclase, olivine, and magnetite. NWA 8159 crystallized from an evolved melt of basaltic composition under relatively rapid conditions of cooling, likely in a surface lava flow or shallow sill. Redox conditions experienced by the melt shifted from relatively oxidizing (with respect to known Martian lithologies, ~QFM) on the liquidus to higher oxygen fugacity (~QFM + 2) during crystallization of the groundmass, and under subsolidus conditions. This shift resulted in the production of orthopyroxene and magnetite replacing olivine phenocryst rims. NWA 8159 contains both crystalline and shock-amorphized plagioclase (An 50–62 ), often observed within a single grain; based on known calibrations we bracket the peak shock pressure experienced by NWA 8159 to between 15 and 23 GPa. The bulk composition of NWA 8159 is depleted in LREE, as observed for Tissint and other depleted shergottites; however, NWA 8159 is distinct from all other martian lithologies in its bulk composition and oxygen fugacity. Here, we obtain a Sm-Nd formation age of 2.37 ± 0.25 Ga for NWA 8159, which represents an interval in Mars geologic time which, until recently, was not represented in the other martian meteorite types. The bulk rock 147 Sm/ 144 Nd value of 0.37 ± 0.02 is consistent with it being derived directly from its source and the high initial ε 143 Nd value indicates this source was geochemically highly depleted. Cr, Nd, and W isotopic compositions further support a unique mantle source. While the rock shares similarities with the 2.4-Ga NWA 7635 meteorite, there are notable distinctions between the two meteorites that suggest differences in mantle source compositions and conditions of crystallization. Nevertheless, the two samples may be launch-paired. Finally, NWA 8159 expands the known basalt types, ages and mantle sources within the Mars sample suite to include a second igneous unit from the early Amazonian.

58 GEOSCIENCES↗

Intraoperative Radiation Therapy in Early Breast Cancer Using a Linear Accelerator Outside of the Operative Suite: An “Image-Guided” Approach

Purpose: To present local control, complications, and cosmetic outcomes of intraoperative radiation therapy (IORT) for early breast cancer, as well as technical aspects related to the use of a nondedicated linear accelerator. Methods and Materials: This prospective trial began in May of 2004. Eligibility criteria were biopsy-proven breast-infiltrating ductal carcinoma, age >40 years, tumor <3 cm, and cN0. Exclusion criteria were in situ or lobular types, multicentricity, skin invasion, any contraindication for surgery and/or radiation therapy, sentinel lymph node involvement, metastasis, or another malignancy. Patients underwent classic quadrantectomy with intraoperative sentinel lymph node and margins evaluation. If both free, the patient was transferred from operative suite to linear accelerator room, and IORT was delivered (21 Gy). Primary endpoint: local recurrence (LR); secondary endpoints: toxicities and aesthetics. Quality assurance involved using a customized shield for chest wall protection, applying procedures to minimize infection caused by patient transportation, and using portal films to check collimator-shield alignment. Results: A total of 152 patients were included, with at least 1 year follow-up. Median age (range) was 58.3 (40-85.4) years, and median follow-up time was 50.7 (12-110.5) months. The likelihood of 5-year local recurrence was 3.7%. There were 3 deaths, 2 of which were cancer related. The Kaplan-Meier 5-year actuarial estimates of overall, disease-free, and local recurrence-free survivals were 97.8%, 92.5%, and 96.3%, respectively. The overall incidences of acute and late toxicities were 12.5% and 29.6%, respectively. Excellent, good, fair, and bad cosmetic results were observed in 76.9%, 15.8%, 4.3%, and 2.8% of patients, respectively. Most treatments were performed with a 5-cm collimator, and in 39.8% of the patients the electron-beam energy used was ≥12 MeV. All patients underwent portal film evaluation, and the shielding was repositioned in 39.9% of cases. No infection or anesthesia complications were observed. Conclusions: Local control with IORT was adequate, with low complication rates and good cosmetic outcomes. More than one-third of patients benefited from the “image-guidance” approach, and almost 40% benefited from the option of higher electron beam energies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Autonomous sensor suite for evaluating fish-turbine interactions and environmental impacts in marine renewable energy and hydropower

Marine renewable energy (MRE) harnesses ocean-based resources such as waves, tides, currents, and thermal or salinity gradients for sustainable power generation. It has the potential to complement existing renewable resources, support remote communities, and contribute to decarbonization efforts. However, understanding the hydrodynamic forces created by MRE devices and their impacts on marine life is critical for responsible deployment. Here, to address these concerns, advanced sensor devices, including the Marine Sensor Fish (MSF), Sensor Fish Mini (SF Mini), and Flexible Sensor Fish (FSF), were developed to measure interactions between aquatic organisms and MRE systems. This paper details the design, manufacturing, calibration, and field deployment of these sensor suites, highlighting their ability to capture key physical stressors such as shear forces, pressure changes, and collision impacts. The MSF successfully evaluated turbine interactions at a tidal turbine in the Salish Sea, capturing data on turbulence, collision impact, and pressure gradients. The SF Mini validated hydrodynamic conditions in scaled hydraulic models, supporting computational fluid dynamics simulations. The FSF, with its flexible silicone body, measured species-specific impacts in turbulent environments. This research demonstrates the potential of Sensor Fish technology to advance sustainable marine energy systems by reducing biological impacts and informing environmentally sustainable designs.

Ecological impacts↗

The DESC stellarator code suite Part 3: Quasi-symmetry optimization

The DESC stellarator optimization code takes advantage of advanced numerical methods to search the full parameter space much faster than conventional tools. Only a single equilibrium solution is needed at each optimization step thanks to automatic differentiation, which efficiently provides exact derivative information. A Gauss–Newton trust-region optimization method uses second-order derivative information to take large steps in parameter space and converges rapidly. With just-in-time compilation and GPU portability, high-dimensional stellarator optimization runs take orders of magnitude less computation time with DESC compared to other approaches. This paper presents the theory of the DESC fixed-boundary local optimization algorithm along with demonstrations of how to easily implement it in the code. Example quasi-symmetry optimizations are shown and compared to results from conventional tools. Three different forms of quasi-symmetry objectives are available in DESC, and their relative advantages are discussed in detail. In the examples presented, the triple product formulation yields the best optimization results in terms of minimized computation time and particle transport. This paper concludes with an explanation of how the modular code suite can be extended to accommodate other types of optimization problems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Suite of Constitutive Promoters for Tuning Gene Expression in Plants

The need for convenient tools to express transgenes over a large dynamic range is pervasive throughout plant synthetic biology; however, current efforts are largely limited by the heavy reliance on a small set of strong promoters, precluding more nuanced and refined engineering endeavors in planta . To address this technical gap, we characterize a suite of constitutive promoters that span a wide range of transcriptional levels and develop a GoldenGate-based plasmid toolkit named PCONS, optimized for versatile cloning and rapid testing of transgene expression at varying strengths. We demonstrate how easy access to a stepwise gradient of expression levels can be used for optimizing synthetic transcriptional systems and the production of small molecules in planta . We also systematically investigate the potential of using PCONS as an internal standard in plant biology experimental design, establishing the best practices for signal normalization in experiments. Although our library has primarily been developed for optimizing expression in N. benthamiana , we demonstrate the translatability of our promoters across distantly related species using a multiplexed reporter assay with barcoded transcripts. In conclusion, our findings showcase the advantages of the PCONS library as an invaluable toolkit for plant synthetic biology.

59 BASIC BIOLOGICAL SCIENCES↗

Simulation of a suite of generic long-pulse neutron instruments to optimize the time structure of the European Spallation Source

We here describe the result of simulations of 15 generic neutron instruments for the long-pulsed European Spallation Source. All instruments have been simulated for 20 different settings of the source time structure, corresponding to pulse lengths between 1 ms and 2 ms; and repetition frequencies between 10 Hz and 25 Hz. The relative change in performance with time structure is given for each instrument, and an unweighted average is calculated. The performance of the instrument suite is proportional to (a) the peak flux and (b) the duty cycle to a power of approximately 0.3. This information is an important input to determining the best accelerator parameters. In addition, we find that in our simple guide systems, most neutrons reaching the sample originate from the central 3-5 cm of the moderator. This result can be used as an input in later optimization of the moderator design. We discuss the relevance and validity of defining a single figure-of-merit for a full facility and compare with evaluations of the individual instrument classes.

43 PARTICLE ACCELERATORS↗

Diagnostic suite of the C-2U advanced beam-driven field-reversed configuration plasma experiment

The C-2U experiment at Tri Alpha Energy studies the evolution of field-reversed configuration (FRC) plasmas sustained by neutral beam injection. Data on the FRC plasma performance are provided by a comprehensive suite of diagnostics that includes magnetic sensors, interferometry, Thomson scattering, spectroscopy, bolometry, reflectometry, neutral particle analyzers, and fusion product detectors. While many of these diagnostic systems were inherited from the preceding experiment C-2, C-2U has a variety of new and upgraded diagnostic systems: multi-chord far-infrared polarimetry, multiple fast imaging cameras with selectable atomic line filters, proton detector arrays, and 100 channel bolometer units capable of observing multiple regions of the spectrum simultaneously. In addition, extensive ongoing work focuses on advanced methods of measuring separatrix shape and plasma current profile that will facilitate equilibrium reconstruction and active control of the FRC plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A suite-level review of the neutron single-crystal diffraction instruments at Oak Ridge National Laboratory

The nascent suite of single-crystal neutron diffractometers at the Oak Ridge National Laboratory has no equal at any other neutron scattering facility worldwide and offers the potential to re-assert single-crystal diffraction using neutrons as a significant tool to study nuclear and magnetic structures of small unit cell crystals, nuclear structures of macromolecules, and diffuse scattering. Signature applications and features of single-crystal neutron diffraction are high resolution nuclear structure analysis, magnetic structure and spin density determinations, contrast variation (particularly D 2 O/H 2 O) for nuclear structural studies, lack of radiation damage when using crystals of biological molecules such as proteins, and the fidelity to measure nuclear and magnetic diffuse scattering with elastic discrimination.

47 OTHER INSTRUMENTATION↗

TURBOMOLE: Modular program suite for ab initio quantum-chemical and condensed-matter simulations

TURBOMOLE is a collaborative, multi-national software development project aiming to provide highly efficient and stable computational tools for quantum chemical simulations of molecules, clusters, periodic systems, and solutions. The TURBOMOLE software suite is optimized for widely available, inexpensive, and resource-efficient hardware such as multi-core workstations and small computer clusters. TURBOMOLE specializes in electronic structure methods with outstanding accuracy–cost ratio, such as density functional theory including local hybrids and the random phase approximation (RPA), GW-Bethe–Salpeter methods, second-order Møller–Plesset theory, and explicitly correlated coupled-cluster methods. TURBOMOLE is based on Gaussian basis sets and has been pivotal for the development of many fast and low-scaling algorithms in the past three decades, such as integral-direct methods, fast multipole methods, the resolution-of-the-identity approximation, imaginary frequency integration, Laplace transform, and pair natural orbital methods. This review focuses on recent additions to TURBOMOLE’s functionality, including excited-state methods, RPA and Green’s function methods, relativistic approaches, high-order molecular properties, solvation effects, and periodic systems. A variety of illustrative applications along with accuracy and timing data are discussed. Moreover, available interfaces to users as well as other software are summarized. TURBOMOLE’s current licensing, distribution, and support model are discussed, and an overview of TURBOMOLE’s development workflow is provided. Challenges such as communication and outreach, software infrastructure, and funding are highlighted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Scattered Light Time-history Diagnostic suite at the National Ignition Facility

The Scattered Light Time-history Diagnostic (SLTD) is being implemented at the National Ignition Facility (NIF) to greatly expand the angular coverage of absolute scattered-light measurements for direct- and indirect-drive inertial confinement fusion (ICF) experiments. The SLTD array will ultimately consist of 15 units mounted at a variety of polar and azimuthal angles on the NIF target chamber, complementing the existing NIF backscatter suite. Each SLTD unit collects and diffuses scattered light onto a set of three optical fibers, which transport the light to filtered photodiodes to measure scattered light in different wavelength bands: stimulated Brillouin scattering (350 nm–352 nm), stimulated Raman scattering (430 nm–760 nm), and ω/2 (695 nm–745 nm). SLTD measures scattered light with a time resolution of ~1 ns and a signal-to-noise ratio of up to 500. Currently, six units are operational and recording data. Measurements of the angular dependence of scattered light will strongly constrain models of laser energy coupling in ICF experiments and allow for a more robust inference of the total laser energy coupled to implosions.

47 OTHER INSTRUMENTATION↗