Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Storage systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Development of an integrated heat pipe-thermal storage system for a solar receiver

The Organic Rankine Cycle (ORC) Solar Dynamic Power System (SDPS) is one of the candidates for Space Station prime power application. In the low Earth orbit of the Space Station approximately 34 minutes of the 94-minute orbital period is spent in eclipse with no solar energy input to the power system. For this period the SDPS will use thermal energy storage (TES) material to provide a constant power output. An integrated heat-pipe thermal storage receiver system is being developed as part of the ORC-SDPS solar receiver. This system incorporates potassium heat pipe elements to absorb and transfer the solar energy within the receiver cavity. The heat pipes contain the TES canisters within the potassium vapor space with the toluene heater tube used as the condenser region of the heat pipe. During the insolation period of the Earth orbit, solar energy is delivered to the heat pipe in the ORC-SDPS receiver cavity. The heat pipe transforms the non-uniform solar flux incident in the heat pipe surface within the receiver cavity to an essentially uniform flux at the potassium vapor condensation interface in the heat pipe. During solar insolation, part of the thermal energy is delivered to the heater tube and the balance is stored in the TES units. During the eclipse period of the orbit, the balance stored in the TES units is transferred by the potassium vapor to the toluene heater tube.

Keddy, E. S.↗

Indirect, dual-media, phase changing material modular thermal energy storage system

Design, validate at prototype level, and then demonstrate a full size, 800 MWht Thermal Energy Storage (TES) system based on Phase Changing Material (PCM) TES modules with round trip efficiency in excess of 93%. The PCM TES module would be the building block of a TES system which can be deployed at costs inline with the DOE benchmark of 2020. The development of a reliable, unsophisticated, modular, and scalable TES system designed to be massmanufactured utilizing advanced automated fabrication and assembly processes and field installed in the most cost-effective configuration could facilitate the attainment of a Levelized Cost of Energy (LCOE) of $.07/kWh by 2015. It was believed that the DOE targets can be attained by finding the best combinationTES module size, its optimal integration in the power cycle, and readily available PCM. Work under this project ultimately focused on the development and performance evaluation of a 100kWht prototype heat exchanger. The design utilizes a commercially available heat exchanger product to create a unique latent heat PCM storage module. The novel ideal associated with this technology is the inclusion of an agitation mechanism that is activated during the discharge process to improve heat transfer. The prototype unit did not meet the performance goals estimated through modeling, nor did the estimated costs of the system fall in line with the goals established by DOE.

14 SOLAR ENERGY↗

Integrated Heat Exchanger-Phase Change Material Thermal Energy Storage System

The purpose of this study is to experimentally investigate the thermal performance of an innovative thermal energy storage (TES) system that combines the advantages of the phase-change material (PCM)/graphite foam latent heat TES medium developed at Argonne National Laboratory (Argonne) and the internally supported plate-fin (ISPE) cell architecture heat transfer fluid (HTF) flow channels developed at Brayton Energy (Brayton). Several essential tasks were accomplished: (1) Thermal property characterization. Thermal properties of the graphite foam were characterized, providing necessary data for experimental result analysis and numerical simulation. (2) Design and optimization of lab-scale test module. Based on Brayton’s full-scale heat exchanger (HX)-TES system, the experimental test module was designed, optimized, and fabricated. (3) Thermal performance testing and data analysis. Five cycle tests were successfully conducted—including one with approximately 3.5 psig of pressure applied to the diaphragms—to investigate the thermal performance of the experimental test module for charging and discharging. Temperature profiles were generated for each charging test and discharging test as a function of time. The temperature profiles clearly show three TES stages: sensible heat (temperature increase), latent heat (melting), and sensible heat (temperature increase) for the charging process. Similarly, the temperature profiles clearly show three thermal energy release stages: sensible heat (temperature decrease), latent heat (solidification), and sensible heat (temperature decrease). Melting and solidification of the PCM generally occurred in relatively narrow temperature ranges, indicated by the flattened temperature regions in the temperature profiles. These phase changes ranged approximately 3°C for melting and 3.5°C for solidification. The charging and discharging temperature profiles were similar for similar experimental parameter tests whether or not pressure was applied to the diaphragm to eliminate the gap between the HX surface and the TES subsystem. This indicates that the effect of a small gap between the HX surface and the TES subsystem is insignificant for charging and discharging. (4) Comparison of experimental data and simulation results. We compared the experimental data to the numerical simulation results. Numerical simulations were conducted by using the ANSYS FLUENT 2019 R3 commercial computational fluid dynamics software. The predicted phase-change times agreed reasonably well with those from the experimental data. In most cases, the estimated time differences between the relative phase changes were within 16%. The predicted start and end times for the charging process agreed well with those from the experimental data. However, the simulation results showed earlier start and end times than the experimental data for the discharging process. Overall, the experimental data and its comparison with the simulation predictions verified the technical viability of the integrated ISPF HX-PCM/graphite foam latent-heat TES system.

25 ENERGY STORAGE↗

Design and Testing of a Thermal Storage System for Electric Vehicle Cabin Heating

Without the waste heat available from the engine of a conventional automobile, electric vehicles (EVs) must provide heat to the cabin for climate control using energy stored in the vehicle. In current EV designs, this energy is typically provided by the traction battery. In very cold climatic conditions, the power required to heat the EV cabin can be of a similar magnitude to that required for propulsion of the vehicle. As a result, the driving range of an EV can be reduced very significantly during winter months, which limits consumer acceptance of EVs and results in increased battery costs to achieve a minimum range while ensuring comfort to the EV driver. To minimize the range penalty associated with EV cabin heating, a novel climate control system that includes thermal energy storage has been designed for use in EVs and plug-in hybrid electric vehicles (PHEVs). The system uses the stored latent heat of an advanced phase change material (PCM) to provide cabin heating. The PCM is melted while the EV is connected to the electric grid for charging of the electric battery, and the stored energy is subsequently transferred to the cabin during driving. To minimize thermal losses when the EV is parked for extended periods, the PCM is encased in a high performance insulation system. The electrical PCM-Assisted Thermal Heating System (ePATHS) was designed to provide enough thermal energy to heat the EV s cabin for approximately 46 minutes, covering the entire daily commute of a typical driver in the U.S.

electric vehicles↗

Design Optimization Study on the Single Tank Packed-bed Thermal Energy Storage System

Idaho National Laboratory (INL) is establishing the Dynamic Energy Transport and Integration Lab (DETAIL) as part of its commitment to research on nuclear-renewable hybrid energy systems and associated advanced reactor technologies. DETAIL is designed to allow several different energy systems to work in unison. Current plans include a PWR simulator, high-temperature steam electrolysis (HSTE) unit, and a renewable energy system (e.g., photovoltaics). DETAIL will provide the real world basis for studies on the systems integration and system configurations to be completed. Encompassed in the DETAIL program is the Thermal Energy Storage (TES) system. The TES system is one of the key components in DETAIL because it allows for the delayed release of energy and can be used to simulate storage capabilities currently being considered by utility providers. Of the various TES concepts, this paper deals with the single-tank packed bed TES system. Particular attention is given to the transient thermal behavior of fluid and solid particles within the packed bed thermocline tank and heat storage efficiency influenced by various design parameters. The effects of tank geometry (height-to-diameter ratio), filler size, filler packing ratio and operating temperature differentials are investigated. Based on the parametric study and cost analysis, the optimal TES tank design for DETAIL is discussed.

25 ENERGY STORAGE↗

Building and managing high performance, scalable, commodity mass storage systems

The NAS Systems Division has recently embarked on a significant new way of handling the mass storage problem. One of the basic goals of this new development are to build systems at very large capacity and high performance, yet have the advantages of commodity products. The central design philosophy is to build storage systems the way the Internet was built. Competitive, survivable, expandable, and wide open. The thrust of this paper is to describe the motivation for this effort, what we mean by commodity mass storage, what the implications are for a facility that performs such an action, and where we think it will lead.

Lekashman, John↗

Performance and cost of energy transport and storage systems for dish applications using reversible chemical reactions

The use of reversible chemical reactions for energy transport and storage for parabolic dish networks is considered. Performance and cost characteristics are estimated for systems using three reactions (sulfur-trioxide decomposition, steam reforming of methane, and carbon-dioxide reforming of methane). Systems are considered with and without storage, and in several energy-delivery configurations that give different profiles of energy delivered versus temperature. Cost estimates are derived assuming the use of metal components and of advanced ceramics. (The latter reduces the costs by three- to five-fold). The process that led to the selection of the three reactions is described, and the effects of varying temperatures, pressures, and heat exchanger sizes are addressed. A state-of-the-art survey was performed as part of this study. As a result of this survey, it appears that formidable technical risks exist for any attempt to implement the systems analyzed in this study, especially in the area of reactor design and performance. The behavior of all components and complete systems under thermal energy transients is very poorly understood. This study indicates that thermochemical storage systems that store reactants as liquids have efficiencies below 60%, which is in agreement with the findings of earlier investigators.

Schredder, J. M.↗

Analysis of degradation in residential battery energy storage systems for rate-based use-cases

This article examines the impact of residential battery energy storage (BES) systems' operational modes on the life (i.e. usable energy capacity) of the battery under several climatic conditions and battery chemistries. The sharp increase in residential BES installations has been a result of decreasing costs of batteries, increase in rate structures motivated applications such as solar self-consumption and time-of-use energy management, and customers purchasing these systems for backup power. While these different modes of operations provide a combination of increased bill savings, reliability of supply, and energy sustainability to the customer, their operational characteristics vary significantly between use-cases. Functional life of BES systems is known to be strongly dependent on their operating conditions. In this article, we analyze the operation of residential BES systems under different rate-based use-cases, for different battery chemistries and cell designs, and under different environmental conditions. This is conducted by simulating the control of BES operations using rate-based cycling algorithms and analyzing the prognosis of multiple battery lifetime models that consider complex nonlinear dependencies of operational stress factors such as state-of-charge, depth-of-discharge, and temperature on degradation. Significant variations in battery life are observed owing to the differences in characteristics of the uses-cases coupled with environmental conditions and battery chemistries. Such differences lead to the conclusion that choice of residential BES technologies and chemistries should account for their intended use-cases.

25 ENERGY STORAGE↗

Technical and economic feasibility of molten chloride salt thermal energy storage systems

A techno-economic study is performed to assess the feasibility of molten chloride salt thermal energy storage (TES) systems for next generation concentrating solar power. Refractory liners internally insulate tanks to allow tank shells to be constructed from carbon steel. The liner must not be wetted by salt to maintain predictable thermal properties and manageable heat loss out of the tank. The commercial scale tank liner is an anchored brick and mortar design with expansion joints to accommodate thermal expansion. Furthermore, finite element analysis is performed to optimize the thermal and mechanical profile of the tank. Equalizing the shell temperature between the water-cooled foundation and the shell wall is necessary to minimize differential thermomechanical stress and lower overall stress values below industrial allowable limits. The cost of the TES system is estimated to be $60/kWhth, which is four times greater than Department of Energy targets. Solutions to reduce system cost and overall risk are proposed.

14 SOLAR ENERGY↗

A Boundary Element Model for Assessing Large‐Scale Pressurization in Faulted Geological Storage Systems

Assessing large-scale pressurization at the regional scale—a possible outcome of large subsurface storage applications such as wastewater injection and geological carbon sequestration—presents significant computational challenges. These challenges are particularly pronounced when accounting for complex geologic structures with multiple reservoir and caprock layers, fault zones, and wells. This study introduces a computationally efficient model that integrates single-phase semi-analytical solutions with a boundary element (BE) approach. The model simulates pressure propagation in multilayered 3D systems, including vertical faults, caprock, basement, and confining units. We apply this new model to a representative scenario involving CO 2 injection near a partially sealing fault with verification against an independent two-phase flow model. Results demonstrate that our model accurately captures far-field pressure responses and that, outside the CO 2 plume zone, pressure predictions from single-phase and two-phase models are nearly identical. This supports the use of single-phase models like ours for efficient estimation of far-field pressure changes. Additionally, we demonstrate its effectiveness at a large scale, incorporating multiple wells and faults. With its ability to represent multiple wells, fault zones, and geological heterogeneity, our model is well suited for assessments of basin-scale pressurization. Its computational efficiency also makes it a promising tool for integration with optimization frameworks aimed at designing and managing injection strategies in faulted storage systems.

Cihan, A. [Lawrence Berkeley National Laboratory (↗

Finned-tube-integrated modular thermal storage systems for HVAC load modulation in buildings

While there is considerable focus on latent-based thermal energy storage (TES) systems, the low thermal conductivity of phase change materials (PCMs) remains a critical concern. Many approaches to enhance PCM conductivity either require complicated synthesis processes or are cost prohibitive. In this study, we investigate finned-tube modular TES systems, which are simple in design, easy to manufacture, and cost-effective due to their standard materials and components. The study includes detailed modeling and experimentation of two devices containing similar amounts of PCM but different fin spacings. The study reveals that having more fins does not necessarily increase the TES thermal performance because the reduction in the PCM volume fraction can reduce the TES volumetric and specific energy densities. We find that larger fin spacings provide a higher specific energy for lower C rates (<1C), while smaller fin spacings provide a higher specific energy for higher C rates (>1C).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Inverter Output Filter Effect on PWM Motor Drives of a Flywheel Energy Storage System

NASA Glenn Research Center (GRC) has been involved in the research and development of high speed flywheel systems for small satellite energy storage and attitude control applications. One research and development area has been the minimization of the switching noise produced by the pulsed width modulated (PWM) inverter that drives the flywheel permanent magnet motor/generator (PM M/G). This noise can interfere with the flywheel M/G hardware and the system avionics hampering the full speed performance of the flywheel system. One way to attenuate the inverter switching noise is by placing an AC filter at the three phase output terminals of the inverter with the filter neutral point connected to the DC link (DC bus) midpoint capacitors. The main benefit of using an AC filter in this fashion is the significant reduction of the inverter s high dv/dt switching and its harmonics components. Additionally, common mode (CM) and differential mode (DM) voltages caused by the inverter s high dv/dt switching are also reduced. Several topologies of AC filters have been implemented and compared. One AC filter topology consists of a two-stage R-L-C low pass filter. The other topology consists of the same two-stage R-L-C low pass filter with a series connected trap filter (an inductor and capacitor connected in parallel). This paper presents the analysis, design and experimental results of these AC filter topologies and the comparison between the no filter case and conventional AC filter.

Santiago, Walter↗

Storage systems for solar thermal power

The development status is reviewed of some thermal energy storage technologies specifically oriented towards providing diurnal heat storage for solar central power systems and solar total energy systems. These technologies include sensible heat storage in caverns and latent heat storage using both active and passive heat exchange processes. In addition, selected thermal storage concepts which appear promising to a variety of advanced solar thermal system applications are discussed.

Calogeras, J. E.↗