Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectral control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

The MSFC vector magnetograph

The NASA/Marshall Space Flight Center's solar vector magnetograph system allows measurements of all components of the Sun's photospheric magnetic field over a 5 x 5 or 2.5 x 2.5 arc min square field of view with an optimum time resolution of approximately 100 sec and an optimum signal-to-noise of approximately 1000. The basic system components are described, including the optics, detector, digital system, and associated electronics. Automatic sequencing and control functions are outlined as well as manual selections of system parameters which afford unique system flexibility. Results of system calibration and performance are presented, including linearity, dynamic range, uniformity, spatial and spectral resolutions, signal-to-noise, electro-optical retardation and polarization calibration.

Hagyard, M. J.↗

Astrophysics

The instrumentation, accomplishments and future activities in space astrophysics observations are explored. The Solrad, Orbiting Solar Observatory, Solar Maximum Mission, Orbiting Astronomical Observatory, Extreme Ultraviolet Explorer, Uhuru, HEAO-2, IRAS and ESA SAS spacecraft missions and data are summarized. Observations which identified the black hole in Cygnus-1 are described and known gravity-controlled phenomena in the universe are reviewed. Observations at different electromagnetic wavelengths and by particle detectors are outlined, and proposed gravity wave and neutrino detectors are discussed. The implications of the angular, spectral and temporal resolution, polarization, spectral range and observational limits of the instrumentation and data are considered. Current topics of interest in studies of the cosmic background radiation, distance scales, quasars and pulsars, star formation, and coronal heating are outlined. Finally, the design features and observational goals of the NASA Great Observatories space platforms are described.

Gilman, David A.↗

An investigation of acoustic noise requirements for the Space Station centrifuge facility

Acoustic noise emissions from the Space Station Freedom (SSF) centrifuge facility hardware represent a potential technical and programmatic risk to the project. The SSF program requires that no payload exceed a Noise Criterion 40 (NC-40) noise contour in any octave band between 63 Hz and 8 kHz as measured 2 feet from the equipment item. Past experience with life science experiment hardware indicates that this requirement will be difficult to meet. The crew has found noise levels on Spacelab flights to be unacceptably high. Many past Ames Spacelab life science payloads have required waivers because of excessive noise. The objectives of this study were (1) to develop an understanding of acoustic measurement theory, instruments, and technique, and (2) to characterize the noise emission of analogous Facility components and previously flown flight hardware. Test results from existing hardware were reviewed and analyzed. Measurements of the spectral and intensity characteristics of fans and other rotating machinery were performed. The literature was reviewed and contacts were made with NASA and industry organizations concerned with or performing research on noise control.

Castellano, Timothy↗

Investigation of Point Doppler Velocimetry (PDV) for Transition Detection in Boundary Layers

A two component Point Doppler Velocimetry (PDV) system has been developed and tested. Improvements were made to an earlier PDV system, in terms of experimental techniques, as well as the data acquisition and reduction software. Measurements of the streamwise and spanwise mean and fluctuating velocities for flows from a rectangular channel and over an NACA 0012 airfoil were made, and the data were compared against hot wire data. The closest to the airfoil surface that PDV measurements could be made was on the order of 0.005 m(0.2", z/c = 0.0169). When the PDV and hot wire data were compared, the time traces for each appeared similar. The mean velocities agreed to within plus or minus 2 m/sec, while the RMS velocities agreed to plus or minus 0.4 m/sec. While the PDV time autocorrelations agreed with those of the hot wire data, the PDV power spectral densities were noisier above 750 Hz. A major source of error in these experiments was determined to be the drifting of the iodine cell stem temperatures. While the stem temperatures were controlled to within plus or minus 0.1 C, this could lead to a frequency shift of as much as 6 MHz, which translates into an error of 1.6 m/sec for the back scatter channel, and up to 6.9 m/sec for the forward scatter channel. These error estimates are consistent with the observed error magnitudes.

Kuhlman, John M.↗

The IFS for WFIRST CGI: Science Requirements to Design

Direct Imaging of exoplanets using a coronagraph has become a major field of research both on the ground and in space. Key to the science of direct imaging is the spectroscopic capabilities of the instrument, our ability to extract spectra, and measure the abundance of molecular species such as Methane. To take these spectra, the WFIRST coronagraph instrument (CGI) uses an integral field spectrograph (IFS), which encodes the spectrum into a two-dimensional image on the detector. This results in more efficient detection and characterization of targets, and the spectral information is critical to achieving detection limits below the speckle floor of the imager. The CGI IFS operates in two18% bands spanning 600nm to 840nm at a nominal spectral resolution of R50. We present the current science and engineering requirements for the IFS design, the instrument design, anticipated performance, and how the calibration is integrated into the focal plane wavefront control algorithms. We also highlight the role of the Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) at the JPL High Contrast Imaging Testbed to demonstrate performance and validate calibration methodologies for the flight instrument.

Groff, Tyler D.↗

Designing a Decontamination Solution for the Low-Earth-Orbit, Cryogenic SPHEREx Mission

To address the scientific goals of NASA’s astrophysics division, the JPL and Caltech’s SPHEREx mission conducts the first near-infrared all-sky spectral survey in low-earth-orbit using a passively-cooled, cryogenic telescope. Several unique water contamination issues arise due to the combination of cryogenic operation temperatures and the limited temperature control authority of passive cooling. Because water molecules have adsorption bands within the wavelengths of interest for SPHEREx’s survey, it is imperative that water contamination be controlled and minimized. In this work, a model is developed for the SPHEREx mission to predict the transport and accumulation of outgassed water onto sensitive payload components. The model utilizes the time dependent thermal profiles of the individual payload components, initial water content, and spacecraft geometry to calculate the time dependent water diffusion, transport, and adsorption. This model is subsequently used to predict water contamination risks and design decontamination solutions for each risk. Two major water contamination risks were predicted, water accumulation during cooldown and on cryogenic surfaces during the mission. The first risk occurs during the cooldown of the payload to cryogenic temperatures, predicting water accumulation on optical surfaces in excess of the allowable levels. To mitigate this accumulation, the temperature of the optical surfaces is controlled during cooldown through a combination of heaters and spacecraft pointing. The second risk is that over the course of the mission, is unavoidable water accumulation onto the payload thermal system’s cryogenic surfaces, possibly jeopardizing thermal performance and temperature stability, both of which are required for science success. To decontaminate any water that had collected onto cryogenic thermal system surfaces, a decontamination maneuver was designed. In this decontamination maneuver, cryogenic surfaces of the thermal system are warmed to a temperature where water will desorb by spacecraft pointing while still meeting all avoidance constraints, and thereby avoiding undue risk to the observatory hardware. Through application of the developed analytical model and inclusion of the decontamination maneuver in the mission design, SPHEREx can confidently demonstrate that it is able to decontaminate, at the start of and during the mission as needed to meet its end of life science performance requirements.

Soares, Carolos E.↗

Acoustic Study of a Sweeping Jet Actuator for Active Flow Control Applications

Active flow control for aircraft has been demonstrated to improve aerodynamic performance but generally introduces additional noise sources. This study presents measurements of the acoustic fields of sweeping jet actuators at full- and half-scale compared to the configuration recently demonstrated in ground- and flight-tests of a full-scale rudder. The effects of scale, flow rate, forward speed, and actuator synchronization state on tone and broadband noise directional power spectral density (PSD) levels are presented. The sweeping jet actuator PSD levels in the audio range increases as the second power of actuator flow rate. A fourth power variation of PSD level with flow rate is observed for a comparable non-sweeping actuator. These measurements will be used to develop noise source models for new aircraft configurations utilizing active flow control.

Active Flow Control Noise↗

Adaptive on-line classification of multi-spectral scanner data

A possible solution to the analysis of the massive amounts of multi-spectral scanner data from the Earth Resource Technical Satellite (ERTS) program is proposed. This solution is offered as an adaptive on-line classification scheme. The classifier is described as well as its controller which is based on ground truth data. Cluster analysis is presented as an alternative approach to the ground truth data. Adaptive feature selection is discussed and possible mini-computer implementations are offered.

Fromm, F. R.↗

An Induced Environment Contamination Monitor for the Space Shuttle

The Induced Environment Contamination Monitor (IECM), a set of ten instruments integrated into a self-contained unit and scheduled to fly on shuttle Orbital Flight Tests 1 through 6 and on Spacelabs 1 and 2, is described. The IECM is designed to measure the actual environment to determine whether the strict controls placed on the shuttle system have solved the contamination problem. Measurements are taken during prelaunch, ascent, on-orbit, descent, and postlanding. The on-orbit measurements are molecular return flux, background spectral intensity, molecular deposition, and optical surface effects. During the other mission phases dew point, humidity, aerosol content, and trace gas are measured as well as optical surface effects and molecular deposition. The IECM systems and thermal design are discussed. Preflight and ground operations are presented together with associated ground support equipment. Flight operations and data reduction plans are given.

Miller, E. R.↗

Tunable pulsed carbon dioxide laser

Transverse electrically-excited-atmosphere (TEA) laser is continuously tunable over several hundred megahertz about centers of spectral lines of carbon dioxide. It is operated in single longitudinal mode (SLM) by injection of beam from continuous-wave, tunable-waveguide carbon dioxide laser, which serves as master frequency-control oscillator. Device measures absorption line of ozone; with adjustments, it is applicable to monitoring of atmospheric trace species.

Megie, G. J.↗

Ultraviolet spectroscopy of comets

Results of observations of comets in the ultraviolet are reviewed in relation to their significance for the chemistry and physics of the cometary coma and the composition of the cometary ice. Ultraviolet cometary observations began in 1970, when a hydrogen envelope was discovered extending millions of kilometers from the nucleus of comet Bennett, and continued with the discovery of oxygen and carbon in comet Kohoutek and the acquisition of comprehensive UV spectra from comets West (1976 VI), Seargent (1978 XV) and Bradfield (1979 X). The available cometary spectra are remarkably similar, indicative of a common composition and origin for comets and the insignificance of chemical reactions in the inner coma to species abundances. Ultraviolet spectroscopy has also allowed the determination of gas production rates from either the surface brightness or the total luminosity in a given spectral line. IUE observations of comet Bradfield reveal the water production rate to vary as the -3.7 power of heliocentric distance from 0.71 to 1.55 AU, incompatible with solar energy input as the controlling influence on water vaporization.

Feldman, P. D.↗

The Berkeley extreme ultraviolet calibration facility

The vacuum calibration facilities of the Space Sciences Laboratory, University of California at Berkeley are designed for the calibration and testing of EUV and FUV spaceborne instrumentation (spectral range 44-2500 A). The facility includes one large cylindrical vacuum chamber (3 x 5 m) containing two EUV collimators, and it is equipped with a 4-axis manipulator of angular-control resolution 1 arcsec for payloads weighing up to 500 kg. In addition, two smaller cylindrical chambers, each 0.9 x 1.2 m, are available for vacuum and thermal testing of UV detectors, filters, and space electronics hardware. All three chambers open into class-10,000 clean rooms, and all calibrations are referred to NBS secondary standards.

Welsh, Barry Y.↗

Inversion of imaging spectrometry data using singular value decomposition

The use of imaging spectrometers, which acquire data that are both spectrally contiguous images and spatially contiguous spectra, for quantitative remote sensing of the earth is addressed. Such data sets cannot be analyzed fully using either existing spectroscopic or image techniques. Singular value decomposition (SVD) is used here for spectral unmixing and determination of the spatial scales of mixing. It is shown that when it is used to invert the mixing endmember library, SVD allows more insight into library characteristics and more control of the inversion process than other commonly used matrix inversion techniques.

Boardman, Joe W.↗

First results from a laboratory facility for measurement of emission spectra under simulated planetary conditions

We have developed a laboratory spectroscopic facility for the measurement of emission spectra under simulated planetary conditions. Spectral measurements are made from 6 to 13 microns with a scanning grating monochromator equipped with a HgCdTl detector. An environment chamber in service in Hawaii for several years in which we can control the temperature from 77 K to 500 K, the pressure from 10(exp -5) torr to two atmospheres, has been equipped with a 77 K or 273 K cold shield. The shield serves to minimize light reflected off the sample and to aid in development of thermal gradients for obtaining spectra under conditions simulating the thermal environment of airless bodies. Samples are placed in small cups on a temperature controlled substrate allowing measurements of emission due to heating from below by the substrate, or from illumination from a solar simulation source.

Lucey, Paul G.↗

A New Satellite System for Measuring BRDF from Space

Formation flying of satellites is at the beginning of an explosive growth curve. Spacecraft buses are shrinking to the point where we will soon be able to launch 10 micro-satellites or 100 nano-satellites on a single launch vehicle. Simultaneously, spectrometers are just beginning to be flown in space by both the U.S. and Europe. On-board programmable band aggregation will soon allow exactly the spectral bands desired to be returned to Earth. Further efforts are being devoted to radically shrink spectrometers both in size and weight. And GPS positioning and attitude determination, plus new technologies for attitude control, will allow fleets of satellites to all point at the same Earth target. All these advances, in combination, make possible for the first time the proper measurement of Bidirectional Reflectance Distribution (BRDF) form space. Previously space BDRF's were mere composites, built up over time by viewing different types of scenes at different times, then creating catalogs of BDRF functions whose use relied upon correct "scene identification" --the weak link. Formation-flying micro-satellites, carrying programmable spectrometers and precision-pointing at the same Earth target, can measure the full BDRF simultaneously, in real time. This talk will review these technological advances and discuss an actual proposed concept, based on these advances, to measure Earth-target BDRF's (clouds as well as surface) across the full solar spectrum in the 2010 timeframe. This concept is part of a larger concept called Leonardo for properly measuring the radiative forcing of Earth for climate purposes; lack of knowing of BDRF and of diurnal cycle are at present the two limiting factors preventing improved estimates of this forcing.

Wiscombe, W.↗

Pre-Hardware Optimization and Implementation Of Fast Optics Closed Control Loop Algorithms

One of the main heritage tools used in scientific and engineering data spectrum analysis is the Fourier Integral Transform and its high performance digital equivalent - the Fast Fourier Transform (FFT). The FFT is particularly useful in two-dimensional (2-D) image processing (FFT2) within optical systems control. However, timing constraints of a fast optics closed control loop would require a supercomputer to run the software implementation of the FFT2 and its inverse, as well as other image processing representative algorithm, such as numerical image folding and fringe feature extraction. A laboratory supercomputer is not always available even for ground operations and is not feasible for a night project. However, the computationally intensive algorithms still warrant alternative implementation using reconfigurable computing technologies (RC) such as Digital Signal Processors (DSP) and Field Programmable Gate Arrays (FPGA), which provide low cost compact super-computing capabilities. We present a new RC hardware implementation and utilization architecture that significantly reduces the computational complexity of a few basic image-processing algorithm, such as FFT2, image folding and phase diversity for the NASA Solar Viewing Interferometer Prototype (SVIP) using a cluster of DSPs and FPGAs. The DSP cluster utilization architecture also assures avoidance of a single point of failure, while using commercially available hardware. This, combined with the control algorithms pre-hardware optimization, or the first time allows construction of image-based 800 Hertz (Hz) optics closed control loops on-board a spacecraft, based on the SVIP ground instrument. That spacecraft is the proposed Earth Atmosphere Solar Occultation Imager (EASI) to study greenhouse gases CO2, C2H, H2O, O3, O2, N2O from Lagrange-2 point in space. This paper provides an advanced insight into a new type of science capabilities for future space exploration missions based on on-board image processing for control and for robotics missions using vision sensors. It presents a top-level description of technologies required for the design and construction of SVIP and EASI and to advance the spatial-spectral imaging and large-scale space interferometry science and engineering.

Kizhner, Semion↗

Instruments for Imaging from Far to Near

The acronym CHAMP (signifying camera, hand lens, and microscope ) denotes any of several proposed optoelectronic instruments that would be capable of color imaging at working distances that could be varied continuously through a range from infinity down to several millimeters. As in any optical instrument, the magnification, depth of field, and spatial resolution would vary with the working distance. For example, in one CHAMP version, at a working distance of 2.5 m, the instrument would function as an electronic camera with a magnification of 1/100, whereas at a working distance of 7 mm, the instrument would function as a microscope/electronic camera with a magnification of 4.4. Moreover, as described below, when operating at or near the shortest-working-distance/highest-magnification combination, a CHAMP could be made to perform one or more spectral imaging functions. CHAMPs were originally intended to be used in robotic geological exploration of the Moon and Mars. The CHAMP concept also has potential for diverse terrestrial applications that could include remotely controlled or robotic geological exploration, prospecting, field microbiology, environmental surveying, and assembly- line inspection. A CHAMP (see figure) would include two lens cells: (1) a distal cell corresponding to the objective lens assembly of a conventional telescope or microscope and (2) a proximal cell that would contain the focusing camera lens assembly and the camera electronic image-detector chip, which would be of the active-pixel-sensor (APS) type. The distal lens cell would face outward from a housing, while the proximal lens cell would lie in a clean environment inside the housing. The proximal lens cell would contain a beam splitter that would enable simultaneous use of the imaging optics (that is, proximal and distal lens assemblies) for imaging and illumination of the field of view. The APS chip would be mounted on a focal plane on a side face of the beam splitter, while light for illuminating the field of view would enter the imaging optics via the end face of the beam splitter. The proximal lens cell would be mounted on a sled that could be translated along the optical axis for focus adjustment. The position of the CHAMP would initially be chosen at the desired working distance of the distal lens from (corresponding to an approximate desired magnification of) an object to be examined. During subsequent operation, the working distance would ordinarily remain fixed at the chosen value and the position of the proximal lens cell within the instrument would be adjusted for focus as needed.

Mungas, Greg↗

A Compilation of Global Bio-Optical in Situ Data for Ocean-Colour Satellite Applications

A compiled set of in situ data is important to evaluate the quality of ocean-colour satellite-data records. Here we describe the data compiled for the validation of the ocean-colour products from the ESA Ocean Colour Climate Change Initiative (OC-CCI). The data were acquired from several sources (MOBY, BOUSSOLE, AERONET-OC, SeaBASS, NOMAD, MERMAID, AMT, ICES, HOT, GePCO), span between 1997 and 2012, and have a global distribution. Observations of the following variables were compiled: spectral remote-sensing reflectances, concentrations of chlorophyll a, spectral inherent optical properties and spectral diffuse attenuation coefficients. The data were from multi-project archives acquired via the open internet services or from individual projects, acquired directly from data providers. Methodologies were implemented for homogenisation, quality control and merging of all data. No changes were made to the original data, other than averaging of observations that were close in time and space, elimination of some points after quality control and conversion to a standard format. The final result is a merged table designed for validation of satellite-derived ocean-colour products and available in text format. Metadata of each in situ measurement (original source, cruise or experiment, principal investigator) were preserved throughout the work and made available in the final table. Using all the data in a validation exercise increases the number of matchups and enhances the representativeness of different marine regimes. By making available the metadata, it is also possible to analyse each set of data separately. The compiled data are available at doi:10.1594PANGAEA.854832 (Valente et al., 2015).

Valente, Andre↗