Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spatial dependence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Insight into SEI Growth in Li-Ion Batteries using Molecular Dynamics and Accelerated Chemical Reactions

The performance of lithium-ion batteries (LIB) using organic electrolytes strongly depends on the formation of a stable solid electrolyte interphase (SEI) film. Elucidating the dynamic evolution and spatial composition of the SEI can be very useful to study the stability of SEI components and help optimize the formation cycles of LIB. We propose a classical molecular dynamics simulation protocol for predicting the first stages of SEI formation using a reaction method involving the decomposition of EC and LiPF 6 molecules in the electrolyte. We accelerate the formation of SEI components near the anode surface by increasing the probability of reactions, implemented through a geometry matching scheme, followed by a force-field reconfiguration. We observe the formation of gases (C 2 H 4 ), inorganic (Li 2 CO 3 and LiF) and organic (LEDC) components. Finally, this protocol shows promise to be able to evaluate the effects of varying electrolyte compositions and additives on SEI layer structure and composition.

25 ENERGY STORAGE↗

Efficient interlayer electron transfer in a MoTe 2 /WS 2 /MoS 2 trilayer heterostructure

Electron transfer and carrier dynamics in MoTe 2 /WS 2 /MoS 2 trilayer heterostructures are investigated by transient absorption and photoluminescence measurements. Monolayer flakes of MoTe 2 , WS 2 , and MoS 2 are obtained by mechanical exfoliation from their bulk crystals and are used to fabricate the heterostructures by a dry-transfer technique. Here, photoluminescence spectroscopic measurements indicate that the recombination of the MoS 2 and WS 2 intralayer excitons is significantly suppressed in the heterostructure, illustrating the efficient interlayer charge transfer processes. Layer-selective time-resolved differential reflectance measurements show that the electrons excited in MoTe 2 can transfer to MoS 2 within 0.3 ps. The transferred electrons show a long lifetime of several hundred picoseconds due to their slow recombination with the spatially separated holes that reside in MoTe 2 . Furthermore, the charge transfer and recombination processes are weakly dependent on the injected carrier density. These results demonstrate the feasibility of constructing van der Waals multilayer heterostructures involving the infrared-sensitive MoTe 2 with emergent properties and provide important information to quantify the performance of MoTe 2 - based devices.

2D materials↗

Cooperative response of magnetism and superconductivity in the magnetic superconductor RbEuFe 4 As 4

Herein, we present a study of the magnetic-flux evolution in the magnetic superconductor RbEuFe 4 As 4 performed using magneto-optical imaging and magnetization measurements during field cooling and warming and magnetic field cycling at temperatures above and below the magnetic transition point, T$_m$. The vortex patterns emerging at T ≲ T$_m$ reveal that the Eu-spin subsystem serves as an internal pump of the magnetic flux while the superconducting critical current controls the delivery of magnetic-flux quanta into the bulk. The interplay of magnetic susceptibility amplifying the magnetic induction and vortex pinning attenuating the magnetic-flux entry results in a field- and temperature-dependent critical state that emulates a paramagnetic Meissner effect. The observed vortex dynamics corresponds to a nontrivial spatial current distribution and yields a self-consistent inhomogeneous enhancement of the sample magnetization.

36 MATERIALS SCIENCE↗

Resolution requirements for numerical modeling of neutrino quantum kinetics

Neutrino quantum kinetics is a rapidly evolving field in computational astrophysics, with a primary focus on collective neutrino oscillations in core-collapse supernovae and postmerger phases of binary neutron star mergers. In recent years, there has been considerable debate concerning resolution dependence in numerical simulations. In this paper, we conduct a comprehensive resolution study in both angular- and spatial directions by using two independent schemes of quantum kinetic neutrino transport: finite volume and pseudospectral methods. We complement our discussion by linear stability analysis including inhomogeneous modes. Our result suggests that decreasing spatial resolutions underestimates the growth of flavor instability, and then leads to wrong asymptotic states of flavor conversions, which potentially has a critical impact on astrophysical consequences. We further delve into numerical results of low resolution simulations, that reveals the underlying mechanism responsible for numerical artifacts caused by insufficient resolutions. Finally, this study settles the debate on requirements of resolutions and serves as a guideline for numerical modeling of quantum kinetic neutrino transport.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Iterative Stress Reconstruction Algorithm to Estimate Three-Dimensional Residual Stress Fields in Manufactured Components

Residual stress (RS) significantly impacts the mechanical performance of components. Measurement of RS often provides incomplete data in terms of components of stress and spatial density. Employing such fields in finite element simulations results in significant modification of the field to achieve equilibrium and compatibility among strains. To overcome this, an iterative stress reconstruction algorithm (ISRA) is developed to estimate 3D RS fields that satisfy equilibrium, are stress component-wise complete, and represent the characterized data sampled. An Al 7075-T651 plate and an additively manufactured (AM) A36 steel wall are considered for RS reconstruction using measurement data from the literature. A maximum variation of ~2.5 MPa in the Al plate, and ~10 MPa in the steel wall are observed between the reconstructed and measured stresses. Furthermore, unknown stress components emerge and reach significant magnitudes (upto ~2.3 MPa in the Al plate and ~45 MPa in the AM wall) during ISRA. Indeed, it is found that minor errors in measurement or data processing are eliminated through the physical requirements during ISRA. Employing a reconstructed RS field is hence not just more accurate given its compatibility, but it additionally corrects for minor errors in measurement. Furthermore, it is found that spatially dense measurement data result in convergence with fewer iterations. Finally, although ISRA yields a nonunique solution dependent on boundary conditions, measurement errors, fitting errors, and mesh density, it accommodates for uncertainties and inaccuracies in measurement, as opposed to failing to reach a physically realistic converged solution.

42 ENGINEERING↗

A measurement of two-photon exchange in Super-Rosenbluth separations with positron beams

The proton electric and magnetic form factors, G E and G M , are intrinsically connected to the spatial distribution of charge and magnetization in the proton. For decades, Rosenbluth separation measurements of the angular dependence of elastic e--p scattering were used to extract G E and G M . More recently, polarized electron scattering measurements, aiming to improve the precision of G E extractions, showed significant disagreement with Rosenbluth measurements at large momentum transfers (Q 2 ). This discrepancy is generally attributed to neglected two-photon exchange (TPE) corrections. At larger Q 2 values, a new ‘Super-Rosenbluth’ technique was used to improve the precision of the Rosenbluth extraction, allowing for a better quantification of the discrepancy, while comparisons of e + -p and e - -p scattering indicated the presence of TPE corrections, but at Q 2 values below where a clear discrepancy is observed. Here, in this work, we demonstrate the significant benefits to combining the Super-Rosenbluth technique with positron beam measurements. This approach provides a greater kinematic reach and is insensitive to some of the key systematic uncertainties in previous positron measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

MicroBooNE NS Timing Corrections

MicroBooNE has achieved a neutrino interaction timing resolution of O(1 ns), enabling improved background rejection and new physics searches. We identify a systematic bias in the reconstructed times of NCpi0 and nueCC events, which appear earlier than numuCC events, with a strong dependence on drift distance (reco_nuvtxX). An empirical correction, applied to high-energy showers, removes this spatial bias and aligns timing across topologies. The correction is validated across data runs and event selections, though the root cause remains under investigation.

Chan, Andrew [Michigan U.]↗

Filled Elastomers: Mechanistic and Physics-Driven Modeling and Applications as Smart Materials

Elastomers are made of chain-like molecules to form networks that can sustain large deformation. Rubbers are thermosetting elastomers that are obtained from irreversible curing reactions. Curing reactions create permanent bonds between the molecular chains. On the other hand, thermoplastic elastomers do not need curing reactions. Incorporation of appropriated filler particles, as has been practiced for decades, can significantly enhance mechanical properties of elastomers. However, there are fundamental questions about polymer matrix composites (PMCs) that still elude complete understanding. This is because the macroscopic properties of PMCs depend not only on the overall volume fraction (ϕ) of the filler particles, but also on their spatial distribution (i.e., primary, secondary, and tertiary structure). This work aims at reviewing how the mechanical properties of PMCs are related to the microstructure of filler particles and to the interaction between filler particles and polymer matrices. Overall, soft rubbery matrices dictate the elasticity/hyperelasticity of the PMCs while the reinforcement involves polymer–particle interactions that can significantly influence the mechanical properties of the polymer matrix interface. For ϕ values higher than a threshold, percolation of the filler particles can lead to significant reinforcement. While viscoelastic behavior may be attributed to the soft rubbery component, inelastic behaviors like the Mullins and Payne effects are highly correlated to the microstructures of the polymer matrix and the filler particles, as well as that of the polymer–particle interface. Additionally, the incorporation of specific filler particles within intelligently designed polymer systems has been shown to yield a variety of functional and responsive materials, commonly termed smart materials. We review three types of smart PMCs, i.e., magnetoelastic (M-), shape-memory (SM-), and self-healing (SH-) PMCs, and discuss the constitutive models for these smart materials.

36 MATERIALS SCIENCE↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Mechanically graded granular scaffolds for osteochondral tissue engineering

Engineered scaffolds designed to approximate the mechanical microenvironment of the osteochondral unit often address this complexity using discrete, two-phase architectures that introduce mechanical discontinuities and interfacial stress concentrations rather than a contiguous stiffness transition. To address this challenge, we created a photoannealed polyethylene glycol (PEG) granular scaffold with a spatially controlled stiffness gradient within a cell-permissive, macroporous architecture. Stiffness was dictated by photoannealing microgels using a photomask. We tuned void volume and available surface area by varying microgel diameter and tested how mesenchymal stromal cells (MSCs) interpret local mechanical environments. MSCs exhibited position-dependent differences in morphology, cytoskeletal structure, matrix deposition, and lineage-specific gene expression within the gradient scaffolds. Softer regions supported rounded cell morphology and deposition of a glycosaminoglycan-rich matrix, whereas stiffer regions promoted cell elongation, increased cytoskeletal tension, and expression of mineral-associated markers. Gradients formed from smaller microgels magnified these spatial responses by increasing cellular confinement and adhesion site availability. Disruption of actomyosin contractility eliminated these regional differences, demonstrating that MSCs rely on tension-dependent mechanotransduction to interpret the gradient. These findings reveal that coupling microgel architecture with continuous stiffness transitions provides a tractable platform to study multiscale mechanobiologic regulation and spatially guide osteochondral tissue formation.

Biological and medical sciences↗

A machine learning approach to emulation and biophysical parameter estimation with the Community Land Model, version 5

Abstract. Land models are essential tools for understanding and predicting terrestrial processes and climate–carbon feedbacks in the Earth system, but uncertainties in their future projections are poorly understood. Improvements in physical process realism and the representation of human influence arguably make models more comparable to reality but also increase the degrees of freedom in model configuration, leading to increased parametric uncertainty in projections. In this work we design and implement a machine learning approach to globally calibrate a subset of the parameters of the Community Land Model, version 5 (CLM5) to observations of carbon and water fluxes. We focus on parameters controlling biophysical features such as surface energy balance, hydrology, and carbon uptake. We first use parameter sensitivity simulations and a combination of objective metrics including ranked global mean sensitivity to multiple output variables and non-overlapping spatial pattern responses between parameters to narrow the parameter space and determine a subset of important CLM5 biophysical parameters for further analysis. Using a perturbed parameter ensemble, we then train a series of artificial feed-forward neural networks to emulate CLM5 output given parameter values as input. We use annual mean globally aggregated spatial variability in carbon and water fluxes as our emulation and calibration targets. Validation and out-of-sample tests are used to assess the predictive skill of the networks, and we utilize permutation feature importance and partial dependence methods to better interpret the results. The trained networks are then used to estimate global optimal parameter values with greater computational efficiency than achieved by hand tuning efforts and increased spatial scale relative to previous studies optimizing at a single site. By developing this methodology, our framework can help quantify the contribution of parameter uncertainty to overall uncertainty in land model projections.

54 ENVIRONMENTAL SCIENCES↗

Distance-dependent dielectric constant at the calcite/electrolyte interface: Implication for surface complexation modeling

Hypothesis: The electrical double layer formed at the mineral/electrolyte interface is often modeled using mean-field approaches based on a continuum description of the solvent whose dielectric constant is assumed to decrease monotonically with decreasing distance to the surface. In contrast, molecular simulations show that the solvent polarizability oscillates near the surface similar to the water density profile - as shown previously, for example, by Bonthuis et al. (D.J. Bonthuis, S. Gekle, R.R. Netz, Dielectric Profile of Interfacial Water and its Effect on Double-Layer Capacitance, Phys Rev Lett 107(16) (2011) 166102). Here, we showed that molecular and mesoscale pictures agree by spatially averaging the dielectric constant obtained from molecular dynamics simulations over the distances relevant to the mean-field representation. In addition, the values of capacitances used to describe the electrical double layer in Surface Complexation Models (SCMs) of the mineral/electrolyte interface can be estimated using molecularly informed spatially averaged dielectric constants and positions of hydration layers. Experiments: First, we used molecular dynamics simulations to model the calcite 101¯4/electrolyte interface. Next, by using atomistic trajectories, we calculated the distance-dependent static dielectric constant and water density in the direction normal to the. Finally, we applied spatial compartmentalization consistent with the model of parallel-plate capacitors connected in series to estimate SCM capacitances. Findings: Computationally expensive simulations are required to determine the dielectric constant profile of interfacial water near the mineral surface. On the other hand, water density profiles are readily assessable from much shorter simulation trajectories. Our simulations confirmed that dielectric and water density oscillations at the interface are correlated. Here, we parametrized linear regression models to estimate the dielectric constant directly from the local water density. This is a significant computational shortcut compared to slowly converging calculations relying on total dipole moment fluctuations. The amplitude of the interfacial dielectric constant oscillation can exceed the dielectric constant of the bulk water, suggesting an ice-like frozen state, but only if there are no electrolyte ions. The interfacial accumulation of electrolyte ions causes a decrease in the dielectric constant due to the reduction of water density and re-orientation of water dipoles in ion hydration shells. Finally, we show how to use the computed dielectric properties to estimate SCM's capacitances.

58 GEOSCIENCES↗

Measurements of time and spatial resolution of AC-LGADs with different designs

AC-LGAD sensors are prime candidates for fast and precise measurement of charged particles in a variety of applications. In a fine-pitched pixel or strip AC-LGAD sensor, the signal generated by the passage of a particle is not localized in a limited volume in the sensor, but is shared among multiple electrodes. This signal sharing characteristic allows us to improve the spatial resolution of AC-LGAD sensors beyond the capabilities of common silicon trackers. Since the magnitude of the shared signal depends on the distance between the pixels or strips and the point of passage of the particle, signal sharing is strongly influenced by the geometry of the sensor. The electrode pitch and gap size as well as the shape can be fine tuned to maximize the space resolution, while keeping the detector granularity and the number of channels to be read out under control. Prototypes of AC-LGAD sensors produced at the Brookhaven National Laboratory covering a variety of possible geometries have been studied via Transient Current Technique using an infrared laser, and the signal sharing, spatial resolution, and time resolution of the different topologies have been measured. These results have been compared with measurements performed in test-beams with 120 GeV protons at the Fermilab Test Beam Facility. A time resolution of ~30 ps can be achieved using AC-LGAD sensors with a thickness of 50 μm, compatible to that of standard DC-coupled LGADs, while presenting a far superior spatial resolution. Finally, this combination of high precision, fast timing capabilities, and low material budget makes AC-LGADs an ideal choice for a truly 4D detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-cell spatial metabolomics with cell-type specific protein profiling for tissue systems biology

Metabolic reprogramming in cancer and immune cells occurs to support their increasing energy needs in biological tissues. Here we propose Single Cell Spatially resolved Metabolic (scSpaMet) framework for joint protein-metabolite profiling of single immune and cancer cells in male human tissues by incorporating untargeted spatial metabolomics and targeted multiplexed protein imaging in a single pipeline. We utilized the scSpaMet to profile cell types and spatial metabolomic maps of 19507, 31156, and 8215 single cells in human lung cancer, tonsil, and endometrium tissues, respectively. The scSpaMet analysis revealed cell type-dependent metabolite profiles and local metabolite competition of neighboring single cells in human tissues. Deep learning-based joint embedding revealed unique metabolite states within cell types. Trajectory inference showed metabolic patterns along cell differentiation paths. Here we show scSpaMet’s ability to quantify and visualize the cell-type specific and spatially resolved metabolic-protein mapping as an emerging tool for systems-level understanding of tissue biology.

59 BASIC BIOLOGICAL SCIENCES↗

Seismic waves in medium with poroelastic/elastic interfaces: a two-dimensional P-SV finite-difference modelling

SUMMARY We present a new methodology of the finite-difference (FD) modelling of seismic wave propagation in a strongly heterogeneous medium composed of poroelastic (P) and (strictly) elastic (E) parts. The medium can include P/P, P/E and E/E material interfaces of arbitrary shapes. The poroelastic part can be with (i) zero resistive friction, (ii) non-zero constant resistive friction or (iii) JKD model of the frequency-dependent permeability and resistive friction. Our FD scheme is capable of subcell resolution: a material interface can have an arbitrary position in the spatial grid. The scheme keeps computational efficiency of the scheme for a smoothly and weakly heterogeneous medium (medium without material interfaces). Numerical tests against independent analytical, semi-analytical and spectral-element methods prove the efficiency and accuracy of our FD modelling. In numerical examples, we indicate effect of the P/E interfaces for the poroelastic medium with a constant resistive friction and medium with the JKD model of the frequency-dependent permeability and resistive friction. We address the 2-D P-SV problem. The approach can be readily extended to the 3-D problem.

58 GEOSCIENCES↗