Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sorting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Numerical modeling based machine learning approach for the optimization of falling - film evaporator in thermal desalination application

Scale formation that drastically increases thermal resistance and reduces freshwater production remains a critical challenge in thermal desalination. Novel designs of falling film evaporator and optimal operating condition hold great promise to mitigate scale formation, and increase heat transfer performance and fresh water production. In this work, CFD simulation based machine learning and multi-objective optimization are performed to identify optimal conditions and tube arrangement for evaporator. Non-dominated sorting genetic algorithm is adopted to determine and analyze the optimal pareto front for multiple objectives in desalination criteria. The errors of training, validation, and testing set are computed to identify an optimal hyperparameter set. For performance ratio, fouling resistance, and water production rate, the average relative error is 2.26%, 3.67%, and 3.24%. At pareto front, both performance ratio and water production rate increase at high temperature with fouling resistance (thermal resistance of the fouling layer) increasing as well. Tradeoffs between mitigating scale formation and enhancing desalination performance are evaluated in optimizations for different objectives. Finally, potential optima are identified and can be applied as guidelines to determine evaporator design and system operating conditions.

42 ENGINEERING↗

Verification of Planning Target Volume Settings in Volumetric Modulated Arc Therapy for Stereotactic Body Radiation Therapy by Using In-Treatment 4-Dimensional Cone Beam Computed Tomography

Purpose: To evaluate setup error and tumor motion during beam delivery by using 4-dimensional cone beam computed tomography (4D CBCT) and to assess the adequacy of the planning target volume (PTV) margin for lung cancer patients undergoing volumetric modulated arc therapy for stereotactic body radiation therapy (VMAT-SBRT). Methods and Materials: Fifteen lung cancer patients treated by single-arc VMAT-SBRT were selected in this analysis. All patients were treated with an abdominal compressor. The gross tumor volumes were contoured on maximum inspiration and maximum expiration CT datasets from 4D CT respiratory sorting and merged into internal target volumes (ITVs). The PTV margin was isotropically taken as 5 mm. Registration was automatically performed using “pre-3D” CBCT. Treatment was performed with a D95 prescription of 50 Gy delivered in 4 fractions. The 4D tumor locations during beam delivery were determined using in-treatment 4D CBCT images acquired in each fraction. Then, the discrepancy between the actual tumor location and the ITV was evaluated in the lateral, vertical, and longitudinal directions. Results: Overall, 55 4D CBCT sets during VMAT-SBRT were successfully obtained. The amplitude of tumor motion was less than 10 mm in all directions. The average displacements between ITV and actual tumor location during treatment were 0.41 ± 0.93 mm, 0.15 ± 0.58 mm, and 0.60 ± 0.99 mm for the craniocaudal, left-right, and anteroposterior directions, respectively. The discrepancy in each phase did not exceed 5 mm in any direction. Conclusions: With in-treatment 4D CBCT, we confirmed the required PTV margins when the registration for moving target was performed using pre-3D CBCT. In-treatment 4D CBCT is a direct method for quantitatively assessing the intrafractional location of a moving target.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-Dose Hyper-Radiosensitivity Is Not a Common Effect in Normal Asynchronous and G2-Phase Fibroblasts of Cancer Patients

Purpose: In our previous study, using the micronucleus assay, a low-dose hyper-radiosensitivity (HRS)-like phenomenon was observed for normal fibroblasts of 2 of the 40 cancer patients investigated. In this article we report, for the first time, the survival response of primary fibroblasts from 25 of these patients to low-dose irradiation and answer the question regarding the effect of G2-phase enrichment on HRS elicitation. Methods and Materials: The clonogenic survival of asynchronous as well as G2-phase enriched fibroblast populations was measured. Separation of G2-phase cells and precise cell counting was performed using a fluorescence-activated cell sorter. Sorted and plated cells were irradiated with single doses (0.1-4 Gy) of 6-MV x-rays. For each patient, at least 4 independent experiments were performed, and the induced-repair model was fitted over the whole data set to confirm the presence of HRS effect. Results: The HRS response was demonstrated for the asynchronous and G2-phase enriched cell populations of 4 patients. For the rest of patients, HRS was not defined in either of the 2 fibroblast populations. Thus, G2-phase enrichment had no effect on HRS elicitation. Conclusions: The fact that low-dose hyper-radiosensitivity is not a common effect in normal human fibroblasts implies that HRS may be of little consequence in late-responding connective tissues with regard to radiation fibrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mobilization of Viable Tumor Cells Into the Circulation During Radiation Therapy

Purpose: To determine whether radiation therapy (RT) could mobilize viable tumor cells into the circulation of non-small cell lung cancer (NSCLC) patients. Methods and Materials: We enumerated circulating tumor cells (CTCs) by fluorescence microscopy of blood samples immunostained with conventional CTC markers. We measured their DNA damage levels using γ-H2AX, a biomarker for radiation-induced DNA double-strand breaks, either by fluorescence-activated cell sorting or by immunofluorescence microscopy. Results: Twenty-seven RT-treated NSCLC patients had blood samples analyzed by 1 or more methods. We identified increased CTC numbers after commencement of RT in 7 of 9 patients treated with palliative RT, and in 4 of 8 patients treated with curative-intent RT. Circulating tumor cells were also identified, singly and in clumps in large numbers, during RT by cytopathologic examination (in all 5 cases studied). Elevated γ-H2AX signal in post-RT blood samples signified the presence of CTCs derived from irradiated tumors. Blood taken after the commencement of RT contained tumor cells that proliferated extensively in vitro (in all 6 cases studied). Circulating tumor cells formed γ-H2AX foci in response to ex vivo irradiation, providing further evidence of their viability. Conclusions: Our findings provide a rationale for the development of strategies to reduce the concentration of viable CTCs by modulating RT fractionation or by coadministering systemic therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time Tumor Oxygenation Changes After Single High-dose Radiation Therapy in Orthotopic and Subcutaneous Lung Cancer in Mice: Clinical Implication for Stereotactic Ablative Radiation Therapy Schedule Optimization

Purpose: To investigate the serial changes of tumor hypoxia in response to single high-dose irradiation by various clinical and preclinical methods to propose an optimal fractionation schedule for stereotactic ablative radiation therapy. Methods and Materials: Syngeneic Lewis lung carcinomas were grown either orthotopically or subcutaneously in C57BL/6 mice and irradiated with a single dose of 15 Gy to mimic stereotactic ablative radiation therapy used in the clinic. Serial [{sup 18}F]-misonidazole (F-MISO) positron emission tomography (PET) imaging, pimonidazole fluorescence-activated cell sorting analyses, hypoxia-responsive element-driven bioluminescence, and Hoechst 33342 perfusion were performed before irradiation (day −1), at 6 hours (day 0), and 2 (day 2) and 6 (day 6) days after irradiation for both subcutaneous and orthotopic lung tumors. For F-MISO, the tumor/brain ratio was analyzed. Results: Hypoxic signals were too low to quantitate for orthotopic tumors using F-MISO PET or hypoxia-responsive element-driven bioluminescence imaging. In subcutaneous tumors, the maximum tumor/brain ratio was 2.87 ± 0.483 at day −1, 1.67 ± 0.116 at day 0, 2.92 ± 0.334 at day 2, and 2.13 ± 0.385 at day 6, indicating that tumor hypoxia was decreased immediately after irradiation and had returned to the pretreatment levels at day 2, followed by a slight decrease by day 6 after radiation. Pimonidazole analysis also revealed similar patterns. Using Hoechst 33342 vascular perfusion dye, CD31, and cleaved caspase 3 co-immunostaining, we found a rapid and transient vascular collapse, which might have resulted in poor intratumor perfusion of F-MISO PET tracer or pimonidazole delivered at day 0, leading to decreased hypoxic signals at day 0 by PET or pimonidazole analyses. Conclusions: We found tumor hypoxia levels decreased immediately after delivery of a single dose of 15 Gy and had returned to the pretreatment levels 2 days after irradiation and had decreased slightly by day 6. Our results indicate that single high-dose irradiation can produce a rapid, but reversible, vascular collapse in tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-Induced Esophagitis In Vivo and In Vitro Reveals That Epidermal Growth Factor Is a Potential Candidate for Therapeutic Intervention Strategy

Purpose: To establish and characterize radiation-induced esophagitis (RIE) in vivo and in vitro. Methods and Materials: Fractionated thoracic irradiation at 0, 8, 12, or 15 Gy was given daily for 5 days to Balb/c or C57Bl/6 mice. Changes in body weight gain and daily food intake were assessed. At the end of the study, we removed the esophagus and examined histology by hematoxylin and eosin staining, immune cell infiltration and apoptosis by fluorescence-activated cell sorting, and gene expression changes by quantitative real-time polymerase chain reaction. Het-1A human esophageal epithelial cells were irradiated at 6 Gy, treated with recombinant human growth factors, and examined for gene expression changes, apoptosis, proliferation, and signal transduction pathways. Results: We observed that irradiation at 12 Gy or 15 Gy per fraction produced significant reduction in body weight and decreased food intake in Balb/c mice but not as much in C57Bl/6 mice. Further analyses of Balb/c mice irradiated at 12 Gy/fraction revealed attenuated epithelium, inflamed mucosa, and increased numbers of infiltrating CD4+ helper T cells and apoptotic cells. Moreover, we found that expression of tissue inhibitor for metalloproteinase-1, plasminogen activator inhibitor-1, granulocyte macrophage-colony stimulating factor, vascular endothelial growth factor, and stromal-derived factor-1 were increased, whereas epidermal growth factor (EGF) was decreased. Irradiated Het-1A cells similarly showed a significant decrease in expression of EGF and connective tissue growth factor (CTGF). Treatment of EGF but not CTGF partially protected Het-1A cells from radiation-induced apoptosis and revealed phosphorylation of EGFR, AKT, and ERK signaling pathways. Conclusions: We established a mouse model of RIE in Balb/c mice with 12 Gy × 5 fractions, which showed reduced body weight gain, food intake, and histopathologic features similar to those of human esophagitis. Decreased EGF expression in the irradiated esophagus suggests that EGF may be a potential therapeutic intervention strategy to treat RIE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observer Evaluation of a Metal Artifact Reduction Algorithm Applied to Head and Neck Cone Beam Computed Tomographic Images

Purpose and Objectives: To quantify, through an observer study, the reduction in metal artifacts on cone beam computed tomographic (CBCT) images using a projection-interpolation algorithm, on images containing metal artifacts from dental fillings and implants in patients treated for head and neck (H&N) cancer. Methods and Materials: An interpolation-substitution algorithm was applied to H&N CBCT images containing metal artifacts from dental fillings and implants. Image quality with respect to metal artifacts was evaluated subjectively and objectively. First, 6 independent radiation oncologists were asked to rank randomly sorted blinded images (before and after metal artifact reduction) using a 5-point rating scale (1 = severe artifacts; 5 = no artifacts). Second, the standard deviation of different regions of interest (ROI) within each image was calculated and compared with the mean rating scores. Results: The interpolation-substitution technique successfully reduced metal artifacts in 70% of the cases. From a total of 60 images from 15 H&N cancer patients undergoing image guided radiation therapy, the mean rating score on the uncorrected images was 2.3 ± 1.1, versus 3.3 ± 1.0 for the corrected images. The mean difference in ranking score between uncorrected and corrected images was 1.0 (95% confidence interval: 0.9-1.2, P<.05). The standard deviation of each ROI significantly decreased after artifact reduction (P<.01). Moreover, a negative correlation between the mean rating score for each image and the standard deviation of the oral cavity and bilateral cheeks was observed. Conclusion: The interpolation-substitution algorithm is efficient and effective for reducing metal artifacts caused by dental fillings and implants on CBCT images, as demonstrated by the statistically significant increase in observer image quality ranking and by the decrease in ROI standard deviation between uncorrected and corrected images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance, improved software design, and manufacturer–user training may help mitigate these events.

07 ISOTOPE AND RADIATION SOURCES↗

Medical Device Recalls in Radiation Oncology: Analysis of US Food and Drug Administration Data, 2002-2015

Purpose: To analyze all recalls involving radiation oncology devices (RODs) from the US Food and Drug Administration (FDA)'s recall database, comparing these with non–radiation oncology device recalls to identify discipline-specific trends that may inform improvements in device safety. Methods and Materials: Recall data on RODs from 2002 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems). Outcomes included determined cause of recall, recall class (severity), quantity in commerce, time until recall termination (date FDA determines recall is complete), and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 502 ROD recalls and 9534 other class II device recalls during 2002 to 2015. Most recalls were for external beam devices (66.7%) and planning systems (22.9%), and recall events peaked in 2011. Radiation oncology devices differed significantly from other devices in all recall outcomes (P≤.04). Recall cause was commonly software related (49% vs 10% for other devices). Recall severity was more often moderate among RODs (97.6% vs 87.2%) instead of severe (0.2% vs 4.4%; P<.001). Time from 510(k) market approval to recall was shorter among RODs (P<.001) and progressively shortened over time. Radiation oncology devices had fewer recalled devices in commerce than other devices (P<.001). Conclusions: Compared with other class II devices, RODs experience recalls sooner after market approval and are trending sooner still. Most of these recalls were moderate in severity, and software issues are prevalent. Comprehensive analysis of recall data can identify areas for device improvement, such as better system design among RODs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Epitopes recognition of SARS-CoV-2 nucleocapsid RNA binding domain by human monoclonal antibodies

Coronavirus nucleocapsid protein (NP) of SARS-CoV-2 plays a central role in many functions important for virus proliferation including packaging and protecting genomic RNA. The protein shares sequence, structure, and architecture with nucleocapsid proteins from betacoronaviruses. The N-terminal domain (NP RBD ) binds RNA and the C-terminal domain is responsible for dimerization. After infection, NP is highly expressed and triggers robust host immune response. The anti-NP antibodies are not protective and not neutralizing but can effectively detect viral proliferation soon after infection. Two structures of SARS-CoV-2 NP RBD were determined providing a continuous model from residue 48 to 173, including RNA binding region and key epitopes. Five structures of NP RBD complexes with human mAbs were isolated using an antigen-bait sorting. Complexes revealed a distinct complement-determining regions and unique sets of epitope recognition. This may assist in the early detection of pathogens and designing peptide-based vaccines. Mutations that significantly increase viral load were mapped on developed, full length NP model, likely impacting interactions with host proteins and viral RNA.

59 BASIC BIOLOGICAL SCIENCES↗

Site heterogeneity and broad surface-binding isotherms in modern catalysis: Building intuition beyond the Sabatier principle

Learning the science of heterogeneous catalysis and electrocatalysis always starts with the simple case of a flat, uniform surface with an ideal adsorbate. It has of course been recognized for a century that real catalysts are more complicated. For the increasingly complex catalysts of the 21st century, this Perspective argues that surface heterogeneity and non-ideal binding isotherms are central features, and their implications need to be incorporated in current thinking. A variety of systems are described herein where catalyst complexity leads to broad, non-Langmuirian surface isotherms for the binding of hydrogen atoms – and this occurs even for ideal, flat Pt(111) surfaces. Modern catalysis employs nanoscale materials whose surfaces have substantial step, edge, corner, impurity, and other defect sites, and they increasingly have both metallic and non-metallic elements M n X m , including metal oxides, chalcogenides, pnictides, carbides, doped carbons, etc. The surfaces of such catalysts are often not crystal facets of the bulk phase underneath, and they typically have a variety of potential active sites. Catalytic surfaces in operando are often non-stoichiometric, amorphous, dynamic, and impure, and often vary from one part of the surface to another. Understanding of the issues that arise at such nanoscale, multi-element catalysts is just beginning to emerge. Yet these catalysts are widely discussed using Brønsted/Bell-Evans-Polanyi (BEP) relations, volcano plots, Tafel slopes, the Butler-Volmer equation, and other linear free energy relations (LFERs), which all depend on the implicit assumption that the active sites are “similar” and that surface adsorption is close to ideal. These assumptions underly the ubiquitous intuition based on the Sabatier Principle, that the fastest catalysis will occur when key intermediates have free energies of adsorption that are not too strong nor too weak. Current catalysis research often aims to minimize the complexity of non-ideal isotherms through experimental and computational design (e.g., the use of single crystal surfaces), and these studies are the foundation of the field. In contrast, this Perspective argues that the heterogeneity of binding sites and binding energies is an inherent strength of these catalysts. Here, this diversity makes many nanoscale catalysts inherently a high-throughput screen wrapped in a tiny package. Only by making the heterogeneity part of the foundation of catalysis models, sorting the types of active sites and dissecting non-ideal binding isotherms, will modern catalysis learn to harness the inherent diversity of real catalysts. Controlling and exploiting diversity rather than avoiding it will help to optimize complex modern catalysts and catalytic conditions.

Mayer, James M.↗

Structural and Thermodynamic Comparison of the Catalytic Domain of AMSH and AMSH-LP: Nearly Identical Fold but Different Stability

AMSH plays a critical role in the ESCRT (endosomal sorting complexes required for transport) machinery, which facilitates the down-regulation and degradation of cell-surface receptors. It displays a high level of specificity toward cleavage of Lys63-linked polyubiquitin chains, the structural basis of which has been understood recently through the crystal structure of a highly related, but ESCRT-independent, protein AMSH-LP (AMSH-like protein). We have determined the X-ray structure of two constructs representing the catalytic domain of AMSH: AMSH244, the JAMM (JAB1/MPN/MOV34)-domain-containing polypeptide segment from residues 244 to 424, and AMSH219{sup E280A}, an active-site mutant, Glu280 to Ala, of the segment from 219 to 424. In addition to confirming the expected zinc coordination in the protein, the structures reveal that the catalytic domains of AMSH and AMSH-LP are nearly identical; however, guanidine-hydrochloride-induced unfolding studies show that the catalytic domain of AMSH is thermodynamically less stable than that of AMSH-LP, indicating that the former is perhaps structurally more plastic. Much to our surprise, in the AMSH219{sup E280A} structure, the catalytic zinc was still held in place, by the compensatory effect of an aspartate from a nearby loop moving into a position where it could coordinate with the zinc, once again suggesting the plasticity of AMSH. Additionally, a model of AMSH244 bound to Lys63-linked diubiquitin reveals a type of interface for the distal ubiquitin significantly different from that seen in AMSH-LP. Altogether, we believe that our data provide important insight into the structural difference between the two proteins that may translate into the difference in their biological function.

Davies, Christopher W.↗

Evolution and characterization of a new reversibly photoswitching chromogenic protein, Dathail

In this paper, we report the engineering of a new reversibly switching chromogenic protein, Dathail. Dathail was evolved from the extremely thermostable fluorescent proteins thermal green protein (TGP) and eCGP123 using directed evolution and ratiometric sorting. Dathail has two spectrally distinct chromogenic states with low quantum yields, corresponding to absorbance in a ground state with a maximum at 389 nm, and a photo-induced metastable state with a maximum at 497 nm. In contrast to all previously described photoswitchable proteins, both spectral states of Dathail are non-fluorescent. The photo-induced chromogenic state of Dathail has a lifetime of ~ 50 min at 293 K and pH 7.5 as measured by UV–Vis spectrophotometry, returning to the ground state through thermal relaxation. X-ray crystallography provided structural insights supporting a change in conformation and coordination in the chromophore pocket as being responsible for Dathail's photoswitching. Neutron crystallography, carried out for the first time on a protein from the green fluorescent protein family, showed a distribution of hydrogen atoms revealing protonation of the chromophore 4-hydroxybenzyl group in the ground state. Additionally, the neutron structure also supports the hypothesis that the photo-induced proton transfer from the chromophore occurs through water-mediated proton relay into the bulk solvent. Beyond its spectroscopic curiosity, Dathail has several characteristics that are improvements for applications, including low background fluorescence, large spectral separation, rapid switching time, and the ability to switch many times. Therefore, Dathail is likely to be extremely useful in the quickly developing fields of imaging and biosensors, including photochromic Förster resonance energy transfer, high-resolution microscopy, and live tracking within the cell.

59 BASIC BIOLOGICAL SCIENCES↗

Molecular dynamics studies of helium bubble effects on grain boundary fracture vulnerabilities in an Fe 70 Ni 11 Cr 19 –1%H austenitic stainless steel

Comprehensive molecular dynamics tensile test simulations have been performed to study the delamination processes of seven different grain boundaries / cleavage planes (Σ1{111}, Σ3{111}, Σ5{100}, Σ7{111}, Σ9{411}, Σ11{311}, and R{100}/{411}) containing a helium bubble. Combinations of a variety of conditions are explored including different strain rates, system dimensions, bubble density, bubble radius, bubble pressure, and temperature. We found that in general, grain boundaries absorb less energies with decreasing strain rate but increasing bubble areal density, bubble pressure, bubble radius, and temperature. The propensity of grain boundary delamination is sensitive to grain boundary type: The random grain boundary R{100}/{411} is one of the most brittle boundaries whereas the Σ1{111} cleavage plane and the Σ3{111} twin boundary are two of the toughest boundaries. The sorted list of grain boundary fracture vulnerability obtained from our dynamic tensile test simulations differs from the one obtained from our decohesion energy calculations, confirming the important role of plastic deformation during fracture. Finally, detailed mechanistic analyses are performed to interpret the simulated results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescence and confocal imaging of mammalian cells using conjugated oligoelectrolytes with phenylenevinylene core

Over the last few years, considerable efforts are taken, in order to find a molecular fluorescent probe fulfilling their applicability requirements. Due to a good optical properties and affinity to biological structures conjugated oligoelectrolytes (COEs) can be considered as a promising dyes for application in fluorescence-based bioimaging. In this work, we synthetized COEs with phenylenevinylene core (PV-COEs) and applied as fluorescent membranous-specific probes. Cytotoxicity effects of each COE were probed on cancerous and non-cancerous cell types and little to no toxicity effects were observed at the high range of concentrations. The intensity of cell fluorescence following the COE staining was determined by the photoluminescence analysis and fluorescence activated cell sorting method (FACS). Intercalation of tested COEs into mammalian cell membranes was revealed by fluorescent and confocal microscopy colocalization with commercial dyes specific for cellular structures including mitochondria, Golgi apparatus and endoplasmic reticulum. The phenylenevinylene conjugated oligoelectrolytes have been found to be suitable for fluorescent bioimaging of mammalian cells and membrane-rich organelles. Due to their water solubility coupled with spontaneous intercalation into cells, favorable photophysical features, ease of cell staining, low cytotoxicity and selectivity for membranous structures, PV-COEs can be applied as markers for fluorescence imaging of a variety of cell types.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Failure statistics for commercial lithium ion batteries: A study of 24 pouch cells

There are relatively few publications that assess capacity decline in enough commercial cells to quantify cell-to-cell variation, but those that do show a surprisingly wide variability. Capacity curves cross each other often, a challenge for efforts to measure the state of health and predict the remaining useful life (RUL) of individual cells. We analyze capacity fade statistics for 24 commercial pouch cells, providing an estimate for the time to 5% failure. Our data indicate that RUL predictions based on remaining capacity or internal resistance are accurate only once the cells have already sorted themselves into “better” and “worse” ones. Analysis of our failure data, using maximum likelihood techniques, provide uniformly good fits for a variety of definitions of failure with normal and with 2- and 3-parameter Weibull probability density functions, but we argue against using a 3-parameter Weibull function for our data. pdf fitting parameters appear to converge after about 15 failures, although business objectives should ultimately determine whether data from a given number of batteries provides sufficient confidence to end lifecycle testing. Increased efforts to make batteries with more consistent lifetimes should lead to improvements in battery cost and safety.

25 ENERGY STORAGE↗

Radial feature descriptors for cell classification and recommendation

This paper introduces computational tools for cell classification into normal and abnormal, as well as content-based-image-retrieval (CBIR) for cell recommendation. It also proposes the radial feature descriptors (RFD), which define evenly interspaced segments around the nucleus, and proportional to the convexity of the nuclear boundary. Experiments consider Herlev and CRIC image databases as input to classification via Random Forest and bootstrap; we compare 14 different feature sets by means of False Negative Rate (FNR) and Kappa (κ), obtaining FNR =0.02 and κ=0.89 for Herlev, and FNR =0.14 and κ=0.78 for CRIC. Next, we sort and rank cell images using convolutional neural networks and evaluate performance with the Mean Average Precision (MAP), achieving MAP =0.84 and MAP =0.82 for Herlev and CRIC, respectively. Finally, cell classification show encouraging results regarding RFD, including its sensitivity to intensity variation around the nuclear membrane as it bypasses cytoplasm segmentation.

47 OTHER INSTRUMENTATION↗

A critical review of existing and emerging technologies and systems to optimize solid waste management for feedstocks and energy conversion

Solid waste generation and its accumulation is increasing at an alarming pace due to population growth and urbanization posing severe risks to health, safety, and natural ecosystems. Herein this review strategically addresses the challenges and solutions to increasing the sustainability footprint of solid waste management (SWM) systems by revealing multipronged approaches that reduce solid waste and handling costs while generating revenue and reducing greenhouse gas and related emissions. For example, the United States sends ~150 million tons of waste to landfills, which is composed of over 75% organic and recyclable materials having a potential to be diverted to alternative scenarios. The emergence of an automated upstream and downstream sorting process for solid waste to increase material diversion from landfills is a promising approach for creating sustainable SWM. The utilization of artificial-intelligence-enabled smart and automated systems at the home and industrial scales, comprehensive public re-education including awareness of the adverse effects of landfilled waste on the ecosystem, and more eco-friendly product development are required to significantly reduce landfills and their negative footprint.

09 BIOMASS FUELS↗