Solar Steam on Demand

INTRODUCTION: This Report summarizes the research and development project performed by Sunvapor and the subrecipient National Renewable Energy Laboratory (NREL) during the period of 10/01/2018-9/30/2021. The work was aimed at the economic integration of solar steam with an industrial process, and in particular, the advantages that a novel type of thermal energy storage and collector design could bring to the system. The completed work includes experimental research on the storage material, design of the collector, engineering of a complete solar steam plant, and economic analysis. The plant was, in the end, not constructed, due to COVID-19 impacts to the project host. PURPOSE: The purpose of the project was to test the hypothesis that a levelized cost of heat (LCOH) of 2¢/kWh delivered to a steam-consuming process, including energy discharged from storage, could be feasibly achieved. PROJECT OBJECTIVES: For Budget Period 1 our objectives were to engineer a prototype industrial solar steam generation system, and design and test a Latent Heat Energy Storage (LHES) lab-scale system. For Budget Period 2 our objectives were to construct and test the solar steam prototype plant, and to build and factory-test a full LHES module. For Budget Period 3 our objective was to integrate the storage module with the solar steam generator, show successful long duration energy tests of the combined system, and use the results to project the LCOH of delivered steam to a second-generation plant. PROJECT OUTCOMES: Various phase change materials (PCMs) for the LHES were tested for compatibility with industrial steam uses as measured by phase change temperature, stability of latent heat of fusion, and their corrosive effects on steel (the heat exchanger material). Two of these materials (sodium formate and sodium/ potassium) showed potential to meet the technical criteria. The estimated cost of a complete LHES module with these materials did not meet economic targets. The developmental collector design builds from previous work to exploit the potential cost advantages of a spaceframe of lumber construction. Design improvements were achieved in assembly efficiency and structural performance. A complete engineering package was completed for the solar steam system without storage that included the developmental as well as commercial arrays. The plant was permitted for construction. The storage CAPEX for a reference plant was estimate to be greater than $\$ 57$/kWh. The LCOH of the system without storage and with developmental collectors of lumber construction was projected to be 2¢/kWh, assuming a FCR of 8.2% over thirty years. PROJECT MILESTONES: The Milestones fully achieved in the first Budget Period includes obtaining a Letter of Intent from an industrial steam-consuming project host, issuance of a construction permit, and corrosion resistance. The Milestone that was partly achieved was the degradation in the latent heat of fusion. Milestones associated with Budget Periods 2 and 3, related to the construction and operation of the plant were not achieved as a result of the host shutting down the plant due to COVID-19 impacts. CONCLUSIONS: Sunvapor was able to secure an agreement with a host to build a fully engineered and permitted solar steam plant that met the host’s economic goals. As a basis for comparison, the solar field design was comprised of eight commercial collector arrays and one developmental Green Parabolic Trough Collector (GPTC) array. The projected LCOH with a solar field entirely populated with a second generation GPTC met the goal of 2¢/kWh. The experimental program concerning the PCM indicated the feasibility of meeting their technical requirements for industrial steam uses. The cost of the complete LHES exceeded its $\$ 14$/kWh target, and therefore the inclusion of LHES could not be economically justified. Due to COVID-19 impacts on the host, the solar steam plant was not constructed.

14 SOLAR ENERGY↗

Low-cost crushed-rock heat storage with oil or salt heat transfer

The demand for variable electricity and heat is met by fossil-fuel power plants because the power plant capital costs and the cost of storing fossil fuels are low. A low-carbon economy requires replacement of the storage function of fossil fuels to provide variable heat and electricity as needed. The Crushed Rock Ultra-large Stored Heat (CRUSH) system is a new technology with the goal to provide heat storage at an incremental capital cost of $2–4/kWh at scales of 10 s to 100 s of GWhs that enables economic daily to multi-week storage. CRUSH can be coupled to nuclear power plants, concentrated solar power (CSP) plants and thermal energy batteries to provide variable electricity and heat on demand. Sensible heat is stored in crushed rock—the lowest-cost heat-storage material. Heat is transferred to and from the crushed rock using nitrate salt or heat-transfer oils but these fluids do not store heat. Heat from a nuclear reactor, CSP plant or conversion of low-price electricity into heat is used to heat the salt or oil. The hot fluid is poured over the crushed rock, trickles downward by gravity through the rock, heats the rock and is collected by the drain pans under the crushed rock. To recover heat cold salt or oil is poured over hot crushed rock, trickles down by gravity while being heated and is collected by the drain pans under the crushed rock. The system design and engineering trade-offs are described. The technology is in the early stages of development.

20 FOSSIL-FUELED POWER PLANTS↗

Numerical study of advanced solar receiver tubes based on a coupled thermo-mechanical analysis for concentrated solar power tower plant

The search for more sustainable energy to match the growing energy demand begins with finding more dispatchable resources such as solar energy. As one of the promising solar technologies, concentrated solar power (CSP) has a full capacity to store thermal energy for extended operation. Nevertheless, some key components in CSP systems usually face extreme environment, such as uneven solar flux, cyclic thermal expansion, structural degradation on the solar absorber tubes in a Concentrated Solar Power Tower (CSPT) Plant. In this study, we applied Multiphysics simulation to explore the benefits of introducing optimized fins for heat transfer enhancement and uniform temperature distribution, the goal is to improve the thermal efficiency of such advanced solar absorber tubes. The results of this study can supply design guidance for the manufacturing process of absorber tubes, and eventually can benefit the solar energy community for the next generation of molten salt based CSP system.

14 SOLAR ENERGY↗

Observations of Subduction, Downward Heat Flux and Dense Filament Collapse in the Northern Gulf of Mexico

Submesoscale processes are important contributors to the global heat budget and generally support upward heat transport through restratification. However, in salinity‐stratified regions, such as the northern Gulf of Mexico with its influx of freshwater from the Mississippi‐Atchafalaya river system, temperature can act like a passive tracer and submesoscale processes can contribute to downward heat transport. Oceanic heat content is a factor in many environmental risks the region faces, for example, hurricane intensification, and marine heatwaves. During the 2022 field campaign of the Submesoscales Under Near‐Resonant Inertial Shear Experiment, a sampling plan was developed to study such submesoscale processes in high resolution. Over 31 hr, four assets (two research ships and two remotely controlled boats) drove in parallel across a dense filament, capturing its evolution in time and space. The observations show that surface waters, warmed by daytime solar radiation, were subducted and that the associated overturning circulation transported heat below the surface layer where it was later irreversibly mixed away. The estimated downward heat flux was as strong as the concurrent net air‐sea heat flux into the ocean. The filament was then observed to rapidly collapse which we attribute to boundary layer turbulence and the breakdown of geostrophic balance. The collapsing fronts display behaviors indicative of gravity currents. These observations highlight how in salinity‐stratified regions, frontal dynamics can be associated with downward heat flux and how the submesoscale can play an important role in the oceanic heat budget.

58 GEOSCIENCES↗

Thermal Analysis of a Solid Particle Light-Trapping Planar Cavity Receiver Using Computational Fluid Dynamics

Concentrated solar power (CSP) is one of the most effective ways of harnessing solar power to create efficient, durable, and resilient energy systems. This study entails thermal modeling and analysis of a novel central tower receiver configuration. This receiver uses solid particles as the heat transfer fluid (HTF), a promising option for third-generation CSP systems. The configuration considered here is the light-trapping planar cavity receiver (LTPCR) introduced by the National Renewable Energy Laboratory. While heat transfer studies of various LTPCR subsystems have been done, system-level thermal analysis of the LTPCR receiver has not been attempted. This study also presents important sensitivity analyses of the operating parameters of the CSP system, which can help guide the design of future central tower receivers. This study employs Ansys Fluent as a computational fluid dynamics (CFD) tool to model fluid dynamics and heat transfer in the receiver, intending to quantify its thermal performance. The model seamlessly integrates Monte Carlo ray tracing data, which generates absorbed solar flux profiles from the heliostat field design, with the heat transfer characteristics of the fluidized particle bed. This unified model is designed to accurately predict the thermal behavior of the LTPCR. Analysis of preliminary results reveals that the primary loss mechanisms are radiative and natural convective losses, in that order. Based on observations from a baseline case, several strategies are suggested and numerically tested. These solutions include selective cooling of high-temperature regions and manipulation of particle bed parameters. Selective cooling of high-temperature regions reduced the peak temperature by 151 degrees C and decreased thermal losses by 0.9%. Improving the particle-wall heat transfer coefficient (P-W HTC) of the particle bed decreased the thermal losses by 1.7% and decreased the peak temperatures by 57 degrees C. Decreasing the particle inlet temperature (PIT) also reduced thermal losses by 3.5% and decreased peak temperatures by 29 degrees C. Compounding these strategies improved the thermal losses of the receiver from 13.5% in the baseline case to 7.5%. Additionally, the study explores the variation in thermal performance across different locations of the receiver, where a variation of thermal losses from 12.9% to 17.3% is found. This allows a comprehensive evaluation of potential improvements in efficiency and temperature management.

computational fluid dynamics↗

Thermal modeling of three lakes within the continuous permafrost zone in Alaska using the LAKE 2.0 model

Abstract. Lakes in the Arctic are important reservoirs of heat with much lower albedo in summer and greater absorption of solar radiation than surrounding tundra vegetation. In the winter, lakes that do not freeze to their bed have a mean annual bed temperature >0 ∘C in an otherwise frozen landscape. Under climate warming scenarios, we expect Arctic lakes to accelerate thawing of underlying permafrost due to warming water temperatures in the summer and winter. Previous studies of Arctic lakes have focused on ice cover and thickness, the ice decay process, catchment hydrology, lake water balance, and eddy covariance measurements, but little work has been done in the Arctic to model lake heat balance. We applied the LAKE 2.0 model to simulate water temperatures in three Arctic lakes in northern Alaska over several years and tested the sensitivity of the model to several perturbations of input meteorological variables (precipitation, shortwave radiation, and air temperature) and several model parameters (water vertical resolution, sediment vertical resolution, depth of soil column, and temporal resolution). The LAKE 2.0 model is a one-dimensional model that explicitly solves vertical profiles of water state variables on a grid. We used a combination of meteorological data from local and remote weather stations, as well as data derived from remote sensing, to drive the model. We validated modeled water temperatures with data of observed lake water temperatures at several depths over several years for each lake. Our validation of the LAKE 2.0 model is a necessary step toward modeling changes in Arctic lake ice regimes, lake heat balance, and thermal interactions with permafrost. The sensitivity analysis shows us that lake water temperature is not highly sensitive to small changes in air temperature or precipitation, while changes in shortwave radiation and large changes in precipitation produced larger effects. Snow depth and lake ice strongly affect water temperatures during the frozen season, which dominates the annual thermal regime of Arctic lakes. These findings suggest that reductions in lake ice thickness and duration could lead to more heat storage by lakes and enhanced permafrost degradation.

Clark, Jason A. (ORCID:0000000248105261)↗

Solar Thermochemical Carbon Dioxide Splitting Using Ceria and Iron Aluminate Foam Devices and Simulation of a Plant System for Demonstration

An international research project has been undertaken to integrate a unique solar thermal processing reactor system with ceria and iron aluminate as active redox materials for CO2 splitting. Experimental investigations for CO2 splitting were conducted using a solar simulator and tube furnace at Niigata University, followed by demonstrations using a high-flux solar furnace (HFSF) at the National Renewable Energy Laboratory (NREL) in Golden, CO. Each experimental setup consisted of foam devices composed of reticulated porous ceramic (RPC). The RPC has a full ceria or iron aluminate body. It fabricated using the replica method and subjected to a two-step redox reaction, which iteratively separated a stream of CO2 into O2 and CO. Reactivity was evaluated using CO production per mass of the reactive material. The tubular furnace yielded a CO production of 6.41 mL/g at a reduction temperature of 1600degrees C, showcasing a higher CO production rate and total amount than those obtained from experiments conducted with solar simulators and solar furnace setups. For iron aluminate RPC, the productivity was measured as 3.57 mL/g using HFSF at a reduction temperature of 1450degrees C. These results are somewhat higher than those of the previous experiment at lower reduction temperatures of 1400degrees C-1500degrees C. Additionally, the production of CO in the case of ceria RPC was compared with the steady flow model simulation, which assumed chemical equilibrium at various levels of oxygen partial pressure during the reduction process. On the basis of these results, this study proposes a solar fuel system with an open receiver that uses a high-temperature heat transfer fluid.

carbon dioxide thermochemical splitting↗

Particle-wall heat transfer in narrow-channel bubbling fluidized beds for thermal energy storage

Robust metal oxide particles can provide low-cost and stable thermal energy storage (TES) to temperatures up to 1200 °C or higher. The transfer of heat into and out of the particles in cost-effective high-temperature particle heat exchangers remains a principal challenge to implementing particle-based TES. The present work expands on prior studies of particle-wall heat transfer in narrow-channel fluidized beds operated in the bubbling fluidization regime. Batch-mode experiments with various oxide particles over a range of temperatures and airflow rates indicate that particle-wall heat transfer increases with higher bed temperature and decreasing particle size. Measured particle-wall heat transfer coefficients in a 12 mm deep channel are fit to a Nusselt number correlation proportional to a non-monotonic function of excess fluidization velocity. Particle-wall heat transfer coefficients rise rapidly with excess fluidization velocities until reaching a maximum at intermediate air velocities due to a trade-off between enhanced transverse particle mixing and decreasing particle volume fraction with increased fluidization velocity. The heat transfer coefficient reaches a maximum of ≈ 400% of values without fluidization for oxide particles ranging in diameter d p from 159 to 408 μm. For the smallest particles tested, composed of olivine sand, particle-wall heat transfer coefficients peak above 1100 Wm –2 K –1 at 450 °C. 100-h tests at 500 °C and near-optimal heat transfer fluidization velocities indicated minimal wall wear or oxide scaling. Furthermore, high particle-wall heat transfer coefficients suggest narrow channel fluidized beds as a potential pathway for reducing the required surface area and cost of high-temperature particle heat exchangers, as needed in large-scale thermal energy storage applications.

14 SOLAR ENERGY↗

Modeling of Additively Manufactured Ceramic Heat Exchangers with Semi-Elliptical Cross-Section Flow Channels

An approximate and easily applied analytical model was developed for heat transfer calculations of heat exchangers consisting of multiple rows and columns of heat transfer fluid flow channels with semi-elliptical cross sections. Heat exchangers of this type are being developed by using ceramic material and additive manufacturing for high temperature and pressure-concentrating solar electric power plants. Calculations using the model require only the geometrical dimensions and flow conditions of the heat exchanger. Comparisons of modeling predictions, with both simulation results and experimental data, were conducted to verify the viability of the model. The results showed good agreement where almost all the modeling predictions were within 20% of the simulation results or the experimental data. Finally, the proposed modeling approach is more generally applicable to heat transfer analysis of heat exchangers with similar flow channel configurations to those considered in this study.

Ceramic↗

Temperature statistics in a radiatively heated particle-laden turbulent square duct flow

Radiation absorption by preferentially concentrated particles in a turbulent square duct flow is studied experimentally. The particle-laden flow is exposed to near-infrared radiation, and the gas phase temperature statistics are measured along the wall bisector of the duct. It is found that the instantaneous temperature fluctuations are comparable to the overall mean temperature rise. The temperature statistics at the duct centerline and near the wall are qualitatively different. The former reflects preferential concentration in isotropic flows while the latter displays evidence of particle clustering into streamwise elongated streaks. Comparison of the experimental data to a simplified heat transfer model suggests that the Lagrangian evolution of particle clusters and voids, and turbulent mixing in the vicinity of particle clusters, are important. This work was motivated by particle solar receiver technology, but the findings are also relevant to systems where there is localized heat release or mass transfer from disperse particles or droplets. It shows that obtaining Lagrangian histories of particle trajectories is an important next step towards understanding thermal transport phenomena in particle-laden turbulent flows.

42 ENGINEERING↗

Ion versus Electron Heating in Compressively Driven Astrophysical Gyrokinetic Turbulence

The partition of irreversible heating between ions and electrons in compressively driven (but subsonic) collisionless turbulence is investigated by means of nonlinear hybrid gyrokinetic simulations. We derive a prescription for the ion-to-electron heating ratio Q i /Q e as a function of the compressive-to-Alfvénic driving power ratio P compr /P AW , of the ratio of ion thermal pressure to magnetic pressure β i , and of the ratio of ion-to-electron background temperatures T i /T e . It is shown that Q i /Q e is an increasing function of P compr /P AW . When the compressive driving is sufficiently large, Q i /Q e approaches ≃P compr /P AW . This indicates that, in turbulence with large compressive fluctuations, the partition of heating is decided at the injection scales, rather than at kinetic scales. Analysis of phase-space spectra shows that the energy transfer from inertial-range compressive fluctuations to sub-Larmor-scale kinetic Alfvén waves is absent for both low and high β i , meaning that the compressive driving is directly connected to the ion-entropy fluctuations, which are converted into ion thermal energy. This result suggests that preferential electron heating is a very special case requiring low βi and no, or weak, compressive driving. Our heating prescription has wide-ranging applications, including to the solar wind and to hot accretion disks such as M87 and Sgr A*.

79 ASTRONOMY AND ASTROPHYSICS↗

Multijunction Electroluminescent Cooling

We propose a multijunction configuration for an electroluminescent cooling system, incorporating multiple semiconductor layers with different band gaps. Through theoretical analysis focusing on cooling power density and coefficient of performance, we show that increasing the number of semiconductor layers results in an enhanced performance of electroluminescent cooling. We highlight the reduction of operating voltage as a pivotal factor contributing to this improvement. Furthermore, we show that the enhancement can persist in the presence of nonradiative recombination. Our work indicates the potential of multijunction configurations in advancing the capabilities of electroluminescent cooling. Published by the American Physical Society 2024

14 SOLAR ENERGY↗

Helical Fins for Concentrated Solar Receivers: Design Optimization and Entropy Analysis

Concentrated solar power (CSP) with thermal energy storage (TES) has the potential to achieve grid parity. This can be realized by operating CSP systems at temperatures above 700 °C with high-efficiency sCO 2 power cycles. However, operating CSP systems at such temperatures poses several challenges, among which the design of solar receivers to accommodate increased thermal loads is critical. To this end, this work explores and optimizes various swirl-inducing internal fin designs for solar receiver tubes. These fin designs not only improve the thermal performance of receiver tubes but also levelize temperature unevenness caused by non-uniform thermal loading. In this work, the geometric parameters of the fin designs are optimized to maximize the Nusselt number with a constraint on the friction factor. This optimization, however, is computationally intensive, requiring hundreds of simulation calls to computational fluid dynamics (CFD) models. Here, to circumvent this problem, surrogate models are used to approximate the simulation outputs needed during the optimization. In addition, this study also examines the fin designs from an entropy generation perspective. To this end, the entropy contributions from thermal and viscous effects are quantitatively compared while varying the operational Reynolds number.

14 SOLAR ENERGY↗

A Laboratory Comparison of a Nephelometer and the Cavity-Attenuated Phase Shift Instrument (CAPS)

The interaction of incoming solar radiation (light) with particulate matter in the atmosphere impacts Earth’s radiation budget and thus is of great importance to climate and climate change. This particulate matter consists of particles, an aerosol referring to the ensemble of these particles. All particles scatter incoming solar radiation, sending some of it back to space and providing a cooling influence on the climate. Some particles additionally absorb incoming solar radiation, causing the particle, and the surrounding atmosphere, to heat, and thus altering atmospheric stability and evaporating water and other substances in the particles, which in turn affect the scattering and absorption of light by the particle.

54 ENVIRONMENTAL SCIENCES↗

AN OVERVIEW OF THE DESIGN AND PERFORMANCE TESTING OF A 275 BAR INTEGRALLY GEARED SUPERCRITICAL CO2 COMPRESSOR FOR POWER GENERATION

An integrally geared compressor-expander (compander) for supercritical CO2 (sCO2) was developed to convert thermal energy to electricity. With operating pressures of 275 bar, this turbomachine represents the state of the art in integrally geared machine architecture, hitting compressor inlet densities of 600 kg/m3 and discharge pressures of 275 bar. The product development was funded by the Department of Energy’s Energy Efficiency and Renewable Energy Office under EE0007114 to advance the state of the art in concentrated solar power applications; however, the technology itself is agnostic to heat source, and is predicted to achieve a thermal-to-electric conversion efficiency of 50% for any indirect heat source capable of providing turbine inlet temperatures of 700°C or greater. While the program encompassed the design and testing for the compressor and turbine elements, this paper will focus on the compressor design and operation. The paper will begin with an introduction to the cycle design and analysis of an indirectly heated integrally geared sCO2 compander, a discussion of the mechanical and aerodynamic design of the compressor that is a two stage radial compressor operating subcritically at 27,512 rpm, and will then proceed to describe the test facility and measured data to characterize the performance and robustness of the machine. The paper will conclude with a discussion on lessons learned throughout the course of commissioning and testing. Practical aspects of testing a compressor operating near the dome including complications relating to obtaining an accurate compressor flow map, efficiency calculations, flow unsteadiness, and associated measurement uncertainties will be discussed.

wilkes, jason↗

Polymer Inhibitors Enable >900 cm2 Dynamic Windows Based on Reversible Metal Electrodeposition with High Solar Modulation

Dynamic windows with adjustable tint give users control over the flow of light and heat to decrease the carbon footprint of buildings and improve the occupants’ comfort. Despite the benefits of dynamic windows, they are rarely deployed in buildings because the existing technology cannot achieve fast and colour-neutral tinting at an agreeable cost. Reversible metal electrodeposition is a promising approach to solve these problems. Here, we demonstrate the use of polymer inhibitors to reversibly deposit metal films with controlled morphology in dynamic windows. The windows that employ the polymer inhibitor can readily tint to below 0.001% visible transmittance in less than 3 min and exhibit high infrared reflectance (>70%), colour-neutral transmittance (C*<5) and an ultrawide range of optical and solar modulation (..delta..Tvis=0.76 and ..delta..SHGC=0.56). The polymer inhibitors also increase the efficiency and improve the durability of the windows and enable construction of >900 cm2 dynamic windows with fast response and excellent uniformity.

36 MATERIALS SCIENCE↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.