Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Listening for the Landing: Seismic Detections of Perseverance's Arrival at Mars With InSight

The entry, descent, and landing (EDL) sequence of NASA's Mars 2020 Perseverance Rover will act as a seismic source of known temporal and spatial localization. We evaluate whether the signals produced by this event will be detectable by the InSight lander (3,452 km away), comparing expected signal amplitudes to noise levels at the instrument. Modeling is undertaken to predict the propagation of the acoustic signal (purely in the atmosphere), the seismoacoustic signal (atmosphere-to-ground coupled), and the elastodynamic seismic signal (in the ground only). Our results suggest that the acoustic and seismoacoustic signals, produced by the atmospheric shock wave from the EDL, are unlikely to be detectable due to the pattern of winds in the martian atmosphere and the weak air-to-ground coupling, respectively. However, the elastodynamic seismic signal produced by the impact of the spacecraft's cruise balance masses on the surface may be detected by InSight. The upper and lower bounds on predicted ground velocity at InSight are 2.0 × 10 -14 and 1.3 × 10 -10 m s -1 . The upper value is above the noise floor at the time of landing 40% of the time on average. The large range of possible values reflects uncertainties in the current understanding of impact-generated seismic waves and their subsequent propagation and attenuation through Mars. Uncertainty in the detectability also stems from the indeterminate instrument noise level at the time of this future event. A positive detection would be of enormous value in constraining the seismic properties of Mars, and in improving our understanding of impact-generated seismic waves.

58 GEOSCIENCES↗

Enhanced Stability and Sensitivity for CA-125 Detection Under Microfluidic Shear Flow Using Polyethylene Glycol-Coated Biosensor

The microfluidic-based point-of-care (POC) diagnostic tool has garnered significant interest in recent years, offering rapid and cost-effective disease detection. There is a growing trend toward integrating microfluidic platforms with biosensors, aligning lab-on-a-chip technologies with POC diagnostic devices. Despite numerous efforts to incorporate biosensors into microfluidic systems, researchers have performed very limited investigations on the stability of biomarker detection when biosensors operate under microfluidic shear flow conditions. Gold nanoparticles (AuNPs) are a widely employed material in capacitive biosensors for antibody immobilization and sensitivity enhancement. However, AuNPs have limitations in providing stable detection of biomarkers within microfluidic shear flow due to their agglomeration nature. This study addresses these limitations by employing 2 kDa polyethylene glycol (PEG) as an intermediate biofunctional layer to immobilize CA-125 antibodies on gold-interdigitated electrodes for the stable and accurate detection of CA-125 antigens. The stabilities and sensitivities of AuNPs and PEG-coated biosensors are evaluated under both static drop and microfluidic shear flow conditions for CA-125 antigen detection. The experimental results demonstrate a capacitive signal response (5660 pF at 10 kHz) 2.2 times higher using the PEG-coated biosensor than the signal (2551 pF at 10 kHz) measured by the AuNP-coated biosensor in the detection of CA-125 antigen–antibody conjugation under static drop conditions, indicating the higher sensitivity of the PEG-coated biosensor. Additionally, the PEG-coated biosensor exhibits better consistency for the CA-125 antigen detection between static drop and microfluidic shear flow conditions (Cp decrease in percentage (ΔCp%↓) = 2.9% at 10 kHz) compared to the electrical signals measured using the AuNP-coated biosensor (ΔCp%↓ = 32.4% at 10 kHz), which suggests that the PEG-coated biosensor demonstrates higher stability for CA-125 antigen detection under microfluidic shear flow conditions. With these significant improvements brought by the PEG-coated biosensor, especially under microfluidic conditions, a substantial hurdle in developing electrical biosensors for POC diagnostic applications has been overcome, expediting further advancements in the field.

36 MATERIALS SCIENCE↗

Anthropogenic influence on extreme precipitation over global land areas seen in multiple observational datasets

The intensification of extreme precipitation under anthropogenic forcing is robustly projected by global climate models, but highly challenging to detect in the observational record. Large internal variability distorts this anthropogenic signal. Models produce diverse magnitudes of precipitation response to anthropogenic forcing, largely due to differing schemes for parameterizing subgrid-scale processes. Meanwhile, multiple global observational datasets of daily precipitation exist, developed using varying techniques and inhomogeneously sampled data in space and time. Previous attempts to detect human influence on extreme precipitation have not incorporated model uncertainty, and have been limited to specific regions and observational datasets. Using machine learning methods that can account for these uncertainties and capable of identifying the time evolution of the spatial patterns, we find a physically interpretable anthropogenic signal that is detectable in all global observational datasets. Machine learning efficiently generates multiple lines of evidence supporting detection of an anthropogenic signal in global extreme precipitation.

54 ENVIRONMENTAL SCIENCES↗

Trans-ionospheric signal polarization

An electromagnetic (EM) wave originating at or near the earth’s surface can propagate upwards, traverse the ionosphere, and then be detected at a satellite. While the signal’s magnitude will affect its detectabilty, its polarization will play an important role as well. Furthermore the signal polarization can reveal properties about its source, and the ionospheric conditions through which it traveled. Thus, it is desirable to predict the polarization characteristics of trans-ionospheric EM signals. This situation is complicated by the birefringence imposed on an EM wave propagating in the magnetized plasma of the ionosphere. Each frequency component of the signal can excite two waves that propagate at different phase velocities due to their separate refractive characteristics.For this work, the amplitude and phase of each EM wave field spatial component is followed as it crosses the lower ionospheric boundary, traverses the ionosphere and then crosses the upper boundary. Results are for a single frequency, and can be easily extended to broadband waveforms using fourier transform techniques.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling the Transmission of Optical Lightning Signals Through Complex 3‐D Cloud Scenes

Abstract Space‐based lightning imagers have shown that complex cloud scenes consisting of multiple tall convective features, anvil clouds, and warm boundary cloud layers are illuminated by lightning in many different ways depending on where the lightning occurs and how energetic it is. Modifications to the optical lightning signals from radiative transfer in the cloud medium can lead to reductions in detection efficiency and location accuracy for these instruments and can also cause some of the optical signals that are detected to have unexpected spatial energy distributions. In this study, we perform Monte Carlo radiative transfer simulations of optical lightning emissions in clouds with complex 3‐D geometries to shed some light on the origins of certain irregular radiance patterns that have been recorded from orbit. We show that diffuse reflections off nearby cloud faces can explain lightning signals in nonelectrified clouds, tall clouds can result in poor optical transmission and suppressed radiances that could lead to missed events and that particularly favorable viewing conditions can cause otherwise normal lightning to produce a superbolt that is orders of magnitude brighter than the same flash seen from a different angle.

54 ENVIRONMENTAL SCIENCES↗

Solar Neutrino Detection with a Pixelated Liquid-Argon Time Projection Chamber

This thesis presents a study of low-energy solar neutrino detection using large-scale LArTPCs, focussing on novel pixelated readout technologies. Solar neutrinos offer a unique probe of fundamental neutrino properties and solar physics, but their detection in the MeV range is challenged by backgrounds. We investigate two complementary technologies: SoLAr, which integrates LArPix-based pixelated charge collection with Silicon Photomultipliers (SiPMs) in a hybrid anode design for simultaneous charge and light detection; and Q-Pix, a triggerless pixelated readout architecture based on charge integrate-reset circuits with local clocks, where Reset Time Differences encode ionisation waveforms via time-to-charge conversion. Two SoLAr prototypes were developed and operated, demonstrating VUV-sensitive SiPM performance in liquid argon and accurate charge-light signal matching with a charge detection threshold of $\sim 100 \mathrm{keV}$. We also implement a complete simulation and reconstruction framework, incorporating realistic detector geometry, electron transport, readout response, and detailed signal and background models, including intrinsic argon and radon progeny, as well as site-specific $\gamma$-ray and neutron fluxes. For Q-Pix, we demonstrate that with a pixel size of $4\times 4$ mm$^2$ and a reset threshold of 1 fC ($\sim 0.1475$ MeV), full-scale operation produces data volumes below 1 PB per 10 ktonne-year. For SoLAr, assuming a shielded DUNE-like detector and 100 ktonne-year exposure, we project uncertainties of $0.90\times 10^{-5}$ eV$^2$ on $\Delta m^2_{21}$ and 0.033 on $\sin^2\theta_{12}$, improving to $0.46\times 10^{-5}$ eV$^2$ and 0.025 with 400 kilotonne-year. At this higher exposure, we also obtain a day–night flux asymmetry at the level of $( -5.6 \pm 3.6 ) \%$. Combining Monte Carlo modelling, hardware validation, and advanced reconstruction techniques, this work establishes a path toward next-generation ktonne-scale LArTPCs as observatories for precision solar neutrino physics.

Ruiz Ferreira, Guilherme [Manchester U.] (ORCID:00↗

Machine-learning based prediction of injection rate and solenoid voltage characteristics in GDI injectors

We report that current state-of-the-art gasoline direct-injection (GDI) engines use multiple injections as one of the key technologies to improve exhaust emissions and fuel efficiency. For this technology to be successful, secured adequate control of fuel quantity for each injection is mandatory. However, nonlinearity and variations in the injection quantity can deteriorate the accuracy of fuel control, especially with small fuel injections. Therefore, it is necessary to understand the complex injection behavior and to develop a predictive model to be utilized in the development process. This study presents a methodology for rate of injection (ROI) and solenoid voltage modeling using artificial neural networks (ANNs) constructed from a set of Zeuch-style hydraulic experimental measurements conducted over a wide range of conditions. A quantitative comparison between the ANN model and the experimental data shows that the model is capable of predicting not only general features of the ROI trend, but also transient and non-linear behaviors at particular conditions. In addition, the end of injection (EOI) could be detected precisely with a virtually generated solenoid voltage signal and the signal processing method, which applies to an actual engine control unit. A correlation between the detected EOI timings calculated from the modeled signal and the measurement results showed a high coefficient of determination.

42 ENGINEERING↗

Detection of multi-modal Doppler spectra – Part 1: Establishing characteristic signals in radar moment data

Vertically pointing millimeter-wavelength radars provide a wealth of information about cloud and precipitation particle properties. Doppler spectral data can inform on how particles of varying vertical velocities contribute to the total backscattered power observed. It is more computationally cost effective to process moment data instead of spectra data, but doing so leaves valuable information on the cutting room floor. To confidently identify a multi-modal spectra event, in which two or more modes are present within a layer, Doppler spectral data are essential. This means long-term identification of layers featuring multi-modal spectra can be cost prohibitive. To address this, we explore three multi-modal spectra cases from winter precipitation events to determine characteristic signatures of these layers in the moment data averaged over short time periods (∼ 145 s) and explore how these layers differ from the rest of the vertical profiles. We find that the mean spectrum width and the standard deviation of mean Doppler velocity can be used to determine whether or not a layer is multi-modal. In particular, multi-modal layers in mixed-phase and ice clouds feature larger mean spectrum width (exceeding 0.17 m s −1 ) and smaller standard deviation of the mean Doppler velocity (below 0.1 m s −1 ). In Part 1 of this study, the identification criteria and methods are described. In Part 2 (Wugofski and Kumjian, 2025), we perform a verification of the method for three years of vertically pointing radar data, and explore the meteorological conditions associated with identified multi-modal spectral events.

Wugofski, Sarah [Pennsylvania State Univ., Univers↗

Development of Lipid-Coated Semiconductor Nanosensors for Recording of Membrane Potential in Neurons

In the past decade, optical imaging methods have significantly improved our understanding of the information processing principles in the brain. Although many promising tools have been designed, sensors of membrane potential are lagging behind the rest. Semiconductor nanoparticles are an attractive alternative to classical voltage indicators, such as voltage-sensitive dyes and proteins. Such nanoparticles exhibit high sensitivity to external electric fields via the quantum-confine Stark effect. Here we report the development of semiconductor voltage-sensitive nanorods (vsNRs) that self-insert into the neuronal membrane. To facilitate interaction of the nanorods with the membrane, we functionalized their surface with the lipid mixture derived from brain extract. We describe a workflow to detect and process the photoluminescent signal of vsNRs after widefield time-lapse recordings. We also present data indicating that vsNRs are feasible for sensing membrane potential in neurons at a single-particle level. This shows the potential of vsNRs for the detection of neuronal activity with unprecedentedly high spatial and temporal resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Qualification study of SiPMs on a large scale for the CMVD Experiment

A Cosmic Muon Veto (CMV) detector using extruded plastic scintillators is being designed around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai for the feasibility study of shallow depth underground experiments. The scintillation signals that are produced in the plastic due to muon trajectories are absorbed by wavelength shifting (WLS) fibres. The WLS fibres re-emit photons of longer wavelengths and propagate those to silicon photo-multipliers (SiPMs). The SiPMs detect these photons, producing electronic signals. The CMV detector will use more than 700 scintillators to cover the mini-ICAL detector and will require around 3000 SiPMs. The design goal for the cosmic muon veto efficiency of the CMV is >99.99%. Hence, every SiPM used in the detector needs to be tested and characterised to satisfy the design goal of CMV. A mass testing system was developed for the measurement of gain and choice of the overvoltage ($V_{ov}$) of each SiPMs using an LED driver. The $V_{ov}$ is obtained by studying the noise rate, the gain of the SiPM. This paper describes the experimental setup used to test the SiPMs characteristics along with detailed studies of those characteristics as a function of temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seismically Detecting Nuclear Reactor Operations Using a Power Spectral Density (PSD) Misfit Detector

To explore the ability to indirectly detect and attribute various operations conducted at a nuclear reactor using waveform data, we investigated the seismic signals recorded near the High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory in Oak Ridge, Tennessee. Specifically, we processed seismic data collected from a single seismoacoustic station, WACO, near the HFIR facility, and employed a power spectral density misfit detector to identify signals of interest and associate the detections with operational events. Initial results suggest that this method provides a promising means of regularly detecting at least 19 unique operations. Furthermore, with additional station deployment and more comprehensive data logs, we anticipate that future analysis will offer an additional means to seismically monitor nuclear reactors (such as HFIR) health and performance more accurately.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

GW190425: Observation of a Compact Binary Coalescence with Total Mass ~ 3.4 M ⊙

On 2019 April 25, the LIGO Livingston detector observed a compact binary coalescence with signal-to-noise ratio 12.9. The Virgo detector was also taking data that did not contribute to detection due to a low signal-to-noise ratio, but were used for subsequent parameter estimation. The 90% credible intervals for the component masses range from 1.12 to 2.52 M ⊙ (1.46-1.87 M ⊙ if we restrict the dimensionless component spin magnitudes to be smaller than 0.05). These mass parameters are consistent with the individual binary components being neutron stars. However, both the source-frame chirp mass 1.44 +0.02 -0.02 M ⊙ and the total mass 3.4 +0.3 -0.1 M ⊙ of this system are significantly larger than those of any other known binary neutron star (BNS) system. The possibility that one or both binary components of the system are black holes cannot be ruled out from gravitational-wave data. We discuss possible origins of the system based on its inconsistency with the known Galactic BNS population. Under the assumption that the signal was produced by a BNS coalescence, the local rate of neutron star mergers is updated to 250-2810 Gpc -3 yr -1 .

79 ASTRONOMY AND ASTROPHYSICS↗

Absorption of fermionic dark matter by nuclear targets

Absorption of fermionic dark matter leads to a range of distinct and novel signatures at dark matter direct detection and neutrino experiments. We study the possible signals from fermionic absorption by nuclear targets, which we divide into two classes of four Fermi operators: neutral and charged current. In the neutral current signal, dark matter is absorbed by a target nucleus and a neutrino is emitted. This results in a characteristically different nuclear recoil energy spectrum from that of elastic scattering. The charged current channel leads to induced $\beta$ decays in isotopes which are stable in vacuum as well as shifts of the kinematic endpoint of $ \beta$ spectra in unstable isotopes. To confirm the possibility of observing these signals in light of other constraints, we introduce UV completions of example higher dimensional operators that lead to fermionic absorption signals and study their phenomenology. Most prominently, dark matter which exhibits fermionic absorption signals is necessarily unstable leading to stringent bounds from indirect detection searches. Nevertheless, we find a large viable parameter space in which dark matter is sufficiently long lived and detectable in current and future experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data Analysis of the 2020 Central Idaho Mainshock-Aftershock Sequence

In an effort to inform the Senior Seismic Hazard Analysis Committee for the Idaho National Laboratory, we provide an improved aftershock catalog related to the March 31, 2020, Mw6.5 Stanley, Idaho earthquake from picks related to a temporary network of two real-time and 15 non-telemetered seismometers within the epicentral area. From the permanent and temporary (XP) real-time network, the USGS cataloged 1,946 aftershocks between April 1, 2020 and October 31, 2020. To improve aftershock location and magnitudes, we manually picked arrival times of P and S waves from off-line stations in the XP temporary network, generated a new crustal velocity model, and independently relocated each event using the HypoDD double-difference earthquake algorithm. We created our new velocity model from existing broadband and active source seismic campaign data that were acquired near the epicentral region prior to the 2020 earthquake. We compare arrival time differences, epicentral locations and depths between aftershocks recorded with the two catalogs. We find the addition of local stations provides tighter aftershock clustering that suggests an improved aftershock locations. To detect lower magnitude events, we employed deep learning. Our method solves common problems associated with detecting many events that have a low signal-to-noise ratio. From the machine learning database, we detected more than 74,000 aftershocks. Based on the number of identified earthquakes and Gutenberg-Richter relationships derived from the USGS catalog, we estimate that we have reduced the completion magnitude for the Stanley earthquake sequence to below M1 using this machine learning approach. We located each aftershock with our new velocity model. Our new velocity model and picks suggests aftershocks occurred mostly at shallower depths than assessed in the USGS catalog. These aftershocks align along two linear trends that suggest the activation of two unnamed primary faults.

58 GEOSCIENCES↗

Determining the Structure of Rotating Massive Stellar Cores with Gravitational Waves

The gravitational wave (GW) signal resulting from stellar core collapse encodes a wealth of information about the physical parameters of the progenitor star and the resulting core-collapse supernova (CCSN). We present a novel approach to constrain CCSN progenitor properties at collapse using two of the most detectable parts of the GW signal: the core-bounce signal and evolution of the dominant frequency mode from the protoneutron star. We focus on the period after core bounce but before explosion and investigate the predictive power of GWs from rotating CCSNe to constrain properties of the progenitor star. We analyze 34 2D and four 3D neutrino-radiation-hydrodynamic simulations of stellar core collapse in progenitors of varied initial mass and rotation rate. Extending previous work, we verify the compactness of the progenitor at collapse to correlate with the early ramp-up slope, and in rotating cases, also with the core angular momentum. Combining this information with the bounce signal, we present a new analysis method to constrain the pre-collapse core compactness of the progenitor. Because these GW features occur less than a second after core bounce, this analysis could allow astronomers to predict electromagnetic properties of a resulting CCSN even before shock breakout.

Astronomy & Astrophysics↗