Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Automatic lung segmentation from thoracic computed tomography scans using a hybrid approach with error detection

Lung segmentation is a prerequisite for automated analysis of chest CT scans. Conventional lung segmentation methods rely on large attenuation differences between lung parenchyma and surrounding tissue. These methods fail in scans where dense abnormalities are present, which often occurs in clinical data. Some methods to handle these situations have been proposed, but they are too time consuming or too specialized to be used in clinical practice. In this article, a new hybrid lung segmentation method is presented that automatically detects failures of a conventional algorithm and, when needed, resorts to a more complex algorithm, which is expected to produce better results in abnormal cases. In a large quantitative evaluation on a database of 150 scans from different sources, the hybrid method is shown to perform substantially better than a conventional approach at a relatively low increase in computational cost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computer-aided measurement of liver volumes in CT by means of geodesic active contour segmentation coupled with level-set algorithms

Purpose: Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. Methods: The authors developed a computerized liver extraction scheme based on geodesic active contour segmentation coupled with level-set contour evolution. First, an anisotropic diffusion filter was applied to portal-venous-phase CT images for noise reduction while preserving the liver structure, followed by a scale-specific gradient magnitude filter to enhance the liver boundaries. Then, a nonlinear grayscale converter enhanced the contrast of the liver parenchyma. By using the liver-parenchyma-enhanced image as a speed function, a fast-marching level-set algorithm generated an initial contour that roughly estimated the liver shape. A geodesic active contour segmentation algorithm coupled with level-set contour evolution refined the initial contour to define the liver boundaries more precisely. The liver volume was then calculated using these refined boundaries. Hepatic CT scans of 15 prospective liver donors were obtained under a liver transplant protocol with a multidetector CT system. The liver volumes extracted by the computerized scheme were compared to those traced manually by a radiologist, used as ''gold standard.''Results: The mean liver volume obtained with our scheme was 1504 cc, whereas the mean gold standard manual volume was 1457 cc, resulting in a mean absolute difference of 105 cc (7.2%). The computer-estimated liver volumetrics agreed excellently with the gold-standard manual volumetrics (intraclass correlation coefficient was 0.95) with no statistically significant difference (F=0.77; p(F{<=}f)=0.32). The average accuracy, sensitivity, specificity, and percent volume error were 98.4%, 91.1%, 99.1%, and 7.2%, respectively. Computerized CT liver volumetry would require substantially less completion time (compared to an average of 39 min per case by manual segmentation). Conclusions: The computerized liver extraction scheme provides an efficient and accurate way of measuring liver volumes in CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combining registration and active shape models for the automatic segmentation of the lymph node regions in head and neck CT images

Purpose: Intensity-modulated radiation therapy (IMRT) is the state of the art technique for head and neck cancer treatment. It requires precise delineation of the target to be treated and structures to be spared, which is currently done manually. The process is a time-consuming task of which the delineation of lymph node regions is often the longest step. Atlas-based delineation has been proposed as an alternative, but, in the authors' experience, this approach is not accurate enough for routine clinical use. Here, the authors improve atlas-based segmentation results obtained for level II-IV lymph node regions using an active shape model (ASM) approach. Methods: An average image volume was first created from a set of head and neck patient images with minimally enlarged nodes. The average image volume was then registered using affine, global, and local nonrigid transformations to the other volumes to establish a correspondence between surface points in the atlas and surface points in each of the other volumes. Once the correspondence was established, the ASMs were created for each node level. The models were then used to first constrain the results obtained with an atlas-based approach and then to iteratively refine the solution. Results: The method was evaluated through a leave-one-out experiment. The ASM- and atlas-based segmentations were compared to manual delineations via the Dice similarity coefficient (DSC) for volume overlap and the Euclidean distance between manual and automatic 3D surfaces. The mean DSC value obtained with the ASM-based approach is 10.7% higher than with the atlas-based approach; the mean and median surface errors were decreased by 13.6% and 12.0%, respectively. Conclusions: The ASM approach is effective in reducing segmentation errors in areas of low CT contrast where purely atlas-based methods are challenged. Statistical analysis shows that the improvements brought by this approach are significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D automatic anatomy segmentation based on iterative graph-cut-ASM

Purpose: This paper studies the feasibility of developing an automatic anatomy segmentation (AAS) system in clinical radiology and demonstrates its operation on clinical 3D images. Methods: The AAS system, the authors are developing consists of two main parts: object recognition and object delineation. As for recognition, a hierarchical 3D scale-based multiobject method is used for the multiobject recognition task, which incorporates intensity weighted ball-scale (b-scale) information into the active shape model (ASM). For object delineation, an iterative graph-cut-ASM (IGCASM) algorithm is proposed, which effectively combines the rich statistical shape information embodied in ASM with the globally optimal delineation capability of the GC method. The presented IGCASM algorithm is a 3D generalization of the 2D GC-ASM method that they proposed previously in Chen et al.[Proc. SPIE, 7259, 72590C1-72590C-8 (2009)]. The proposed methods are tested on two datasets comprised of images obtained from 20 patients (10 male and 10 female) of clinical abdominal CT scans, and 11 foot magnetic resonance imaging (MRI) scans. The test is for four organs (liver, left and right kidneys, and spleen) segmentation, five foot bones (calcaneus, tibia, cuboid, talus, and navicular). The recognition and delineation accuracies were evaluated separately. The recognition accuracy was evaluated in terms of translation, rotation, and scale (size) error. The delineation accuracy was evaluated in terms of true and false positive volume fractions (TPVF, FPVF). The efficiency of the delineation method was also evaluated on an Intel Pentium IV PC with a 3.4 GHZ CPU machine. Results: The recognition accuracies in terms of translation, rotation, and scale error over all organs are about 8 mm, 10 deg. and 0.03, and over all foot bones are about 3.5709 mm, 0.35 deg. and 0.025, respectively. The accuracy of delineation over all organs for all subjects as expressed in TPVF and FPVF is 93.01% and 0.22%, and all foot bones for all subjects are 93.75% and 0.28%, respectively. While the delineations for the four organs can be accomplished quite rapidly with average of 78 s, the delineations for the five foot bones can be accomplished with average of 70 s. Conclusions: The experimental results showed the feasibility and efficacy of the proposed automatic anatomy segmentation system: (a) the incorporation of shape priors into the GC framework is feasible in 3D as demonstrated previously for 2D images; (b) our results in 3D confirm the accuracy behavior observed in 2D. The hybrid strategy IGCASM seems to be more robust and accurate than ASM and GC individually; and (c) delineations within body regions and foot bones of clinical importance can be accomplished quite rapidly within 1.5 min.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Texture analysis improves level set segmentation of the anterior abdominal wall

Purpose: The treatment of ventral hernias (VH) has been a challenging problem for medical care. Repair of these hernias is fraught with failure; recurrence rates ranging from 24% to 43% have been reported, even with the use of biocompatible mesh. Currently, computed tomography (CT) is used to guide intervention through expert, but qualitative, clinical judgments, notably, quantitative metrics based on image-processing are not used. The authors propose that image segmentation methods to capture the three-dimensional structure of the abdominal wall and its abnormalities will provide a foundation on which to measure geometric properties of hernias and surrounding tissues and, therefore, to optimize intervention.Methods: In this study with 20 clinically acquired CT scans on postoperative patients, the authors demonstrated a novel approach to geometric classification of the abdominal. The authors’ approach uses a texture analysis based on Gabor filters to extract feature vectors and follows a fuzzy c-means clustering method to estimate voxelwise probability memberships for eight clusters. The memberships estimated from the texture analysis are helpful to identify anatomical structures with inhomogeneous intensities. The membership was used to guide the level set evolution, as well as to derive an initial start close to the abdominal wall.Results: Segmentation results on abdominal walls were both quantitatively and qualitatively validated with surface errors based on manually labeled ground truth. Using texture, mean surface errors for the outer surface of the abdominal wall were less than 2 mm, with 91% of the outer surface less than 5 mm away from the manual tracings; errors were significantly greater (2–5 mm) for methods that did not use the texture.Conclusions: The authors’ approach establishes a baseline for characterizing the abdominal wall for improving VH care. Inherent texture patterns in CT scans are helpful to the tissue classification, and texture analysis can improve the level set segmentation around the abdominal region.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-71: Quality Assessment of Surrogate Metrics in Multi-Atlas-Based Image Segmentation

Purpose: With the ever-growing data of heterogeneous quality, relevance assessment of atlases becomes increasingly critical for multi-atlas-based image segmentation. However, there is no universally recognized best relevance metric and even a standard to compare amongst candidates remains elusive. This study, for the first time, designs a quantification to assess relevance metrics’ quality, based on a novel perspective of the metric as surrogate for inferring the inaccessible oracle geometric agreement. Methods: We first develop an inference model to relate surrogate metrics in image space to the underlying oracle relevance metric in segmentation label space, with a monotonically non-decreasing function subject to random perturbations. Subsequently, we investigate model parameters to reveal key contributing factors to surrogates’ ability in prognosticating the oracle relevance value, for the specific task of atlas selection. Finally, we design an effective contract-to-noise ratio (eCNR) to quantify surrogates’ quality based on insights from these analyses and empirical observations. Results: The inference model was specialized to a linear function with normally distributed perturbations, with surrogate metric exemplified by several widely-used image similarity metrics, i.e., MSD/NCC/(N)MI. Surrogates’ behaviors in selecting the most relevant atlases were assessed under varying eCNR, showing that surrogates with high eCNR dominated those with low eCNR in retaining the most relevant atlases. In an end-to-end validation, NCC/(N)MI with eCNR of 0.12 compared to MSD with eCNR of 0.10 resulted in statistically better segmentation with mean DSC of about 0.85 and the first and third quartiles of (0.83, 0.89), compared to MSD with mean DSC of 0.84 and the first and third quartiles of (0.81, 0.89). Conclusion: The designed eCNR is capable of characterizing surrogate metrics’ quality in prognosticating the oracle relevance value. It has been demonstrated to be correlated with the performance of relevant atlas selection and ultimate label fusion.

60 APPLIED LIFE SCIENCES↗

MO-AB-BRA-09: Temporally Realistic Manipulation a 4D Biomechanical Lung Phantom for Evaluation of Simultaneous Registration and Segmentation

Purpose: To produce multi-modality compatible, realistic datasets for the joint evaluation of segmentation and registration with a reliable ground truth using a 4D biomechanical lung phantom. The further development of a computer controlled air flow system for recreation of real patient breathing patterns is incorporated for additional evaluation of motion prediction algorithms. Methods: A pair of preserved porcine lungs was pneumatically manipulated using an in-house computer controlled respirator. The respirator consisted of a set of bellows actuated by a 186 W computer controlled industrial motor. Patient breathing traces were recorded using a respiratory bellows belt during CT simulation and input into a control program incorporating a proportional-integral-derivative (PID) feedback controller in LabVIEW. Mock tumors were created using dual compartment vacuum sealed sea sponges. 65% iohexol,a gadolinium-based contrast agent and 18F-FDG were used to produce contrast and thus determine a segmentation ground truth. The intensity distributions of the compartments were then digitally matched for the final dataset. A bifurcation tracking pipeline provided a registration ground truth using the bronchi of the lung. The lungs were scanned using a GE Discovery-ST PET/CT scanner and a Phillips Panorama 0.23T MRI using a T1 weighted 3D fast field echo (FFE) protocol. Results: The standard deviation of the error between the patient breathing trace and the encoder feedback from the respirator was found to be ±4.2%. Bifurcation tracking error using CT (0.97×0.97×3.27 mm{sup 3} resolution) was found to be sub-voxel up to 7.8 cm displacement for human lungs and less than 1.32 voxel widths in any axis up to 2.3 cm for the porcine lungs. Conclusion: An MRI/PET/CT compatible anatomically and temporally realistic swine lung phantom was developed for the evaluation of simultaneous registration and segmentation algorithms. With the addition of custom software and mock tumors, the entire package offers ground truths for benchmarking performance with high fidelity.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRA-05: Atlas Selection for Multi-Atlas-Based Image Segmentation Using Surrogate Modeling

Purpose: The growing size and heterogeneity in training atlas necessitates sophisticated schemes to identify only the most relevant atlases for the specific multi-atlas-based image segmentation problem. This study aims to develop a model to infer the inaccessible oracle geometric relevance metric from surrogate image similarity metrics, and based on such model, provide guidance to atlas selection in multi-atlas-based image segmentation. Methods: We relate the oracle geometric relevance metric in label space to the surrogate metric in image space, by a monotonically non-decreasing function with additive random perturbations. Subsequently, a surrogate’s ability to prognosticate the oracle order for atlas subset selection is quantified probabilistically. Finally, important insights and guidance are provided for the design of fusion set size, balancing the competing demands to include the most relevant atlases and to exclude the most irrelevant ones. A systematic solution is derived based on an optimization framework. Model verification and performance assessment is performed based on clinical prostate MR images. Results: The proposed surrogate model was exemplified by a linear map with normally distributed perturbation, and verified with several commonly-used surrogates, including MSD, NCC and (N)MI. The derived behaviors of different surrogates in atlas selection and their corresponding performance in ultimate label estimate were validated. The performance of NCC and (N)MI was similarly superior to MSD, with a 10% higher atlas selection probability and a segmentation performance increase in DSC by 0.10 with the first and third quartiles of (0.83, 0.89), compared to (0.81, 0.89). The derived optimal fusion set size, valued at 7/8/8/7 for MSD/NCC/MI/NMI, agreed well with the appropriate range [4, 9] from empirical observation. Conclusion: This work has developed an efficacious probabilistic model to characterize the image-based surrogate metric on atlas selection. Analytical insights lead to valid guiding principles on fusion set size design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Generic and robust method for automatic segmentation of PET images using an active contour model

Purpose: Although positron emission tomography (PET) images have shown potential to improve the accuracy of targeting in radiation therapy planning and assessment of response to treatment, the boundaries of tumors are not easily distinguishable from surrounding normal tissue owing to the low spatial resolution and inherent noisy characteristics of PET images. The objective of this study is to develop a generic and robust method for automatic delineation of tumor volumes using an active contour model and to evaluate its performance using phantom and clinical studies. Methods: MASAC, a method for automatic segmentation using an active contour model, incorporates the histogram fuzzy C-means clustering, and localized and textural information to constrain the active contour to detect boundaries in an accurate and robust manner. Moreover, the lattice Boltzmann method is used as an alternative approach for solving the level set equation to make it faster and suitable for parallel programming. Twenty simulated phantom studies and 16 clinical studies, including six cases of pharyngolaryngeal squamous cell carcinoma and ten cases of nonsmall cell lung cancer, were included to evaluate its performance. Besides, the proposed method was also compared with the contourlet-based active contour algorithm (CAC) and Schaefer’s thresholding method (ST). The relative volume error (RE), Dice similarity coefficient (DSC), and classification error (CE) metrics were used to analyze the results quantitatively. Results: For the simulated phantom studies (PSs), MASAC and CAC provide similar segmentations of the different lesions, while ST fails to achieve reliable results. For the clinical datasets (2 cases with connected high-uptake regions excluded) (CSs), CAC provides for the lowest mean RE (−8.38% ± 27.49%), while MASAC achieves the best mean DSC (0.71 ± 0.09) and mean CE (53.92% ± 12.65%), respectively. MASAC could reliably quantify different types of lesions assessed in this work with good accuracy, resulting in a mean RE of −13.35% ± 11.87% and −11.15% ± 23.66%, a mean DSC of 0.89 ± 0.05 and 0.71 ± 0.09, and a mean CE of 19.19% ± 7.89% and 53.92% ± 12.65%, for PSs and CSs, respectively. Conclusions: The authors’ results demonstrate that the developed novel PET segmentation algorithm is applicable to various types of lesions in the authors’ study and is capable of producing accurate and consistent target volume delineations, potentially resulting in reduced intraobserver and interobserver variabilities observed when using manual delineation and improved accuracy in treatment planning and outcome evaluation.

60 APPLIED LIFE SCIENCES↗

SU-F-J-97: A Joint Registration and Segmentation Approach for Large Bladder Deformations in Adaptive Radiotherapy

Purpose: To improve results of deformable image registration (DIR) in adaptive radiotherapy for large bladder deformations in CT/CBCT pelvis imaging. Methods: A variational multi-modal DIR algorithm is incorporated in a joint iterative scheme, alternating between segmentation based bladder matching and registration. Using an initial DIR to propagate the bladder contour to the CBCT, in a segmentation step the contour is improved by discrete image gradient sampling along all surface normals and adapting the delineation to match the location of each maximum (with a search range of +−5/2mm at the superior/inferior bladder side and step size of 0.5mm). An additional graph-cut based constraint limits the maximum difference between neighboring points. This improved contour is utilized in a subsequent DIR with a surface matching constraint. By calculating an euclidean distance map of the improved contour surface, the new constraint enforces the DIR to map each point of the original contour onto the improved contour. The resulting deformation is then used as a starting guess to compute a deformation update, which can again be used for the next segmentation step. The result is a dense deformation, able to capture much larger bladder deformations. The new method is evaluated on ten CT/CBCT male pelvis datasets, calculating Dice similarity coefficients (DSC) between the final propagated bladder contour and a manually delineated gold standard on the CBCT image. Results: Over all ten cases, an average DSC of 0.93±0.03 is achieved on the bladder. Compared with the initial DIR (0.88±0.05), the DSC is equal (2 cases) or improved (8 cases). Additionally, DSC accuracy of femoral bones (0.94±0.02) was not affected. Conclusion: The new approach shows that using the presented alternating segmentation/registration approach, the results of bladder DIR in the pelvis region can be greatly improved, especially for cases with large variations in bladder volume. Fraunhofer MEVIS received funding from a research grant by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Poster - 32: Atlas Selection for Automated Segmentation of Pelvic CT for Prostate Radiotherapy

Atlas based-segmentation has recently been evaluated for use in prostate radiotherapy. In a typical approach, the essential step is the selection of an atlas from a database that the best matches of the target image. This work proposes an atlas selection strategy and evaluate it impacts on final segmentation accuracy. Several anatomical parameters were measured to indicate the overall prostate and body shape, all of these measurements obtained on CT images. A brute force procedure was first performed for a training dataset of 20 patients using image registration to pair subject with similar contours; each subject was served as a target image to which all reaming 19 images were affinity registered. The overlap between the prostate and femoral heads was quantified for each pair using the Dice Similarity Coefficient (DSC). Finally, an atlas selection procedure was designed; relying on the computation of a similarity score defined as a weighted sum of differences between the target and atlas subject anatomical measurement. The algorithm ability to predict the most similar atlas was excellent, achieving mean DSCs of 0.78 ± 0.07 and 0.90 ± 0.02 for the CTV and either femoral head. The proposed atlas selection yielded 0.72 ± 0.11 and 0.87 ± 0.03 for CTV and either femoral head. The DSC obtained with the proposed selection method were slightly lower than the maximum established using brute force, but this does not include potential improvements expected with deformable registration. The proposed atlas selection method provides reasonable segmentation accuracy.

60 APPLIED LIFE SCIENCES↗

Research on a Pulmonary Nodule Segmentation Method Combining Fast Self-Adaptive FCM and Classification

The key problem of computer-aided diagnosis (CAD) of lung cancer is to segment pathologically changed tissues fast and accurately. As pulmonary nodules are potential manifestation of lung cancer, we propose a fast and self-adaptive pulmonary nodules segmentation method based on a combination of FCM clustering and classification learning. The enhanced spatial function considers contributions to fuzzy membership from both the grayscale similarity between central pixels and single neighboring pixels and the spatial similarity between central pixels and neighborhood and improves effectively the convergence rate and self-adaptivity of the algorithm. Experimental results show that the proposed method can achieve more accurate segmentation of vascular adhesion, pleural adhesion, and ground glass opacity (GGO) pulmonary nodules than other typical algorithms.

59 BASIC BIOLOGICAL SCIENCES↗

Panel-Segmentation [SWR-21-18]

Panel-Segmentation contains the scripts for automated metadata extraction of solar PV installations, using satellite imagery coupled with computer vision techniques. In this package, the user can perform the following actions: *Automatically generate a satellite image using a set of lat-long coordinates, and a Google Maps API key. Users would need to set up a Google Cloud account and get a Maps Static API key. Please refer to Setting Up Google Maps Static API Key section for this process. *Perform image segmentation on the satellite image, to locate the solar array(s) in the image on a pixel-by-pixel basis, using an image segmentation model (panel_detection_model.pth). Get classification of the installation (rooftop, ground mounted fixed-tilt or tracking, carport, etc). *Perform azimuth estimation on each solar array cluster in the masked image. *Detect solar panels and get its latitude, longitude, and address within a geographic bounding box through the SOL-Searcher Pipeline. *Detect and calculate hurricane damage on solar installations given pre-hurricane and post-hurricane satellite imagery through the Hurricane Detection Pipeline. *Detect and calculate hail damage on solar installations given satellite imagery through the Hail Detection pipeline. *Convert NOAA MESH (Maximum Estimated Size of Hail) grib2 files into kml or geojson files. *Estimate tilt and azimuth of a solar array by processing USGS LiDAR data for the array’s location.

Edun, Ayobami↗

Dataset for Top Model Decision Tree: Selecting Segmentation Models for Reliable Quantitative Analysis in Low- and Ultralow-Dose CryoEM

Motivation Multiple deep learning model architectures can be used to segment bacterial membranes in cryoEM images. However, an AI-based tool advancement is often presented with only a single segmentation model for broad use, and this single model may show inconsistent results across datasets from different users. Here, we present the Top Model Decision Tree, a model screening framework to screen for the best model to generate bacterial inner and outer membrane masks based on user priorities. We use pre-trained segmentation models from YOLOv11, YOLO26, U-Net, Detectron2 and SAM3 fine-tuned on bacterial inner and outer membranes imaged with cryoEM. Run the Framework This notebook must be opened in Google Colab. Mount Google Drive and run with a GPU-based runtime. Open the notebook and follow steps to git clone in folders and files within this repository. There will be a repeating top_model_decision_tree.ipynb (notebook clone) that will not be used. Save your .png binary mask files and .csv table outputs within your Google Drive or download before closing the notebook. The models and all analysis/training scripts are available at [GitHub: https://github.com/Lynnicia/CryoEM_membranes_top_model_decision_tree and https://github.com/Sireesiru/Semantic-Segmentation-of-bacterial-cell-envelope-using-U-Nets.

59 BASIC BIOLOGICAL SCIENCES↗

Dual-wavelength low-coherence instantaneous phase-shifting interferometer to measure the shape of a segmented mirror with subnanometer precision

We present a noncontact optical metrology measuring the pistons and tip/tilt angles of the 61 hexagonal segments of a compact-sized segmented mirror. The instrument has been developed within the scope of a design study for the European Extremely Large Telescope (E-ELT). It is used as reference sensor for cophasing of the mirror segments in closed-loop control. The mirror shape is also measured by different types of stellar light-based phasing cameras whose performances will be evaluated with regard to a future E-ELT. Following a description of the system architecture, the second part of the paper presents experimental results demonstrating the achieved precision: 0.48 nm rms in piston and 74 nrad rms in tip/tilt.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An intensity-based post-processing tool for 3D instance segmentation of organelles in soft X-ray tomograms

Investigating the 3D structures and rearrangements of organelles within a single cell is critical for better characterizing cellular function. Imaging approaches such as soft X-ray tomography have been widely applied to reveal a complex subcellular organization involving multiple inter-organelle interactions. However, 3D segmentation of organelle instances has been challenging despite its importance in organelle characterization. Here we propose an intensity-based post-processing tool to identify and separate organelle instances. Our tool separates sphere-like (insulin vesicle) and columnar-shaped organelle instances (mitochondrion) based on the intensity of raw tomograms, semantic segmentation masks, and organelle morphology. We validate our tool using synthetic tomograms of organelles and experimental tomograms of pancreatic β -cells to separate insulin vesicle and mitochondria instances. As compared to the commonly used connected regions labeling, watershed, and watershed + Gaussian filter methods, our tool results in improved accuracy in identifying organelles in the synthetic tomograms and an improved description of organelle structures in β -cell tomograms. In addition, under different experimental treatment conditions, significant changes in volumes and intensities of both insulin vesicle and mitochondrion are observed in our instance results, revealing their potential roles in maintaining normal β -cell function. Our tool is expected to be applicable for improving the instance segmentation of other images obtained from different cell types using multiple imaging modalities.

59 BASIC BIOLOGICAL SCIENCES↗

Reinforcement Learning as a Parsimonious Alternative to Prediction Cascades: A Case Study on Image Segmentation

Deep learning architectures have achieved state-of-the-art (SOTA) performance on computer vision tasks such as object detection and image segmentation. This may be attributed to the use of over-parameterized, monolithic deep learning architectures executed on large datasets. Although such large architectures lead to increased accuracy, this is usually accompanied by a larger increase in computation and memory requirements during inference. While this is a non-issue in traditional machine learning (ML) pipelines, the recent confluence of machine learning and fields like the Internet of Things (IoT) has rendered such large architectures infeasible for execution in low-resource settings. For some datasets, large monolithic pipelines may be overkill for simpler inputs. To address this problem, previous efforts have proposed decision cascades where inputs are passed through models of increasing complexity until the desired performance is achieved. However, we argue that cascaded prediction leads to sub-optimal throughput and increased computational cost due to wasteful intermediate computations. To address this, we propose PaSeR (Parsimonious Segmentation with Reinforcement Learning) a non-cascading, cost-aware learning pipeline as an efficient alternative to cascaded decision architectures. Through experimental evaluation on both real-world and standard datasets, we demonstrate that PaSeR achieves better accuracy while minimizing computational cost relative to cascaded models. Further, we introduce a new metric IoU/GigaFlop to evaluate the balance between cost and performance. On the real-world task of battery material phase segmentation, PaSeR yields 179% improvement over SOTA MatPhase model and a 196% improvement over IDK Cascades under the IoU/GigaFlop metric. We also demonstrate PaSeR’s adaptability to complementary models trained on a noisy MNIST dataset, where it outperforms all baselines on IoU/GigaFlop by an average of 44%.

Srikshan, Bharat↗

Multi Segment Fault Rupture Modeling and Strong Ground Motion Simulation Using Irikura, Japan Recipe: Implementation in the in SCEC BB Platform

The project had two main objectives. The first objective was to complete the implementation of an earthquake rupture generator based on the method proposed by Irikura and Miyake, also known as Irikura recipe (IM2011 method hereafter), in the BBP by extending its formulation to multi-segment rupture, and developing the software infrastructure. The second objective was to investigate the possibility of using the earthquake rupture generator as a standalone BBP rupture module that can be attached to other strong ground motion simulation methods already in use in the BBP. We successfully tested and validated the IM2011 multi-segment rupture generator in conjunction with Graves and Pitarka method (GP, hereafter) one of the BBP methods, and performed simulations of the M7.0 2016 Kumamoto, Japan earthquake. IM2011 is the most popular method in Japan that is used to simulate strong ground motion from Japanese crustal earthquakes. In response to technical requirements of the BBP, we made Irikura’s rupture generator procedure compatible with multi-segment rupture modeling approach, currently being adopted by BBP. The recipe is now fully functional on the BBP. This project benefited from the collaboration of the PI with professor Kojiro Irikura of Aichi Institute of Technology, Japan, assistant professor Hiroe Miyake of University of Tokyo, head of the Japanese side of collaboration with SCEC, and Dr.Iwaki and Dr. Morikawa, researchers at NIED, during which we identified rupture parameters that needed to be adjusted and investigated.

58 GEOSCIENCES↗